Search NASA⌕ Search

SEARCH · Search NASA

Results for “differential absorption lidar”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Pressure Measurements Using an Airborne Differential Absorption Lidar: Analysis of the Systematic Error Sources - Part 1

Remote airborne measurements of the vertical and horizontal structure of the atmospheric pressure field in the lower troposphere are made with an oxygen differential absorption lidar (DIAL). A detailed analysis of this measurement technique is provided which includes corrections for imprecise knowledge of the detector background level, the oxygen absorption fine parameters, and variations in the laser output energy. In addition, we analyze other possible sources of systematic errors including spectral effects related to aerosol and molecular scattering interference by rotational Raman scattering and interference by isotopic oxygen fines.

Flamant, Cyrille N.↗

Spectral control of an alexandrite laser for an airborne water-vapor differential absorption lidar system

A narrow-linewidth pulsed alexandrite laser has been greatly modified for improved spectral stability in an aircraft environment, and its operation has been evaluated in the laboratory for making water-vapor differential absorption lidar measurements. An alignment technique is described to achieve the optimum free spectral range ratio for the two etalons inserted in the alexandrite laser cavity, and the sensitivity of this ratio is analyzed. This technique drastically decreases the occurrence of mode hopping, which is commonly observed in a tunable, two-intracavity-etalon laser system. High spectral purity (greater than 99.85%) at 730 nm is demonstrated by the use of a water-vapor absorption line as a notch filter. The effective cross sections of 760-nm oxygen and 730-nm water-vapor absorption lines are measured at different pressures by using this laser, which has a finite linewidth of 0.02 cm(exp -1) (FWHM). It is found that for water-vapor absorption linewidths greater than 0.04 cm(exp -1) (HWHM), or for altitudes below 10 km, the laser line can be considered monochromatic because the measured effective absorption cross section is within 1% of the calculated monochromatic cross section. An analysis of the environmental sensitivity of the two intracavity etalons is presented, and a closed-loop computer control for active stabilization of the two intracavity etalons in the alexandrite laser is described. Using a water-vapor absorption line as a wavelength reference, we measure a long-term frequency drift (approximately 1.5 h) of less than 0.7 pm in the laboratory.

Ponsardin, Patrick↗

Micropulse Differential Absorption Lidar (MPD) Network Demonstration Field Campaign Report

The National Center for Atmospheric Research (NCAR) and Montana State University (MSU) are nearing completion of a National Science Foundation (NSF) major research instrumentation grant to build five micropulse differential absorption lidars (MPDs) for water vapor profiling. The first demonstration of the MPD configured as a five-unit network occurred at the Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) field sites near Lamont, Oklahoma from 17 April–21 July 2019 for a total of 96 days of operation. The field deployment was funded in part by DOE (which provided support for the MPD installation, power at the field sites, personnel to launch 3-hourly radiosondes from the Central Facility, and the cost of the radiosondes themselves), internal NCAR funds (to support the MPD shipping costs and NCAR staff travel expenses), and NSF/Major Research Instrumentation (MRI) funds (to support the MSU travel expenses to participate in the instrument setup).

54 ENVIRONMENTAL SCIENCES↗

Triple-Pulsed Two-Micron Integrated Path Differential Absorption Lidar: A New Active Remote Sensing Capability with Path to Space

The two-micron wavelength is suitable for monitoring atmospheric water vapor and carbon dioxide, the two most dominant greenhouse gases. Recent advances in 2-micron laser technology paved the way for constructing state-of-the-art lidar transmitters for active remote sensing applications. In this paper, a new triple-pulsed 2-micron integrated path differential absorption lidar is presented. This lidar is capable of measuring either two species or single specie with two different weighting functions, simultaneously and independently. Development of this instrument is conducted at NASA Langley Research Center. Instrument scaling for projected future space missions will be discussed.

Singh, Upendra N.↗

Differential absorption lidar systems for tropospheric and stratospheric ozone measurements

A lidar facility has been established at the Jet Propulsion Laboratory-Table Mountain Facility located at an altitude of 2300 m in the San Gabriel Mountains in Southern California. This facility is using the technique of differential absorption lidar to measure atmospheric ozone concentration profiles. Two separate systems are needed to obtain the profile from the ground up to an altitude of 45 to 50 km. An Nd:YAG-based system is described for measurements from the ground up to 15 to 20 km altitude, and an excimer-laser-based system for measurements from 15 km to 45 to 50 km altitude. The systems were designed to make high-precision, long-term measurements to aid in the detection of changes in the atmospheric ozone abundance through participation in the Network of Detection of Stratospheric Change.

