Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Software Development for Data Visualization and Analysis of PN-Diodes & MOSFET Devices

The U.S. Department of Energy has a broad mission to ensure the nation’s security by addressing ongoing environmental challenges, developing novel energy production technologies, and mitigating nuclear security concerns. These efforts benefit from developing more effective semiconductor materials and devices. The research discussed in this report aims to further the development of these new electronics by improving implementations of vertical device structures, which offer theoretically better performance compared to lateral structures. Specifically, it reviews the background and development of a new and easy-to-use program for data processing and analysis from experiments run on vertical gallium nitride power devices. Current vertical structures fall short in critical performance metrics, such as On-Resistance and Breakdown Voltage, due to poor management of the device’s electric field. Junction termination extensions, or JTEs, are a field management technique that increases a device’s resilience to expected failure modes by controlling its surface electric fields. Each JTE design requires significant experimental validation, consisting of hundreds of tested devices, each outputting an enormous set of data points. The new software includes multiple methods of filtering large sets of device testing data to identify and remove flawed devices, automate device analyses, and provide statistical breakdowns for four metrics used to define the effectiveness of the JTE and the current carrying capacity of the device. These results can then be related back to fabrication techniques and device design, and in the future, be combined with processing simulations to further improve our understanding of the JTE mechanisms.

97 MATHEMATICS AND COMPUTING↗

Operation Castle

On February 28, 1954, Bravo, the first of six thermonuclear devices tested during Operation Castle, burst into the sky over Bikini Atoll. 1 In an instant, and unexpectedly, Bravo became the highest yield device tested by the United States. Romeo, Koon, Union, Yankee, and Nectar followed. Each, with the exception of Koon, performed better than predicted, providing the United States with stable, deliverable thermonuclear weapons, albeit ones still very large and cumbersome. 2 The overall success of Castle, however, had a downside. Bravo’s fallout injured Marshallese natives and contaminated a Japanese fishing trawler. The international uproar that followed ultimately led to the cessation of atmospheric testing.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Device, system, and method for measuring internal impedance of a test battery using frequency response

Battery impedance testing devices, circuits, systems, and related methods are disclosed. An impedance measurement device includes a current driver configured to generate an excitation current signal to be applied to a test battery responsive to a control signal, and a processor operably coupled with the current driver. The processor is configured to generate the control signal during an auto-ranging mode and a measuring mode. The auto-ranging mode applies the excitation current signal to the test battery over a plurality of different amplitudes to measure a response to the excitation current signal at each amplitude. The measuring mode applies the excitation current signal to the test battery for an amplitude responsive to the results of the auto-ranging mode. Improved sensitivity and resolution may be achieved for low impedance batteries with a rapid measurement time.

25 ENERGY STORAGE↗

In Situ ATR-FTIR Study of the Cathode–Electrolyte Interphase: Electrolyte Solution Structure, Transition Metal Redox, and Surface Layer Evolution

We present a study of the lithium nickel manganese cobalt oxide (LiNi 0.6 Mn 0.2 Co 0.2 O 2 , NMC622) cathode-electrolyte interphase (CEI) during galvanostatic charging and discharging using in situ attenuated total reflectance Fourier transform infrared (ATR-FTIR) methods to investigate the voltage dependent electrolyte solution structure changes at the interface, transition metal (TM) redox chemistry, and cathode/electrolyte interfacial layer evolution. Furthermore, our in situ cell design provides both reliable electrochemical device testing and strong FTIR vibrational absorption signals near the cathode surface. Specifically, advanced spectral analysis elucidates changes of near-surface Li+ ion (de)solvation by solvent molecules during galvanostatic cycling. Moreover, cathode metal-oxygen vibrational absorptions, sensitive to TM redox behaviors and subsequent local structural variations, were correlated to cathode de-lithiation (and lithiation) and electrolyte solution structure changes. In addition, we have detected the formation and evolution of a CEI surface layer on the NMC622 cathode that contributes to the cell's capacity fade.

