Search NASA⌕ Search

SEARCH · Search NASA

Results for “coolant control module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Robotic External Leak Locator (RELL) Leak Plume Field Detection on the International Space Station (ISS)

The Robotic External Leak Locator (RELL) was deployed to the International Space Station (ISS) with the objective of demonstrating the ability to detect and locate small leaks. On-orbit operations began in late November 2016 and following scanning activities to characterize the natural and induced environment of the ISS, RELL focused on the United States External Active Thermal Control System (EATCS). RELL successfully detected ammonia related to a known small ammonia leak in the port-side EATCS, with the highest pressure values around the inboard Radiator Beam Valve Module 1 (RBVM 1). An additional day of scanning was subsequently performed in December 2017 to focus on RBVM 1. RELL was approved for additional external operations in February 2017 with the goal of fine tuning the location of the leak. Using grid scanning patterns, RELL detected ammonia around RBVM 1 and located the approximate source of the leak. The potential leak site was inspected by a crew member during an Extravehicular Activity (EVA) in March 2017, and the suspected radiator-side lines were isolated from the port-side EATCS coolant loop in April 2017. Subsequent monitoring of the system pressures showed that the leak has stopped, indicating RELL accurately located the source of the EATCS leak. These activities verify that RELL enhances the ISS Program's ability to not only locate small leaks, but isolate the source with minimal impact to the entire ISS system.

External Active Thermal Control System↗

Reliability enhancement of APR + diverse protection system regarding common cause failures

The Advanced Power Reactor Plus (APR +) nuclear power plant design has been developed on the basis of the APR1400 (Advanced Power Reactor 1400 MWe) to further enhance safety and economics. For the mitigation of Anticipated Transients Without Scram (ATWS) as well as Common Cause Failures (CCF) within the Plant Protection System (PPS) and the Emergency Safety Feature - Component Control System (ESF-CCS), several design improvement features have been implemented for the Diverse Protection System (DPS) of the APR + plant. As compared to the APR1400 DPS design, the APR + DPS has been designed to provide the Safety Injection Actuation Signal (SIAS) considering a large break LOCA accident concurrent with the CCF. Additionally several design improvement features, such as channel structure with redundant processing modules, and changes of system communication methods and auto-system test methods, are introduced to enhance the functional reliability of the DPS. Therefore, it is expected that the APR + DPS can provide an enhanced safety and reliability regarding possible CCF in the safety-grade I and C systems as well as the DPS itself. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Upgrade of the mechanically pumped CO 2 two-phase cooling system for the alpha magnetic spectrometer on the international space station

This study describes the successful upgrade of a mechanically pumped CO 2 two-phase cooling system in space by designing a new pump module for the Alpha Magnetic Spectrometer-02 on the International Space Station. Key factors for mission success are emphasized, including achieving high coolant filling accuracy within 10% of the target and maintaining system stability within ±1 °C. The impact of adding radiators to improve cooling efficiency is examined, and it is found that operating multi-radiators out-of-phase does not significantly affect system reliability. The centrifugal pump design is shown to allow for better lubricant circulation, while the in-house designed controller incorporates protective measures to prevent cavitation, overheating, and over-current. Further, this research advances the understanding of circulation loop systems and their upgrades in space and demonstrates the potential for extending the lifetime of space-borne mechanically pumped two-phase cooling systems.

42 ENGINEERING↗

Method and apparatus for maintaining thermal control in plasma conditions

An apparatus and method are disclosed for determining the effects of exposure of oxygen plasma on a thin film polymer whose bulk is maintained at a predetermined temperature. The apparatus includes a chamber having a specimen therein. A plasma environment is provided in the chamber. A closure member is provided for sealing the chamber after the specimen is introduced into the chamber. The closure member also serves as a support for the test apparatus which includes a cooling coil. A platform having the test specimen thereon is supported on the cooling coil to be cooled by coolant flowing through the cooling coils. A thermoelectric module is supported on the platform to assist in maintaining a low test temperature for the test samples. The temperature of the sample is monitored by a thermocouple probe which is in contact with the sample. Any change in bulk sample temperature caused by the thermocouple probe is quickly adjusted to maintain the initial bulk temperature by the thermoelectric module.