Mcdermid, I. Stuart↗

A Ground-Based Profiling Differential Absorption LIDAR System for Measuring CO2 in the Planetary Boundary Layer

Ground-based LIDAR observations can potentially provide continuous profiles of CO2 through the planetary boundary layer and into the free troposphere. We will present initial atmospheric measurements from a prototype system that is based on components developed by the telecommunications industry. Preliminary measurements and instrument performance calculations indicate that an optimized differential absorption LIDAR (DIAL) system will be capable of providing continuous hourly averaged profiles with 250m vertical resolution and better than 1 ppm precision at 1 km. Precision increases (decreases) at lower (higher) altitudes and is directly proportional to altitude resolution and acquisition time. Thus, precision can be improved if temporal or vertical resolution is sacrificed. Our approach measures absorption by CO2 of pulsed laser light at 1.6 microns backscattered from atmospheric aerosols. Aerosol concentrations in the planetary boundary layer are relatively high and are expected to provide adequate signal returns for the desired resolution. The long-term goal of the project is to develop a rugged, autonomous system using only commercially available components that can be replicated inexpensively for deployment in a monitoring network.

Andrews, Arlyn E.↗

Temperature sensitivity of differential absorption lidar measurements of water vapor in the 720-nm region

Recently measured properties of water vapor (H2O) absorption lines have been used in calculations to evalute the temperature sensitivity of differential absorption lidar (Dial) H2O measurements. This paper estimates the temperature sensitivity of H2O lines in the 717-733-nm region for both H2O mixing ratio and number density measurements, and discusses the influence of the H2O line ground state energies E-double-prime, the H2O absorption linewidths, the linewidth temperature dependence parameter, and the atmospheric temperature and pressure variations with altitude and location on the temperature sensitivity calculations. Line parameters and temperature sensitivity calculations for 67 H2O lines in the 720-nm band are given which can be directly used in field experiments. Water vapor lines with E-double-prime values in the 100-300/cm range were found to be optimum for Dial measurements of H2O number densities, while E-double-prime values in the 250-500/cm range were found to be optimum for H2O mixing ratio measurements.

Browell, Edward V.↗

Airborne Demonstration of Atmospheric Oxygen Optical Depth Measurements with an Integrated Path Differential Absorption Lidar

We report on an airborne demonstration of atmospheric oxygen (O2) optical depth measurements with an Integrated Path Differential Absorption (IPDA) lidar using a fiber-based laser transmitter and photon counting detectors. Accurate atmospheric temperature and pressure measurements are needed for NASA's Active Sensing of CO2 Emissions over Nights, Days and Seasons (ASCENDS) mission. Since O2 is uniformly mixed in the atmosphere, its spectrum can be used to estimate the dry mixing ratio of CO2. In its airborne configuration, the IPDA lidar uses an Erbium Doped Fiber amplifier, a frequency doubler and single photon counting detectors to measure O2 absorption at multiple wavelengths near 765 nm. This instrument was deployed in 2013 and 2014 aboard NASA's DC-8 airborne laboratory as part of two campaigns to measure CO2 mixing ratios over a wide range of topography and weather conditions from altitudes ranging between 3 km and 13 km. In this paper we will review a summary of the results from our flights, discuss the errors that limit the precision and accuracy of the measurement and identify possible areas of improvement.

Methane↗

Differential absorption lidar (DIAL) for water vapor and aerosol profiling from airborne and space-based platforms

