Search NASA⌕ Search

SEARCH · Search NASA

Results for “counter electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Electrospray Collection of Lunar Dust

A report describes ElectroSpray Ionization based Electrostatic Precipitation (ESIEP) for collecting lunar dust particles. While some HEPA filtration processes may remove a higher fraction (>99.9 percent) of the particles, the high efficiency may not be appropriate from an overall system standpoint, especially in light of the relatively large power requirement that such systems demand. The new electrospray particle capture technology is described as a variant of electrostatic precipitation that eliminates the current drawbacks of electrostatic precipitation. The new approach replaces corona prone field with a mist of highly charged micro-droplets generated by electrospray ionization (ESI) as the mechanism by which incoming particles are attracted and captured. In electrospray, a miniscule flow rate (microliters/minute) of liquid (typically water and a small amount of salt to enhance conductivity) is fed from the tip of a needle held at a high voltage potential relative to an opposite counter electrode. At sufficient field strength, a sharp liquid meniscus forms , which emits a jet of highly charged droplets that drift through the surrounding gas and are collected on the walls of a conductive tube. Particles in the gas have a high probability of contact with the droplets either by adhering to the droplets or otherwise acquiring a high level of charge, causing them to be captured on the collecting electrode as well. The spray acts as a filtration material that is continuously introduced and removed from the gas flow, and thus can never become clogged.

Dziekan, Michael↗

Evaluation testing of a portable vapor detector for Part-Per-Billion (PPB) level UDMH and N2H4

Trace level detection of hydrazine (N2H4), monomethyl hydrazine (MMH) and unsymmetrical dimethylhydrazine (UDMH) has been receiving increased attention over the past several years. In May 1995 the American Conference of Government Industrial Hygienists (ACGIH) lowered their acceptable threshold limit value (TLV) from 100 parts-per-billion (ppb) to 10 ppb. Several types of ppb-level detectors are being developed by the United States Air Force (USAF) Space and Missile Systems Center (SMSC). A breadboard version of a portable, lightweight hydrazine detection sensor was developed and produced by Giner Corp. for the USAF. This sensor was designed for ppb level UDMH and N2H4 vapor detection in near real-time. This instrument employs electrochemical sensing, utilizing a three electrode cell with an anion-exchange polymer electrolyte membrane as the only electrolyte in the system. The sensing, counter and reference electrodes are bonded to the membrane forming a single component. The only liquid required to maintain the sensor is deionized water which hydrates the membrane. At the request of the USAF SMSC, independent testing and evaluation of the breadboard instrument was performed at NASA's Toxic Vapor Detection Laboratory (TVDL) for response to ppb-level N2H4 and UDMH and MMH. The TVDL, located at Kennedy Space Center (KSC) has the unique ability to generate calibrated sample vapor streams of N2H4, UDMH, and MMH over a range from less than 10 ppb to thousands of parts per million (ppm) with full environmental control of relative humidity (0-90%) and temperature (0-50 C). The TVDL routinely performs these types of tests. Referenced sensors were subjected to extensive testing, including precision, linearity, response/recovery times, zero and span drift, humidity and temperature effects as well as ammonia interference. Results of these tests and general operation characteristics are reported.

Curran, Dan↗

In Situ Liquid Electron Microscope Cells Strongly Attenuate Electrochemical Behavior

In situ electrochemical Scanning Transmission Electron Microscopy (ec-S/TEM) probes the dynamics of electrochemical processes in real time and at high spatial resolution. This method utilizes microfabricated electrochemical cells, with enclosed dimensions of 800 μm wide, 800 μm long, and 1–2 μm tall, with electron-transparent silicon nitride windows. Working, counter, and reference electrodes in the configuration studied are deposited Pt with a planar surface area of about 1 μm 2 and a height of 50 nm. The cell confines the electrolyte within a 1 μm tall channel, and the microfabricated electrodes have a non-standard geometry, are coplanar, and are not front-facing. As such, standard assumptions of electrochemical experiments do not apply. COMSOL modeling was used to compare and contrast differences in electrochemical behavior between conventional experimental setups and the in situ ec-S/TEM cells. Cell height strongly affected voltammogram measurements: peak magnitudes and shifts correlate directly to cell height. Reactant concentration above the electrode quickly decreases during deposition, leading to a planar diffusion-dominated regime. The concentration gradient prioritizes particle growth along the thin edges of the electrode and not on the planar part of the electrode. Experiments done in the ec-S/TEM ex situ of a TEM verify the model’s accuracy.

