An Integrated MEMS Sensor Cluster System for Aerospace Applications

Efforts to reduce viscous drag on airfoils could results in a considerable saving for the operation of flight vehicles including those of space transportation. This reduction of viscous drag effort requires measurement and active control of boundary layer flow property on an airfoil. Measurement of viscous drag of the boundary layer flow over an airfoil with minimal flow disturbance is achievable with newly developed MEMS sensor clusters. These sensor clusters provide information that can be used to actively control actuators to obtain desired flow properties or design a vehicle to satisfy particular boundary layer flow criteria. A series of MEMS sensor clusters has been developed with a data acquisition and control module for local measurements of shear stress, pressure, and temperature on an airfoil. The sensor cluster consists of two shear stress sensors, two pressure sensors, and two temperature sensors on a surface area of 1.24 mm x 1.86 mm. Each sensor is 300 microns square and is placed on a flexible polyimide sheet. The shear stress sensor is a polysilicon hot-film resistor, which is insulated by a vacuum cavity of 200 x 200 x 2 microns. The pressure sensors are silicon piezoresistive type, and the temperature sensors are also hot film polysilicon resistors. The total size of the cluster including sensors and electrical leads is 1 Omm x 1 Omm x 0.1 mm. A typical sensitivity of shear stress sensor is 150 mV/Pascal, the pressure sensors are an absolute type with a measurement range from 9 to 36 psia with 0.8mV/V/psi sensitivity, and the temperature sensors have a measurement resolution of 0.1 degree C. The sensor clusters are interfaced to a data acquisition and control module that consists of two custom ASICs (Application Specific Integrated Circuits) and a micro-controller. The data acquisition and control module transfers data to a host PC that configures and controls a total of three sensor clusters. Functionality of the entire system has been tested in the laboratory, and preliminary test results are presented.

Kahng, Seun↗

Heavy Ion Radiation Effects Studies With Ion Photon Emission Microscopy

The development of a new radiation effects microscopy (REM) technique is crucial as emerging semiconductor technologies demonstrate smaller feature sizes and thicker back end of line (BEOL) layers. To penetrate these materials and still deposit sufficient energy into the device to induce single event effects, high energy heavy ions are required. Ion photon emission microscopy (IPEM) is a technique that utilizes coincident photons, which are emitted from the location of each ion impact to map out regions of radiation sensitivity in integrated circuits and devices, circumventing the obstacle of focusing high-energy heavy ions. Several versions of the IPEM have been developed and implemented at Sandia National Laboratories (SNL). One such instrument has been utilized on the microbeam line of the 6 MV tandem accelerator at SNL. Another IPEM was designed for ex-vacu use at the 88'' cyclotron at Lawrence Berkeley National Laboratory (LBNL). Extensive engineering is involved in the development of these IPEM systems, including resolving issues with electronics, event timing, optics, phosphor selection, and mechanics. The various versions of the IPEM and the obstacles, as well as benefits associated with each will be presented. In addition, the current stage of IPEM development as a user instrument will be discussed in the context of recent results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radially scanning magnetic probes to study local helicity injection dynamics

Two new magnetic probes have been deployed on the Pegasus spherical tokamak to study the dynamics of local helicity injection non-solenoidal plasma start-up and current drive. The magnetic radial array probe consists of 15 pickup coils (~5 × 8 mm each) that measure B z (R) over a 15 cm linear extent. The coils consist of traces embedded in a printed circuit board. Three coil designs are utilized to balance frequency response and coil sensitivity. Helmholtz coil measurements are used to measure coil and full assembly bandwidths (~2 MHz and ~200 kHz, respectively) and sensitivities (0.18/0.35/0.96 mV T -1 s). The magnetic radial scanning probe is an array of Hall effect sensors that measure field strength ( |B| 177 mT) and direction at 8 spatial points (ΔR = 1.5 cm), supporting the studies of equilibrium field structure and low-frequency (≤5 kHz) current dynamics. It uses commercial surface-mount Hall effect sensors with chip-integrated amplifiers and compensators that are mounted in a 3-D printed frame. Helmholtz coil measurements indicate negligible cross-field gain nonlinearity and provide absolute calibration of the diagnostic. Both probes are constructed as an electrostatically shielded insertable air-side assembly that mounts within a radially translatable ultrahigh vacuum assembly from an existing probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Binary selectable detector holdoff circuit: Design, testing, and application

A very high speed switching circuit, part of a laser radar data acquisition system, has been designed and tested. The primary function of this circuit was to provide computer controlled switching of photodiode detector preamplifier power supply voltages, typically less than plus or minus 20 volts, in approximately 10 nanoseconds. Thus, in actual use, detector and/or detector preamplifier damage can be avoided as a result of sudden extremely large values of backscattered radiation being detected, such as might be due to short range, very thin atmospheric dust layers. Switching of the power supply voltages was chosen over direct switching the photodiode detector input to the preamplifier, based on system noise considerations. Also, the circuit provides a synchronized trigger pulse output for triggering devices such as the Biomation Model 8100 100 MHz analog to digital converter.