25 ENERGY STORAGE↗

Rapid microwave synthesis of indium filled skutterudites: An energy efficient route to high performance thermoelectric materials

Graphical abstract: Filled skutterudites are promising thermoelectric materials. We report the microwave assisted synthesis of CoSb{sub 3} and In{sub 0.2}Co{sub 4}Sb{sub 12}. This method reduces the calcination time for skutterudite phase formation from 2 days to 2 min, thereby significantly reducing the time and energy needed to produce materials suitable for property and device testing. Highlights: Black-Right-Pointing-Pointer The microwave assisted solid state synthesis of CoSb{sub 3} and In{sub 0.2}Co{sub 4}Sb{sub 12} is reported. Black-Right-Pointing-Pointer This method allows the calcination time to be reduced from 2 days to 2 min. Black-Right-Pointing-Pointer Physical properties of microwave samples match those prepared conventionally. -- Abstract: Filled skutterudites are promising thermoelectric materials due to reduced thermal conductivity upon inserting a guest atom or 'rattler' into the CoSb{sub 3} structure. By using an indium rattler dimensionless Figure of Merit (ZT) values >1 at 650 K have been reported. The conventional synthesis of these compounds typically takes several days ({approx}3 days) to obtain the final well-sintered material for property measurements. We report here a microwave-assisted synthesis method that reduces the initial calcination time from 2 days to 2 min. This route significantly reduces the time needed to produce materials suitable for property and device testing.

36 MATERIALS SCIENCE↗

Characterization of the Hamamatsu VUV4 MPPCs for nEXO

In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range 163 K = T = 233 K. At an over voltage of 3.1 ± 0.2 V and at T = 163 K we report a number of Correlated Avalanches (CAs) per pulse in the 1µs interval following the trigger pulse of 0.161±0.005. At the same settings the Dark-Noise (DN) rate is 0.137 ± 0.002 Hz/mm2. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at T = 233 K for a mean wavelength of 189 ± 7 nm. At 3.6 ± 0.2 V and 3.5 ± 0.2 V of over voltage we report a PDE of 13.4 ± 2.6 % and 11 ± 2%, corresponding to a saturation PDE of 14.8 ± 2.8 % and 12.2±2.3%, respectively. Both values are well below the 24 % saturation PDE advertised by Hamamatsu. More generally, the second device tested at 3.5 ± 0.2 V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBKLF SiPMs for the final design of the nEXO detector.

Gallina, G↗

Cooling for SC devices of test cryomodule for ADS Injector II at IMP

The superconducting half-wave resonance cavities connected in series with superconducting solenoids will be applied to the Injector II of the Accelerator Driven Sub-critical System (ADS) to be built at the Modern Physics Institute, China. A test system has been developed for the purpose of performance test of the HWR cavities as well as validating the relevant technique for cooling the cavity and the solenoids together. It mainly comprises a cryogenic valve box (TVB), a test cryomodule (TCM1) and transfer lines. The TCM1 includes one HWR cavity, two superconducting solenoids, one cold BPM and their cooling system. The design of the TCM1 cryostat was carried out by the Shanghai Institute of Applied Physics (SINAP), CAS. Both the cavity and the solenoids will work at 4.4 K by bath cooling. The fast cooling down for the cavity from around 100 K to 120 K is required to avoid degrading of the cavity performance. After cool down and before energization, the solenoids should be warmed up to above 10 K and re-cooled down for the purpose of degaussing. The TCM1 can not only be cooled by using the dewar-filling system, but also operated by the refrigerator system. For the purpose of reducing the heat loads to the cold mass at 4 K from room temperature, thermal radiation shields cooled by liquid nitrogen flowing in tubing were employed. This paper presents the design details of cooling circuits and thermal shields of the TCM1 as well as related calculations and analyses.

43 PARTICLE ACCELERATORS↗

Testbeds for test Readiness: Strategic Snapshot

Test bed engineering, monitoring for underground explosive and nuclear testing will be needed if the United States returns to a test posture of nuclear device testing. To maintain and rebuild the capability of test readiness, agile cost-effective test beds are needed and LANL as well as NNSS are the perfect locations to do this. Shallow and deep boreholes should be created to research containment science, diagnostic placement and optimization, coupling and emplacement science, tracer use for fracture and cratering research, and validation of test article performance.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