Wittman, Reed M. [Oak Ridge National Laboratory (O↗

The microstrip proportional counter

Microstrip detectors in which the usual discrete anode and cathode wires are replaced by conducting strips on an insulating or partially insulating substrate are fabricated using integrated circuit-type photolithographic techniques and hence offer very high spatial accuracy and uniformity, together with the capability of producing extremely fine electrode structures. Microstrip proportional counters have now been variously reported having an energy resolution of better than 11 percent FWHM at 5.9 keV. They have been fabricated with anode bars down to 2 microns and on a variety of substrate materials including thin films which can be molded to different shapes. This review will examine the development of the microstrip detector with emphasis on the qualities which make this detector particularly interesting for use in astronomy.

Ramsey, B. D.↗

Applications of Gas Imaging Micro-Well Detectors to an Advanced Compton Telescope

We present a concept for an Advanced Compton Telescope (ACT) based on the use of pixelized gas micro-well detectors to form a three-dimensional electron track imager. A micro-well detector consists of an array of individual micro-patterned proportional counters opposite a planar drift electrode. When combined with thin film transistor array readouts, large gas volumes may be imaged with very good spatial and energy resolution at reasonable cost. The third dimension is determined by timing the drift of the ionization electrons. The primary advantage of this approach is the excellent tracking of the Compton recoil electron that is possible in a gas volume. Such good electron tracking allows us to reduce the point spread function of a single incident photon dramatically, greatly improving the imaging capability and sensitivity. The polarization sensitivity, which relies on events with large Compton scattering angles, is particularly enhanced. We describe a possible ACT implementation of this technique, in which the gas tracking volume is surrounded by a CsI calorimeter, and present our plans to build and test a small prototype over the next three years.

Bloser, P. F.↗

Electrochemical detection device

A standard pH reference electrode and a platinum cathodic electrode are positioned in a container with suitable nutrient medium for microbial growth plus the sample to be tested. The two electrodes are connected to electronic circuitry including an up/down counter whicn counts up for the first 80 minutes after a test has initiated. Then the potential between the two electrodes is tracked by the electronic circuitry and after there is a change of 10 mv a signal is sent to the up/down counter to cause it to reverse its count. When there is a additional 20 mv change in the potential between the two electrodes another signal is sent to the up/down counter, signalling it to stop. The resulting count on the counter is equal to the length of time for the inoculum to begin the production of measurable amounts of H2 after inoculation.

Young, R. N.↗

Novel plasma actuator for mitigation of dynamic stall

A novel plasma actuator, the Linear Counter-flow using a Point Embedded Electrode (LCPEE), is developed for the prevention of dynamic stall for a sinusoidal pitching movement between α = 4° and α = 18°. The LCPEE is implemented on a NACA0012 airfoil and tested at a Reynolds Number of Re c = 2 × 105 and reduced frequency of k = π/16. Prior investigations using a standard linear actuator showed that the exposed electrode introduced perturbations passively which delayed dynamic stall when the actuator was off. For the LCPEE actuator, when turned off, there is least passive delay. When the LCPEE is turned on at St f = 50, the dynamic stall is prevented for the sinusoidal pitching motion of the airfoil. The LCPEE actuator is also tested for the same sinusoidal motion between α = 6° and α = 20°. Four cases are considered for the higher α range of motion: actuator off, actuator on at St f = 50 with a sinusoidal input waveform, actuator on at St f = 50 with a triangular input waveform, and actuator on at Stf = 100 with a sinusoidal input waveform. Specifically for the last case, experiment shows no flow reversal demonstrating the efficacy of LCPEE in controlling the dynamic stall. The effects of LCPEE on the flow energy distribution have also been studied by using proper orthogonal decomposition (POD) method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Double ChemFET for the In-Line Monitoring of Silver Dosing in Potable Water Systems

