Search NASA⌕ Search

SEARCH · Search NASA

Results for “data center efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Classical and quantum compression for edge computing: the ubiquitous data dimensionality reduction

Edge computing aims to address the challenges associated with communicating and transferring large amounts of data generated remotely to a data center in a timely and efficient manner. A central pillar of edge computing is local (i.e., at- or near-source) data processing capability so that data transfer to a data center for processing can be minimized. Data compression at the edge is therefore a natural component of edge workflows. Here we present a survey of data compression algorithms with a focus on edge computing. Not all compression algorithms can accommodate the data type heterogeneity, tight processing and communication time constraints, or energy efficiency requirement characteristics of edge computing. We discuss specific examples of compression algorithms that are being explored in the context of edge computing. We end our review with a brief survey of emerging quantum compression techniques that are of importance in quantum information processing, including the proposed concept of quantum edge computing.

97 MATHEMATICS AND COMPUTING↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Green Computing Opportunities & Strategy

Computation is critical to emerging fields of data intensive research, enabling new methodologies, approaches and tools. As the rate of hardware efficiency gains slows, computational time and energy costs increase. To match pace with computation demand, new approaches are needed to keep the opportunity for impact open. Charles Tripp, lead of the Green Computing Catalyzer, discusses research efforts to improve software efficiency to enable faster, less energy-intensive computing.

algorithmic efficiency↗

ORNL Campus Sustainability and Decarbonization using Waste Heat Recovery from the Oak Ridge Leadership Computing Facility’s High-Performance Computing Data Center

Heat pumps are a clean and efficient technology that can be powered by renewable electricity to transfer heat using a refrigerant from one place to another by different heat sources, making buildings clean and environmentally friendly. With the support of the ORNL Laboratory Modernization Division, this project explored and evaluated an innovative solution that uses water-water cost-effective midtemperature heat pump (MTHP) technology to leverage the low-grade waste heat from ORNL Frontier and the data center to deliver 85°C hot water, which replaces hot steam generated using natural gas combustion boilers for water heating or space heating in the buildings of ORNL campus. Two scenarios were studied. In the first scenario, which considered the 5600-5700-5800 complex only, Carrier’s commercial 1,000 kW MTHP technology achieves more than 6,640 MWh/year energy savings, an emission reduction of 858 TCO2e/year CO2, and a payback time of 4.85 years. In the second scenario, which considered the 5600-5700-5800 complex and Buildings 5100, 5200, and 5300, the CO2 emission reduction is 1,483 TCO2e/year, the operating cost savings are $0.21 million annually, and the payback time is 3.74 years. Additionally, a comprehensive HP ShowCase Tool was developed for evaluating the optimal solution to improve sustainability and decarbonization of the buildings on the ORNL campus. The tool is an Excel-based tool integrated with VBA (Visual Basic for Applications) coding. The tool includes collected ORNL campus building information and an MTHP library, which comprises collected commercial and ORNL-defined MTHPs. The tool was used to evaluate the sustainability and decarbonization of the ORNL campus. The tool can be widely used or referenced for heat pump solutions and building decarbonization renovation strategies to modernize ORNL facilities and energy use–intensive equipment to enable efficient, sustainable, and resilient operations in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Center High-Temperature Liquid Cooling and Heat Reuse Techno-Economic Study: Preprint

