Search NASA⌕ Search

SEARCH · Search NASA

Results for “data fidelity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

AMTS update for STTR

Advanced nuclear reactor systems currently in development include designs that utilize higher energy neutron spectrums, higher temperatures, and corrosive environments that are quite different from the current fleet of nuclear power plants in use today. As a result, new structural materials must be developed and qualified for use to support these advanced systems. For example, research is currently being conducted on a new class of materials known as multi-principle-element-alloys. These alloys show some promise to be able to meet the structural needs of these challenging reactor systems. However, due to the vast available compositional space, and the limited amount of research conducted thus far, Idaho National Laboratory (INL)sought a way to advanced mechanical testing capability for highly irradiated structural materials to increase both throughput and higher fidelity data analysis through incorporation of digital image correlation. The Automated Mechanical Testing System accomplishes these tasks by automating the testing and incorporating digital image correlation to provide higher fidelity data. INL has now received this system and is currently performing functional testing and training. INL is also performing some modifications to the system to allow for installation into a remote shielded enclosure where testing of irradiated structural materials can be performed. After testing, training, and modifications of the system are complete, INL will install the system into a shielded enclosure and begin using the system to test irradiated structural materials.

36 MATERIALS SCIENCE↗

Nimbus-earth radiation budget sensor characterization for improved data reduction fidelity

Detailed characterizations of flight spare earth flux sensors from the Nimbus Earth Radiation Budget (ERB) program have been performed which, when coupled with a more careful accounting of the orbital instrument environment, provide the potential for improved accuracy in the final data products. The characterizations included detailed field-of-view mappings, responses to transient long and short wavelength radiation, and response to sensor temperature changes. These sensor and environment characterizations, along with the outstanding low noise and stability properties of the ERB instrument signal processing system, promise improvement of the data accuracy to levels sufficient for long-term budget and climatological purposes. The combined data sets from Nimbus 6 and 7 are expected to span a period in excess of 10 years. The improvements in data accuracy are particularly significant over zonal latitude bands because the corrections are strongly latitude dependent.

Maschhoff, R.↗

Exploiting Colorimetry for Fidelity in Data Visualization

Advances in multimodal characterization methods fuel the generation of increasing immense hyper-dimensional data sets. Color mapping is employed for conveying higher dimensional data in two-dimensional (2D) representations for human consumption without relying on multiple projections. How one constructs these color maps, however, critically affects how accurately one perceives data. For simple scalar fields, perceptually uniform color maps and color selection have been shown to improve data readability and interpretation across research fields. In this work, we review core concepts underlying the design of perceptually uniform color maps and extend the concepts from scalar fields to two-dimensional vector fields and three-component composition fields frequently found in materials-chemistry research to enable high-fidelity visualization. Additionally, we develop the software tools PAPUC and CMPUC to enable researchers to utilize these colorimetry principles and employ perceptually uniform color spaces for rigorously meaningful color mapping of higher dimensional data representations. Last, we demonstrate how these approaches deliver immediate improvements in data readability and interpretation in microscopies and spectroscopies routinely used in discerning materials structure, chemistry, and properties.

36 MATERIALS SCIENCE↗

Toward High-Quality X-59 Sonic Thump Measurements

Brigham Young University has been investigating best practices for recommendation to NASA in upcoming X-59 sonic thump measurements. This preparatory work has focused both on obtaining high-fidelity data and standardizing signal analysis techniques for sonic thumps. Included in the research are topics such as whether to use a ground-based or elevated microphone, how to use low-noise microphones and still recover high-fidelity data at low frequencies, and estimating the uncertainty in a given measurement due to local atmospheric turbulence effects. Also included is a study of windowing techniques, zero padding, and the removal of high-frequency ambient noise contamination.

sonic boom↗

High-fidelity wave data from MarineLabs CoastScout™ buoys supporting WEC demonstration at Scripps Pier

