Search NASASearch

SEARCH · Search NASA

Results for “detector alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Alternative solenoid compensation scheme for the FCC-ee interaction region

We present the optics design of the solenoid compensation scheme at the FCC-ee. The 2T solenoids from the experiments induce coupling on the beams, generating an increase on vertical emittance. This compensation scheme minimizes emittance growth, with a final value of approximately 5% of the nominal. A screening solenoid is placed around the Final Focus Quadrupoles to protect them from the experiment’s field. A skew quadrupole component is added to the Final Doublet, aligning the magnet axis to the rotated reference frame of the beam. Two anti-solenoids placed approximately ±20 m from the IP are used to cancel the field integral. The vertical orbit generated by the horizontal crossing angle in the detector field is compensated by vertical correctors placed right after the beam pipe separation and next to the final focus quadrupoles. We describe the IR optics in this scheme, including the detector solenoid and the magnetic elements used for compensation.

43 PARTICLE ACCELERATORS

Searching for Sterile Neutrinos Using an Exclusive 1$\mu$;1$\rho$ Selection: The Short Baseline Near Detector (SBND)

Over the last two decades, we have seen several of short-baseline neutrino oscillation experiments report results which challenged mainstream theories of neutrino oscillations. On the forefront of exploring these anomalies further is Fermilab's Short-Baseline Neutrino (SBN) program, which consists of two large liquid argon time projection chambers (LArTPCs), SBND and ICARUS, placed in alignment with the Booster Neutrino Beam (BNB). I'll be showing the strength that a 1mu1p selection at the SBN program can have for delivering world-leading sensitivity to distortions in the muon neutrino spectrum due to sterile neutrino oscillations.

Rowe, Nathaniel [Chicago U.]

Bayesian Exploration and Surrogate Emulation of Nonlinear Beam-Response Geometry in the LBNF Beamline

Next-generation long-baseline neutrino experiments aim to achieve multi-MW proton beam power while reducing accelerator-induced systematic uncertainties. At Fermilab, the LBNF beamline is designed for 1.2 MW operation with PIP-II and is upgradeable to 2.4 MW. DUNE will probe the three-flavor neutrino paradigm and search for CP violation, requiring precise neutrino-flux normalization and improved control of accelerator-related uncertainties. Within the LBNF beamline, the System for On-Axis Neutrino Detection (SAND) will constrain flux uncertainties using precision near-detector measurements, while the Muon Monitor System (MuMS) will provide beamline diagnostics sensitive to the proton beam, target, and horn configuration. However, the pion phase space relevant for DUNE depends simultaneously on many correlated parameters, including beam centroid, beam width, horn current and alignment, target position, optics shifts, and radiation-induced changes. Consequently, MuMS observables exhibit nonlinear and coupled responses that are difficult to characterize using traditional one-parameter scans. To address this challenge, we are developing a Bayesian Exploration framework coupled to physics-informed surrogate emulators trained on Geant4 beamline simulations. Gaussian-process emulators provide both fast predictions and uncertainty estimates, enabling adaptive selection of new simulation points in beam-parameter space. As an initial demonstration, we construct surrogate emulators for MuMS response observables using a verified simulation campaign spanning proton-beam steering conditions. The emulators reproduce the simulated dependence of MuMS centroid and gradient observables while providing predictive uncertainties, and serve as the foundation for future multidimensional exploration including beam width, horn current, and additional beamline parameters. This work establishes a framework for uncertainty-aware beam monitoring, adaptive simulation campaigns, and rapid beam-response inference for future DUNE operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT

Development of a military-specific mesh-type computational phantom library and its application to internal dosimetry and in-field radiological triage screening

Estimates of organ-absorbed and committed doses to individuals exposed to radioactive materials via acute inhalation often rely on internal dose coefficients and detector responses from reference human computational models. To achieve more accurate dose assessments to United States Armed Forces service members exposed in-field, computational models with varying morphometric parameters representative of this population are necessary. The International Commission on Radiological Protection (ICRP) Publication 145 provides detailed mesh reference computational phantoms (MRCPs) for adult males and females, with morphometric parameters matched to the 50th percentile. Previously, these phantoms were 2D and 3D scaled to match desired height, mass, and secondary anthropomorphic parameters in the creation of the University of Florida / Memorial Sloan Kettering (UF/MSK) computational phantom library. To achieve body fat percentage targets required for accession into the US Armed Forces, muscle and fat volumes were adjusted accordingly, thus, creating the UF/Department of Defence computational phantom library presented in this study. A comprehensive library of mesh-type computational human phantoms was created, including 57 adult males and 49 adult females with morphometric parameters aligned with United States Armed Forces service members. Phantoms were restricted to a body mass index between 19 and 27.5, with body fat percentages below 26% for males and 36% for females. Specific absorbed fractions were computed for selected source and target combinations, demonstrating how variations in height and body mass influence energy absorption in target regions relative to the ICRP MRCPs. Radiation detector responses were also computed, revealing that higher body masses resulted in decreased registered counts in the detection volume. These findings highlight the importance of incorporating morphometric variability in computational phantoms to achieve more accurate dose assessments and radiation detection responses for United States Armed Forces service members who inhale radioactive materials in-field.

