Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryocooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

The Psyche Gamma-Ray and Neutron Spectrometer

A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program Psyche mission to the M-class asteroid (16) Psyche. The GRNS instrument is designed to measure the elemental composition of Psyche with the goal to understand the origin of this mysterious, potentially metal-rich planetary body. The GRNS will measure the near-surface abundances for the elements Ni, Fe, Si, K, S, Al, and Ca, as well as the spatial distribution of Psyche’s metal-to-silicate fraction (or metal fraction). These measurements address three of the five Psyche mission science objectives: determine if Psyche is a core; determine whether small metal bodies incorporate light elements into the metal phase; and determine whether Psyche was formed under reducing conditions. The Gamma-Ray Spectrometer (GRS) uses a cryocooled, high-purity Ge (HPGe) sensor to detect cosmic-ray generated gamma rays in the 60 to 9000-keV energy range. The HPGe sensor is surrounded by a borated plastic anticoincidence shield that provides three functions: active background rejection from charged particle interactions in the HPGe sensor; fast neutron measurements; and direct measurements of the incident galactic cosmic ray flux. The Neutron Spectrometer (NS) uses three 3 He gas proportional sensors, each with different material wraps to measure thermal (<0.4 eV), low-energy epithermal (0.4 eV to 1 keV), and high-energy epithermal (up to 100 keV) neutrons. This paper provides an overview of the Psyche GRNS, including: its science and measurement objectives; the design of the instrument hardware, software, and operation; pre-launch performance measurements and its initial performance in space; and an overview of its data products and expected operation for different Psyche mission phases.

Engineering - Instrumentation related to nuclear s↗

A Field-Enhanced Conduction-Cooled Superconducting Cavity for High-Repetition-Rate Ultrafast Electron Bunch Generation

High-repetition-rate sources of bright electron bunches have a wide range of applications. They can directly be employed as probes in electron-scattering setups, or serve as a backbone for the generation of radiation over a broad range of the electromagnetic spectrum. This paper describes the development of a compact sub-Mega-electronvolt (sub-MeV) electron-source setup capable of operating at MHz repetition rates and forming sub-picosecond electron bunches with transverse emittance below 20 nm. The setup relies on a conduction-cooled superconducting single-cell resonator with its geometry altered to enhance the field at the surface of the emitter. The system is designed to accommodate cooling using a 2 W pulse-tube cryogen-free cryocooler operated at 4.2 K. Although we focus on the case of a photoemitted electron bunch, the scheme could be adapted to other emission mechanisms.

43 PARTICLE ACCELERATORS↗

Single-photon detection using high-temperature cuprate superconductors

The detection of individual quanta of light is important for quantum computation, fluorescence lifetime imaging, single-molecule detection, remote sensing, correlation spectroscopy, and more. Thanks to their broadband operation, high detection efficiency, exceptional signal-to-noise ratio, and fast recovery times, superconducting nanowire single-photon detectors (SNSPDs) have become a critical component in these applications. The operation of SNSPDs based on conventional superconductors, which have a low critical temperature (T c ), requires costly and bulky cryocoolers. This motivated exploration of other superconducting materials with higher T c that would enable single-photon detection at elevated temperatures, yet this task has proven exceedingly difficult. Here we show that with proper processing, high-T c cuprate superconductors can meet this challenge. We fabricated superconducting nanowires (SNWs) out of thin flakes of Bi 2 Sr 2 CaCu2O 8+δ and La 1.55 Sr 0.45 CuO 4 /La 2 CuO 4 (LSCO-LCO) bilayer films and demonstrated their single-photon response up to 25 and 8 K, respectively. The single-photon operation is revealed through the linear scaling of the photon count rate (PCR) on the radiation power. Both of our cuprate-based SNSPDs exhibited single-photon sensitivity at the technologically-important 1.5 μm telecommunications wavelength. Our work expands the family of superconducting materials for SNSPD technology, opens the prospects of raising the temperature ceiling, and raises important questions about the underlying mechanisms of single-photon detection by unconventional superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A high efficiency and low vibration liquid nitrogen cooling system for silicon crystal based x-ray optics

A compact low-cost cryocooling system has been designed, constructed, and tested at SLAC National Accelerator Laboratory. The cooling power is provided by natural convection and phase change of the liquid nitrogen. The initial application was to cool silicon crystal optics to the sub-100 K range. A silicon crystal of dimension (width × depth × height) 50 × 50 × 30 mm3 has been used with an electric heater on the top surface in this prototyping test. This system can effectively provide more than 80 W of cooling power to the optics with a consumption of liquid nitrogen less than 2.1 l/h. The vibration of the silicon crystal was monitored during the tests with added electric heater power on the crystal. We note the vibration of the silicon crystal due to liquid nitrogen boiling is negligible.

