EFFECT OF NUCLEAR RADIATION ON MATERIALS AT CRYOGENIC TEMPERATURES.
Nuclear radiation effect on materials at cryogenic temperatures
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Nuclear radiation effect on materials at cryogenic temperatures
Thin aluminum foil filters have been evaluated at cryogenic temperatures. The results of the test program, including cold cycling and vibration testing, indicate that these filters are fully successful at cryogenic temperatures and can provide the high X-ray transmittance and high background rejection required for the blocking filters which are being developed for the X-Ray Spectrometer, one of the focal plane instruments on the Advanced X-Ray Astrophysics Facility.
Effect of nuclear radiation on materials at cryogenic temperatures
Mechanical properties of Hastelloy sheet alloy at cryogenic temperatures
Strain gauges for use at cryogenic temperatures
Strain sensitivity and resistance change determinations at cryogenic temperatures indicate that the armour d foil and michrome v strain gages are more suitable at low temperature
Development tests were conducted to evaluate the performance of 2 COPV designs at cryogenic temperatures. This allows for risk reductions for critical components for a Gaseous Helium (GHe) Pressurization Subsystem for an Advanced Propulsion System (APS) which is being proposed for NASA s Constellation project and future exploration missions. It is considered an advanced system since it uses Liquid Methane (LCH4) as the fuel and Liquid Oxygen (LO2) as the oxidizer for the propellant combination mixture. To avoid heating of the propellants to prevent boil-off, the GHe will be stored at subcooled temperatures equivalent to the LO2 temperature. Another advantage of storing GHe at cryogenic temperatures is that more mass of the pressurized GHe can be charged in to a vessel with a smaller volume, hence a smaller COPV, and this creates a significant weight savings versus gases at ambient temperatures. The major challenge of this test plan is to verify that a COPV can safely be used for spacecraft applications to store GHe at a Maximum Operating Pressure (MOP) of 4,500 psig at 140R to 160R (-320 F to -300 F). The COPVs for these tests were provided by ARDE , Inc. who developed a resin system to use at cryogenic conditions and has the capabilities to perform high pressure testing with LN2.
ColdADC is a low-noise 16-channel analog-to-digital converter ASIC designed for cold readout electronics of Liquid Argon Time Projection Chambers (LArTPCs) in the Deep Underground Neutrino Experiment (DUNE). ColdADC was specifically designed for operation at cryogenic temperatures (77 K–89 K). Cold electronics is considered to be an enabling technology for liquid argon detectors in neutrino experiments. The main function of the chip is to digitize signals from the 16-channel charge-sensitive amplifier designed at BNL (LArASIC) and send digitized signals to the data aggregator and serializer chip (COLDATA). ColdADC operates with a resolution of 12 bits and a sampling rate of 2 MS/s per channel. A complete characterization of prototype chips was conducted at cryogenic temperature, involving power consumption, noise and linearity performance. In the first DUNE Far-Detector module, 384000 data channels will be read out, corresponding to 24000 ColdADC chips. Therefore, systematic testing of ColdADC chips at cryogenic temperature is vital for the quality and reliability of DUNE Single-Phase modules. We have developed a Quality Control (QC) test stand that includes ColdADC evaluation and characterization at cryogenic temperature. The QC procedure was applied to a first batch of 33 chips, corresponding to 528 data channels. The obtained results meet all the required DUNE specifications for ColdADC. Moreover, the testing outcome allowed us to identify possibilities of performance optimization that are currently being addressed in the design of the next version of the chip. The Quality Control procedure is proved to be successful and will be a reference design for future large-batch production testing of final ColdADC ASICs.