computational phantoms

Measurement and Modeling of Polarized Atmosphere at the South Pole with SPT-3G

We present the detection and characterization of fluctuations in linearly polarized emission from the atmosphere above the South Pole. These measurements make use of data from the SPT-3G receiver on the South Pole Telescope in three frequency bands centered at 95, 150, and 220 GHz. We use the cross-correlation between detectors to produce an unbiased estimate of the power in Stokes I, Q, and U parameters on large angular scales. Our results are consistent with the polarized signal being produced by the combination of Rayleigh scattering of thermal radiation from the ground and thermal emission from a population of horizontally aligned ice crystals with an anisotropic distribution described by Kolmogorov turbulence. The measured spatial scaling, frequency scaling, and elevation dependence of the polarized emission are explained by this model. Polarized atmospheric emission has the potential to significantly impact observations on the large angular scales being targeted by searches for inflationary B-mode CMB polarization. We present the distribution of measured angular power spectrum amplitudes in Stokes Q and I for 4 yr of Austral winter observations, which can be used to simulate the impact of atmospheric polarization and intensity fluctuations at the South Pole on a specified experiment and observation strategy. We present a mitigation strategy that involves both downweighting significantly contaminated observations and subtracting a polarized atmospheric signal from the 150 GHz band maps. In observations with the SPT-3G instrument, the polarized atmospheric signal is a well-understood and subdominant contribution to the measured noise after implementing the mitigation strategies described here.

79 ASTRONOMY AND ASTROPHYSICS

Optimization Studies of Radiation Shielding for PIP-II Project at Fermilab

The Proton Improvement Plan-II (PIP-II) at Fermilab represents a significant advancement in the quest to answer some of the most profound questions about our universe using the world's most intense high-energy neutrino beam. The project requires the construction of a new addition to the Fermilab accelerator complex – an 800-MeV high-intensity superconducting linear accelerator. Ensuring the safety and regulatory compliance of this ambitious project is paramount, necessitating thorough dose rate assessments under both normal operational and accidental scenarios to align with the Fermilab Radiological Control Manual (FRCM) standards. Our approach included a shielding optimization used for the simulations with the Monte Carlo code MARS [1,2,3] to incorporate new magnet and collimator designs, essential for reflecting the current state of PIP-II infrastructure. The implementation of high-resolution detector planes, despite their computational demands, enabled us to gather detailed radiation field data crucial for optimizing shielding configurations. To overcome the significant computational demands, we developed a branching code that drastically reduced simulation runtimes while maintaining statistical integrity. This was achieved through geometry splitting and the application of Russian Roulette techniques, tailored to prioritize regions of interest based on predefined importances and weight limits.

43 PARTICLE ACCELERATORS

Optimization Studies of Radiation Shielding for PIP-II Project at Fermilab

The Proton Improvement Plan-II (PIP-II) at Fermilab represents a significant advancement in the quest to answer some of the most profound questions about our universe using the world's most intense high-energy neutrino beam. The project requires the construction of a new addition to the Fermilab accelerator complex – an 800-MeV high-intensity superconducting linear accelerator. Ensuring the safety and regulatory compliance of this ambitious project is paramount, necessitating thorough dose rate assessments under both normal operational and accidental scenarios to align with the Fermilab Radiological Control Manual (FRCM) standards. Our approach included a shielding optimization used for the simulations with the Monte Carlo code MARS [1,2,3] to incorporate new magnet and collimator designs, essential for reflecting the current state of PIP-II infrastructure. The implementation of high-resolution detector planes, despite their computational demands, enabled us to gather detailed radiation field data crucial for optimizing shielding configurations. To overcome the significant computational demands, we developed a branching code that drastically reduced simulation runtimes while maintaining statistical integrity. This was achieved through geometry splitting and the application of Russian Roulette techniques, tailored to prioritize regions of interest based on predefined importances and weight limits.

