Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

JPL Fourier transform ultraviolet spectrometer

The Fourier Transform Ultraviolet Spectrometer (FTUVS) is a new high resolution interferometric spectrometer for multiple-species detection in the UV, visible and near-IR. As an OH sensor, measurements can be carried out by remote sensing (limb emission and column absorption), or in-situ sensing (long-path absorption or laser-induced fluorescence). As a high resolution detector in a high repetition rate (greater than 10 kHz) LIF system, OH fluorescence can be discriminated against non-resonant background emission and laser scatter, permitting (0, 0) excitation.

Cageao, R. P.↗

Resolving the Cygnus X-3 iron K line

An Advanced Satellite for Cosmology and Astrophysics (ASCA) observation of Cygnus X-3 on 1993 June 11, in its X-ray high intensity state, has for the first time resolved the broad iron K line emission into three components: a He-like line at 6.67 +/- 0.01 keV, a H-like line at 6.96 +/- 0.02 keV, and a neutral line at 6.37 +/- 0.03 keV. The line intensities of the 6.67 keV and 6.96 keV lines are modulated with the 4.8 hr orbital period and are maximum when the continuum intensity is minimum. There is a sharp minimum of the line intensity on the rising phase of the continuum intensity. An iron absorption edge is observed at 7.19 +/- 0.02 keV. The optical depth of the absorption edge varies from 0.3 to 0.5 and is in anti-phase with the overall X-ray continuum modulation. The observed complexity of the iron K line region is greater than that had been assumed in previous spectral modeling based on observations with lower resolution detectors.

Kitamoto, Shunji↗

A measurement concept for hot-spot BRDFs from space

Several concepts for canopy hot-spot measurements from space have been investigated. The most promising involves active illumination and bistatic detection that would allow hot-spot angular distribution (BRDF) measurements from space in a search-light mode. The concept includes a pointable illumination source, such as a laser operating at an atmospheric window wavelength, coupled with a number of high spatial-resolution detectors that are clustered around the illumination source in space, receiving photons nearly coaxial with the reto-reflection direction. Microwave control and command among the satellite cluster would allow orienting the direction of the laser beam as well as the focusing detectors simultaneously so that the coupled system can function like a search light with almost unlimited pointing capabilities. The concept is called the Hot-Spot Search-Light (HSSL) satellite. A nominal satellite altitude of 600 km will allow hot-spot BRDF measurements out to about 18 degrees phase angle. The distributed are taking radiometric measurements of the intensity wings of the hot-spot angular distribution without the need for complex imaging detectors. The system can be operated at night for increased signal-to-noise ratio. This way the hot-spot angular signatures can be quantified and parameterized in sufficient detail to extract the biophysical information content of plant architectures.

Reflectivity↗

Shuttle Space Suit: Fabric/LCVG Model Validation

A detailed space suit computational model is being developed at the Langley Research Center for radiation exposure evaluation studies. The details of the construction of the space suit are critical to estimation of exposures and assessing the risk to the astronaut on EVA. Past evaluations of space suit shielding properties assumed the basic fabric layup (Thermal Micrometeoroid Garment, fabric restraints, and pressure envelope) and LCVG could be homogenized as a single layer overestimating the protective properties over 60 percent of the fabric area. The present space suit model represents the inhomogeneous distributions of LCVG materials (mainly the water filled cooling tubes). An experimental test is performed using a 34-MeV proton beam and high-resolution detectors to compare with model-predicted transmission factors. Some suggestions are made on possible improved construction methods to improve the space suit s protection properties.

Wilson, J. W.↗

Shuttle Spacesuit: Fabric/LCVG Model Validation

A detailed spacesuit computational model is being developed at the Langley Research Center for radiation exposure evaluation studies. The details of the construction of the spacesuit are critical to estimation of exposures and assessing the risk to the astronaut on EVA. Past evaluations of spacesuit shielding properties assumed the basic fabric lay-up (Thermal Micrometeroid Garment, fabric restraints, and pressure envelope) and Liquid Cooling and Ventilation Garment (LCVG) could be homogenized as a single layer overestimating the protective properties over 60 percent of the fabric area. The present spacesuit model represents the inhomogeneous distributions of LCVG materials (mainly the water filled cooling tubes). An experimental test is performed using a 34-MeV proton beam and high- resolution detectors to compare with model-predicted transmission factors. Some suggestions are made on possible improved construction methods to improve the spacesuit's protection properties.

