At least 55 records · Page 3

Electricity Rate Designs for Large Loads: Evolving Practices and Opportunities

Electricity demand from large load customers such as data centers is projected to grow significantly in the near term. While data centers play an important role in advancing technology innovation and economic growth in the United States, data center energy needs present challenges and opportunities for electricity supply and infrastructure. This technical brief serves as a foundation for the discussion of issues and sharing of perspectives among utilities, regulators, large load customers, and other stakeholders. As utilities and regulators explore rate structures to address growing data center electricity demand, several issues have emerged: -Fair allocation of electricity system costs to large-load customers without unfair shifting of costs to other customers -Appropriate mitigation of the financial risks associated with stranded assets from underutilized utility system investments -Mitigation of operational and resource adequacy risks if electricity demand exceeds supply -Appropriate risk-sharing in commercializing newer electricity technologies such as advanced geothermal, small modular reactors, and long duration energy storage -Accommodating the diverse needs of large-load customers, such as having the option to match electricity consumption with output from carbon-free resources or using onsite generation to provide system capacity The technical brief also identifies key design elements that aim to address these issues and uses leading examples from pending and approved rate structures, agreements, and special contracts to ground the elements in practice.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A dataset of recorded electricity outages by United States county 2014–2022

In this Data Descriptor, we present county-level electricity outage estimates at 15-minute intervals from 2014 to 2022. By 2022 92% of customers in the 50 US States, Washington DC, and Puerto Rico are represented. These data have been produced by the Environment for Analysis of Geo-Located Energy Information (EAGLE-I TM ), a geographic information system and data visualization platform created at Oak Ridge National Laboratory to map the population experiencing electricity outages every 15 minutes at the county level. Although these data do not cover every US customer, they represent the most comprehensive outage information ever compiled for the United States. The rate of coverage increases through time between 2014 and 2022. We present a quantitative Data Quality Index for these data for the years 2018–2022 to demonstrate temporal changes in customer coverage rates by FEMA region and indicators of data collection gaps or other errors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Influence of Molybdenum on Rapid Solidification Microstructure and Microsegregation in Primary Ferrite Solidified Stainless Steel

Due to the widespread use and familiarity of austenitic stainless steels in many industries these alloys are often the first materials used when adapting new processing techniques. The rapid cooling and solidification rates that occur during fusion based additive manufacturing processes like powder bed fusion cause a fundamental shift in the solidification behavior of the material. While the effects that Cr and Ni have on the microstructure have been fairly well documented across a range of solidification conditions, the impact of alloying elements like Mo are not as well understood at rapid solidification rates. For this study, four custom stainless steel alloy feedstocks were made with targeted modification of the Cr and Mo concentrations to maintain a constant Cr/Ni eq ratio of ~1.7. Two-piston splat quenching was used to produce rapidly solidified samples and the solidification mode, phase, and cell size were investigated. Solidification rates were estimated to be between 0.4 and 1.5m/s. A comparison of the microsegregation and partitioning behavior of Cr, Ni and Mo in ferrite solidified material was also performed for the different alloy compositions. Variations of the Mo concentration between each feedstock showed no measurable influence on the solidification/cooling rates, solidification morphology, or the partitioning of Mo. Furthermore, higher concentrations of Mo were found to significantly increase the amount of ferrite phase in the microstructure by suppressing the ferrite to austenite massive transformation.

36 MATERIALS SCIENCE↗

Potential Impacts of Dynamic Electricity Pricing in California: Load Shape and Customer Bill Impacts Under Elastic Customer Response

