Search NASA⌕ Search

SEARCH · Search NASA

Results for “data center efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Classical and quantum compression for edge computing: the ubiquitous data dimensionality reduction

Edge computing aims to address the challenges associated with communicating and transferring large amounts of data generated remotely to a data center in a timely and efficient manner. A central pillar of edge computing is local (i.e., at- or near-source) data processing capability so that data transfer to a data center for processing can be minimized. Data compression at the edge is therefore a natural component of edge workflows. Here we present a survey of data compression algorithms with a focus on edge computing. Not all compression algorithms can accommodate the data type heterogeneity, tight processing and communication time constraints, or energy efficiency requirement characteristics of edge computing. We discuss specific examples of compression algorithms that are being explored in the context of edge computing. We end our review with a brief survey of emerging quantum compression techniques that are of importance in quantum information processing, including the proposed concept of quantum edge computing.

97 MATHEMATICS AND COMPUTING↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Global Change Data Center: Mission, Organization, Major Activities, and 2001 Highlights

Rapid efficient access to Earth sciences data is fundamental to the Nation's efforts to understand the effects of global environmental changes and their implications for public policy. It becomes a bigger challenge in the future when data volumes increase further and missions with constellations of satellites start to appear. Demands on data storage, data access, network throughput, processing power, and database and information management are increased by orders of magnitude, while budgets remain constant and even shrink. The Global Change Data Center's (GCDC) mission is to provide systems, data products, and information management services to maximize the availability and utility of NASA's Earth science data. The specific objectives are (1) support Earth science missions be developing and operating systems to generate, archive, and distribute data products and information; (2) develop innovative information systems for processing, archiving, accessing, visualizing, and communicating Earth science data; and (3) develop value-added products and services to promote broader utilization of NASA Earth Sciences Enterprise (ESE) data and information. The ultimate product of GCDC activities is access to data and information to support research, education, and public policy.

Wharton, Stephen W.↗

Global Change Data Center: Mission, Organization, Major Activities, and 2003 Highlights

Rapid, efficient access to Earth sciences data from satellites and ground validation stations is fundamental to the nation's efforts to understand the effects of global environmental changes and their implications for public policy. It becomes a bigger challenge in the future when data volumes increase from current levels to terabytes per day. Demands on data storage, data access, network throughput, processing power, and database and information management are increased by orders of magnitude, while budgets remain constant and even shrink.The Global Change Data Center's (GCDC) mission is to develop and operate data systems, generate science products, and provide archival and distribution services for Earth science data in support of the U.S. Global Change Program and NASA's Earth Sciences Enterprise. The ultimate product of the GCDC activities is access to data to support research, education, and public policy.

FROM↗

Green Computing Opportunities & Strategy

Computation is critical to emerging fields of data intensive research, enabling new methodologies, approaches and tools. As the rate of hardware efficiency gains slows, computational time and energy costs increase. To match pace with computation demand, new approaches are needed to keep the opportunity for impact open. Charles Tripp, lead of the Green Computing Catalyzer, discusses research efforts to improve software efficiency to enable faster, less energy-intensive computing.

algorithmic efficiency↗

Enhancing the IGS Data and Products Infrastructure: A Data Center Perspective

The Data Transfer and Data Centers session will present papers on current data center activities as well as various topics geared towards enhancing the availability and acquisition of International Global Positions System Service (IGS) data and products. These topics include: strategies for reducing data file latency at IGS Data Centers, standardization of data file replacement notification methods, improving the efficiency of data file transfer among IGS Data Centers, and defining a network topology for GPS data files for use in applications.

Scharber, Michael↗

ORNL Campus Sustainability and Decarbonization using Waste Heat Recovery from the Oak Ridge Leadership Computing Facility’s High-Performance Computing Data Center

Heat pumps are a clean and efficient technology that can be powered by renewable electricity to transfer heat using a refrigerant from one place to another by different heat sources, making buildings clean and environmentally friendly. With the support of the ORNL Laboratory Modernization Division, this project explored and evaluated an innovative solution that uses water-water cost-effective midtemperature heat pump (MTHP) technology to leverage the low-grade waste heat from ORNL Frontier and the data center to deliver 85°C hot water, which replaces hot steam generated using natural gas combustion boilers for water heating or space heating in the buildings of ORNL campus. Two scenarios were studied. In the first scenario, which considered the 5600-5700-5800 complex only, Carrier’s commercial 1,000 kW MTHP technology achieves more than 6,640 MWh/year energy savings, an emission reduction of 858 TCO2e/year CO2, and a payback time of 4.85 years. In the second scenario, which considered the 5600-5700-5800 complex and Buildings 5100, 5200, and 5300, the CO2 emission reduction is 1,483 TCO2e/year, the operating cost savings are $0.21 million annually, and the payback time is 3.74 years. Additionally, a comprehensive HP ShowCase Tool was developed for evaluating the optimal solution to improve sustainability and decarbonization of the buildings on the ORNL campus. The tool is an Excel-based tool integrated with VBA (Visual Basic for Applications) coding. The tool includes collected ORNL campus building information and an MTHP library, which comprises collected commercial and ORNL-defined MTHPs. The tool was used to evaluate the sustainability and decarbonization of the ORNL campus. The tool can be widely used or referenced for heat pump solutions and building decarbonization renovation strategies to modernize ORNL facilities and energy use–intensive equipment to enable efficient, sustainable, and resilient operations in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Center High-Temperature Liquid Cooling and Heat Reuse Techno-Economic Study: Preprint