Data centers are energy-intensive facilities with growing demands for efficiency and cost-effective operations. Smaller, more distributed edge inference data centers are expected to proliferate as AI applications require low latency closer to the user of AI tools, which presents a growing opportunity to explore the systems implications of liquid cooling on water and energy use. This study analyzes the implementation of high-temperature liquid cooling systems in a prototypical inference 1-MW data center and explores the potential for heat reuse across varying climates with a goal to optimize energy efficiency, reduce capital and operational costs, and identify opportunities for high-performance cooling and water use reduction infrastructure. This analysis evaluated configurations utilizing a peak day hourly sizing and systems performance spreadsheet to evaluate design and operational conditions from which component sizes, installed cost, operational cost, and performance metrics were determined for the Base case and the Elevated case. The techno-economic analysis included heat reuse applications across a range of heat recovery temperatures and heat rejection options. The analysis shows that high-temperature liquid cooling allows for improved energy efficiency, lower water consumption, and lower capital costs compared to traditional cooling approaches. Transitioning to elevated water inlet/outlet temperatures (50 degrees C/60 degrees C) eliminates the need for chillers, cooling towers, and heat recovery equipment in many scenarios across three distinct climate zones. This results in up to 75% capital cost savings for the cooling and heat recovery equipment, and with significantly reduced water consumption, especially in non-heat reuse applications. Heat generated from data centers can also be repurposed for space heating, domestic hot water, and other applications, and is most cost-effective when data center outlet temperatures exceed 55-60 degrees C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Brochure on the 2024 ASCR Workshop on Energy-Efficient Computing for Science

Large-scale computing has enabled numerous scientific discoveries, including ground-breaking achievements facilitated by the US Department of Energy (DOE) supercomputers and advances in applied mathematics and computer science. While important advances were made in energy efficiency to enable exascale computing, continued efforts are needed to dramatically improve the energy efficiency of the next generation of high-performance computing (HPC) systems and, more broadly, AI data centers. Without substantial improvements in energy efficiency, the energy consumption associated with computing could become a limiting factor for future scientific discovery, national security, and technological advancement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New trends in photonic switching and optical networking architectures for data centers and computing systems [Invited]

The rapid increases in data traffic coupled with user preferences are driving the data center and computing system service providers to offer energy-efficient, intelligent, flexible, cost-effective, high-capacity, and low-latency data services without added complexity to the users. Disaggregated heterogeneous reconfigurable computing systems realized by photonic switching and interconnects can enhance throughput and energy efficiency for artificial intelligence/machine learning (AI/ML) workloads, especially when aided by the AI/ML-enhanced control plane. Photonic switching and new optical networking architectures are expected to solve many of these challenging problems. This paper discusses new trends in photonic switching and optical network architectures for future data centers and computing systems summarized as follows: (1) flat reconfigurable disaggregated computing enabled by high-radix photonic switching and interconnects in data centers; (2) chiplet-based computing architectures empowered by embedded photonics toward heterogeneous reconfigurable computing; (3) nanosecond-scale photonic switching in data centers and computing systems; (4) AI/ML in self-driving, application-aware, and situation-aware data centers; (5) the emergence of flexible networking for cloud computing, edge computing, and split computing, as well as flexible networking for 5G/6G RF-optical networks; and (6) the deployment of embedded co-designed silicon photonics being considered for future data centers.

Yoo, S. J. Ben (ORCID:0000000274201871)↗

Data Placement Optimization for ATLAS in a Multi-Tiered Storage System within a Data Center

Scientific experiments and computations, especially in High Energy Physics, are generating and accumulating data at an unprecedented rate. Effectively managing this vast volume of data while ensuring efficient data analysis poses a significant challenge for data centers, which must integrate various storage technologies. This paper proposes addressing this challenge by designing and developing a precise data popularity prediction model utilizing state-of-theart AI/ML techniques. This model is crafted from the analysis of ATLAS data and access patterns. It enables us to migrate infrequently accessed data to more economical storage media, such as tape drives, while storing frequently accessed data on faster yet costlier storage media like HDD or SSD. This strategic approach ensures data is placed optimally into the appropriate storage classes, thereby maximizing storage capacity while minimizing data access latency for end-users. Furthermore, the paper includes a performance evaluation of the prediction model using various key metrics such as F1 score, accuracy, precision and recall. Finally, we present a prototype use case, leveraging real-world file access data to assess the model’s impact on performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗

Generic and ML Workloads in an HPC Datacenter: Node Energy, Job Failures, and Node-Job Analysis