The increasing penetration of renewable energy in California has intensified grid management challenges, exemplified by the “duck curve” and the resulting need for steep ramping and curtailment of renewables. To address these issues, dynamic electricity tariffs that vary in near-real time are being considered to incentivize customers to shift demand and support the grid. This study extends previous work on the bill impacts of such tariffs in the absence of load response by quantifying the system-level and customer impacts of load response based on customer price elasticity. Customer-level load response modeling was conducted using meter data from 411,000 customers across residential, commercial, and industrial sectors. Customer demand elasticity was estimated using literature-based values, with scenarios ranging from low to high elasticity, including an automation-enhanced scenario. Results indicate that universal adoption of, and response to, dynamic tariffs can significantly reduce peak net load (by 15%) and maximum ramping requirements (by 20%) with moderate elasticity, delivering demand response resources comparable to or exceeding current programs at all elasticity levels. Bill analysis shows that, when responding elastically to dynamic prices, most non-PV customers experience modest savings, while PV customers may see higher effective rates due to lower compensation for exports during low-price periods. Emissions analysis reveals a reduction in per-kWh emissions system-wide, with a total absolute load increase of 2% accompanied by a negligible absolute emissions increase. The study concludes that while dynamic tariffs offer substantial grid benefits, customer bill savings under modeled response behaviors may be too modest to drive widespread adoption without additional incentives or enabling technologies. Future research should model flexible loads and advanced control technologies with greater fidelity to better represent the potential opportunities of dynamic tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Microbial Cell Technology: A high-throughput platform to optimize biocatalysts

Los Alamos National Laboratory developed an ultra-high-throughput screening platform to engineer custom biocatalysts that enhance the rate of chemical reactions critical in pharmaceuticals, renewable energy, and environmental cleanup. Current methods to find biocatalysts are slow. This platform scans genetic variations to optimize a single enzyme or microbial cell to generate a product efficiently. It selects rare mutations needed for biocatalyst optimization orders of magnitude faster than current screening methods. A custom sensor reporter gene circuit causes cells to fluoresce when they are making the target product. When coupled to flow cytometry, a million biocatalyst variants can be screened in hours.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Disaggregating Future Retail Electricity Rate Growth [Slides]

Recent Berkeley Lab research found that modest retail rate increases over the past 10 years were mostly driven by large increases in capital expenditures (CapEx) that were offset in part by substantial wholesale price reductions. Decision-makers are increasingly concerned about the potential future rate impacts of a number of policies and industry trends that support rapid decarbonization, electrification, and grid modernization. Using historical FERC Form 1 data and the existing literature on policies and industry trends that are likely to affect utility-incurred costs and retail sales, Berkeley Lab researchers developed ranges of forecasted growth rates for cost-related rate drivers (i.e., fuel and purchased power; transmission, distribution, generation, and other categories of both non-fuel operations & maintenance and CapEx) and non-cost related rate drivers (i.e., retail sales, peak demand, and customers). These were then used as inputs to a pro-forma utility financial model (FINDER) that estimated the growth in retail electric rates between 2020 and 2030 for a prototypical vertically-integrated investor-owned utility in the United States. The analysis produced the following results: 1. Assuming average growth rates in all rate drivers, future retail rate growth is driven by sizable increases in all CapEx costs, where fuel and purchased power costs are replaced by generation CapEx as the largest rate component between 2020 and 2030. 2. Growth in sales/peak demand/customers, generation CapEx costs, and fuel and purchased power (FPP) costs, in isolation, produce the most uncertainty in rate growth. Specifically, a 1% increase in the compound annual growth rate (CAGR) of retail sales, coincident peak demand (CP), and customers (Sales-CP-Cust) results in a 0.88-0.93% decrease in the CAGR of rates, in isolation. However, a 1% increase in the CAGR of generation CapEx budgets results in a 0.07-0.14% increase in the CAGR of rates, while a 1% increase in the CAGR of FPP costs causes a 0.10-0.14% increase in the CAGR of rates, all else being equal. 3. Taking into account the correlation and variability of the growth in all rate drivers jointly, generation CapEx is expected to be both the largest and most uncertain rate component by 2030 (20-25% share of the retail rate). Transmission and distribution CapEx, along with fuel and purchased power costs are each expected to comprise between 12% and 17% of retail rates.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Decision Support Tool for Distributed Solar and Storage Investments: A Case Study in Austin, TX