AREVA NP MR Cladding benefits for proposed US NRC RIA and LOCA requirements

M5 is the reference alloy of AREVA NP for PWR cladding applications. It is a zirconium-based alloy containing 1% niobium, no tin, and well-controlled oxygen, iron, and sulfur contents. It has a fully recrystallized microstructure. The absence of tin in M5 results in a very low corrosion rate and hydrogen pick-up during normal operation, even at high burn-up and in high duty irradiation conditions. Due to this low hydrogen pick-up under irradiation (typically less than 100 ppm, End of Life), M5 retains a very good strength and an exceptional residual ductility during and after the accident. This allows utilities implementing M5 to simplify the safety analysis and to demonstrate significant margins regarding fuel related criteria. Simplified methods are easier for plants to implement and maintain for future plant operations and core design management. This paper specifically presents 3 examples on the safety improvement brought by M5 cladding. First, during a reactivity-induced accident (RIA), the properties of M5 are such that bounding analyses for future cycles are significantly simplified, in particular by demonstrating that fuel dispersal will not occur. The major aspects of the AREVA NP RIA methodology are presented. A second focus is made on the low hydrogen embrittlement of M5 and on its high ductility after quenching during a loss-of-coolant accident (LOCA). In a third part, the breakaway oxidation testing program currently under development in Paimboeuf (France) is described, including details about the testing devices and qualification. The tests have demonstrated that M5 cladding does not have breakaway at least up to 5000 s oxidation duration at 1000 C. degrees, which is much higher than the LOCA duration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Aquantis 2.5 MW Ocean Current Generation Device - Scaled Tank Test Design and Results

Aquantis 2.5 MW Ocean Current Generation Device, Tow Tank Dynamic Rig Structural Analysis Results. This is the detailed documentation for scaled device testing in a tow tank, including models, drawings, presentations, cost of energy analysis, and structural analysis. This dataset also includes specific information on drivetrain, roller bearing, blade fabrication, mooring, and rotor characteristics.

16 TIDAL AND WAVE POWER↗

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects↗

SU-F-T-11: Scintillator Based Quality Assurance Device for HDR Brachytherapy

Purpose: To build a test device for HDR afterloaders capable of checking source positions, times at positions and estimate the activity of the source. Methods: A catheter is taped on a plastic scintillation sheet. When a source travels through the catheter, the scintillator sheet lights up around the source. The sheet is monitored with a video camera, and records the movement of the light spot. The center of the spot on each image on the video provides the source location, and the time stamps of the images can provide the dwell time the source spend in each location. Finally, the brightness of the light spot is related to the activity of the source. A code was developed for noise removal, calibrate the scale of the image to centimeters, eliminate the distortion caused by the oblique view angle, identifying the boundaries of the light spot, transforming the image into binary and detect and calculate the source motion, positions and times. The images are much less noisy if the camera is shielded. That requires that the light spot is monitored in a mirror, rather than directly. The whole assembly is covered from external light and has a size of approximately 17×35×25cm (H×L×W) Results: A cheap camera in BW mode proved to be sufficient with a plastic scintillator sheet. The best images were resulted by a 3mm thick sheet with ZnS:Ag surface coating. The shielding of the camera decreased the noise, but could not eliminate it. A test run even in noisy condition resulted in approximately 1 mm and 1 sec difference from the planned positions and dwell times. Activity tests are in progress. Conclusion: The proposed method is feasible. It might simplify the monthly QA process of HDR Brachytherapy units.

07 ISOTOPE AND RADIATION SOURCES↗

Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects

Purpose: The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Methods: Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ/i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. Results: The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm{sup -1}) and approximate circular symmetry at frequencies below 4 mm{sup -1}. While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm{sup -1}. Slit measurement near 45 Degree-Sign revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm Multiplication-Sign 0.2 mm), a characteristic which was not necessarily appreciated with the orthogonal 1D MTF measurements. In simulation experiments, both slit- and edge-based measurements resolved the radial asymmetries in the 2D MTF. The average absolute relative accuracy error in the 2D MTF between the DC and cutoff (2.5 mm{sup -1}) frequencies was 0.13% with average relative precision error of 0.11%. Other simulation results were similar to those derived from physical data. Conclusions: Overall, the general availability, acceptance, accuracy, and ease of implementation of 1D test devices for MTF assessment make this a valuable technique for 2D MTF estimation.

60 APPLIED LIFE SCIENCES↗

Large area vertical Ga 2 O 3 Schottky diodes for X-ray detection

In this work, the Schottky barrier diodes were fabricated from a bulk Sn-doped (001) n-type Ga 2 O 3 substrate with a Si-doped epitaxial layer grown by hydride vapor phase epitaxy (HVPE), which demonstrate a good response to X-rays. Circular metal contacts with diameters ranging from 50 to 1500 um and square metal contacts ranging from 100 X 100 to 1600 X 1600 um 2 were deposited on the wafer. The devices were characterized for their electrical performance including forward current–voltage (FIV), reverse current–voltage (RIV), and capacitance-voltage (CV) measurements. The best device showed a breakdown voltage of –804 V and the devices tested had an average ideality of 1.12. The devices exhibited a clear response to X-rays even at zero bias with an experimentally observed response time 1.03 s and a linear response of detector signal to the X-ray dose rate. The experimentally observed device response time improved to 0.25 s when bias voltage is applied. The device also survived a long-term stability test of over 2 h under a constant X-ray irradiation. The sensitivity and the lower limit of detection for X-ray by Ga2O3 epitaxial Schottky detectors were discussed and determined as 43.5 C/mGy cm –2 at –200 V and 8.31 nGy Air /s, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of performance metrics for the Wave Energy Prize converters tested at 1/20 th scale