With NASA Advanced Exploration Systems (AES) Life Support Systems (LSS) baselining ionic silver (Ag+) as the biocide of choice, development in silver monitoring technologies becomes necessary to monitor and control Ag+ release. Ion-selctive field effect transistors (ISFETs) and chemically-sensitive field effect transistors (ChemFETs) are capable of selective detection of Ag+ with reversible and low detection limit responses. However, one major hurdle to ChemFET technologies is the requirement of a reference electrode, which can leak its fill solution into the potable water system and is prone to drift requiring frequent calibration. To circumvent this issue, we are developing a double chemically-sensitive field effect transistor (dChemFET). The dChemFET uses a second ChemFET to selectively monitor the counter ion and serves in place of the reference electrode. We report our work in developing the dChemFET, starting with the development of the Ag+ and NO3- ion selective memberanes (ISMs) to be used in the ChemFETs. The Ag+ ISM has a detection range of 50-105 ppb . The counter ion ISM, NO3- ISM, has shown a detection range of 400-105 ppb. NO3- ISMs are limited in detecting at lower ppb levels required for the dChemFET application on the potable water system. In response to this issue, we also report our studies in using the Ag+ ISM to measure deionized (DI) water as a reference measurement to be implemented in-line before the Ag+ is dosed.

Lance Dean Delzeit↗

Double ChemFET for the In-Line Monitoring of Silver Dosing in Potable Water Systems

With NASA Advanced Exploration Systems (AES) Life Support Systems (LSS)baselining ionic silver (Ag+) as the biocide of choice, development in silver monitoring technologies becomes necessary to monitor and control Ag+ release. Ion-selective field effect transistors (ISFETs) and chemically-sensitive field effect transistors (ChemFETs) are capable of selective detection of Ag+ with reversible and low detection limit responses. However, one major hurdle to ChemFET technologies is the requirement of a reference electrode, which can leak its fill solution into the potable water system and is prone to drift requiring frequent calibration. To circumvent this issue, a double chemically-sensitive field effect transistor (dChemFET) is proposed. The dChemFET uses a second ChemFET to selectively monitor the counter ion and serves in place of the reference electrode. This work reports on the development of the dChemFET, starting with the development of the Ag+ andNO3- ion selective membranes (ISMs) to be used in the ChemFETs. The Ag+ ISM was tested in 50-105 ppb Ag+ and showed linear, sub-Nernstian response. The NO3- ISM was tested in50-500 ppb silver ion equivalents of nitrate ion (Ag+ equiv. of NO3-) and shows linear, sub-Nernstian response as well . However, the Ag+ and NO3- ISMs face significant challenges in terms of drift that obstruct its application for long-term monitoring, but it can serve as a starting point for demonstrating the dChemFET proof of concept.

John Abdou↗

Modeling of surface-state induced inter-electrode isolation of n -on- p devices in mixed-field and γ -irradiation environments

