Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic tank insulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Composite, Cryogenic, Conformal, Common Bulkhead, Aerogel-Insulated Tank (CBAT) Materials and Processing Methodologies

A viewgraph presentation outlines the current status and future activities of the composite, cryogenic, conformal, common bulkhead, aerogel-insulated tank (CBAT). Each term (composite, cryogenic, conformal, etc.) is explained. The fabrication method for the CBAT is described, including challenges and their solutions. Near term and long term goals are discussed.

Kovach, Michael P.↗

An analytical study of reusable flight-weight cryogenic propellant tank designs

Thermostructural analyses of reusable flight-weight cryogenic tanks for a vertically launched space vehicle have been conducted. An analytical procedure was developed for sizing the tank structure, cryogenic insulation, and thermal protection system. Unstiffened, integrally-stiffened, and honeycomb core sandwich tank skins using aluminum or stainless steel materials were compared for their ability to meet design criteria at least weight. Cryogenic insulation systems were also evaluated, including closed-cell cryogenic foams and evacuated honeycomb core. The results indicate that a 400 F foam-insulated unstiffened-skin aluminum tank structure is the lightest structure for either LOX or LH2 tanks that meet the selected design criteria, but only two to four percent lighter than a stiffened aluminum tank.

Taylor, A. H.↗

Design and development of pressure and repressurization purge system for reusable space shuttle multilayer insulation system

The manufacturing tasks for the program included the fabrication and assembly of an epoxy fiberglass purge bag to encapsulate an insulated cryogenic propellant tank. Purge, repressurization and venting hardware were procured and installed on the purge bag assembly in preparation for performance testing. The fabrication and installation of the superfloc multilayer insulation (MLI) on the cryogenic tank was accomplished as part of a continuing program. An abstraction of the results of the MLI fabrication task is included to describe the complete fabrication requirements for a reusable cryogenic propellant space storage system.

Source record↗

Opacified fibrous thermal insulation

Lightweight, opacified, glass fiber batting for high temperature insulation in cryogenic tanks has lower apparent thermal conductivity than untreated insulations. Decrease results from impeding the transmission of radiant energy without increasing the solid conductance of the material.

Chambellan, R. E.↗

Insulation For Cryogenic-Liquid Tanks

Rigid foam and radiation shields prevent excessive heating in variety of environments. Report discusses design, development, and test of thermal-protection system for liquid-oxygen and liquid-hydrogen tanks of now discontinued Shuttle/Centaur G' project. System protects tank from excessive heat before and during launches, while in orbit around Earth, and during premature landings from aborted launches. Designed to withstand stresses of launch and emergency landing, acoustical loads, rapid changes in pressure, and impingement of rapidly flowing gas near vents of cargo bay in Space Shuttle. Primary requirements in design, system presents no hazard to Space Shuttle or its crew.

Knoll, Richard H.↗

MCNP Simulations of Measurement of Insulation Compaction in the Cryogenic Rocket Fuel Tanks at Kennedy Space Center by Fast/Thermal Neutron Techniques

MCNP simulations have been run to evaluate the feasibility of using a combination of fast and thermal neutrons as a nondestructive method to measure of the compaction of the perlite insulation in the liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC). Perlite is a feldspathic volcanic rock made up of the major elements Si, AI, Na, K and 0 along with some water. When heated it expands from four to twenty times its original volume which makes it very useful for thermal insulation. The cryogenic tanks at Kennedy Space Center are spherical with outer diameters of 69-70 feet and lined with a layer of expanded perlite with thicknesses on the order of 120 cm. There is evidence that some of the perlite has compacted over time since the tanks were built 1965, affecting the thermal properties and possibly also the structural integrity of the tanks. With commercially available portable neutron generators it is possible to produce simultaneously fluxes of neutrons in two energy ranges: fast (14 Me V) and thermal (25 me V). The two energy ranges produce complementary information. Fast neutrons produce gamma rays by inelastic scattering, which is sensitive to Fe and O. Thermal neutrons produce gamma rays by prompt gamma neutron activation (PGNA) and this is sensitive to Si, Al, Na, K and H. The compaction of the perlite can be measured by the change in gamma ray signal strength which is proportional to the atomic number densities of the constituent elements. The MCNP simulations were made to determine the magnitude of this change. The tank wall was approximated by a I-dimensional slab geometry with an 11/16" outer carbon steel wall, an inner stainless wall and 120 cm thick perlite zone. Runs were made for cases with expanded perlite, compacted perlite or with various void fractions. Runs were also made to simulate the effect of adding a moderator. Tallies were made for decay-time analysis from t=0 to 10 ms; total detected gamma-rays; detected gamma-rays from thermal neutron reactions d. detected gamma-rays from non-thermal neutron reactions and total detected gamma-rays as a function of depth into the annulus volume. These indicated a number of possible independent metrics of perlite compaction. For example the count rate for perlite elements increased from 3600 to 8500 cps for an increase in perlite density from 6 lbs/lcf to 16.5 lbs/cf. Thus the MCNP simulations have confirmed the feasibility of using neutron methods to map the compaction of perlite in the walls of the cryogenic tanks.