47 OTHER INSTRUMENTATION↗

A cryogenically cooled 200 kV DC photoemission electron gun for ultralow emittance photocathodes

Novel photocathode materials like ordered surfaces of single crystal metals, epitaxially grown high quantum efficiency thin films, and topologically non-trivial materials with dirac cones show great promise for generating brighter electron beams for various accelerator and ultrafast electron scattering applications. Despite several materials being identified as brighter photocathodes, none of them have been tested in electron guns to extract electron beams due to technical and logistical challenges. In this paper, we present the design and commissioning of a cryocooled 200 kV DC electron gun that is capable of testing a wide variety of novel photocathode materials over a broad range of temperatures from 298 to 35 K for bright electron beam generation. This gun is designed to enable easy transfer of the photocathode to various standard ultra-high-vacuum surface diagnostics and preparation techniques, allowing a full characterization of the dependence of beam brightness on the photocathode material and surface properties. We demonstrate the development of such a high-voltage, high-gradient gun using materials and equipment that are easily available in any standard university lab, making the development of such 200 kV electron guns more accessible.

Instruments & Instrumentation↗

Cryogenically enhanced quasi-optical resonator for megawatt pulsed millimeter-wave sources

We report the design, cryogenic optimization, and performance modeling of a compact quasi-optical ring resonator intended to compress microwaves pulses at 170 and 250 GHz to the megawatt level. By combining ultra-low-loss CVD diamond and gold-doped silicon wafers with high-RRR copper mirrors, the calculated unloaded quality factor exceeds 4.3 × 10 5 at 20 K and yields simulated gains up to $\mathscr{G}$ = 4.1 × 10 3 . Coupling the resonator with a laser-driven semiconductor switch described by an extended Vogel model shows that 1 MW, nanosecond pulses can be generated from only 445 W of microwave drive power while dissipating 272 W into the cryostat. A practical cooling architecture using two Gifford–McMahon stages (20 and 80 K) is proposed, demonstrating that high-repetition-rate (10–20 kHz) operation is feasible with commercially available cryocoolers. The results outline a clear path toward cost-effective, table-top sources for extreme-ultraviolet lithography, dynamic nuclear polarization, and fusion systems.

Panisset, Constant [Ecole Polytechnique Federale L↗

Advances in Nb 3 Sn superconducting radiofrequency cavities towards first practical accelerator applications

Abstract Nb 3 Sn is a promising next-generation material for superconducting radiofrequency cavities, with significant potential for both large scale and compact accelerator applications. However, so far, Nb 3 Sn cavities have been limited to continuous wave accelerating fields <18 MV m −1 . In this paper, new results are presented with significantly higher fields, as high as 24 MV m −1 in single cell cavities. Results are also presented from the first ever Nb 3 Sn-coated 1.3 GHz 9-cell cavity, a full-scale demonstration on the cavity type used in production for the European XFEL and LCLS-II. Results are presented together with heat dissipation curves to emphasize the potential for industrial accelerator applications using cryocooler-based cooling systems. The cavities studied have an atypical shiny visual appearance, and microscopy studies of witness samples reveal significantly reduced surface roughness and smaller film thickness compared to typical Nb 3 Sn films for superconducting cavities. Possible mechanisms for increased maximum field are discussed as well as implications for physics of RF superconductivity in the low coherence length regime. Outlook for continued development is presented.

43 PARTICLE ACCELERATORS↗

A turnkey gaseous helium-cooled superconducting CORC ® dc power cable with integrated current leads

Abstract High-temperature superconducting (HTS) direct current (dc) power cable systems, capable of delivering power exceeding 10 MW while being cooled with cryogenic helium gas, have been developed for applications on naval electric ships, electric aircraft and in data centers. Current injection from room temperature into the superconducting power cable causes by far the greatest heat load to the cryogenic system. Efficient current leads with integrated helium gas heat exchangers were developed to inject a current exceeding 1 kA from room temperature into a superconducting Conductor on Round Core (CORC ® ) power cable, without the need for liquid nitrogen pre-cooling. A 2 m long single-pole CORC ® power cable system that included current leads was cooled using a Stirling cryocooler with a closed-loop helium gas circulation system. The turnkey power cable system allowed cool down from room temperature to its operating temperature of 60 K–70 K within 5 h, after which continuous operation at 1.2 kA was demonstrated. The successful development and demonstration of a CORC ® power cable with current leads containing integrated helium gas heat exchangers enables widespread implementation of HTS MW-class, high current density superconducting dc power cables in many applications with constrained space that require a power dense solution.