Position sensitive n-on-p silicon sensors will be utilized in the tracker and in the High Granularity Calorimeter (HGCAL) of the Compact Muon Solenoid (CMS) experiment at High Luminosity Large Hadron Collider (HL-LHC). The detrimental effect of the radiation-induced accumulation of positive net oxide charge on position resolution in n-on-p sensors has typically been countered by the application of isolation implants like p-stop or p-spray between n + -electrodes. In addition to the positively charged layer inside the oxide and close to the Si/SiO 2 -interface, surface damage introduced by ionizing radiation in SiO 2 -passivated silicon particle detectors includes the accumulation of trapped-oxide-charge and interface traps. A previous study of either n/γ (mixed field)- or γ-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed evidence of substantially higher introduction rates of acceptor- and donor-type deep interface traps (N it,acc/don ) in mixed-field environment. Here, in this work, an inter-pad and -strip resistance (or resistivity (ρ int )) simulation study of n-on-p sensors with and without p-stop isolation implants was conducted for both irradiation types. Higher levels of ρint showed correlation to higher densities of deep N it,acc/don , with the inter-pad isolation performance of the mixed-field irradiated sensors becoming independent of the presence of p-stop implant between the n + - electrodes up to about 100 kGy. The low introduction rates of deep N it,acc/don in γ-irradiated sensors resulted in high sensitivity of ρ int to the presence and peak doping of p-stop above the lowest dose of about 7 kGy in the study. As a consequence of the advantageous influence of radiation-induced accumulation of deep N it on the inter-electrode isolation, position sensitive n-on-p sensors without isolation implants may be considered for future HEP-experiments where the radiation is largely due to hadrons.

Akchurin, N. [Texas Tech Univ., Lubbock, TX (Unite↗

Electrochemical studies of thin films of conducting polymers and conducting polymer composites deposited on metal and semiconductor electrodes

Electrochemical studies indicate that poly(Isothianaphthene) or PITN, can be p-doped only. Electrochemical properties of PITN and Nafion-PITN in acetonitrile solutions containing tetra-phenyl Phosphonium chloride as supporting electrolyte are compared. In both cases, the electrochemical behavior of thin films are different from that of thick films. In addition, Nafion does not seem to alter the electrochemical properties of PITN. Cyclic voltammetric and chronocoulometric measurements were made to compute the diffusion coefficient of the counter ions. Electrochemical behavior of both PITN and Nafion-PITN in acetonitrile solution containing different counter ions are described. PITN, when electrochemically deposited, apparently neither passivates surface states present nor forms ohmic contacts with p-Si or p(+)Si single-crystal electrodes.

Nagasubramanian, G.↗

Macular Bioaccelerometers on Earth and in Space

Space flight offers the opportunity to study linear bioaccelerometers (vestibular maculas) in the virtual absence of a primary stimulus, gravitational acceleration. Macular research in space is particularly important to NASA because the bioaccelerometers are proving to be weighted neural networks in which information is distributed for parallel processing. Neural networks are plastic and highly adaptive to new environments. Combined morphological-physiological studies of maculas fixed in space and following flight should reveal macular adaptive responses to microgravity, and their time-course. Ground-based research, already begun, using computer-assisted, 3-dimensional reconstruction of macular terminal fields will lead to development of computer models of functioning maculas. This research should continue in conjunction with physiological studies, including work with multichannel electrodes. The results of such a combined effort could usher in a new era in understanding vestibular function on Earth and in space. They can also provide a rational basis for counter-measures to space motion sickness, which may prove troublesome as space voyager encounter new gravitational fields on planets, or must re-adapt to 1 g upon return to earth.

Ross, M. D.↗

A long-range and long-life telemetry data-acquisition system for heart rate and multiple body temperatures from free-ranging animals

The system includes an implantable transmitter, external receiver-retransmitter collar, and a microprocessor-controlled demodulator. The size of the implant is suitable for animals with body weights of a few kilograms or more; further size reduction of the implant is possible. The ECG is sensed by electrodes designed for internal telemetry and to reduce movement artifacts. The R-wave characteristics are then specifically selected to trigger a short radio frequency pulse. Temperatures are sensed at desired locations by thermistors and then, based on a heartbeat counter, transmitted intermittently via pulse interval modulation. This modulation scheme includes first and last calibration intervals for a reference by ratios with the temperature intervals to achieve good accuracy even over long periods. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as RF interference.