Makovec, Alajos

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES

Patch-Based Convolutional Neural Networks for Multiple Microstructural Features Detection in FIB-SEM Micrographs of Irradiated Nuclear Fuel

Focused ion beam scanning electron microscopy (FIB-SEM) tomography has increasingly been utilized for acquiring three-dimensional (3D) microstructure features at the sub-micron scale in irradiated nuclear materials. This technique involves sequential ion beam slicing followed by electron beam imaging and compositional mapping using energy dispersive spectroscopy (EDS). Despite its growing use, several challenges persist. These include the time-intensive nature of data collection of EDS data, difficulties in distinguishing between various microstructures, and issues with image alignment. These challenges currently limit the broader application of FIB-SEM tomography in the field. To overcome these limitations, we propose using convolutional neural networks (CNNs) to automate microstructure identification in SEM images. Our study introduces a new framework for identifying microstructures in irradiated U-10Zr (wt. %) metallic fuel with limited annotated data. The framework includes the creation of a reliable annotated dataset with paired SEM and ground truth data from EDS maps, the applications of CNNs for microstructure identification, and the validation of model performance. Specifically, we employed the Segment Anything Model (SAM) to align SEM images with corresponding EDS maps and focused ion beam (FIB) tomography SEM data. We evaluate several models, including Patch-based U-Net, Attention U-Net, and Residual U-Net, finding that patch-based U-Net exhibits superior segmentation performance and consistency. This approach reduces reliance on EDS detectors and aids in accelerating nuclear material analysis process, highlighting the potential of advanced deep learning techniques to improve microstructural understanding in nuclear material. This is the first framework to integrate SAM and Patch-based CNN models for semantic segmentation of irradiated nuclear materials, with potential applicability to other tomography datasets.

36 - MATERIALS SCIENCE

Performance of the CMS electromagnetic calorimeter in pp collisions at √$_{s}$ = 13 TeV

The operation and performance of the Compact Muon Solenoid(CMS) electromagnetic calorimeter (ECAL) are presented, based ondata collected in pp collisions at√$_{s}$ =13 TeV at the CERN LHC, in the years from 2015 to 2018(LHC Run 2), corresponding to an integrated luminosity of151 fb$^{-1}$. The CMS ECAL is a scintillating lead-tungstatecrystal calorimeter, with a silicon strip preshower detector in theforward region that provides precise measurements of the energy andthe time-of-arrival of electrons and photons. The successfuloperation of the ECAL is crucial for a broad range of physics goals,ranging from observing the Higgs boson and measuring its properties,to other standard model measurements and searches for newphenomena. Precise calibration, alignment, and monitoring of theECAL response are important ingredients to achieve these goals. Toface the challenges posed by the higher luminosity, whichcharacterized the operation of the LHC in Run 2, the proceduresestablished during the 2011–2012 run of the LHC have been revisitedand new methods have been developed for the energy measurement andfor the ECAL calibration. The energy resolution of the calorimeter,for electrons from Z boson decays reaching theECAL without significant loss of energy by bremsstrahlung, wasbetter than 1.8%, 3.0%, and 4.5% in the |η| intervals[0.0,0.8], [0.8,1.5], [1.5, 2.5], respectively. This resultingperformance is similar to that achieved during Run 1 in 2011–2012,in spite of the more severe running conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Precision measurement of the B0 meson lifetime using B0→J/ψK∗0 decays with the ATLAS detector