Wilson, J. W.↗

Expected Performance of the GLAST Burst Monitor

The GLAST Burst Monitor (GBM) will enhance LAT observations of GRBs by extending the spectral coverage from the LAT threshold down to approx. 8 kev, and will provide a trigger for re-orienting the spacecraft to observe delayed emission from selected bursts outside the LAT field of view. GBM consists of twelve NaI scintillation detectors operating in the 8 kev to 1 MeV energy range and two BGO scintillation detectors operating in the 150 keV to 30 MeV energy range. Detector resolution, effective area, and angular response have been determined by calibrations. Analyses indicate that the on-board burst threshold will be approx. 0.7 photon/cm2/s and the on-board burst localization accuracy will typically be better than 8 degrees.

Meegan, Charles↗

Isosceles detector provides maximum resolution in expanded range

Dynamic range expansion system for radio frequency /RF/ signal detection equipment consists of RF amplifiers, RF amplitude modulated detectors, and operational amplifier. The analog output gives maximum resolution over fixed voltage range, without switching. Two minor drawbacks of this circuit are cited.

Watterson, R. F.↗

Thermal detectors for high resolution spectroscopy

Cryogenic microcalorimeters can be made sensitive enough to measure the energy deposited by a single particle or X-ray photon with an accuracy of about one electron volt. It may also be possible to construct detectors of several-kilograms mass whose resolution is only a few times worse than this. Data from relatively crude test devices are in good agreement with thermal performance calculations, and a total system noise of 11 eV FWHM has been obtained for a silicon detector operating at 98 mK. Observations of 35 eV FWHM for 6-keV X-rays with a different device have been made.

Mccammon, D.↗

Rocket-borne instrument with a high-resolution microchannel plate detector for planetary UV spectroscopy

A telescope-spectrograph employing a photon-counting microchannel plate (MCP)-CODACON detector has been built, tested, and flown on a sounding rocket. The detector uses a curved-channel MCP proximity focused onto a coded anode array of 1024 channels spaced 25.4-mm center to center. High quantum efficiency is obtained by depositing a cesium iodide photocathode on the front surface of the MCP. The instrument has obtained an ultraviolet spectrum of Jupiter with a spectral resolution of 8 A, which is higher than that of any previously reported observation in this wavelength range.

Mcclintock, W. E.↗

Mercuric iodine room temperature gamma-ray detectors

high resolution mercuric iodide room temperature gamma-ray detectors have excellent potential as an essential component of space instruments to be used for high energy astrophysics. Mercuric iodide detectors are being developed both as photodetectors used in combination with scintillation crystals to detect gamma-rays, and as direct gamma-ray detectors. These detectors are highly radiation damage resistant. The list of applications includes gamma-ray burst detection, gamma-ray line astronomy, solar flare studies, and elemental analysis.

Patt, Bradley E.↗

High-resolution imaging X-ray detector

The paper describes an X-ray detector using microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. The position resolution is 10 microns. The crossed wire grid consists of 100-micron-diam wires on 200-micron centers. Position sensing is accomplished by electronic interpolation to 1/20 of the wire spacing. The quantum efficiency of the microchannel plates varies from 29% at 0.28 keV to 5% at 3 keV. This detector will provide second-of-arc X-ray imaging in the focal plane of the 342.9-cm focal length grazing-incidence telescope being prepared for the HEAO-B observatory. By addition of suitable photocathodes, it can be used for single-photon imaging light detection in the UV, visible, and near-IR-ranges. In all cases, it gives a very low dark counting rate, allows timing of individual events to 1 microsec or less, and can handle counting rates up to 10,000 per sec.