Lund, G. F.↗

Enhancement of Otolith Specific Ocular Responses Using Vestibular Stochastic Resonance

Introduction: Astronauts experience disturbances in sensorimotor function after spaceflight during the initial introduction to a gravitational environment, especially after long-duration missions. Our goal is to develop a countermeasure based on vestibular stochastic resonance (SR) that could improve central interpretation of vestibular input and mitigate these risks. SR is a mechanism by which noise can assist and enhance the response of neural systems to relevant, imperceptible sensory signals. We have previously shown that imperceptible electrical stimulation of the vestibular system enhances balance performance while standing on an unstable surface. Methods: Eye movement data were collected from 10 subjects during variable radius centrifugation (VRC). Subjects performed 11 trials of VRC that provided equivalent tilt stimuli from otolith and other graviceptor input without the normal concordant canal cues. Bipolar stochastic electrical stimulation, in the range of 0-1500 microamperes, was applied to the vestibular system using a constant current stimulator through electrodes placed over the mastoid process behind the ears. In the VRC paradigm, subjects were accelerated to 216 deg./s. After the subjects no longer sensed rotation, the chair oscillated along a track at 0.1 Hz to provide tilt stimuli of 10 deg. Eye movements were recorded for 6 cycles while subjects fixated on a target in darkness. Ocular counter roll (OCR) movement was calculated from the eye movement data during periods of chair oscillations. Results: Preliminary analysis of the data revealed that 9 of 10 subjects showed an average increase of 28% in the magnitude of OCR responses to the equivalent tilt stimuli while experiencing vestibular SR. The signal amplitude at which performance was maximized was in the range of 100-900 microamperes. Discussion: These results indicate that stochastic electrical stimulation of the vestibular system can improve otolith specific responses. This will have a significant impact on development of vestibular SR delivery systems to aid recovery of function in astronauts after long-duration spaceflight or in people with balance disorders.

Fiedler, Matthew↗

Upgrades to the TRIUMF Fast Ion Counter, TRIFIC

TRIFIC, the TRIUMF Fast Ion Counter, is a downstream ionization chamber which provides beam composition monitoring and recoil tagging for in-beam reaction experiments. TRIFIC has been commissioned and deployed for use with radioactive isotope beams at the TRIUMF-ISAC facility. Recently, the detector has been upgraded to include an improved gas window that can accommodate higher beam rates and position-sensitive electrode grids for better position reconstruction.

Gaseous detectors↗

Eccentric exercise training as a countermeasure to non-weight-bearing soleus muscle atrophy

This investigation tested whether eccentric resistance training could prevent soleus muscle atrophy during non-weight bearing. Adult female rats were randomly assigned to either weight bearing +/- intramuscular electrodes or non-weight bearing +/- intramuscular electrodes groups. Electrically stimulated maximal eccentric contractions were performed on anesthetized animals at 48-h intervals during the 10-day experiment. Non-weight bearing significantly reduced soleus muscle wet weight (28-31 percent) and noncollagenous protein content (30-31 percent) compared with controls. Eccentric exercise training during non-weight bearing attenuated but did not prevent the loss of soleus muscle wet weight and noncollagenous protein by 77 and 44 percent, respectively. The potential of eccentric exercise training as an effective and highly efficient counter-measure to non-weight-bearing atrophy is demonstrated in the 44 percent attenuation of soleus muscle noncollagenous protein loss by eccentric exercise during only 0.035 percent of the total non-weight-bearing time period.

Kirby, Christopher R.↗

Microstrip proportional counter development at MSFC

Microstrip detectors are an exciting new development in proportional counter design fabricated using integrated circuit-type photolithography techniques; they therefore offer very high spatial accuracy and uniformity. A development program is underway at NASA-Marshall to produce large-area microstrips for use in an X-ray detector balloon flight program and to investigate the general performance limits of these new devices. Microstrips tested so far have been fabricated both in-house using standard photolithographic techniques and by an outside contractor using electron beam technology. Various substrate materials have been tested along with different electrode configurations. The distributions of pickup on subdivided cathodes on both top and bottom surfaces of the microstrips are also being investigated for use as two-dimensional imaging detectors. Data from these tests in the development of a large-area device will be presented.

Fulton, M. A.↗