Kadrmas, K. A.↗

FPGA remote update for nuclear environments

The Instituto de Plasmas e Fusao Nuclear (IPFN) has developed dedicated re-configurable modules based on field programmable gate array (FPGA) devices for several nuclear fusion machines worldwide. Moreover, new Advanced Telecommunication Computing Architecture (ATCA) based modules developed by IPFN are already included in the ITER catalogue. One of the requirements for re-configurable modules operating in future nuclear environments including ITER is the remote update capability. Accordingly, this work presents an alternative method for FPGA remote programing to be implemented in new ATCA based re-configurable modules. FPGAs are volatile devices and their programming code is usually stored in dedicated flash memories for properly configuration during module power-on. The presented method is capable to store new FPGA codes in Serial Peripheral Interface (SPI) flash memories using the PCIexpress (PCIe) network established on the ATCA back-plane, linking data acquisition endpoints and the data switch blades. The method is based on the Xilinx Quick Boot application note, adapted to PCIe protocol and ATCA based modules. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Environmental Radiation Monitoring System

A new precision low-level environmental radiation monitoring system has been developed and tested at Jefferson Lab. This system provides environmental radiation measurements with accuracy and stability of the order of 1 nGy/h in an hour, roughly corresponding to approximately 1% of the natural cosmic background at the sea level. Advanced electronic front-end has been designed and produced for use with the industry-standard High Pressure Ionization Chamber detector hardware. A new highly sensitive readout electronic circuit was designed to measure charge from the virtually suspended ionization chamber ion collecting electrode. New signal processing technique and dedicated data acquisition were tested together with the new readout. The designed system enabled data collection in a remote Linux-operated computer workstation, which was connected to the detectors using a standard telephone cable line. The data acquisition system algorithm is built around the continuously running 24-bit resolution 192 kHz data sampling analog to digital convertor. The major features of the design include: extremely low leakage current in the input circuit, true charge integrating mode operation, and relatively fast response to the intermediate radiation change. These features allow operating of the device as an environmental radiation monitor, at the perimeters of the radiation-generating installations in densely populated areas, like in other monitoring and security applications requiring high precision and long-term stability. Initial system evaluation results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs) at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring, Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases, distribution system state estimation (DSSE) and fault identification are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1 feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system↗

Device for Detection of Explosives, Nuclear and Other Hazardous Materials in Luggage and Cargo Containers

Device for detection of explosives, radioactive and heavily shielded nuclear materials in luggage and cargo containers based on Nanosecond Neutron Analysis/Associated Particles Technique (NNA/APT) is under construction. Detection module consists of a small neutron generator with built-in position-sensitive detector of associated alpha-particles, and several scintillator-based gamma-ray detectors. Explosives and other hazardous chemicals are detected by analyzing secondary high-energy gamma-rays from reactions of fast neutrons with materials inside a container. The same gamma-ray detectors are used to detect unshielded radioactive and nuclear materials. An array of several neutron detectors is used to detect fast neutrons from induced fission of nuclear materials. Coincidence and timing analysis allows one to discriminate between fission neutrons and scattered probing neutrons. Mathematical modeling by MCNP5 and MCNP-PoliMi codes was used to estimate the sensitivity of the device and its optimal configuration. Comparison of the features of three gamma detector types--based on BGO, NaI and LaBr{sub 3} crystals is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test facility for fission chamber assemblies - 239

The Institution -Project Center ITER- with participation of the National Research Nuclear University MEPhI are developing the neutron diagnostics -Divertor Neutron Flux Monitor- (DNFM) for the International Thermonuclear Experimental Reactor (ITER). This diagnostics shall ensure measurement of the total neutron yield and ITER fusion power. Assemblies of fission chambers (FC) with different fissile materials and sensitivities are planned to be used for the neutron flux measurement. Study of fission chambers characteristics and acceptance testing of the diagnostic system will be carried out at the testing facility of the neutronic laboratory of the 'TRINITI' Institute. The facility includes: compact powerful neutron generator with the power, control and monitoring system; remote handling system for FCs positioning and movement; novel three channels data acquisition and processing system. Each acquisition channel contains some measuring circuits with signal processing. This set of circuits provides neutron flux measurement in the range of at least 10 decades for each single FC. Data acquisition and processing system features are: signal digitizing with sample rate up to 125 MHz; real time data processing with computation and data update cycle from 0.1 ms. This paper examines the structure, composition and specification of the test facility. Application software, hardware solutions and the results of fission chambers prototypes tests are discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA Tech Briefs, September 2012