A measurement of the B0$$B^{0}$$ meson lifetime using B0→J/ψK∗0$$ B^{0} \rightarrow J/\psi K^{*0} $$ decays in data from 13 TeV$$\text {TeV}$$ proton–proton collisions with an integrated luminosity of 140fb-1$$ 140~\mathrm {fb^{-1}} $$ recorded by the ATLAS detector at the LHC is presented. The measured effective lifetime is τ=1.5053±0.0012(stat.)±0.0035(syst.)ps.$$ \tau = 1.5053\pm 0.0012~\mathrm {(stat.)} \pm 0.0035~\mathrm {(syst.)~ps}. $$The average decay width extracted from the effective lifetime, using parameters from external sources, is Γd=0.6639±0.0005(stat.)±0.0016(syst.)±0.0038(ext.)ps-1,$$\begin{aligned} \Gamma _d = 0.6639\pm 0.0005~\mathrm {(stat.)} \pm 0.0016~\mathrm {(syst.)}\\ \pm 0.0038~\text {(ext.)} \text {~ps}^{-1}, \end{aligned}$$where the uncertainties are statistical, systematic and from external sources. The earlier ATLAS measurement of Γs$$\Gamma _s$$ in the Bs0→J/ψϕ$$B^{0}_{s} \rightarrow J/\psi \phi $$ decay was used to derive a value for the ratio of the average decay widths Γd$$\Gamma _d$$ and Γs$$\Gamma _s$$ for B0$$B^{0} $$ and Bs0$$B^{0}_{s} $$ mesons respectively, of ΓdΓs=0.9905±0.0022(stat.)±0.0036(syst.)±0.0057(ext.).$$ \frac{\Gamma _d }{\Gamma _s } = 0.9905\pm 0.0022~\text {(stat.)} \pm 0.0036~\text {(syst.)} \pm 0.0057~\text {(ext.)}. $$The measured lifetime, average decay width and decay width ratio are in agreement with theoretical predictions and with measurements by other experiments. This measurement provides the most precise result of the effective lifetime of the B0$$B^{0}$$ meson to date.

Aad, G

Image Alignment and Flat-Field Correction of Film and Computed Radiography Images on the LLNL Flash Testbed

Computed radiography (CR) imaging plates and film are used in HEAF firing tanks and in the NDE group. The imaging plates allow for the creation of high-resolution digital images with flash X-ray (FXR). A typical treatment of flash X-ray radiographs is flat-field correction, where the image from an experiment is normalized by a “flat-field” or “bright-field” image. This flat-field image is taken in an identical configuration to the experimental image, but without the object or experiment in the field of view (FOV). This treatment reduces spatial effects from the FXR spot size and detector misalignment, as each pixel value in the corrected image represents a ratio of collected radiation with the object in FOV to the collected radiation without the object in FOV. One challenge in the creation of a corrected image is the misalignment of the CR plate or film pack between capturing the flat-field image and the experimental image. Fiducial structures can remedy this issue. Small (3.18mm) stainless steel ball bearings serve as good fiducial structures due to their small size and high radiographic contrast. Spheres are view-agnostic geometry, always presenting a circular cross section no matter the orientation. This process was developed for images from the flash X-ray testbed. The flash testbed was used to compare the X-ray transmission at different thicknesses of aluminum and copper step wedges. Each step wedge section is a rectangular shape, so evaluation is made much simpler if the rectangles are not rotated with respect to the image. This alignment process aligns the object and flat-field images together and leaves the rectangles of each step aligned with the image.

36 MATERIALS SCIENCE

Time-reversed Young’s experiment: Deterministic, diffractionless second-order interference effect

The classic Young’s double-slit experiment exhibits first-order interference, producing alternating bright and dark fringes shaped by the diffraction effect of the slits. In contrast, here we demonstrate that its time-reversed configuration generates an ideal, deterministic second-order ‘ghost’ interference pattern free from diffraction and first-order effects with the use of only a position-fixed detector. The pattern’s size is governed by the dimensions of the ‘effectively extended light source’ formed by point emitter(s). Beyond highlighting the nonreciprocal physics between the two configurations, this system unlocks a range of novel phenomena inaccessible in traditional double-slit experiments. These include fully programmable, digitized interference fringe formations and the ability to align the pattern plane with the source plane on the same side of the setup. Remarkably, our proposed experiment achieves these outcomes without relying on nonclassical correlations or quantum entanglement. Here, by restoring time-reversal symmetry and eliminating diffraction, our theoretical analysis reveals that this approach offers exciting potential for advancing optical imaging and sensing technologies with improved transverse and longitudinal phase-shift sensitivity and resolution limit beyond current limitations.

74 ATOMIC AND MOLECULAR PHYSICS

Elimination LArTPC Simulation Uncertainty

Liquid Argon Time Projection Chambers (LArTPC) are crucial for measuring muons and neutrinos by capturing the paths of fast-moving particles through argon gas. However, these detectors face challenges such as electron-ion recombination, diffusion, and attenuation, which introduce uncertainties in simulation models. This study, conducted by Ka ren Mkrtchyan at FERMILAB, aims to reduce these uncertainties by adjusting the amplitude and width of signals detected by the TPC wires. Initial findings indicate that the current modification algorithm requires further refinement to better align simulations with observed data. Ongoing work focuses on correcting computational bugs and enhancing the simulation model for improved accuracy and statistical confidence.