Whitaker, Ann F.↗

Developing a Model Component

The Spaceport Command and Control System (SCCS) Simulation Computer Software Configuration Item (CSCI) is responsible for providing simulations to support test and verification of SCCS hardware and software. The Universal Coolant Transporter System (UCTS) was a Space Shuttle Orbiter support piece of the Ground Servicing Equipment (GSE). The initial purpose of the UCTS was to provide two support services to the Space Shuttle Orbiter immediately after landing at the Shuttle Landing Facility. The UCTS is designed with the capability of servicing future space vehicles; including all Space Station Requirements necessary for the MPLM Modules. The Simulation uses GSE Models to stand in for the actual systems to support testing of SCCS systems during their development. As an intern at Kennedy Space Center (KSC), my assignment was to develop a model component for the UCTS. I was given a fluid component (dryer) to model in Simulink. I completed training for UNIX and Simulink. The dryer is a Catch All replaceable core type filter-dryer. The filter-dryer provides maximum protection for the thermostatic expansion valve and solenoid valve from dirt that may be in the system. The filter-dryer also protects the valves from freezing up. I researched fluid dynamics to understand the function of my component. The filter-dryer was modeled by determining affects it has on the pressure and velocity of the system. I used Bernoulli's Equation to calculate the pressure and velocity differential through the dryer. I created my filter-dryer model in Simulink and wrote the test script to test the component. I completed component testing and captured test data. The finalized model was sent for peer review for any improvements. I participated in Simulation meetings and was involved in the subsystem design process and team collaborations. I gained valuable work experience and insight into a career path as an engineer.

Fields, Christina M.↗

Development of a High Output Fluorescent Light Module for the Commercial Plant Biotechnology Facility

To maximize the use of available resources provided onboard the International Space Station, the development of an efficient lighting 1 system is critical to the overall performance of the CPBF. Not only is it important to efficiently generate photon energy, but thermal loads on the CPBF Temperature and Humidity Control System must be minimized. By utilizing optical coatings designed to produce highly diffuse reflectance in the visible wavelengths while minimizing reflectance in the infrared region, the design of the fluorescent light module for the CPBF is optimized for maximum photon flux, spatial uniformity and energy efficiency. Since the Fluorescent Light Module must be fully enclosed to meet (ISS) requirements for containment of particulates and toxic materials, heat removal from the lights presented some unique design challenges. By using the Express Rack moderate C, temperature-cooling loop, heat is rejected by means of a liquid/air coolant manifold. Heat transfer to the manifold is performed by conduction using copper fins, by forced air convection using miniature fans, and by radiation using optically selective coatings that absorb in the infrared wavelengths. Using this combination of heat transfer mechanisms builds in redundancy to prevent thermal build up and premature bulb failure.

Turner, Mark↗

Nuclear modules for space electric propulsion

Analysis of interplanetary cargo and piloted missions requires calculations of the performances and masses of subsystems to be integrated in a final design. In a preliminary and scoping stage the designer needs to evaluate options iteratively by using fast computer simulations. The Oak Ridge National Laboratory (ORNL) has been involved in the development of models and calculational procedures for the analysis (neutronic and thermal hydraulic) of power sources for nuclear electric propulsion. The nuclear modules will be integrated into the whole simulation of the nuclear electric propulsion system. The vehicles use either a Brayton direct-conversion cycle, using the heated helium from a NERVA-type reactor, or a potassium Rankine cycle, with the working fluid heated on the secondary side of a heat exchanger and lithium on the primary side coming from a fast reactor. Given a set of input conditions, the codes calculate composition. dimensions, volumes, and masses of the core, reflector, control system, pressure vessel, neutron and gamma shields, as well as the thermal hydraulic conditions of the coolant, clad and fuel. Input conditions are power, core life, pressure and temperature of the coolant at the inlet of the core, either the temperature of the coolant at the outlet of the core or the coolant mass flow and the fluences and integrated doses at the cargo area. Using state-of-the-art neutron cross sections and transport codes, a database was created for the neutronic performance of both reactor designs. The free parameters of the models are the moderator/fuel mass ratio for the NERVA reactor and the enrichment and the pitch of the lattice for the fast reactor. Reactivity and energy balance equations are simultaneously solved to find the reactor design. Thermalhydraulic conditions are calculated by solving the one-dimensional versions of the equations of conservation of mass, energy, and momentum with compressible flow.