Topics covered include: Beat-to-Beat Blood Pressure Monitor; Measurement Techniques for Clock Jitter; Lightweight, Miniature Inertial Measurement System; Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts; Fuel Cell/Electrochemical Cell Voltage Monitor; Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor; Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks; Antenna Calibration and Measurement Equipment; Glass Solder Approach for Robust, Low-Loss, Fiber-to-Waveguide Coupling; Lightweight Metal Matrix Composite Segmented for Manufacturing High-Precision Mirrors; Plasma Treatment to Remove Carbon from Indium UV Filters; Telerobotics Workstation (TRWS) for Deep Space Habitats; Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer; On Shaft Data Acquisition System (OSDAS); ASIC Readout Circuit Architecture for Large Geiger Photodiode Arrays; Flexible Architecture for FPGAs in Embedded Systems; Polyurea-Based Aerogel Monoliths and Composites; Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds; Self-Cleaning Particulate Prefilter Media; Modular, Rapid Propellant Loading System/Cryogenic Testbed; Compact, Low-Force, Low-Noise Linear Actuator; Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link; Process for Measuring Over-Center Distances; Hands-Free Transcranial Color Doppler Probe; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores; Portable Intravenous Fluid Production Device for Ground Use; Adaptation of a Filter Assembly to Assess Microbial Bioburden of Pressurant Within a Propulsion System; Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators; Whispering Gallery Mode Optomechanical Resonator; Vision-Aided Autonomous Landing and Ingress of Micro Aerial Vehicles; Self-Sealing Wet Chemistry Cell for Field Analysis; General MACOS Interface for Modeling and Analysis for Controlled Optical Systems; Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem; Fault-Tolerant, Real-Time, Multi-Core Computer System; Water Detection Based on Object Reflections; SATPLOT for Analysis of SECCHI Heliospheric Imager Data; Plug-in Plan Tool v3.0.3.1; Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum; Nonlinear Estimation Approach to Real-Time Georegistration from Aerial Images; Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications; Low-Cost Telemetry System for Small/Micro Satellites; Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE; and Algorithms for Determining Physical Responses of Structures Under Load.

Source record↗

NASA Tech Briefs, September 1998

Topics include: special coverage on data acquisition, also, electronic components and circuits, electronic systems, software, materials, mechanics, machinery/automation, physical sciences, information sciences, This issue contains a special sections of Electronics Tech Briefs and Motion Control Tech Briefs.

Source record↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification: Preprint

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs)at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases - distribution system state estimation (DSSE) and fault identification - are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system monitoring↗

A digital CDS technique and its performance testing

Readout noise is a critical parameter for characterizing the performance of charge-coupled devices (CCDs), which can be greatly reduced by the correlated double sampling (CDS) circuit. However, a conventional CDS circuit inevitably introduces new noise since it consists of several active analog components such as operational amplifiers. This article proposes a digital CDS circuit technique, which transforms the pre-amplified CCD signal into a train of digital presentations by a high-speed data acquisition card directly without the noisy CDS circuit, then implements the digital CDS algorithm through a numerical method. A readout noise of 3.3 e - and an energy resolution of 121 eV@5.9 keV can be achieved via the digital CDS technique.