HPC datacenters offer a backbone to the modern digital society. Increasingly, they run Machine Learning (ML) jobs next to generic, compute-intensive workloads, supporting science, business, and other decision-making processes. However, understanding how ML jobs impact the operation of HPC datacenters, relative to generic jobs, remains desirable but understudied. In this work, we leverage long-term operational data, collected from a national-scale production HPC datacenter, and statistically compare how ML and generic jobs can impact the performance, failures, resource utilization, and energy consumption of HPC datacenters. Our study provides key insights, e.g., ML-related power usage causes GPU nodes to run into temperature limitations, median/mean runtime and failure rates are higher for ML jobs than for generic jobs, both ML and generic jobs exhibit highly variable arrival processes and resource demands, significant amounts of energy are spent on unsuccessfully terminating jobs, and concurrent jobs tend to terminate in the same state. We open-source our cleaned-up data traces on Zenodo (https://doi. org/10.5281/zenodo.13685426), and provide our analysis toolkit as software hosted on GitHub (https://github.com/atlarge-research/2024-icpads-hpc-workload-characterization). This study offers multiple benefits for data center administrators, who can improve operational efficiency, and for researchers, who can further improve system designs, scheduling techniques, etc.

crossanalysis↗

Automated Indexing of Structured Scientific Metadata Using Apache Solr

Scientific datasets are continuously growing with the amount of raw data being collected worldwide. This amount of data poses the biggest challenge to web search engines on how to retrieve them efficiently. This paper discusses how major scientific data centers are using popular open-source search platforms such as Solr [1] to retrieve structured data stored in data sources such as relational database management systems using its import handler mechanisms [2]. Additionally, we will also focus on how we can configure Solr to serve advanced full-text, faceted search capabilities, along with its key features, which simplify representing and delivering better performance to the scientific search interfaces.

Guntupally, Kavya↗

Energy Use in Quantum Data Centers: Scaling the Impact of Computer Architecture, Qubit Performance, Size, and Thermal Parameters

As quantum computers increase in size, the total energy used by a quantum data center, including the cooling, will become a greater concern. The cooling requirements of quantum computers, which operate at temperatures near absolute zero, are determined by computing system parameters, including the number and type of physical qubits, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. When combined with thermal system parameters such as cooling efficiency and cryostat heat transfer, the total energy use can be determined using a first-principles energy model. These models show that cooling of quantum computers differs in two fundamental ways from conventional data centers: (1) the energy required for cooling is much greater than the energy required for computation, and (2) the cooling loads are sensitive to the computational architecture. The temperature requirements for different qubit types can change energy requirements by orders of magnitude. Power use and computational power, as quantified by quantum volume, are analytically correlated. Approaches are identified for minimizing energy use in integrated quantum systems relative to computational power. Furthermore, designing a sustainable quantum computer will require both efficient cooling and system design that minimizes cooling requirements.

97 MATHEMATICS AND COMPUTING↗

Highly boosted dielectron identification in proton-proton collisions at $\sqrt{s}$ = 13 TeV

A new technique is developed to identify dielectrons (e$^+$e$^-$) with Lorentz boost $γ_\mathrm{L}$$\gt$ 20 that produce one single merged cluster in the electromagnetic calorimeter of the CMS detector. The identification uses two multivariate models: one for the case where both electron tracks are reconstructed, and another where only one of the tracks is reconstructed. The efficiency is determined using proton-proton collision data collected at a center-of-mass energy of 13 TeV. Boosted J/$ψ$ mesons decaying into e$^+$e$^-$ pairs are used to estimate the efficiency of the model with two tracks, yielding an overall efficiency of 80%. The Z $\to$ $μ^+μ^-γ$ events, where the photon converts into a collimated dielectron, are used for the model with a single track, yielding an efficiency of about 60%. A dedicated energy correction for dielectron candidates is also developed using B$^\pm$ $\to$ J/$ψ$K$^\pm$ $\to$ e$^+$e$^-$K$^\pm$ data.

