Global calibration of terrestrial reference cells and errors involved in using different irradiance monitoring techniques

The feasibility of global calibration of terrestrial reference cells is discussed. A simple, accurate 'secondary' calibration technique based on ratios of test to reference cell currents measured in natural sunlight is described. Different techniques for monitoring incident irradiance during solar cell performance measurements are also examined and assessed, including the techniques of black-body detectors, calibrated reference cells, and the convolution of spectral response with solar irradiance.

Curtis, H. B.↗

Absolute line strengths for carbon and sulfur

Work has been conducted to reduce substantially uncertainties concerning the line strengths for carbon and sulfur. Two or more independent methods were used to measure thermodynamic variables and to calibrate detectors for absolute sensitivity and spectral response. The absolute transition probabilities of 124 visible and infrared lines of C I, S I, and S II were measured in a consistent way.

Miller, M. H.↗

Angular device for optical filters

Device provides a means for precise angular adjustment of optical filters in Raman calibration detector units. Device prevents stray light from entering system and has the capability of repeated alignments to predetermined angles.

Overbay, L. W.↗

Abundance of Fe relative to H at 1.5 solar radii

The abundance of Fe relative to H is obtained by using resonantly scattered intensities of lambda 284 of Fe XV that were measured with OSO-7 and resonantly scattered intensities of L-alpha of H I that were obtained by Gabriel (1971). Because of possible differences in electron densities along lines of sight for these non-simultaneous measurements and in relative calibrations, results are rather uncertain but still indicate that the average Fe abundance relative to H in the corona appears to be at least as large as a recent photospheric abundance. Some limitations in using this method for obtaining abundances are examined for future experiments with simultaneous measurements and well calibrated detectors.

Nakada, M. P.↗

Study of LANDSAT-D thematic mapper performance as applied to hydrocarbon exploration

Analysis of the tapes of the Detroit, Michigan scene, which were received in fully processed format with geometric and radiometric correction, shows evidence of an along line data slip every sixteenth line in TM channel 2. Very large scale products were therefore generated in false color using channels 1, 3, and 4. Subjective evaluation of these enhanced scenes indicates that they are acceptable for interpretation at scales up to 1:50,000 and should be useful for change mapping probably up to 1:24,000 scale. The significant striping visible in water bodies for both the natural color and false color products indicates that the detector calibration is probably performing below the preflight specification. Variance-covariance matrices were computed and principal component analysis were performed for a set of 512 x 512 windows within the Arkansas scene. Initial analysis shows the shortwave infrared channels (TM 5 and 6) are a highly significant data source. The thermal channel (TM 7) shows negative correlation with TM 1 through 4.

Source record↗

Study of LANDSAT-D thematic mapper performance as applied to hydrocarbon exploration

Two fully processed test tapes were enhanced and evaluated at scales up to 1:10,000, using both hardcopy output and interactive screen display. A large scale, the Detroit, Michigan scene shows evidence of an along line data slip every sixteenth line in TM channel 2. Very large scale products generated in false color using channels 1,3, and 4 should be very acceptable for interpretation at scales up to 1:50,000 and useful for change mapping probably up to scale 1:24,000. Striping visible in water bodies for both natural and color products indicates that the detector calibration is probably performing below preflight specification. For a set of 512 x 512 windows within the NE Arkansas scene, the variance-covariance matrices were computed and principal component analyses performed. Initial analysis suggests that the shortwave infrared TM 5 and 6 channels are a highly significant data source. The thermal channel (TM 7) shows negative correlation with TM 1 and 4.

Everett, J. R.↗

JPL airborne instruments activities

Two instruments intended for flight aboard aircraft for research in advanced remote sensing of the earth are under development: the airborne imaging spectrometer (AIS) and the airborne visible-infrared imaging spectrometer (AVIRIS). The AIS utilizes a 32 x 32 element HgCdTe CCD array to gather 10nm spectral data, initially in the 1.2 to 2.4 micron range, with 32 pixels of cross-track spatial data. The instrument acquires 128 channels of spectral data by using a grating spectrometer whose grating is stepped through four positions during a fraction of an IFOV time on the ground. With an IFOV of 2 mrad, the GIFOV at the design altitude of 3 km is 6m. The instrument has several on-board processing capabilities including ax+b corrections for detector calibration, cross-track and down-track pixel summing, spectral band summing, and variable integration time to allow flight at various altitudes and velocities. The AVIRIS uses a proven scanning mechanism to acquire the spatial data in a whisk broom mode. The spectral coverage is from 0.35 to 2.5 microns at bandwidths ranging from 10 to 20 nm.