Livingston, R. A.↗

Measurement of Insulation Compaction in the Cryogenic Fuel Tanks at Kennedy Space Center by Fast/Thermal Neutron Techniques

The liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC) use expanded perlite as thermal insulation. Th ere is evidence that some of the perlite has compacted over time, com promising the thermal performance and possibly also structural integr ity of the tanks. Therefore an Non-destructive Testing (NDT) method for measuring the perlite density or void fraction is urgently needed. Methods based on neutrons are good candidates because they can readil y penetrate through the 1.75 cm outer steel shell and through the ent ire 120 cm thickness of the perlite zone. Neutrons interact with the nuclei of materials to produce characteristic gamma rays which are the n detected. The gamma ray signal strength is proportional to the atom ic number density. Consequently, if the perlite is compacted then the count rates in the individual peaks in the gamma ray spectrum will i ncrease. Perlite is a feldspathic volcanic rock made up of the major elements Si, AI, Na, K and 0 along with some water. With commercially available portable neutron generators it is possible to produce simul taneously fluxes of neutrons in two energy ranges: fast (14 MeV) and thermal (25 meV). Fast neutrons produce gamma rays by inelastic scatt ering which is sensitive to Fe and O. Thermal neutrons produce gamma rays by radiative capture in prompt gamma neutron activation (PGNA) and this is sensitive to Si, AI, Na, Kand H. Thus the two energy ranges produce complementary information. The R&D program has three phases: numerical simulations of neutron and gamma ray transport with MCNP s oftware, evaluation of the system in the laboratory on test articles and finally mapping of the perlite density in the cryogenic tanks at KSC. The preliminary MCNP calculations have shown that the fast/therma l neutron NDT method is capable of distinguishing between expanded an d compacted perlite with excellent statistics.

Livingston, R. A.↗

Effective thermal conductivity of insulation materials for cryogenic LH 2 storage tanks: A review

An accurate estimation of the effective thermal conductivity of various insulation materials is essential in the evaluation of heat leak and boil-off rate from liquid hydrogen storage tanks. In this work, we review the existing experimental data and various proposed correlations for predicting the effective conductivity of insulation systems consisting of powders, foams, fibrous materials, and multilayer systems. We also propose a first principles-based correlation that may be used to estimate the dependence of the effective conductivity as a function of temperature, interstitial gas composition, pressure, and structural properties of the material. We validate the proposed correlation using available experimental data for some common insulation materials. Further improvements and testing of the proposed correlation using laboratory scale data obtained using potential LH 2 tank insulation materials are also discussed.

08 HYDROGEN↗

Liquid Hydrogen and other Cryogenic Instrumentation Experience at NASA Glenn

NASA has learned extensive lessons on instrumentation of hydrogen systems during technology developments activities focused on the development of in-space cryogenic fluid management technologies. A subset of these lessons that are useful for aircraft and terrestrial applications using liquid hydrogen are presented to help disseminate the information learned. Discussion includes temperature, pressure, flow, and mass gauging options.

Liquid Hydrogen↗

Study of methane fuel for subsonic transport aircraft

The cost and performance were defined for commercial transport using liquid methane including its fuel system and the ground facility complex required for the processing and storage of methane. A cost and performance comparison was made with Jet A and hydrogen powered aircraft of the same payload and range capability. Extensive design work was done on cryogenic fuel tanks, insulation systems as well as the fuel system itself. Three candidate fuel tank locations were evaluated, i.e., fuselage tanks, wing tanks or external pylon tanks.

Carson, L. K.↗

Nondestructive Inspection Of Foam And Multilayer Insulations

Techniques and equipment enable nondestructive inspection of sprayed-on foam and multilayer reflecting thermal insulations on metallic substrates. Technology is applied in factories and laboratories; to inspect insulation on cryogenic tanks and pipes. Equipment includes probe head, several electronic modules that take measurements via electromagnetic and electrostatic sensors in probe head, small computer to store and process signals from modules, and printer.

Krause, Dennis R.↗

An advanced manned launch system concept

A two-stage fully reusable rocked powered concept is defined and analyzed in detail for the Advanced Manned Launch System missions. The concept elements include a Mach 3 staging unmanned glideback booster and a 149-ft long winged orbiter with an external payload canister with a 15-ft diameter and 30-ft long payload bay. The booster and orbiter main propulsion system is a lightweight derivative of the current Space Shuttle Main Engine. The primary mission is the Space Station Freedom logistics mission, 40,000-lb payload with two crew members and eight passengers. The structural design and material selection, the thermal protection system, the integral cryogenic tanks and insulation, the propulsion system, and the modular payload canister system are described. The ground and flight operations approach analysis, the manufacturing and certification plan, and the technology development requirements are also discussed.

Stone, H. W.↗

Reusable Cryogenic Tank VHM Using Fiber Optic Distributed Sensing Technology

The reusable oxygen and hydrogen tanks are key systems for both the X-33 (sub-scale, sub-orbital technology demonstrator) and the commercial Reusable Launch Vehicle (RLV). The backbone of the X-33 Reusable Cryogenic Tank Vehicle Health Management (VHM) system lies in the optical network of distributed strain temperature and hydrogen sensors. This network of fiber sensors will create a global strain and temperature map for monitoring the health of the tank structure, cryogenic insulation, and Thermal Protection System. Lockheed Martin (Sanders and LMMSS) and NASA Langley have developed this sensor technology for the X-33 and have addressed several technical issues such as fiber bonding and laser performance in this harsh environment.

Bodan-Sanders, Patricia↗