Multistage Passive Cooler for Spaceborne Instruments

A document describes a three-stage passive radiative cooler for a cryogenic spectrometer to be launched into a low orbit around the Moon. This cooler is relatively lightweight and compact, and its basic design is scalable and otherwise adaptable to other applications in which there are requirements for cooling instrumentation in orbit about planets. The cooler includes multiple lightweight flat radiator blades alternating with cylindrical parabolic infrared reflectors. The radiator blades are oriented at an angle chosen to prevent infrared loading from the Moon limb at the intended orbital altitude and attitude. The reflectors are shaped and oriented to position their foci outside the radiator surfaces. There are six radiator-blade/reflector pairs - two pairs for each stage of cooling. The radiator blades and reflectors are coated on their front and back surfaces with materials having various infrared emissivities, infrared reflectivities, and solar reflectivities so as to maximize infrared radiation to cold outer space and minimize inadvertent solar heating. The radiator blades and reflectors are held in place by a lightweight support structure, the components of which are designed to satisfy a complex combination of thermal and mechanical requirements.

Rodriquez, Jose I.↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler Using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application: Preprint

Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Design of a Microbunched Electron Cooler Energy Recovery Linac

Microbunched electron Cooling (MBEC), a type of Coherent electron Cooling (CeC), is a possible way to cool high energy protons; such an electron cooler can be driven by an energy recovery linac (ERL). The beam parameters of this design are based on cooling 275 and 100 GeV protons at the Electron-Ion Collider (EIC), requiring 150 and 55 MeV electrons, respectively. If implemented, a high energy cooler would serve to increase the average luminosity of the collider by mitigating the emittance growth caused by various processes. This ERL is designed to deliver a bunch charge of 1 nC, an average current of 100 mA, and strict requirements on the transverse emittance, slice energy spread, and longitudinal distribution profile. This paper covers the current state of the design.

Accelerator Physics↗

20 K continuous cycle sorption coolers for the Planck flight mission

In this paper we present the level of maturity of the hydrogen sorption cooler technology at JPL by describing the design and how it has been validated at the subsystem and system levels. In addition, we will describe how such systems could be advantageously used for other space missions with similar needs and cooler attributes.

sorption cooler 20 K hydride Planck↗

Cryogenic testing of Planck sorption cooler test facility

A test facility has been upgraded in preparation for testing of two hydrogen sorption cryocoolers operating at 18/20 K. these sorption coolers are currently under development at the Jet Propulsion Laboratory. This work summarizes the scope of the test facility upgrade, including design for cryogenic cooling power delivery, system thermal management, insulation schemes, and data acquisition techniques. Ground support equipment for the sorption coolers, structural features of the test chamber, and the vacuum system involved for system testing will also be described in detail.

Planck sorption cooler↗

Off-line commissioning of the St. Benedict radiofrequency quadrupole cooler-buncher

The St. Benedict ion trapping system, which aims to measure the β - v angular correlation parameter in superallowed-mixed mirror transitions, is under construction at the University of Notre Dame. These measurements will provide much-needed data to improve the accuracy of the V ud element of the CKM matrix. One of the major components of this system is the radio frequency quadrupole cooler-buncher, which is necessary to create low-emittance ion bunches for injection into the measurement Paul trap. The off-line commissioning of the cooler-buncher, using a potassium ion source, determined that the device could produce cooled ion bunches characterized by a 50-ns full-width-half-maximum time width at its exit. The commissioning results also determined the trapping efficiency to be 93(1)% and the trapping half-life to be 20.0(5) s.

Paul trap↗

Reliability of Copper Inverse Opal Surfaces for Extreme-Heat-Flux Micro-Coolers in Low-Global-Warming-Potential Refrigerant R-1233zd Pool Boiling Experiments