Physics↗

A New Superconducting Undulator Cryostat for the APS Upgrade

The Advanced Photon Source (APS) is in the midst of a major facility upgrade including both a new electron storage ring (SR) and many new insertion devices ( IDs) providing x-ray photon beams to a new suite of experimental end stations. Included among the new IDs are four 4.8-meter superconducting undulator (SCU) cryostats, each containing two 1.8-meter planar undulator magnets operating at 4.2 K in either a phase shifted or canted configuration. We describe a new, compact cryocooler-based cryostat design which supports the magnets and associated subsystems and also fits the space constraints of the SR ID straight sections. The design is an evolution of earlier single-magnet 2-meter cryostats, retaining some subsystem commonality while incorporating lessons learned and several features unique to the challenge of supporting two independently operable undulator magnets in a single device.

Anliker, E.↗

Equidistant optimization of elliptical superconducting rf standing wave cavities

A record accelerating rate was achieved earlier in standing wave (SW) SRF cavities when their shape was optimized for a lower peak surface magnetic field sacrificing the peak surface electric field. In view of new materials with higher limiting magnetic fields, expected for SRF cavities, in the first line of the Nb 3 Sn, the approach to optimization of cavity shape should be revised. A method of equidistant optimization, offered earlier for traveling wave (TW) cavities is applied to SW cavities. It is shown here that without limitation by magnetic field, the maximal accelerating rate is defined not only by limitations of the electric field but to a significant degree by the cavity shape. For example, for a cavity with the aperture radius of $R$ $a$ = 35 mm, the minimal ratio of the peak surface electric field to the accelerating rate is about $E$ pk / $E$ acc = 1.54. So, with the maximal surface field experimentally achieved $E$ pk ~ 125 MV / m, the maximal achievable accelerating rate is about 80 MeV / m even if there are no restrictions by the magnetic field. Optimized cavity shapes with and without limitations by a magnetic field are presented. Another opportunity—optimization for a low magnetic field, is opening for the same material, Nb 3 Sn, with the purpose of having a high-quality factor and increased accelerating rate that can be used for industrial linacs with cryocooler-based cooling scheme.

43 PARTICLE ACCELERATORS↗

Towards a wavefront-preservation X-ray crystal monochromator for high-repetition-rate FELs

The wavefront preservation of coherent X-ray free-electron laser beams is pushing the requirement on the quality and performance of X-ray optics to an unprecedented level. The Strehl ratio can be used to quantify this requirement. In this paper, the criteria for thermal deformation of the X-ray optics are formulated, especially for crystal monochromators. To preserve the X-ray wavefront, the standard deviation of the height error should be sub-nm for mirrors and less than 25 pm for crystal monochromators. Cryocooled silicon crystals combined with two techniques can be used to achieve this level of performance for monochromator crystals: (1) using a focusing element to compensate the second-order component of the thermal deformation; (2) introducing a cooling pad between the cooling block and silicon crystal and optimizing the effective cooling temperature. Each of these techniques allows the thermal deformation in standard deviation of the height error to be reduced by an order of magnitude. As an example, for the LCLS-II-HE Dynamic X-ray Scattering instrument, the criteria on thermal deformation of a high-heat-load monochromator crystal can be achieved for a 100 W SASE FEL beam. Wavefront propagation simulations confirm that the reflected beam intensity profile is satisfactory on both the peak power density and focused beam size.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

Cryotrapping peroxide in the active site of human mitochondrial manganese superoxide dismutase crystals for neutron diffraction

Structurally identifying the enzymatic intermediates of redox proteins has been elusive due to difficulty in resolving the H atoms involved in catalysis and the susceptibility of ligand complexes to photoreduction from X-rays. Cryotrapping ligands for neutron protein crystallography combines two powerful tools that offer the advantage of directly identifying hydrogen positions in redox-enzyme intermediates without radiolytic perturbation of metal-containing active sites. However, translating cryogenic techniques from X-ray to neutron crystallography is not straightforward due to the large crystal volumes and long data-collection times. Here, methods have been developed to visualize the evasive peroxo complex of manganese superoxide dismutase (MnSOD) so that all atoms, including H atoms, could be visualized. The subsequent cryocooling and ligand-trapping methods resulted in neutron data collection to 2.30 Å resolution. The P 6 1 22 crystal form of MnSOD is challenging because it has some of the largest unit-cell dimensions ( a = b = 77.8, c = 236.8 Å) ever studied using high-resolution cryo-neutron crystallography. The resulting neutron diffraction data permitted the visualization of a dioxygen species bound to the MnSOD active-site metal that was indicative of successful cryotrapping.