Vane, G.↗

Optical design of the Diffuse Infrared Background Experiment for NASA's Cosmic Background Explorer

The conceptual design for a ten-band absolute filter photometer (the Diffuse Infrared Background Experiment) to operate at 2 K and measure galactic and extragalactic infrared radiation in the 1 to 300-micron range and polarization in the 1 to 3.5-micron range is presented, as part of the NASA Cosmic Background Explorer. The telescope optical design, a Gregorian design incorporating bafffles and shades to provide high stray-light rejection, is described. Pupil nonuniformity in the detector-assembly optical design has been limited. It is determined that detector sensitiity requirements can be met, and that the problem of radiation-induced responsivity variations can be solved by minimizing detector-assembly size, providing for in situ thermal annealing, and allowing for frequent detector calibration. Limitations on mirror performance are to be met by fabricating mirrors and structure from the same aluminum 6061 ingot.

Miller, M. S.↗

Ionization Chamber Measures Extreme Ultraviolet

Ionization chamber operates in nearly total photon absorption as stable, self-calibrating detector of ionizing extreme ultraviolet radiation. Working gas of instrument is neon; photoionization properties well known and readily applicable to absolute measurements. Designed for measurements of solar ultraviolet flux aboard sounding rocket, instrument used on Earth to measure ultraviolet radiation in vacuum systems. Ionization chamber collects positive neon ions and electrons produced by irradiation of neon gas by ultraviolet photons. Approximately one ion produced by each photon; consequently, photoionization current nearly proportional to photon flux.

Carlson, Robert W.↗

Cryogenic absolute radiometers as laboratory irradiance standards, remote sensing detectors, and pyroheliometers

The dramatic improvement in heat diffusivity of pure Cu at liquid-He temperatures makes possible very important advances in the absolute accuracy, reproducibility, sensitivity, and time constant of cryogenic electrical substitution radiometers (ESRs), relative to conventional ESRs. The design and characterization of a table-top cryogenic ESR now available for detector calibration work to the 0.01-percent level of absolute accuracy under laser illumination is discussed. A sensitive cryogenic ESR recently delivered to the NIST for radiometric calibrations of black bodies is also described, along with the design and testing of a very fast cryogenic ESR developed for NASA remote-sensing studies of the earth's radiation budget.

Foukal, Peter V.↗

Performance characteristics of STIS detectors

We report quantum efficiency measurements of back-illuminated, ion-implanted, laser-annealed charge coupled devices (CCD's) in the wavelength range 13-10,000 A. The equivalent quantum efficiency (EQE = effective photons detected per incident photon) ranges from a minimum of 5 percent as 1216 A to a maximum of 87 percent at 135 A. Using a simple relationship for the charge collection efficiency of the CCD pixels as a function of depth, we present a semi-empirical model with few parameters which reproduces our measurements with a fair degree of accuracy. The advantage of this model is that is can be used to predict CCD QE performance for shallow backside implanted devices without detailed solution of a system of differential equations, as in conventional approaches, and yields a simple analytic form for the charge collection efficiency which is adequate for detector calibration purposes. Making detailed assumptions about the dopant profile, we also solve the carrier density and continuity equations in order to relate our semi-empirical model parameters to surface and bulk device properties. The latter procedure helps to better establish device processing parameters for a given level of CCD QE performance.

Stern, Robert A.↗

Design of Optical/IR Blocking Filters for the Lynx X-Ray Microcalorimeter

The Lynx mission concept, under development ahead of the 2020 Astrophysics Decadal Review, includes the Lynx X-ray Microcalorimeter (LXM) as one of its primary instruments. The LXM uses a microcalorimeter array at the focus of a high-throughput soft x-ray telescope to enable high-resolution nondispersive spectroscopy in the soft x-ray waveband (0.2 to 15 keV) with exquisite angular resolution. Similar to other x-ray microcalorimeters, the LXM uses a set of blocking filters mounted within the dewar that pass the photons of interest (x-rays) while attenuating the out-of-band long-wavelength radiation. Such filters have been successfully used on previous orbital and suborbital instruments; however, the Lynx science objectives, which emphasize observations in the soft x-ray band (<1keV), pose more challenging requirements on the set of LXM blocking filters. We present an introduction to the design of the LXM optical/IR blocking filters and discuss recent advances in filter capability targeted at LXM. In addition, we briefly describe the external filters and the modulated x-ray sources to be used for onboard detector calibration.