This presentation provides a brief snapshot of the InterPACK paper InterPACK2023-113781. The paper explores copper inverse opal (CIO) surface reliability in pool boiling experiments in water and a new, low-global-warming-potential (GWP = 1) hydrofluoroolefin (HFO) refrigerant R-1233zd. The CIO-based structure is intended to develop enhanced two-phase heat transfer surfaces for extreme-heat-flux (approximately 1 kW/cm2) micro-coolers. In this study, a limited number of pool boiling experiments were performed using water and HFO-1233zd fluid, and the reliability of the CIO-based surfaces was evaluated. Critical heat flux (CHF) values in HFO-1233zd at 40 Degrees Celsius to 45 Degrees Celsius saturation temperatures and the corresponding saturation pressures were also measured. The CHF values with the refrigerant are significantly lower compared to those with water, but the refrigerant allows for a wider usable temperature range in the end application of the micro-coolers and is not limited to data centers with controlled ambient conditions. Reliability experiments with CIO surface samples - involving pool boiling with water on the CIO surfaces for approximately 48 hours and with HFO-1233zd for 144 hours - showed no structural degradation of the enhanced surface or any significant performance drop in heat transfer coefficients. The CIO surface samples in water were oxidized, most likely due to the presence of air in water and in the experimental vessel.

critical heat flux↗

Ion Trapping Studies and Mitigation Strategies for the EIC ERL-Based Strong Hadron Cooler

An Energy Recovery Linac based strong hadron cooler was previously considered for the Electron-Ion Collider. The required electron beam parameters for variable-energy strong hadron cooling place significant constraints on ion trapping and collective effects. This paper presents initial studies of these constraints through a combination of analytical modelling and numerical simulations of ion production, trapping behaviour, and mitigation strategies. A multi-bunch tracking framework based on ELEGANT with the ionEffects module is used to simulate machine operation over millisecond time scales, corresponding to more than 3 × 10^5 electron bunches. The simulations include modelling of ionisation processes together with transverse electron–ion dynamics, allowing the evolution and accumulation of ions to be investigated. Analytical expressions based on Gaussian beam distributions are used to estimate ion trapping conditions and benchmark the simulation results. A bi-periodic bunch spacing scheme is also investigated as a possible mitigation method by detuning the ion oscillation frequency. These studies provide an initial assessment of ion trapping in the strong hadron cooler and demonstrate possible approaches for reducing beam–ion effects.

Bi, R. [Lancaster University, Cockcroft Institute]↗

Design of a microbunched electron cooler energy recovery linac

Microbunched electron Cooling (MBEC), a type of Coherent electron Cooling (CeC), is a possible way to cool high energy protons; such an electron cooler can be driven by an energy recovery linac (ERL). The beam parameters of this design are based on cooling 275 and 100 GeV protons at the Electron-Ion Collider (EIC), requiring 150 and 55 MeV electrons, respectively. If implemented, a high energy cooler would serve to increase the average luminosity of the collider by mitigating the emittance growth caused by various processes. This ERL is designed to deliver a bunch charge of 1 nC, an average current of 100 mA, and strict requirements on the transverse emittance, slice energy spread, and longitudinal distribution profile. This paper covers the current state of the design.

Accelerator Physics↗

Design of a Microbunched Electron Cooler Energy Recovery Linac

Microbunched electron Cooling (MBEC), a type of Coherent electron Cooling (CeC), is a possible way to cool high energy protons; such an electron cooler can be driven by an energy recovery linac (ERL). The beam parameters of this design are based on cooling 275 and 100 GeV protons at the Electron-Ion Collider (EIC), requiring 150 and 55\,MeV electrons, respectively. If implemented, a high energy cooler would serve to increase the average luminosity of the collider by mitigating the emittance growth caused by various processes. This ERL is designed to deliver a bunch charge of 1\,nC, an average current of 100\,mA, and strict requirements on the transverse emittance, slice energy spread, and longitudinal distribution profile. This paper covers the current state of the design.

Deitrick, K. [Thomas Jefferson National Accelerato↗

Design Overview of the Strong Hadron Cooler ERL at the Electron-Ion Collider

The Electron-Ion Collider (EIC) is currently under development to be built at Brookhaven National Lab and requires cooling during collisions in order to preserve the quality of the hadron beam despite degradation due to intra-beam scattering and beam-beam effect. An Energy Recovery Linac (ERL) is being designed to deliver the necessary electron beam for Coherent electron Cooling (CeC) of the hadron beam, with an electron bunch charge of 1 nC and an average current of 100 mA; two modes of operation are being developed for 150 and 55 MeV electrons, corresponding to 275 and 100 GeV protons. The injector of this Strong Hadron Cooler ERL (SHC-ERL) is shared with the Injection Cooler ERL, which cools lower energy proton beams via bunched beam cooling, as used in the Low Energy RHIC electron Cooling (LEReC). This talk introduces the layout and presents a high-level overview of the design.