59 BASIC BIOLOGICAL SCIENCES↗

Cryogenic Considerations for Superconducting Magnet System Design for the Material Plasma Exposure eXperiment (MPEX)

The Material Plasma Exposure eXperiment (MPEX) has been proposed as a facility to address plasma material interaction knowledge gaps to qualify and develop materials and technologies that surround plasma environments for future fusion reactors. Utilizing different radio-frequency (rf) heating technologies, MPEX is a linear plasma device that will generate fusion reactor–like plasmas with energies and particle fluxes at the target materials with electron temperatures of 1 to 15 eV, electron densities of 10 20 to 10 21 m -3 , and ion fluxes greater than 10 24 m -2 s -1 . Starting with the MPEX requirements with respect to magnetic fields between 0.1 and 2.5 T and warm bores of either 0.65 m or 1.56 m, conceptual designs for a superconducting magnet system have been developed that utilize multiple NbTi windings distributed across seven cryostats to accommodate rf heating, water cooling, and vacuum systems needed for MPEX. While the cryogenic and magnet technologies relative to the field and space requirements are mature, the integration of these technologies across multiple cryostats presents several technical and logistical challenges. An analysis of the preferred refrigeration approach, modular recondensing liquid helium cryocoolers, was performed. Utilizing a design margin of a factor of two, this approach is feasible within the current design requirements for MPEX with some considerations related to its implementation within the thermal shields and the magnet subsystem geometries.

Duckworth, Robert↗

A Preliminary Thermal Model of the LHe-based SCAPE Cryostat

The SCAPE (SuperConducting Arbitrarily Polarizing Emitter) undulator is under development at the Advanced Photon Source (APS). This new undulator requires a cryostat that will be designed based on expected heat loads. For instance, the expected heating of the beam chamber by electron beam is estimated to be at a level of 182 W – much higher than in planar SCUs. This and other challenges require careful thermal analysis of the LHe-based SCAPE cryostat. A detailed thermal model of the LHe-based SCAPE cryostat has been created in ANSYS. This paper presents calculated cooling capacity and temperatures of the SCAPE cryostat for the static and dynamic heat loads. Index Terms—SCAPE (SuperConducting Arbitrarily Polarizing Emitter), cryocooler, LHe, thermal isolation, thermal conductance.

Shiroyanagi, Y.↗

A PRELIMINARY CRYOGENIC PERFORMANCE TEST OF THE 4.8-M-LONG CRYOSTAT FOR SUPERCONDUCTING UNDULATORS

A 4.8-m-long cryostat has been developed to cool a pair of 1.9-m-long planar superconducting undulator magnets (SCUs). The final design and the thermal model of this cryocooler-cooled LHe-based cryostat have been completed. The cryostat is fabricated, and a preliminary cooldown test has been performed. This paper presents a comparison between measured and calculated thermal performance of the 4.8-m-long cryostat for the SCU.

Shiroyanagi, Y.↗

Cryogenic System Preliminary Design for a 0.5m-Long, Conduction-Cooled Nb3Sn Undulator Magnet Prototype

There are several NbTi superconducting undulator (SCU) magnets currently in operation at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The development on Nb3Sn-based superconducting undulator magnets at APS is underway due to the potential to further enhance the performance of the SCUs. Superconducting undulator magnets need to keep temperature gradients minimized in order to retain thermal and operating current margin. We have designed the thermal links for efficient heat conduction using 3D finite element analysis (FEA) simulation in COMSOL Multiphysics software, which was later used for the calculation of the temperature distribution across a 0.5 m long, conduction-cooled, Nb3Sn undulator magnet prototype that includes both conductive heat transfer and radiative heating components. We have modelled the evolution of the thermal properties of the magnet winding as well as other cold parts during cool-down from ambient temperature with the operation of a SHI RDK-415D cryocooler to examine the estimated time that is needed for the cooldown as well as the baseline temperature we could achieve. A key result was that a maximum coil delta T = 0.11 K along the designed thermal links and a temperature range of 3.42 K-3.53 K for the winding were predicted at steady state. A pair of G10 support rods for carrying the magnet as well as a pair of current leads made of metals were also designed and optimized for the testing system, targeting for an operation temperature of 4 K and a coil current of 950 A DC.

Zhang, Danlu↗