This study builds a decision support tool to evaluate when it is a good economic decision (least cost with minimum discomfort) for the residential customer to invest in distributed energy resources (DERs) based on different electricity rate structures, DER ownership frameworks, and DER rebates offered by electric utilities. Here, the tool is demonstrated using empirical electricity consumption data from Pecan Street Inc. (a non-profit entity based on Austin, Texas), residential rates from Austin Energy (the municipal electric utility in Austin, Texas), DER ownership costs from various nationwide pilot programs, and incentives offered by electric utilities in the United States. Results show that for constant electricity rates, the overall expenditure is least when the customer owns solar panels without storage, while for time-varying pricing structures, the least expensive scenario is one where the customer does not own any DERs. As the capital costs for DERs decline, utilities incentivize customer ownership of DERs, and more residential customers face the decision of whether to invest in DERs, this study aims to be a key tool in aiding that decision-making process.

14 SOLAR ENERGY↗

Computational capacity in hydrodynamic real-time hybrid simulation applied to simulate the dynamic response of floating offshore wind turbines

Real-time hybrid simulation (RTHS) mitigates similitude distortions in model-scale tests of floating offshore wind turbines (FOWTs) by coupling physical experiments with numerical models in real time. The coupling requires faster-than-real-time numerical computations to satisfy temporal similitude with the physical experiment, presenting a bottleneck for using more complex numerical models in RTHS. This paper presents a hydrodynamic-RTHS (hydro-RTHS) framework for FOWTs that simulates the hydrodynamics physically and the aerodynamics numerically with sensor feedback from the physical testing. The framework adapts the three-loop hardware architecture to leverage greater computational resources and mitigate strict temporal requirements, enabling more computationally demanding numerical analyses in hydro-RTHS. The three-loop hardware architecture integrates multiple machines, each dedicated to either numerical analysis or RTHS controls, with a rate-transition algorithm to synchronize the tasks executed across the different machine processors. Virtual and physical tests verified and validated the hydro-RTHS framework, respectively. The ”virtual” tests, which approximates the physical domain numerically, verified the RTHS framework with respect to a numerical full-scale complete FOWT model simulated in the open-source software, OpenFAST. The virtual tests were able to maintain comparable control signals while enabling greater computational resources for the numerical calculations. Real-world physical tests demonstrated that the hydro-RTHS framework computes aerodynamic forces similar to the complete OpenFAST model, validating the hydro-RTHS framework using the three-loop hardware architecture. Findings show that the hydro-RTHS framework with the three-loop hardware architecture is computationally efficient, with reserve capacity to simulate more complex problems due to the customized software, hardware, and rate-transition algorithm.

17 WIND ENERGY↗

Design trade-offs for residential retail tariffs and virtual power plants

Retail rate design and virtual power plants (VPPs) have the potential to shift customer electricity demand and provide economic benefits to utility customers. As the adoption of distributed energy resources (DERs) and flexible loads increases, retail tariff and program design can impact Bonbright's rate design principles including affordability, fairness, and economic efficiency. We model the effects of residential retail rates and VPP programs on power system costs in Massachusetts under a potential future system with high renewable energy and DER adoption. We model interactions among retail rate design, demand flexibility, and utility costs and identify trade-offs across different rate designs and VPP programs. We estimate that time-of-use (TOU) rates and VPP programs designed to avoid critical peak rates can lower overall system costs by 3.5 %-4.8 %. These lower costs translate to lower electricity bills for 62 %-91 % of customers, depending on the scenario. Although TOU rates with a critical peak VPP program can benefit all customer segments and are economically efficient, a VPP program with flat rates leads to the lowest overall bills for customers. We find that customers with loads that align with peak demand and who participate in critical peak VPP programs can underpay for their contribution to utility costs and shift costs to other customers. While our assumptions about mandatory TOU and/or critical peak pricing likely impact the magnitude of the results, the results highlight the trade-offs of these tariffs and programs and the importance of tariff and program design as demand becomes more flexible and responsive.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Building efficiency, electrification, and distributed solar PV bill savings under time-based retail rate designs