Difilippo, F. C.↗

Numerical Implementation of Source Terms to Evaluate Active Porosity Control using a Transpiration Cooled Thermal Protection System

Transpiration cooling has renewed interest of study as a renewable system of thermal protection for atmospheric entry systems. The presence of coolant within the void space of a porous material changes its effective porosity and theorized to lend the external heatshield as a potential means of porous surface control. Effective porosity is explored in two forms: saturation of void space where exiting coolant creates ‘blowing’ over the surface, and partial evacuation of the void space where withdrawal of the coolant creates ‘suction’ on the surface. Thus this study evaluates using transpiration cooling as a as means of active aerodynamic control. The feasibility of the system is evaluated numerically using Reynolds-averaged Navier Stokes based computational fluid dynamics for the aerodynamic assessments by coding source terms of transpiration cooling products at a heat shield surface boundary at the wind side shoulder, creating an asymmetric scheme. Study results show induced moments about the pitch axis incurred following the source terms of a cooling fluid at a near-shoulder location on the heat shield. Lift and drag saw increasing modulation with increase in mass flux rate. Pitch moment was altered a total of 388 N-m between lowest and highest ‘suction’ rates and changed 194 N-m maximum between ‘blowing’ rates.

transpiration cooling↗

A Soft-Switching Inverter for High-Temperature Advanced Hybrid Electric Vehicle Traction Motor Drives

The state-of-the-art hybrid electric vehicles (HEVs) require the inverter cooling system to have a separate loop to avoid power semiconductor junction over temperatures because the engine coolant temperature of 105°C does not allow for much temperature rise in silicon devices. The proposed work is to develop an advanced soft-switching inverter that will eliminate the device switching loss and cut down the power loss so that the inverter can operate at high-temperature conditions while operating at high switching frequencies with small current ripple in low inductance based permanent magnet motors. The proposed tasks also include high-temperature packaging and thermal modeling and simulation to ensure the packaged module can operate at the desired temperature. The developed module will be integrated with the motor and vehicle controller for dynamometer and in-vehicle testing to prove its superiority. This report will describe the detailed technical design of the soft-switching inverters and their test results. The experiments were conducted both in module level for the module conduction and switching characteristics and in inverter level for its efficiency under inductive and dynamometer load conditions. The performance will be compared with the DOE original specification.

33 ADVANCED PROPULSION SYSTEMS↗

SHARP Multiphysics Tutorials

SHARP, developed under the NEAMS Reactor Product Line, is an advanced modeling and simulation toolkit for the analysis of advanced nuclear reactors. SHARP is comprised of three physics modules currently including neutronics, thermal hydraulics, and structural mechanics. SHARP empowers designers to produce accurate results for modeling physical phenomena that have been identified as important for nuclear reactor analysis. SHARP can use existing physics codes and take advantage of existing infrastructure capabilities in the MOAB framework and the coupling driver/solver library, the Coupled Physics Environment (CouPE), which utilizes the widely used, scalable PETSc library. This report aims at identifying the coupled-physics simulation capability of SHARP by introducing the demonstration example called sahex in advance of the SHARP release expected by Mar 2016. sahex consists of 6 fuel pins with cladding, 1 control rod, sodium coolant and an outer duct wall that encloses all the other components. This example is carefully chosen to demonstrate the proof of concept for solving more complex demonstration examples such as EBR II assembly and ABTR full core. The workflow of preparing the input files, running the case and analyzing the results is demonstrated in this report. Moreover, an extension of the sahex model called sahex_core, which adds six homogenized neighboring assemblies to the full heterogeneous sahex model, is presented to test homogenization capabilities in both Nek5000 and PROTEUS. Some primary information on the configuration and build aspects for the SHARP toolkit, which includes capability to auto-download dependencies and configure/install with optimal flags in an architecture-aware fashion, is also covered by this report. A step-by-step instruction is provided to help users to create their cases. Details on these processes will be provided in the SHARP user manual that will accompany the first release.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multi-Scale Modeling of Thermal-Fluid Phenomena Related to Loss of Forced Circulation Transient in HTGRs