Eckart, Megan E.↗

Satellite Calibration With LED Detectors at Mud Lake

Earth-monitoring instruments in orbit must be routinely calibrated in order to accurately analyze the data obtained. By comparing radiometric measurements taken on the ground in conjunction with a satellite overpass, calibration curves are derived for an orbiting instrument. A permanent, automated facility is planned for Mud Lake, Nevada (a large, homogeneous, dry lakebed) for this purpose. Because some orbiting instruments have low resolution (250 meters per pixel), inexpensive radiometers using LEDs as sensors are being developed to array widely over the lakebed. LEDs are ideal because they are inexpensive, reliable, and sense over a narrow bandwidth. By obtaining and averaging widespread data, errors are reduced and long-term surface changes can be more accurately observed.

Hiller, Jonathan D.↗

The development of an electrochemical technique for in situ calibrating of combustible gas detectors

A program to determine the feasibility of performing in situ calibration of combustible gas detectors was successfully completed. Several possible techniques for performing the in situ calibration were proposed. The approach that showed the most promise involved the use of a miniature water vapor electrolysis cell for the generation of hydrogen within the flame arrestor of a combustible gas detector to be used for the purpose of calibrating the combustible gas detectors. A preliminary breadboard of the in situ calibration hardware was designed, fabricated and assembled. The breadboard equipment consisted of a commercially available combustible gas detector, modified to incorporate a water vapor electrolysis cell, and the instrumentation required for controlling the water vapor electrolysis and controlling and calibrating the combustible gas detector. The results showed that operation of the water vapor electrolysis at a given current density for a specific time period resulted in the attainment of a hydrogen concentration plateau within the flame arrestor of the combustible gas detector.

Shumar, J. W.↗

Self-Calibration and Laser Energy Monitor Validations for a Double-Pulsed 2-Micron CO2 Integrated Path Differential Absorption Lidar Application

Double-pulsed 2-micron integrated path differential absorption (IPDA) lidar is well suited for atmospheric CO2 remote sensing. The IPDA lidar technique relies on wavelength differentiation between strong and weak absorbing features of the gas normalized to the transmitted energy. In the double-pulse case, each shot of the transmitter produces two successive laser pulses separated by a short interval. Calibration of the transmitted pulse energies is required for accurate CO2 measurement. Design and calibration of a 2-micron double-pulse laser energy monitor is presented. The design is based on an InGaAs pin quantum detector. A high-speed photo-electromagnetic quantum detector was used for laser-pulse profile verification. Both quantum detectors were calibrated using a reference pyroelectric thermal detector. Calibration included comparing the three detection technologies in the single-pulsed mode, then comparing the quantum detectors in the double-pulsed mode. In addition, a self-calibration feature of the 2-micron IPDA lidar is presented. This feature allows one to monitor the transmitted laser energy, through residual scattering, with a single detection channel. This reduces the CO2 measurement uncertainty. IPDA lidar ground validation for CO2 measurement is presented for both calibrated energy monitor and self-calibration options. The calibrated energy monitor resulted in a lower CO2 measurement bias, while self-calibration resulted in a better CO2 temporal profiling when compared to the in situ sensor.

Refaat, Tamer F.↗

Technology for satellite power conversion

The work is this reporting period was concentrated on electronically calibrating the bolometer detectors. The calibration is necessary for two reasons: first, the power delivered to the rectifying circuit must be known in order to choose a diode with the appropriate barrier height, and second, the power captured by the antenna must be measured if the efficiency of the rectenna is to be divided into antenna efficiency and rectification efficiency. The millimeter wave region operation of the bolometers was simulated with a VHF (10 to 90 MHz) test signal. These detectors are accurate to within roughly 10%. The typical responsivity of the bolometers is 10 volts/watt and the NEP at 20 Hz is 5 times 10 to the minus 9th power W(Hz)-1/2.

Gouker, M. A.↗