Two MarineLabs CoastScout™ buoys were deployed off La Jolla, California in February 2020 to provide high-resolution wave elevation time series data in support of CalWave Power Technologies’ XWave WEC deployment. The buoys are positioned approximately 300m from a longterm wave monitoring station operated by the Coastal Data Information Program. Both CoastScout hull types showed excellent agreement with the reference Datawell Directional Waverider MkIII (Hs r 2 =0.94, m0 r 2 =0.88). The CoastScout buoys maintained 100% uptime throughout an initial 6- month intercomparison period. CalWave used 5-Hz wave train data from this period to drive physical hardware-in-the-loop tests of the XWave power take-off. Throughout the deployment, the CoastScout buoys will provide near-real-time bulk wave parameters to help CalWave operators safely and efficiently operate the WEC. In post-processing, high-fidelity wave resolution will be used to associate individual waves with onboard measurements from Fiber Bragg Grating strain gauges and external pressure sensors.

16 TIDAL AND WAVE POWER↗

SU-E-J-246: A Deformation-Field Map Based Liver 4D CBCT Reconstruction Method Using Gold Nanoparticles as Constraints

Purpose: To investigate the feasibility of using nanoparticle markers to validate liver tumor motion together with a deformation field map-based four dimensional (4D) cone-beam computed tomography (CBCT) reconstruction method. Methods: A technique for lung 4D-CBCT reconstruction has been previously developed using a deformation field map (DFM)-based strategy. In this method, each phase of the 4D-CBCT is considered as a deformation of a prior CT volume. The DFM is solved by a motion modeling and free-form deformation (MM-FD) technique, using a data fidelity constraint and the deformation energy minimization. For liver imaging, there is low contrast of a liver tumor in on-board projections. A validation of liver tumor motion using implanted gold nanoparticles, along with the MM-FD deformation technique is implemented to reconstruct onboard 4D CBCT liver radiotherapy images. These nanoparticles were placed around the liver tumor to reflect the tumor positions in both CT simulation and on-board image acquisition. When reconstructing each phase of the 4D-CBCT, the migrations of the gold nanoparticles act as a constraint to regularize the deformation field, along with the data fidelity and the energy minimization constraints. In this study, multiple tumor diameters and positions were simulated within the liver for on-board 4D-CBCT imaging. The on-board 4D-CBCT reconstructed by the proposed method was compared with the “ground truth” image. Results: The preliminary data, which uses reconstruction for lung radiotherapy suggests that the advanced reconstruction algorithm including the gold nanoparticle constraint will Resultin volume percentage differences (VPD) between lesions in reconstructed images by MM-FD and “ground truth” on-board images of 11.5% (± 9.4%) and a center of mass shift of 1.3 mm (± 1.3 mm) for liver radiotherapy. Conclusion: The advanced MM-FD technique enforcing the additional constraints from gold nanoparticles, results in improved accuracy for reconstructing on-board 4D-CBCT of liver tumor. Varian medical systems research grant.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-04: Estimating 4D CBCT from Prior Information and Extremely Limited Angle Projections Using Structural PCA and Weighted Free-Form Deformation