Under the support of DOE-NE’s Nuclear Energy Advanced Modeling and Simulation (NEAMS), an effort had been pursued to support High Temperature Gas-cooled Reactors (HTGR) technology development and its modeling and simulation needs. There was a particular need for advanced modeling & simulation tools to predict thermal-fluid behavior in the nuclear reactor primary system, especially the core and lower and upper plena, during safety-related transients. In this report, two main such activities were presented: 1) system level HTGR simulations using system analysis code SAM for both normal operating and accident conditions; and 2) three-dimensional (3D) computational fluid dynamics (CFD) simulations on Deteriorated Turbulent Heat Transfer (DTHT) of interest to HTGR transients, including code benchmark and closure correlation development. In this work, Modular High Temperature Gas-cooled Reactor (MHTGR) full loop simulations were performed using System Analysis Module (SAM) code. Two approaches were used to model the reactor core; (i) unit-cell or lumped parameter model, and (ii) detailed ring model, to address the different needs under different reactor conditions. Aside from the core model changes other reactor components in the primary system, such as upper/lower plenum, heat exchanger and blower etc, were kept the same. In the unit-cell core model, the lumped parameter approach was used to model the coolant channels and the heat structures using 1-D and 2-D components, respectively. The fuel assembly heat structure was modeled based on unit-cell thickness approximation. In normal and controlled operating conditions, the calculated maximum temperatures for both coolant and heat structures were within the designed limits. The unit-cell model is, however, not able to capture the radial heat conduction through fuel assemblies, which is the dominant heat transfer mechanism during accident transients, such as pressurized conduction cooldown (PCC) event. To address this modeling challenge, ring models were developed. A simplified ring model was developed first. In this simplified model, the active core was simulated with 9 circular rings consists of 6 rings for homogenized fuel heat structure and 3 rings for gas coolant. It was quickly found that this model gives rather large simulation error as it was not able to correctly capture the solid structure representative geometries. A detailed ring model was developed to address this issue. The active core was simulated with 99 circular rings consists of 66 rings for homogenized fuel heat structure and 33 rings for gas coolant. In both ring models, six additional rings were included to represent inner reflector, outer reflector, core barrel, Reactor Pressure Vessel (RPV), RPV coolant channel, and Reactive Cavity Cooling System (RCCS). The detailed ring model was applied in two different SAM simulations; (i) normal operating conditions, and (ii) accident scenarios (more specifically, PCC event), for MHTGR design. In both simulations, the SAM calculated results for coolant and heat structure temperatures were within the reactor designed limits. The newly proposed detailed ring model approach in this work has proved to be a promising method to address the challenging modeling and simulation needs in the MHTGR design. As demonstrated in this work, this model was suitable for MHTGR simulations under both normal and accident conditions. Apart from the SAM model development for gas-cooled reactors, 3D Computational Fluid Dynamics (CFD) models were developed and validated with relaminarized Deteriorated Turbulent Heat Transfer (DTHT) MIT benchmark test. Two different CFD codes, Nek5000 and STAR-CCM+, were used for this benchmark activity. Compared with MIT data, Nek5000 shows very good agreement between its simulated and experimentally measured wall temperatures. In contrast, STAR-CCM+ under-predicted wall temperature due to over predicted turbulence in the wall region. The Nek5000 code was also used to develop wall-heat transfer correlations for laminar flow in cylindrical tube. Several simulations were performed for various Reynolds flow and wall heat fluxes. Significant deviations were found when compared the predicted heat transfer coefficient and the Sieder-Tate correlation. A new set of heat transfer correlation was proposed for laminar flow which is valid for 400<Re<2000.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Stationary Liquid Fuel Fast Reactor