Data centers are energy-intensive facilities with growing demands for efficiency and cost-effective operations. Smaller, more distributed edge inference data centers are expected to proliferate as AI applications require low latency closer to the user of AI tools, which presents a growing opportunity to explore the systems implications of liquid cooling on water and energy use. This study analyzes the implementation of high-temperature liquid cooling systems in a prototypical inference 1-MW data center and explores the potential for heat reuse across varying climates with a goal to optimize energy efficiency, reduce capital and operational costs, and identify opportunities for high-performance cooling and water use reduction infrastructure. This analysis evaluated configurations utilizing a peak day hourly sizing and systems performance spreadsheet to evaluate design and operational conditions from which component sizes, installed cost, operational cost, and performance metrics were determined for the Base case and the Elevated case. The techno-economic analysis included heat reuse applications across a range of heat recovery temperatures and heat rejection options. The analysis shows that high-temperature liquid cooling allows for improved energy efficiency, lower water consumption, and lower capital costs compared to traditional cooling approaches. Transitioning to elevated water inlet/outlet temperatures (50 degrees C/60 degrees C) eliminates the need for chillers, cooling towers, and heat recovery equipment in many scenarios across three distinct climate zones. This results in up to 75% capital cost savings for the cooling and heat recovery equipment, and with significantly reduced water consumption, especially in non-heat reuse applications. Heat generated from data centers can also be repurposed for space heating, domestic hot water, and other applications, and is most cost-effective when data center outlet temperatures exceed 55-60 degrees C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Error Prevention Aid

In a complex computer environment there is ample opportunity for error, a mistake by a programmer, or a software-induced undesirable side effect. In insurance, errors can cost a company heavily, so protection against inadvertent change is a must for the efficient firm. The data processing center at Transport Life Insurance Company has taken a step to guard against accidental changes by adopting a software package called EQNINT (Equations Interpreter Program). EQNINT cross checks the basic formulas in a program against the formulas that make up the major production system. EQNINT assures that formulas are coded correctly and helps catch errors before they affect the customer service or its profitability.

Source record↗

GES DISC Datalist Enables Easy Data Selection For Natural Phenomena Studies

In order to investigate and assess natural hazards such as tropical storms, winter storms, volcanic eruptions, floods, and drought in a timely manner, the NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) has been developing an efficient data search and access service. Called "Datalist," this service enables users to acquire their data of interest "all at once," with minimum effort. A Datalist is a virtual collection of predefined or user-defined data variables from one or more archived data sets. Datalists are more than just data. Datalists effectively provide users with a sophisticated integrated data and services package, including metadata, citation, documentation, visualization, and data-specific services (e.g., subset and OPeNDAP), all available from one-stop shopping. The predefined Datalists, created by the experienced GES DISC science support team, should save a significant amount of time that users would otherwise have to spend. The Datalist service is an extension of the new GES DISC website, which is completely data-driven. A Datalist, also known as "data bundle," is treated just as any other data set. Being a virtual collection, a Datalist requires no extra storage space.

natural hazards↗

GES DISC Datalist Enables Easy Data Selection for Natural Phenomena Studies

In order to investigate and assess natural hazards such as tropical storms, winter storms, volcanic eruptions, floods, and drought in a timely manner, the NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) has been developing an efficient data search and access service. Called Datalist, this service enables users to acquire their data of interest all at once, with minimum effort. A Datalistis a virtual collection of predefined or user-defined data variables from one or more archived data sets. Datalistsare more than just data. Datalistseffectively provide users with a sophisticated integrated data and services package, including metadata, citation, documentation, visualization, and data-specific services (e.g., subset and OPeNDAP), all available from one-stop shopping. The predefined Datalists, created by the experienced GES DISC science support team, should save a significant amount of time that users would otherwise have to spend. The Datalistservice is an extension of the new GES DISC website, which is completely data-driven. A Datalist, also known as data bundle, is treated just as any other data set. Being a virtual collection, a Datalistrequires no extra storage space.