CrCoNi-based high-entropy alloys have demonstrated outstanding mechanical properties, particularly at cryogenic temperatures. Here we investigate the fatigue-crack propagation properties of the equiatomic, single-phase, face-centered cubic, medium-entropy alloy (MEA), CrCoNi, that displays exceptional strength, ductility and toughness, all of which are enhanced at cryogenic temperatures. Fatigue-crack growth is examined, at a load ratio of 0.1 over a wide range of growth rates, from ~10 –11 to >10 –7 m/cycle, at room (293 K) and cryogenic (198 K, 77 K) temperatures for two grain sizes (~7 and 68 µm), with emphasis on near-threshold behavior. We find that the ΔK th fatigue thresholds are increased with decreasing temperature and increasing grain size: from 5.7 MPa√m at 293 K to 8 MPa√m at 77 K in the fine-grained alloy, and from 9.4 MPa√m at 293 K to 13.7 MPa√m at 77 K in the coarse-grained alloy. Mechanistically, transgranular cracking at 293 K transitions to a mixture of intergranular and transgranular at cryogenic temperatures, where the increased propensity of nano-twins appears to inhibit growth rates by deflecting the crack path. However, the main factor affecting near-threshold behavior is roughness-induced crack closure from interference between the crack flanks, which is enhanced by the rougher fracture surfaces at low temperatures, particularly in the coarser-grained microstructure. Here, fatigue-crack propagation behavior in CrCoNi is comparable to nickel-based superalloys but is superior to that of the high-entropy CrMnFeCoNi (Cantor) alloy and many high-strength steels, making the CrCoNi alloy an excellent candidate material for safety-critical applications, particularly involving low temperatures.
Two-axis pickoff for cryogenic gyros uses solid-state light sources and sensors. This compact system operates efficiently at cryogenic temperatures.
Gallium arsenide cryogenic temperature sensor development
Thermal expansion of polymers at cryogenic temperatures
To calibrate transducers immersed in cryogenic environment, sealed reciprocating bellows generates sinusoidal dynamic pressure. Transducer manifold assembly and bellows immersed in cryogenic environment to minimize gradients in controllable cryogenic temperature.
The operation of power electronic systems at cryogenic temperatures is anticipated in many future space missions such as planetary exploration and deep space probes. In addition to surviving the space hostile environments, electronics capable of low temperature operation would contribute to improving circuit performance, increasing system efficiency, and reducing development and launch costs. DC/DC converters are widely used in space power systems in the areas of power management, conditioning, and control. As part of the on-going Low Temperature Electronics Program at NASA, several commercial-off-the-shelf (COTS) DC/DC converters, with specifications that might fit the requirements of specific future space missions have been selected for investigation at cryogenic temperatures. The converters have been characterized in terms of their performance as a function of temperature in the range of 20 C to - 180 C. These converters ranged in electrical power from 8 W to 13 W, input voltage from 9 V to 72 V and an output voltage of 3.3 V. The experimental set-up and procedures along with the results obtained on the converters' steady state and dynamic characteristics are presented and discussed.
Mechanical properties of type 202 stainless steel at cryogenic temperatures
For cryogenically-cooled infrared instruments and telescopes employed in space, reliable and predictable motor operations at 4 K in vacuum are in most cases necessary. For the Shuttle Infrared Telescope Facility (SIRTF), stepper motors may be employed in a number of applications. A test facility was designed and built for measuring stepper motor positional repeatability, in vacuum, over a temperature range from ambient to liquid helium temperature. Tests regarding positional repeatability were conducted at different motor speeds, directions of motor rotation, step sizes, and power conditions. In addition, tests were performed with respect to the ability of the motor to remain in a position with no power applied to the motor.
A sharp leading edge delta-wing model was tested through an angle-of-attack range at Mach numbers of 0.75, 0.80, and 0.85 at both ambient and cryogenic temperatures in the Langley 1/3-meter transonic cryogenic tunnel. Total pressure was varied with total temperature in order to hold test Reynolds number constant at a given Mach number. Agreement between the aerodynamic data obtained at ambient and cryogenic temperatures indicates that flows with leading-edge vortex effects are duplicated properly at cryogenic temperatures. The test results demonstrate that accurate aerodynamic data can be obtained by using conventional force-testing techniques if suitable measures are taken to minimize temperature gradients across the balance and to keep the balance at ambient (warm) temperatures during cryogenic operation of the tunnel.
Results of an engineering study to measure changes in structural damping properties of two cryogenic wind tunnel model systems and two metallic test specimens at cryogenic temperatures are presented. Data are presented which indicate overall, a trend toward reduced structural damping at cryogenic temperatures (-250 degrees F) when compared with room temperature damping properties. The study was focused on structures and materials used for model systems tested in the National Transonic Facility (NTF). The study suggests that the significant reductions in damping at extremely cold temperatures are most likely associated with changes in mechanical joint compliance damping rather than changes in material (solid) damping.