For effective burning of hazardous transuranic (TRU) elements of used nuclear fuel, a transformational advanced reactor concept named SLFFR (Stationary Liquid Fuel Fast Reactor) was proposed based on stationary molten metallic fuel. The fuel enters the reactor vessel in a solid form, and then it is heated to molten temperature in a small melting heater. The fuel is contained within a closed, thick container with penetrating coolant channels, and thus it is not mixed with coolant nor flow through the primary heat transfer circuit. The makeup fuel is semi- continuously added to the system, and thus a very small excess reactivity is required. Gaseous fission products are also removed continuously, and a fraction of the fuel is periodically drawn off from the fuel container to a processing facility where non-gaseous mixed fission products and other impurities are removed and then the cleaned fuel is recycled into the fuel container. A reference core design and a preliminary plant system design of a 1000 MWt TRU- burning SLFFR concept were developed using TRU-Ce-Co fuel, Ta-10W fuel container, and sodium coolant. Conservative design approaches were adopted to stay within the current material performance database. Detailed neutronics and thermal-fluidic analyses were performed to develop a reference core design. Region-dependent 33-group cross sections were generated based on the ENDF/B-VII.0 data using the MC2-3 code. Core and fuel cycle analyses were performed in theta-r-z geometries using the DIF3D and REBUS-3 codes. Reactivity coefficients and kinetics parameters were calculated using the VARI3D perturbation theory code. Thermo-fluidic analyses were performed using the ANSYS FLUENT computational fluid dynamics (CFD) code. Figure 0.1 shows a schematic radial layout of the reference 1000 MWt SLFFR core, and Table 0.1 summarizes the main design parameters of SLFFR-1000 loop plant. The fuel container is a 2.5 cm thick cylinder with an inner radius of 87.5 cm. The fuel container is penetrated by twelve hexagonal control assembly (CA) guide tubes, each of which has 3.0 mm thickness and 69.4 mm flat-to-flat outer distance. The distance between two neighboring CA guide tube is selected to be 26 cm to provide an adequate space for CA driving systems. The fuel container has 18181 penetrating coolant tubes of 6.0 mm inner diameter and 2.0 mm thickness. The coolant tubes are arranged in a triangular lattice with a lattice pitch of 1.21 cm. The fuel, structure, and coolant volume fractions inside the fuel container are 0.386, 0.383, and 0.231, respectively. Separate steel reflectors and B4C shields are used outside of the fuel container. Six gas expansion modules (GEMs) of 5.0 cm thickness are introduced in the radial reflector region. Between the radial reflector and the fuel container is a 2.5 cm sodium gap. The TRU inventory at the beginning of equilibrium cycle (BOEC) is 5081 kg, whereas the TRU inventory at the beginning of life (BOL) was 3541 kg. This is because the equilibrium cycle fuel contains a significantly smaller fissile fraction than the LWR TRU feed. The fuel inventory at BOEC is composed of 34.0 a/o TRU, 41.4 a/o Ce, 23.6 a/o Co, and 1.03 a/o solid fission products. Since uranium-free fuel is used, a theoretical maximum TRU consumption rate of 1.011 kg/day is achieved. The semi-continuous fuel cycle based on the 300-batch, 1- day cycle approximation yields a burnup reactivity loss of 26 pcm/day, and requires a daily reprocessing of 32.5 kg of SLFFR fuel. This yields a daily TRU charge rate of 17.45 kg, including a makeup TRU feed of 1.011 kg recovered from the LWR used fuel. The charged TRU-Ce-Co fuel is composed of 34.4 a/o TRU, 40.6 a/o Ce, and 25.0 a/o Co.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Inherent safety of minimum-burnup breed and burn reactors