Building energy technologies and distributed generation, including energy efficiency (EE), distributed solar PV (DPV), and building electrification, are critical to meeting decarbonization goals. Rate design may play an important role in determining the customer economics of adopting these technologies, but it is unclear whether – and to what extent – current rate design trends support or impede progress toward these goals. In this study, we answer these questions by quantifying the range of residential customer bill impacts of EE, DPV, and building electrification investments under current and emerging time-based retail electricity rate designs (i.e., time-of-use, event-based pricing, coincident demand charges, and real time pricing). We also compare these customer bill savings to power system and societal benefits and assess how well the investments are compensated relative to the societal value they provide.

14 SOLAR ENERGY↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

Design of a new charge exchange recombination spectroscopy diagnostic for impurity transport experiments at Wendelstein 7-X

In this study, we present the design of a new charge exchange recombination spectroscopy (CXRS) system for Wendelstein 7-X (W7-X), which aims at measuring line radiation from highly ionized iron impurities after laser blow off injections over transport timescales. New fiber bundles with a core diameter of 600 µm have been added to one of the existing optical systems at W7-X used for CXRS. The fibers direct collected light to five newly developed single channel high frame rate F/2.8 spectrometers. The new custom-made spectrometers are built using entirely off-the-shelf and 3D printed components, and employ a round-to-linear fiber bundle, instead of an entrance slit, to maximize light throughput. The detector is an ultra-low readout noise EM-CCD camera capable of frame rates of up to 10 000 fps for about 500 consecutive frames when operated using a single readout channel. Such high frame rates will enable the study of inward convection of injected impurities. An initial sensitivity study is performed using a newly developed Markov chain Monte Carlo approach based on the pySTRAHL impurity transport code. This study indicates that, with the addition of the new CX diagnostic, impurity convection velocities can be inferred.

Instruments & Instrumentation↗

Field Demonstration of Residential DER Service-Oriented Load Participation

Amidst a concerning surge in power consumption during peak hours, coupled with heightened power grid instability, and driven by a growing demand for electricity, aggregations of Distributed Energy Resource are becoming a viable means for providing essential reliability services.Electric utility companies have proactively implemented Demand Response programs for decades. These programs employ Direct Load Control methods to enhance power grid stability, achieved by controlling customers’ Distributed Energy Resource during peak hours to reduce power consumption. However, a notable drawback of Direct Load Control has been high unenrollment rates of DR program participants due to customer discomfort.Therefore, the underlying issue of over-consumption persists. To address these concerns, this paper introduces a Service-Oriented Load Participation approach to providing grid services such as Demand Response. Leveraging a Service-Oriented Architecture, this method offers the advantage of efficient service management and provisioning within the system. The SOLP approach not only aims to reduce power consumption but also to maintain customer satisfaction by ensuring a comfortable grid service experience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Second Target Station Target Removal Dose Rates

The Second Target Station (STS) project at Oak Ridge National Laboratory’s spallation neutron source is a crucial initiative for maintaining U.S. leadership in neutron sciences. The STS aims to create the world’s brightest pulsed cold neutron source, enabling cutting-edge research across various scientific disciplines. To ensure safe and efficient maintenance operations, understanding the effects of shutdown dose rates from activated components within the STS target systems is essential. This study establishes a computational framework for calculating decay gamma sources and subsequent shutdown dose rates utilizing advanced methods to account for all activation channels, including high-energy interactions down to thermal neutron capture. This study describes a novel integration of multiple tools and provides an effective means of analyzing activation and shutdown dose rates at spallation neutron facilities. A custom-developed script automates the decay gamma source generation process, ensuring proper sampling during the variance reduction phase, which is critical for accurate predictions of shutdown dose rates.