Hayrapetyan, A. [Yerevan Phys. Inst.]↗

Hierarchical Analysis of Halo Center in Cosmology

Ever-increasing data size raises many challenges for scientific data analysis. Particularly in cosmological N-body simulation, finding the center of a dark matter halo suffers heavily from the large computational cost associated with the large number of particles (up to 20 million). In this work, we exploit the latent structure embed in a halo, and we propose a hierarchical approach to approximate the exact gravitational potential calculation for each particle in order to more efficiently find the halo center. Tests of our method on data from N-body simulations show that in many cases the hierarchical algorithm performs significantly faster than existing methods with a desirable accuracy.

97 MATHEMATICS AND COMPUTING↗

Enabling power measurement and control on Astra: The first petascale Arm supercomputer

Astra, deployed in 2018, was the first petascale supercomputer to utilize processors based on the ARM instruction set. The system was also the first under Sandia's Vanguard program which seeks to provide an evaluation vehicle for novel technologies that with refinement could be utilized in demanding, large-scale HPC environments. In addition to ARM, several other important first-of-a-kind developments were used in the machine, including new approaches to cooling the datacenter and machine. Here we document our experiences building a power measurement and control infrastructure for Astra. While this is often beyond the control of users today, the accurate measurement, cataloging, and evaluation of power, as our experiences show, is critical to the successful deployment of a large-scale platform. While such systems exist in part for other architectures, Astra required new development to support the novel Marvell ThunderX2 processor used in compute nodes. In addition to documenting the measurement of power during system bring up and for subsequent on-going routine use, we present results associated with controlling the power usage of the processor, an area which is becoming of progressively greater interest as data centers and supercomputing sites look to improve compute/energy efficiency and find additional sources for full system optimization.

97 MATHEMATICS AND COMPUTING↗

Alternative Fuels Data Center and Related Technology Integration Tools

The U.S. Department of Energy's (DOE) Office of Energy Efficiency and Renewable Energy's Vehicle Technologies Office (VTO) facilitates national coordination of the Clean Cities coalitions through its Technology Integration Program. VTO's Technology Integration Program supports a broad technology portfolio that can reduce transportation energy costs for businesses and consumers. Fleets, cities, and regions can use the tools featured in this guide to implement alternative fuels and advanced vehicles. Also learn how Clean Cities coalitions and their stakeholders across the country have used the tools.

47 OTHER INSTRUMENTATION↗

Alternative Fuels Data Center and Related Technology Integration Tools

The U.S. Department of Energy's (DOE) Office of Energy Efficiency and Renewable Energy's Vehicle Technologies Office (VTO) facilitates national coordination of the Clean Cities coalitions through its Technology Integration Program. VTO's Technology Integration Program supports a broad technology portfolio that can reduce transportation energy costs for businesses and consumers. Fleets, cities, and regions can use the tools featured in this guide to implement alternative fuels and advanced vehicles. Also learn how Clean Cities coalitions and their stakeholders across the country have used the tools.

AFDC↗

Considerations for Distributed Edge Data Centers and Use of Building Loads to Support Large Interconnections

The rapid expansion of artificial intelligence (AI) and machine learning is driving unprecedented electricity demand from data centers. It is predicted that by 2030, 90% of AI workloads will be inference-based, requiring interconnection of multiple low-latency edge data centers (<20 MW) sited closer to end users - often on already constrained distribution feeders. Although individually small, these loads can aggregate to large loads per feeder, straining infrastructure, creating multi-year interconnection delays, and driving up customer costs. This paper proposes a data center-focused grid-integration framework that combines feeder hosting capacity analysis with building energy efficiency, building load flexibility, and waste heat reuse to expand effective feeder and substation headroom. Such approaches can reduce interconnection delays, lower costs for ratepayers, and accelerate AI-ready infrastructure deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