Purpose: To investigate the feasibility of using structure-based principal component analysis (PCA) motion-modeling and weighted free-form deformation to estimate on-board 4D-CBCT using prior information and extremely limited angle projections for potential 4D target verification of lung radiotherapy. Methods: A technique for lung 4D-CBCT reconstruction has been previously developed using a deformation field map (DFM)-based strategy. In the previous method, each phase of the 4D-CBCT was generated by deforming a prior CT volume. The DFM was solved by a motion-model extracted by global PCA and a free-form deformation (GMM-FD) technique, using data fidelity constraint and the deformation energy minimization. In this study, a new structural-PCA method was developed to build a structural motion-model (SMM) by accounting for potential relative motion pattern changes between different anatomical structures from simulation to treatment. The motion model extracted from planning 4DCT was divided into two structures: tumor and body excluding tumor, and the parameters of both structures were optimized together. Weighted free-form deformation (WFD) was employed afterwards to introduce flexibility in adjusting the weightings of different structures in the data fidelity constraint based on clinical interests. XCAT (computerized patient model) simulation with a 30 mm diameter lesion was simulated with various anatomical and respirational changes from planning 4D-CT to onboard volume. The estimation accuracy was evaluated by the Volume-Percent-Difference (VPD)/Center-of-Mass-Shift (COMS) between lesions in the estimated and “ground-truth” on board 4D-CBCT. Results: Among 6 different XCAT scenarios corresponding to respirational and anatomical changes from planning CT to on-board using single 30° on-board projections, the VPD/COMS for SMM-WFD was reduced to 10.64±3.04%/1.20±0.45mm from 21.72±9.24%/1.80±0.53mm for GMM-FD. Using 15° orthogonal projections, the VPD/COMS was further reduced to 1.91±0.86%/0.31±0.42mm based on SMM-WFD. Conclusion: Compared to GMM-FD technique, the SMM-WFD technique can substantially improve the 4D-CBCT estimation accuracy using extremely small scan angles to provide ultra-fast 4D verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

A limited-angle intrafraction verification (LIVE) system for radiation therapy

Purpose: Currently, no 3D or 4D volumetric x-ray imaging techniques are available for intrafraction verification of target position during actual treatment delivery or in-between treatment beams, which is critical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. This study aims to develop a limited-angle intrafraction verification (LIVE) system to use prior information, deformation models, and limited angle kV-MV projections to verify target position intrafractionally. Methods: The LIVE system acquires limited-angle kV projections simultaneously during arc treatment delivery or in-between static 3D/IMRT treatment beams as the gantry moves from one beam to the next. Orthogonal limited-angle MV projections are acquired from the beam's eye view (BEV) exit fluence of arc treatment beam or in-between static beams to provide additional anatomical information. MV projections are converted to kV projections using a linear conversion function. Patient prior planning CT at one phase is used as the prior information, and the on-board patient volume is considered as a deformation of the prior images. The deformation field is solved using the data fidelity constraint, a breathing motion model extracted from the planning 4D-CT based on principal component analysis (PCA) and a free-form deformation (FD) model. LIVE was evaluated using a 4D digital extended cardiac torso phantom (XCAT) and a CIRS 008A dynamic thoracic phantom. In the XCAT study, patient breathing pattern and tumor size changes were simulated from CT to treatment position. In the CIRS phantom study, the artificial target in the lung region experienced both size change and position shift from CT to treatment position. Varian Truebeam research mode was used to acquire kV and MV projections simultaneously during the delivery of a dynamic conformal arc plan. The reconstruction accuracy was evaluated by calculating the 3D volume percentage difference (VPD) and the center of mass (COM) difference of the tumor in the true on-board images and reconstructed images. Results: In both simulation and phantom studies, LIVE achieved substantially better reconstruction accuracy than reconstruction using PCA or FD deformation model alone. In the XCAT study, the average VPD and COM differences among different patient scenarios for LIVE system using orthogonal 30° scan angles were 4.3% and 0.3 mm when using kV+BEV MV. Reducing scan angle to 15° increased the average VPD and COM differences to 15.1% and 1.7 mm. In the CIRS phantom study, the VPD and COM differences for the LIVE system using orthogonal 30° scan angles were 6.4% and 1.4 mm. Reducing scan angle to 15° increased the VPD and COM differences to 51.9% and 3.8 mm. Conclusions: The LIVE system has the potential to substantially improve intrafraction target localization accuracy by providing volumetric verification of tumor position simultaneously during arc treatment delivery or in-between static treatment beams. With this improvement, LIVE opens up a new avenue for margin reduction and dose escalation in both fractionated treatments and SRS and SBRT treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Milestone 7714 National Opacity Program: High-Fidelity Iron Data on NIF

Establish the level of reproducibility of NIF iron opacity shots, quantify to-date improvements in data quality through, e.g. background reduction, improved signal, and improved analysis methods, and formalize the approach that will be taken in the future to compare NIF data, Z data, and theory.