Reactors that aim to sustain the breed and burn (B and B) mode of operation at minimum discharge burnup require excellent neutron economy, Minimum-burnup B and B cores are generally large and feature low neutron leakage probability and a hard neutron spectrum. While highly promising fuel cycles can be achieved with such designs, the very same features are pushing the limits of the core's ability to passively respond safely to unprotected accidents. Low leakage minimum-burnup sodium-cooled B and B cores have a large positive coolant void-worth and coolant temperature reactivity coefficient. In this study, the applicability of major approaches for fast reactor void-worth reduction is evaluated specifically for B and B cores. The design, shuffling scheme and performance of a new metallic-fueled, sodium-cooled minimum burnup B and B core, used as basis for the void-worth reduction analysis, is presented. The analysis shows that reactivity control systems based on passive {sup 6}Li injection during temperature excursions are the only option able to provide negative void-worth without significantly increasing the minimum burnup required for sustaining the B and B mode of operation. A new type of lithium expansion module (LEM) system was developed specifically for B and B cores and its effect on core performance is presented. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Review of Pump Package Assembly Anomalies and Demonstration to Gain Motor Controller Replacement Capability

The International Space Station (ISS) generates heat within the US modules from systems used to operate the station, maintain crew health, and conduct science experiments in the orbiting laboratory. The Internal Thermal Control System (ITCS) collects this heat in water loops and transfers it to the external ammonia system for rejection to space. The ITCS uses six Pump Package Assemblies (PPA) as the motive force to circulate the water within the Lab, Node 2, and Node 3 (Node 1 is parasitic to the Lab and Node 3 ITCS loops). In the life of ISS, 3 PPAs have had to be replaced and 2 PPAs are currently showing signs of degradation. The first PPA to fail in 2003 was due to early coolant chemistry issues; the remaining pump failures and current pump degradations are determined to be related to the Pump/Fan Motor Controller (PFMC), with their individual signatures all being unique to this point. The PFMC of one of the failed PPAs was returned and testing confirmed its sub-components to be the root cause of the PPA failure. Due to the relative size and weight of the standalone PFMC in comparison to the integrated assembly, it is desired, from a launch and on-orbit stowage perspective, to replace the PFMC component of the degraded PPA instead of the entire PPA. The PPA was not designed for this capability, so on the ground demonstrations are planned using crew tools to show that the PFMC can be replaced on-orbit while maintaining full functionality. This paper will focus on the signatures of the two most recent PPA failures and the two PPAs showing signs of degradation, in addition to presenting the findings from the PFMC demonstration effort.

Aaron Rodriguez↗

A Review of Pump Package Assembly Anomalies and Demonstration to Gain Motor Controller Replacement Capability

The International Space Station (ISS) generates heat within the US modules from systems used to operate the station, maintain crew health, and conduct science experiments in the orbiting laboratory. The Internal Thermal Control System (ITCS) collects this heat in water loops and transfers it to the external ammonia system for rejection to space. The ITCS uses six Pump Package Assemblies (PPA) as the motive force to circulate the water within the Lab, Node 2, and Node 3 (Node 1 is parasitic to the Lab and Node 3 ITCS loops). In the life of ISS, 3 PPAs have had to be replaced and 2 PPAs are currently showing signs of degradation. The first PPA to fail in 2003 was due to early coolant chemistry issues; the remaining pump failures and current pump degradations are determined to be related to the Pump/Fan Motor Controller (PFMC), with their individual signatures all being unique to this point. The PFMC of one of the failed PPAs was returned and testing confirmed its sub-components to be the root cause of the PPA failure. Due to the relative size and weight of the standalone PFMC in comparison to the integrated assembly, it is desired, from a launch and on-orbit stowage perspective, to replace the PFMC component of the degraded PPA instead of the entire PPA. The PPA was not designed for this capability, so on the ground demonstrations are planned using crew tools to show that the PFMC can be replaced on-orbit while maintaining full functionality. This paper will focus on the signatures of the two most recent PPA failures and the two PPAs showing signs of degradation, in addition to presenting the findings from the PFMC demonstration effort.