42 ENGINEERING↗

A novel digital pulse processing architecture for nuclear instrumentation

The field of nuclear instrumentation covers a wide range of applications, including counting, spectrometry, pulse shape discrimination and multi-channel coincidence. These applications are the topic of many researches, new algorithms and implementations are constantly proposed thanks to advances in digital signal processing. However, these improvements are not yet implemented in instrumentation devices. This is especially true for neutron-gamma discrimination applications which traditionally use charge comparison method while literature proposes other algorithms based on frequency domain or wavelet theory which show better performances. Another example is pileups which are generally rejected while pileup correction algorithms also exist. These processes are traditionally performed offline due to two issues. The first is the Poissonian characteristic of the signal, composed of random arrival pulses which requires to current architectures to work in data flow. The second is the real-time requirement, which implies losing pulses when the pulse rate is too high. Despite the possibility of treating the pulses independently from each other, current architectures paralyze the acquisition of the signal during the processing of a pulse. This loss is called dead-time. These two issues have led current architectures to use dedicated solutions based on re-configurable components like Field Programmable Gate Arrays (FPGAs) to overcome the need of performance necessary to deal with dead-time. However, dedicated hardware algorithm implementations on re-configurable technologies are complex and time-consuming. For all these reasons, a programmable Digital pulse Processing (DPP) architecture in a high level language such as Cor C++ which can reduce dead-time would be worthwhile for nuclear instrumentation. This would reduce prototyping and test duration by reducing the level of hardware expertise to implement new algorithms. However, today's programmable solutions do not meet the need of performance to operate online and not allow scaling with the increase in the number of measurement channel. That is why an innovative DPP architecture is proposed in this paper. This architecture is able to overcome dead-time while being programmable and is flexible with the number of measurement channel. Proposed architecture is based on an innovative execution model for pulse processing applications which can be summarized as follow. The signal is not composed of pulses only, consequently, pulses processing does not have to operate on the entire signal. Therefore, the first step of our proposal is pulse extraction by the use of dedicated components named pulse extractors. The triggering step can be achieved after the analog-to-digital conversion without any signal shaping or filtering stages. Pileup detection and accurate pulse time stamping are done at this stage. Any application downstream this step can work on adaptive variable-sized array of samples simplifying pulse processing methods. Then, once the data flow is broken, it is possible to distribute pulses on Functional Units (FUs) which perform processing. As the date of each pulse is known, they can be processed individually out-of-order to provide the results. To manage the pulses distribution, a scheduler and an interconnection network are used. pulses are distributed on the first FU which is not busy without congesting the interconnection network. For this reason, the process duration does not result anymore in dead-time if there are enough FUs. FUs are designed to be standalone and to comprises at least a programmable general purpose processor (ARM, Microblaze) allowing the implementation of complex algorithms without any modification of the hardware. An acquisition chain is composed of a succession of algorithms which lead to organize our FUs as a software macro-pipeline, A simple approach consists in assigning one algorithm per FU. Consequently, the global latency becomes the worst latency of algorithms execution on FU. Moreover, as algorithms are executed locally - i.e. on a FU - this approach limits shared memory requirement. To handle multichannel, we propose FUs sharing, this approach maximize the chance to find a non-busy FU to process an incoming pulse. This is possible since each channel receive random event independently, the pulse extractors associated to them do not necessarily need to access simultaneously to all Computing resources at the same time to distribute their pulses. The major contribution of this paper is the proposition of an execution model and its associated hardware programmable architecture for digital pulse processing that can handle multiple acquisition channels while maintaining the scalability thanks to the use of shared resources. This execution model and associated architecture are validated by simulation of a cycle accurate architecture SystemC model. Proposed architecture shows promising results in terms of scalability while maintaining zero dead-time. This work also permit the sizing of hardware resources requirement required for a predefined set of applications. Future work will focus on the interconnection network and a scheduling policy that can exploit the variable-length of pulses. Then, the hardware implementation of this architecture will be performed and tested for a representative set of application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fast, direct x-ray detection charge-coupled device

A charge-coupled device (CCD) capable of 200 Mpixels/s readout has been designed and fabricated on thick, high-resistivity silicon. The CCDs, up to 600 {mu}m thick, are fully depleted, ensuring good infrared to x-ray detection efficiency, together with a small point spread function. High readout speed, with good analog performance, is obtained by the use of a large number of parallel output ports. A set of companion 16-channel custom readout integrated circuits, capable of 15 bits of dynamic range, is used to read out the CCD. A gate array-controlled back end data acquisition system frames and transfers images, as well as provides the CCD clocks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Discrete Component Low-Noise Preamplifier Readout for a Linear (1x16) SiC Photodiode Array

A compact, low-noise and inexpensive preamplifier circuit has been designed and fabricated to optimally readout a common cathode (1x16) channel 4H-SiC Schottky photodiode array for use in ultraviolet experiments. The readout uses an operational amplifier with 10 pF capacitor in the feedback loop in parallel with a low leakage switch for each of the channels. This circuit configuration allows for reiterative sample, integrate and reset. A sampling technique is given to remove Johnson noise, enabling a femtoampere level readout noise performance. Commercial-off-the-shelf acquisition electronics are used to digitize the preamplifier analogue signals. The data logging acquisition electronics has a different integration circuit, which allows the bandwidth and gain to be independently adjusted. Using this readout, photoresponse measurements across the array between spectral wavelengths 200 nm and 370 nm are made to establish the array pixels external quantum efficiency, current responsivity and noise equivalent power.

low-noise preamplifier↗