74 ATOMIC AND MOLECULAR PHYSICS↗

Subsampling of Parametric Models with Bifidelity Boosting

Least squares regression is a ubiquitous tool for building emulators (a.k.a. surrogate models) of problems across science and engineering for purposes such as design space exploration and uncertainty quantification. When the regression data are generated using an experimental design process (e.g., a quadrature grid) involving computationally expensive models, or when the data size is large, sketching techniques have shown promise at reducing the cost of the construction of the regression model while ensuring accuracy comparable to that of the full data. However, random sketching strategies, such as those based on leverage scores, lead to regression errors that are random and may exhibit large variability. To mitigate this issue, we present a novel boosting approach that leverages cheaper, lower-fidelity data of the problem at hand to identify the best sketch among a set of candidate sketches. This in turn specifies the sketch of the intended high-fidelity model and the associated data. We provide theoretical analyses of this bifidelity boosting (BFB) approach and discuss the conditions the low- and high-fidelity data must satisfy for a successful boosting. In doing so, we derive a bound on the residual norm of the BFB sketched solution relating it to its ideal, but computationally expensive, high-fidelity boosted counterpart. Finally, empirical results on both manufactured and PDE data corroborate the theoretical analyses and illustrate the efficacy of the BFB solution in reducing the regression error, as compared to the nonboosted solution.

97 MATHEMATICS AND COMPUTING↗

Towards the clinical implementation of iterative low-dose cone-beam CT reconstruction in image-guided radiation therapy: Cone/ring artifact correction and multiple GPU implementation

Purpose: Compressed sensing (CS)-based iterative reconstruction (IR) techniques are able to reconstruct cone-beam CT (CBCT) images from undersampled noisy data, allowing for imaging dose reduction. However, there are a few practical concerns preventing the clinical implementation of these techniques. On the image quality side, data truncation along the superior–inferior direction under the cone-beam geometry produces severe cone artifacts in the reconstructed images. Ring artifacts are also seen in the half-fan scan mode. On the reconstruction efficiency side, the long computation time hinders clinical use in image-guided radiation therapy (IGRT). Methods: Image quality improvement methods are proposed to mitigate the cone and ring image artifacts in IR. The basic idea is to use weighting factors in the IR data fidelity term to improve projection data consistency with the reconstructed volume. In order to improve the computational efficiency, a multiple graphics processing units (GPUs)-based CS-IR system was developed. The parallelization scheme, detailed analyses of computation time at each step, their relationship with image resolution, and the acceleration factors were studied. The whole system was evaluated in various phantom and patient cases. Results: Ring artifacts can be mitigated by properly designing a weighting factor as a function of the spatial location on the detector. As for the cone artifact, without applying a correction method, it contaminated 13 out of 80 slices in a head-neck case (full-fan). Contamination was even more severe in a pelvis case under half-fan mode, where 36 out of 80 slices were affected, leading to poorer soft tissue delineation and reduced superior–inferior coverage. The proposed method effectively corrects those contaminated slices with mean intensity differences compared to FDK results decreasing from ∼497 and ∼293 HU to ∼39 and ∼27 HU for the full-fan and half-fan cases, respectively. In terms of efficiency boost, an overall 3.1 × speedup factor has been achieved with four GPU cards compared to a single GPU-based reconstruction. The total computation time is ∼30 s for typical clinical cases. Conclusions: The authors have developed a low-dose CBCT IR system for IGRT. By incorporating data consistency-based weighting factors in the IR model, cone/ring artifacts can be mitigated. A boost in computational efficiency is achieved by multi-GPU implementation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