Earth events↗

Brochure on the 2024 ASCR Workshop on Energy-Efficient Computing for Science

Large-scale computing has enabled numerous scientific discoveries, including ground-breaking achievements facilitated by the US Department of Energy (DOE) supercomputers and advances in applied mathematics and computer science. While important advances were made in energy efficiency to enable exascale computing, continued efforts are needed to dramatically improve the energy efficiency of the next generation of high-performance computing (HPC) systems and, more broadly, AI data centers. Without substantial improvements in energy efficiency, the energy consumption associated with computing could become a limiting factor for future scientific discovery, national security, and technological advancement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New trends in photonic switching and optical networking architectures for data centers and computing systems [Invited]

The rapid increases in data traffic coupled with user preferences are driving the data center and computing system service providers to offer energy-efficient, intelligent, flexible, cost-effective, high-capacity, and low-latency data services without added complexity to the users. Disaggregated heterogeneous reconfigurable computing systems realized by photonic switching and interconnects can enhance throughput and energy efficiency for artificial intelligence/machine learning (AI/ML) workloads, especially when aided by the AI/ML-enhanced control plane. Photonic switching and new optical networking architectures are expected to solve many of these challenging problems. This paper discusses new trends in photonic switching and optical network architectures for future data centers and computing systems summarized as follows: (1) flat reconfigurable disaggregated computing enabled by high-radix photonic switching and interconnects in data centers; (2) chiplet-based computing architectures empowered by embedded photonics toward heterogeneous reconfigurable computing; (3) nanosecond-scale photonic switching in data centers and computing systems; (4) AI/ML in self-driving, application-aware, and situation-aware data centers; (5) the emergence of flexible networking for cloud computing, edge computing, and split computing, as well as flexible networking for 5G/6G RF-optical networks; and (6) the deployment of embedded co-designed silicon photonics being considered for future data centers.

Yoo, S. J. Ben (ORCID:0000000274201871)↗

Data Placement Optimization for ATLAS in a Multi-Tiered Storage System within a Data Center

Scientific experiments and computations, especially in High Energy Physics, are generating and accumulating data at an unprecedented rate. Effectively managing this vast volume of data while ensuring efficient data analysis poses a significant challenge for data centers, which must integrate various storage technologies. This paper proposes addressing this challenge by designing and developing a precise data popularity prediction model utilizing state-of-theart AI/ML techniques. This model is crafted from the analysis of ATLAS data and access patterns. It enables us to migrate infrequently accessed data to more economical storage media, such as tape drives, while storing frequently accessed data on faster yet costlier storage media like HDD or SSD. This strategic approach ensures data is placed optimally into the appropriate storage classes, thereby maximizing storage capacity while minimizing data access latency for end-users. Furthermore, the paper includes a performance evaluation of the prediction model using various key metrics such as F1 score, accuracy, precision and recall. Finally, we present a prototype use case, leveraging real-world file access data to assess the model’s impact on performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data Mining Tools Make Flights Safer, More Efficient

A small data mining team at Ames Research Center developed a set of algorithms ideal for combing through flight data to find anomalies. Dallas-based Southwest Airlines Co. signed a Space Act Agreement with Ames in 2011 to access the tools, helping the company refine its safety practices, improve its safety reviews, and increase flight efficiencies.

Source record↗

Space Communications and Navigation Validation: Extracting Data for the Strategic Center for Networking, Integration, and Communications Scheduling Algorithms

Efficiency in communication system architecture performance between Space Communications and Navigation (SCaN) assets and missions is crucial, as space communication is varied, complex, and often not utilized to its full potential. The SCaN Strategic Center for Networking, Integration, and Communications (SCENIC) new scheduling algorithms, which are designed to simulate the allocation of resources between SCaN assets and missions, have the potential to simulate an increase of this efficiency; however, they require real-world data to be validated against. The purpose of this project was to extract said validation data, which details the frequency and duration of utilized contact windows between missions and assets in the Near Earth Network (NEN), Space Network (SN), and Deep Space Network (DSN). Stored as images in daily operations summaries (DOSs), the tabular data existed in a variety of file formats such as.pdf, .docx, and .doc. Since the tables were stored as images, ABBYY® FineReader® (ABBYY Software Ltd.) optical character recognition (OCR) was implemented, which is a proprietary software that reads images from text. The comma separated value (CSV) output was utilized as input to a series of MATLAB® (The MathWorks, Inc.) methods for reformatting, at which point it was ready to be machine-read. Finally, the results were converted to a Microsoft Excel format for human readability. Along with being used for validation purposes, the data will also be used to map equipment degradation as a function of time to analyze the reliability of network assets.

Kontur, Noah P.↗

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