Aaron Rodriguez↗

Pump and Flow Control Subassembly of Thermal Control Subsystem for Photovoltaic Power Module

The pump and flow control subassembly (PFCS) is an orbital replacement unit (ORU) on the Space Station Freedom photovoltaic power module (PVM). The PFCS pumps liquid ammonia at a constant rate of approximately 1170 kg/hr while providing temperature control by flow regulation between the radiator and the bypass loop. Also, housed within the ORU is an accumulator to compensate for fluid volumetric changes as well as the electronics and firmware for monitoring and control of the photovoltaic thermal control system (PVTCS). Major electronic functions include signal conditioning, data interfacing and motor control. This paper will provide a description of each major component within the PFCS along with performance test data. In addition, this paper will discuss the flow control algorithm and describe how the nickel hydrogen batteries and associated power electronics will be thermally controlled through regulation of coolant flow to the radiator.

Motil, Brian↗

NRC Multiphysics Analysis Capability Deployment (FY2021 - Part 2)

This report details the progress and activities of Idaho National Laboratory (INL) on the Nuclear Regulatory Commission (NRC) project “Development and Modeling Support for Advanced Non-Light Water Reactors.” Task 4b was completed for this report. INL developed a sample problem showing how to use Serpent 2 to calculate macroscopic cross sections for use in Griffin for a typical sodium fast reactor Unprotected Loss of Flow (ULOF) transient. The complicating factor is the relatively large axial gradient of the coolant (and hence fuel) temperature and its evolution during the transient. A 3D Griffin model of the Advanced Burner Test Reactor (ABTR) is coupled to the System Analysis Module (SAM) to perform the ULOF transient. The model includes various explicit feedback mechanisms for fast reactors, including Doppler, radial expansion from the displacement of the support plate, and axial expansion from the displacement of the fuel pins. The results for the ULOF transient are consistent with published values. We observed small effects in the transient results that arise from the superhomogenization equivalence correction of uniform and nonuniform temperature data sets, but they diminish as more dominant reactivity mechanisms are added to the model. Potential improvements to the neutronics model include: adding the differential control rod and sodium feedback mechanisms, implementing cross section re-homogenization based on the partial volume of the various materials, and enhancing the kinetics parameters. Furthermore, the fluids model only includes four subchannels to represent the entire active core due to performance limitations in SAM when attempting to model one subchannel per assembly.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NuScale Power Module Instrumentation

The safe and efficient operation of any nuclear power plant (NPP) depends on accurate and timely measurement of the primary system temperature, pressure, level, flow, and neutron flux. Integral pressurized water reactor (iPWR) or small modular reactors (SMRs) present unique challenges to instrumentation and control (I&C) sensors and their maintenance strategies. More specifically, the calibration and response time of these sensors may have to be verified periodically to ensure that they maintain their required degree of accuracy and speed of response. A review of technical reports and safety analysis documentation of the NuScale Power Module (NPM) by Analysis and Measurement Services Corporation (AMS), together with NuScale engineers, confirms that the I&C sensors within the NPM will need to be testable as installed to verify their static and dynamic performance at plant operating conditions. Sensor placement and installation as well as the process conditions expected in natural circulation integral SMRs like the NPM are very different from those in large scale NPPs with conventional primary system loop piping. In particular, reactor coolant system (RCS) flows are more complex and flow rates much lower, the average containment temperature is higher, nuclear radiation levels in some areas are greater, and the accessibility of sensors for hands-on maintenance is very limited. These challenges among others related to I&C sensors can be overcome by adapting existing I&C sensor test methods, developing new techniques for non-conventional I&C sensors, and incorporating online monitoring (OLM) technologies into the I&C architecture of the plant to verify the calibration and response time of sensors within the NPM prior to startup, during operation, and during subsequent refueling outages. These methods and technologies will be demonstrated and validated through a research and development (R&D) grant recently awarded to AMS by the U.S. Department of Energy (DOE) to facilitate timely deployment of the first NuScale SMR in the United States and to enable efficient I&C maintenance strategies during the life of the plant. Lastly, this paper presents the R&D plan for the DOE project with a focus on temperature measurement needs of NuScale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