Mkrtchyan, Ka'ren

Precise measurement of the tt¯ production cross-section and lepton differential distributions in eμ dilepton events from s=13TeVpp collisions with the ATLAS detector

The inclusive top quark pair (tt¯$$t\bar{t}$$) cross-section σtt¯$$\sigma _{t\bar{t}}$$ has been measured in proton–proton collisions at s=13TeV$$\sqrt{s}=13\,\text {TeV}$$, using 140fb-1$$140\,{\text {fb}^{-1}} $$ of data collected by the ATLAS experiment at the Large Hadron Collider. Using events with an opposite-charge eμ$$e\mu $$ pair and b-tagged jets, the cross-section is measured to be: σtt¯=829.3±1.3(stat)±8.0(syst)±7.3(lumi)±1.9(beam)pb,$$\begin{aligned} \sigma _{t\bar{t}} & = 829.3\pm 1.3\,\mathrm {(stat)}\ \pm 8.0\,\mathrm {(syst)}\ \pm 7.3\,\mathrm {(lumi)}\ \\ & \quad \pm 1.9\,\mathrm {(beam)}\,\textrm{pb}, \end{aligned}$$where the uncertainties reflect the limited size of the data sample, experimental and theoretical systematic effects, the integrated luminosity, and the proton beam energy, giving a total uncertainty of 1.3%. The result is used to determine the top quark pole mass via the dependence of the predicted cross-section on mtpole$${m_{t}^\textrm{pole}}$$, giving mtpole=172.8-1.7+1.5$${m_{t}^\textrm{pole}}=172.8^{+1.5}_{-1.7}$$ GeV$$\text {GeV}$$. The same event sample is used to measure absolute and normalised differential cross-sections for the tt¯→eμνν¯bb¯$$t\bar{t} \rightarrow e\mu u \bar{ u }b\bar{b} $$ process as a function of single-lepton and dilepton kinematic variables. Complementary measurements of eμbb¯$$e\mu b\bar{b} $$ production, treating both tt¯$$t\bar{t}$$ and Wt events as signal, are also provided. Both sets of differential cross-sections are compared to the predictions of various Monte Carlo event generators, demonstrating that the state-of-the-art generators Powheg MiNNLO and Powhegbb4l describe the data better than Powheghvq.

Aad, G

The three-point energy correlator in the coplanar limit

Energy correlators are a type of observables that measure how energy is distributed across multiple detectors as a function of the angles between pairs of detectors. In this paper, we study the three-point energy correlator (EEEC) at lepton colliders in the three-particle near-to-plane (coplanar) limit. The leading-power contribution in this limit is governed by the three-jet (trijet) configuration. We introduce a new approach by projecting the EEEC onto the volume of the parallelepiped formed by the unit vectors aligned with three detected final-state particles. Analogous to the back-to-back limit of the two-point energy correlator probing the dijet configuration, the small-volume limit of the EEEC probes the trijet configuration. We derive a transverse momentum dependent (TMD) based factorization theorem that captures the soft and collinear logarithms in the coplanar limit, which enables us to achieve the next-to-next-to-next-to-leading logarithm (N 3 LL) resummation. To our knowledge, this is the first N 3 LL result for a trijet event shape. Additionally, we demonstrate that a similar factorization theorem can be applied to the fully differential EEEC in the three-particle coplanar limit, which provides a clean environment for studying different coplanar trijet shapes.

Effective Field Theories of QCD

Quantum imaging with positronium-decay-emitted gamma rays

The use of entangled gamma rays from positronium decay for quantum-enhanced imaging of dense materials is demonstrated. Quantum ghost images, where only one of the entangled 511-keV photons interacts with the object, are obtained for tantalum samples of varying density using a 210-ps time-resolution dual detector system and a Na-22 positron source. An analysis comparing both classical and quantum imaging modalities is employed to isolate true 511-keV events from background noise. Image quality is quantitatively assessed using transmission ratios and the Michelson contrast. Quantum-correlated images are found to exhibit superior (up to approximately 1.7x, from 0.49 to 0.83 in the thickest sample measured) contrast compared to classical methods and align well with theoretical expectations. These results suggest that quantum ghost imaging with positronium-based entangled gamma rays could significantly enhance noninvasive imaging of high-density objects, with potential applications in areas such as cargo inspection and security screening.

36 MATERIALS SCIENCE