Kellogg, E.↗

The X-ray Spectrometer - A cryogenic instrument on the Advanced X-ray Astrophysics Facility

The X-ray Spectrometer (XRS) is an instrument on the Advanced X-ray Astrophysics Facility (AXAF), the third of NASA's Great Observatories scheduled for launch in 1998. The XRS detectors have a resolution of approximately 10 eV over the range 0.3 - 10 keV. To achieve this resolution, the detectors are maintained at or below 0.1 Kelvin using an adiabatic demagnetization refrigerator inside a superfluid helium dewar. In addition, split-Stirling-cycle mechanical coolers are used to extend the anticipated on-orbit helium lifetime to a minimum of 4 years. This paper describes the challenges of developing this hybrid cryogenic system and presents an overview of the current design of the system.

Breon, Susan R.↗

Large-format high resolution microchannel plate detectors for ultraviolet astronomy

This report includes work on two types of two-dimensional position-sensitive detectors that were developed in this lab under this award. We worked to develop and optimize the wire-wound helical delay line detector (HDL) in the first and second years. Some early work on the HDL is contained in a paper included as Appendix A. In the second and third years we developed the concept for, then successfully designed and tested, both a lab prototype, and a flight prototype of the first, crossed delay line detector based on two orthogonal serpentine delay lines (SDL). Some of the work on the SDL is contained in a paper included as Appendix B. Appendix C contains copies of the invention report and record.

Martin, Christopher↗

Investigating the Spatial and Temporal Limitations for Remote Sensing of Wildfire Smoke Using Satellite and Airborne Imagers During FIREX_AQ

Starting from point sources, wildfire smoke is important in the global aerosol system. The ability to characterize smoke near-source is key to modeling smoke dispersion and predicting air quality. With hemispheric views and 10-min refresh, imagers in Geostationary (GEO) orbit have advantages monitoring smoke over once-per-day sensors in low-earth orbit (LEO). However, both can be inadequate in capturing the characteristics of smoke plumes close to their sources due to too-coarse spatial resolution (both detector and product resolution), too-sparse temporal resolution (from LEO sensors), and too-conservative masking. In addition to satellite observations, the Fire Influence on Regional to Global Environments and Air Quality experiment offered sub-orbital enhanced-MODIS Airborne Simulator (eMAS) imagery at 50 m pixel resolution—including multiple eMAS flight tracks over individual fires in short time periods. It provided opportunity to explore smoke plume characterization at various spatial and temporal scales and quantify the limitations of space sensors for describing smoke magnitude near source as well as its temporal evolution. Here we applied modified aerosol algorithm to different imagers, relaxing its masking to estimate smoke's aerosol optical depth (AOD) as close as possible to its source. We found that GEO sensors with nominal 1 km spatial resolution can match the much finer resolution eMAS retrieved mean plume AOD, as long as the retrieval spatial resolution is finer than the width of the plumes. However, the plume's maximum AOD may be drastically underestimated by satellite products.

remote sensing↗

High resolution Cerenkov and range detectors for balloon-borne cosmic-ray experiment

A combination of an active Cerenkov detector and passive range detectors is proposed for the high resolution measurement of isotopic composition in the neighborhood of iron in the galactic cosmic rays. A large area (4,300 sq cm) Cerenkov counter and passive range detectors were tested. Tests with heavy ions (2.1 GeV/amu C-12, 289 MeV/amu Ar-40, and 594 MeV/amu Ne-20) revealed the spatial uniformity of response of the Cerenkov counter to be better than 1% peak-to-peak. Light collection efficiency is independent of projectile energy and incidence angle to within at least 0.5%. Passive Lexan track recorders to measure range in the presence of the nuclear interaction background which results from stopping particles through 0.9 interaction lengths of matter were also tested. It was found that nuclear interactions produce an effective range straggling distribution only approximately 75% wider than that expected from range straggling alone. The combination of these tested techniques makes possible high mass resolution in the neighborhood of iron.

Ahlen, S. P.↗