Transmutation↗

Simulating Electron Impact Ionization using a General Particle Tracer (GPT) Custom Element

A new C++ custom element has been developed with the framework of General Particle Tracer (GPT) to simulate electron impact ionization of residual gas molecules. The custom element uses Monte-Carlo routines to determine both the ion production rate and the secondary electron kinetic energy based on user-defined gas densities and theoretical values for the ionization cross section and the secondary electron differential cross section. It then uses relativistic kinematics to track the secondary electron, the scattered electron, and the newly formed ion after ionization. The ion production rate and the secondary electron energy distribution determined by the custom element have been benchmarked against theoretical calculations and against simulations made using the simulation package IBSimu. While the custom element was originally built for particle accelerator simulations, it is readily extensible to other applications. The custom element will be described in detail and examples of applications at the Thomas Jefferson National Accelerator Facility will be presented for ion production in a DC high voltage photo-gun.

Yoskowitz, J. T.↗

Deliberate Design: Creating Electricity Rates with Purpose

Today’s electricity rates often are legacy designs that do not reflect the dynamics of an evolving power grid or align with current policy objectives. Four steps will assist utilities, regulators, and industry stakeholders in modernizing outdated electricity rate designs. 1. Understand the context for rate design change: The power system is changing at a pace that the industry has not experienced for decades. It is essential to understand the implications of these changes so rates can evolve to remain consistent with changes to the underlying cost profile, customer preferences, and power system requirements. 2. Establish ratemaking objectives: Rates can do more than recover utility costs. They can be a tool for promoting desired outcomes such as improved energy affordability, flexible and efficient electricity consumption, or promoting technology adoption. First, these objectives must be clearly defined and prioritized. 3. Account for tradeoffs when designing new rates: Rate design is the art of balancing tradeoffs. It is essential to understand these tradeoffs when designing new rates, particularly if the rates are being used as a tool for accomplishing policy objectives that extend beyond the basic goal of cost reflectivity. 4. Transition to the new rates with a plan: The move to well-designed rates requires a transition plan. This will ensure that rate design changes do not happen in isolation and are consistent with a long-term, holistic vision. The report, published as an interactive web tool for which the content can be separately downloaded as a standalone document, is intended to allow state energy regulators, utility rates staff, and other industry stakeholders with an interest in rate design to selectively “drill down” on content that is relevant to their interests and situation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Community Solar Consolidated Billing: An Exploration of Implementation and Alternatives [Slides]

This presentation is an abridged version of the report it is based on that presents an analysis of the considerations, costs, and benefits surrounding the implementation of utility consolidated billing in community solar programs while also exploring alternatives to achieve similar benefits in its absence. Consolidated billing simplifies the billing process for customers by combining all charges and credits associated with electricity service and community solar subscriptions into a single bill. The potential benefits of consolidated billing implementation include increased transparency, improved customer experience, and ultimately increased retention rates and decreased subscriber acquisition costs. Currently, community solar subscribers often receive two separate bills - one from the utility and one from a third-party community solar provider - potentially causing confusion. Consolidated billing seeks to resolve this by offering a unified bill, which, while beneficial to numerous stakeholders, presents administrative, technical, and financial hurdles that utilities and program administrators must address.

14 SOLAR ENERGY↗

Community Solar Consolidated Billing: An Exploration of Implementation and Alternatives

The report presents an analysis of the considerations, costs, and benefits surrounding the implementation of utility consolidated billing in community solar programs while also exploring alternatives to achieve similar benefits in its absence. Consolidated billing simplifies the billing process for customers by combining all charges and credits associated with electricity service and community solar subscriptions into a single bill. The potential benefits of consolidated billing implementation include increased transparency, improved customer experience, and ultimately increased retention rates and decreased subscriber acquisition costs. Currently, community solar subscribers often receive two separate bills - one from the utility and one from a third-party community solar provider - potentially causing confusion. Consolidated billing seeks to resolve this by offering a unified bill, which, while beneficial to numerous stakeholders, presents administrative, technical, and financial hurdles that utilities and program administrators must address.

14 SOLAR ENERGY↗