Deitrick, K.↗

Development of thermal energy storage units for spacecraft cryogenic coolers

Thermal Energy Storage Units were developed for storing thermal energy required for operating Vuilleumier cryogenic space coolers. In the course of the development work the thermal characteristics of thermal energy storage material was investigated. By three distinctly different methods it was established that ternary salts did not release fusion energy as determined by ideality at the melting point of the eutectic salt. Phase change energy was released over a relatively wide range of temperature with a large change in volume. This strongly affects the amount of thermal energy that is available to the Vuilleumier cryogenic cooler at its operating temperature range and the amount of thermal energy that can be stored and released during a single storage cycle.

Richter, R.↗

NASA low and ultralow temperature cryogenic cooler systems for space missions

The paper describes the NASA research program to provide low and ultralow temperature cryogenic cooler systems for future space missions. These include mechanical, solid cryogen, superfluid helium, helium-3, and helium-3/helium-4 dilution coolers, and all systems must function in the zero gravity environment of space. The temperatures produced range from tens of kelvin down to a few millikelvin; at higher temperatures cooling loads for sensors or detectors and associated sun shields may range up to a few watts. At the ultralow temperature end, cooling loads must be limited to tens of microwatts.

Lundholm, J. G., Jr.↗

Cryogenic cooling of instruments in orbit - A standard solid cryogen cooler approach

A study has been conducted to determine the utility and characteristics of a solid cryogen cooler which could meet a variety of instrument and mission requirements. The cooler consists essentially of two stages of solid cryogen and two cooled shields. The inner shield is thermally grounded to the secondary (warmer) cryogen and provides a low temperature boundary around the colder primary stage, while the outer shield reduces the heat loads upon the secondary cryogen. The baseline design provides cooling of approximately 1 watt over the temperature range 60-100 K, 0.5 watts from 15 to 60 K, and 0.2 watts from 8 to 15 K for a one-year lifetime. For low cooling loads (0.1 W) and with use of an optional cooled shield, cooling lifetimes of 8 years are possible.

Nast, T. C.↗

Study of a solid hydrogen cooler for spacecraft instruments and sensors

The results of tests and studies to investigate the utilization of solid hydrogen for cooling of spacecraft instruments and sensors are presented. The results are presented in two sections; the first describing the tests in which an existing single stage solid cooler was filled and tested with solid hydrogen and the second which describes the analysis and design of a catalytic converter which will be tested in the vent line of the cooler.

Sherman, A.↗

Advanced radiative cooler with angled shields

Recent demands for spaceborne sensor temperatures below 90 K are exceeding the capabilities of present passive radiative cooler designs. To improve cooling performance, a novel technique was developed to radiatively and conductively isolate the radiating plate from the spacecraft using low-emittance, highly specular angled radiation shields. An experimental test of the new shield concept verified its effectiveness and enabled calibration of a detailed thermal model. Based on the concept test results, performance predictions show that the Advanced Radiator can achieve lower temperatures, deliver more cooling power and be smaller and lighter than the best state-of-the-art coolers.

Bard, S.↗

Molecular absorption cryogenic cooler for liquid hydrogen propulsion systems

A light weight, long life molecular absorption cryogenic cooler (MACC) system is described which can use low temperature waste heat to provide cooling for liquid hydrogen propellant tanks for interplanetary spacecraft. Detailed tradeoff studies were made to evaluate the refrigeration system component interactions in order to minimize the mass of the spacecraft cooler system. Based on this analysis a refrigerator system mass of 31 kg is required to provide the .48 watts of cooling required by a 2.3 meter diameter liquid hydrogen tank.

Klein, G. A.↗

Sealing Mechanical Cryogenic Coolers

Metal bellows used to seal Vuilleumier and Stirling-cycle cryogenic coolers, replacing sliding seals that failed after only 3,000 hours of service. Metal bellows, incorporated in displacer design provide nonrubbing dynamic seal. Lifetime of cryogenic cooler no longer limited by loss of sealing material and by deterioration of regenerators due to clogging by seal debris.

Richter, R.↗