It is expected that wave energy technologies will play a future role in providing clean renewable energy and diversifying energy portfolios; however, they are still at an early stage of development compared to other renewables, with varying archetypes proposed. As technologies advance toward commercialization, benchmarking is needed to quantify performance and costs. In this review, experimental datasets of Wave Energy Converter (WEC) devices tested in the final stage of the Wave Energy Prize (WEPrize) are compared and ranked using performance metrics found in the literature and those developed as WEPrize judging metrics at both U.S. and European representative wave climates. Because the WEPrize devices were tested under a set of identical sea states, which ranged from typical operating conditions to extreme storm events, consistent datasets were produced to facilitate comparison. This allows for a rare addition to the open literature on device performance trends. In addition, a reevaluation of trends established in previous power performance benchmarking studies is given. Trends found in previous studies were confirmed, except for the absorbed energy per characteristic mass metric, in which some of the WEPrize devices had higher values. Each of the metrics considered in this study has limitations due to the assumptions in simplifying the economic potential (e.g., power absorbed vs. a proxy to cost). In addition, each of these proxies is limited to the capital cost of a device, unlike the final metric used in the WEPrize, HPQ, which includes limited proxies of operational and capital expenditures, as well as array considerations. Recommendations are given for the use and potential modification of the metrics considered. Specifically, it is recommended that the ACE metric (from the WEPrize) be modified to more accurately include the other important system costs, such as the PTO and mooring, as well as installation, operation and maintenance costs.

16 TIDAL AND WAVE POWER↗

TEAMER: Twin Ocean Power Wave Energy Converter Comprehensive Overview

These files collectively provide a comprehensive overview of the testing process, data analysis, and validation for the Twin Ocean Power device tested at the O.H. Hinsdale Wave Research Laboratory, supported by TEAMER funding. This resource includes an overview of power results for a series of 7 trials. The files included in this comprehensive overview include a comprehensive log sheet for each trial, a summary of all trials, and processing scripts for the raw data. It includes all raw data in .tsv and MATLAB compatible formats, an average power chart, angular velocity charts for each trial, trial metrics, and power output files. This resource includes images of the Twin Ocean Power Wave Energy Converter device components and movement during testing and video recordings of each trial.

16 TIDAL AND WAVE POWER↗

Energy Storage/Conservation and Carbon Emissions Reduction Demonstration Project

The U.S. Department of Energy (DOE) awarded the Center for Transportation and the Environment (CTE) federal assistance for the management of a project to develop and test a prototype flywheel-based energy recovery and storage system in partnership with Test Devices, Inc. (TDI). TDI specializes in the testing of jet engine and power generation turbines, which uses a great deal of electrical power for long periods of time. In fact, in 2007, the company consumed 3,498,500 kW-­hr of electricity in their operations, which is equivalent to the electricity of 328 households. For this project, CTE and TDI developed and tested a prototype flywheel-based energy recovery and storage system. This technology is being developed at TDI’s facilities to capture and reuse the energy necessary for the company’s core process. The new technology and equipment is expected to save approximately 80% of the energy used in the TDI process, reducing total annual consumption of power by approximately 60%, saving approximately two million kilowatt-hours annually. Additionally, the energy recycling system will allow TDI and other end users to lower their peak power demand and reduce associated utility demand charges. The use of flywheels in this application is novel and requires significant development work from TDI. Flywheels combine low maintenance costs with very high cycle life with little to no degradation over time, resulting in lifetimes measured in decades. All of these features make flywheels a very attractive option compared to other forms of energy storage, including batteries. Development and deployment of this energy recycling technology will reduce energy consumption during jet engine and stationary turbine development. By reengineering the current inefficient testing process, TDI will reduce risk and time to market of efficiency upgrades of gas turbines across the entire spectrum of applications. Once in place the results from this program will also help other US industries to utilize energy recycling technology to lower domestic energy use and see higher net energy efficiency. The prototype system and results will be used to seek additional resources to carry out full deployment of a system. Ultimately, this innovative technology is expected to be transferable to other testing applications involving energy-based cycling within the company as well as throughout the industry.

25 ENERGY STORAGE↗