Many current challenges in weather and climate prediction involve cloud and aerosol processes, which are intimately linked to processes that initiate or take place within the planetary boundary layer (PBL). The current space-based observing system provides a wealth of information on the spatial distribution of key atmospheric variables such as profiles of water vapor (WV) and temperature, but lacks the sensitivity, accuracy, and vertical resolution in the PBL to overcome the observational gaps that inhibit the parametrization and advancement of current climate and weather models. To overcome some of these observational gaps and improve understanding and monitoring of these key processes, mature remote sensing techniques like Differential Absorption Lidar (DIAL) can be employed from various platforms to capture processes on a wide range of spatial scales. This presentation will provide an overview of NASA’s water vapor DIAL capabilities, present the strengths, weaknesses, and synergies of the DIAL technique relative to traditional methods, and provide representative data examples from the HALO airborne water vapor DIAL which was designed as a technology testbed for future space-based DIAL missions as well as a workhorse instrument in support of suborbital process studies. HALO is an airborne multifunction lidar system, simultaneously profiling WV with the DIAL technique and aerosol and cloud optical properties and PBL heights via the high spectral resolution lidar (HSRL) technique. HALO has a compact design that allows it to fly on most research aircraft, enabling nadir profiling from the lower stratosphere down through the PBL, which is critical for studying processes such as convection and cloud formation that can link the PBL and free troposphere. We will end with an outlook on the benefits and challenges of transitioning the mature DIAL technique to space to compliment other active and passive sounders and enable new PBL observations for the future Earth Observing System. The Atmospheric Boundary layer Lidar pathfindEr (ABLE), a program aimed at advancing technologies to enable the first demonstration of DIAL from space with cross-cutting observables of PBL heights, aerosol and cloud profiling, and methane columns from space will also be presented.

Brian J. Carroll↗

Differential Absorption Lidar for Searching Water Sources on Mars

Water vapor has been detected in the Martian atmosphere by multiple orbiting instruments. The Atmospheric Chemistry Suite (ACS) on the ExoMars Trace Gas Orbiter (TGO) observed H2O mixing ratios reaching up to 50 ppmv at altitudes of 100-120 km during global dust storms, while levels remained low (<2 ppmv) during other seasons. The Neutral Gas and Ion Mass Spectrometer (NGIMS) on the Mars Atmosphere and Volatile EvolutioN (MAVEN) spacecraft revealed that water transported to the upper atmosphere is dissociated by ions, producing atomic hydrogen that escapes into space, contributing to Mars’ water loss. This transport is seasonal, peaking in southern summer and intensifying during dust storms. Additionally, the Mars Reconnaissance Orbiter’s (MRO) imaging spectrometer detected hydrated minerals on slopes, suggesting that liquid water may intermittently flow on present-day Mars. However, an observational gap exists between high-altitude water vapor and surface water due to limitations in spatial resolution and a lack of measurements in the lower atmosphere. To address this gap, we propose using an airborne differential absorption lidar (DIAL) to search for water sources. DIAL provides high-resolution measurements both day and night, bridging the observational gap between high-altitude water vapor and surface water, thus enhancing our understanding of water transport and loss on Mars. Absorption lines of water vapor in the 2.7 μm and 1.8 μm bands have been selected in this study. Simulations show that both lines are capable of detecting water vapor sources with reasonable system parameters.

lidar↗

Differential absorption lidar measurements of atmospheric water vapor using a pseudonoise code modulated AlGaAs laser

Lidar measurements using pseudonoise code modulated AlGaAs lasers are reported. Horizontal path lidar measurements were made at night to terrestrial targets at ranges of 5 and 13 km with 35 mW of average power and integration times of one second. Cloud and aerosol lidar measurements were made to thin cirrus clouds at 13 km altitude with Rayleigh (molecular) backscatter evident up to 9 km. Average transmitter power was 35 mW and measurement integration time was 20 minutes. An AlGaAs laser was used to characterize spectral properties of water vapor absorption lines at 811.617, 816.024, and 815.769 nm in a multipass absorption cell using derivative spectroscopy techniques. Frequency locking of an AlGaAs laser to a water vapor absorption line was achieved with a laser center frequency stability measured to better than one-fifth of the water vapor Doppler linewidth over several minutes. Differential absorption lidar measurements of atmospheric water vapor were made in both integrated path and range-resolved modes using an externally modulated AlGaAs laser. Mean water vapor number density was estimated from both integrated path and range-resolved DIAL measurements and agreed with measured humidity values to within 6.5 percent and 20 percent, respectively. Error sources were identified and their effects on estimates of water vapor number density calculated.

Rall, Jonathan A. R.↗

Development of an Airborne Triple-Pulse 2-Micron Integrated Path Differential Absorption Lidar (IPDA) for Simultaneous Airborne Column Measurements of Carbon Dioxide and Water Vapor in the Atmosphere

This presentation will provide status and details of an airborne 2-micron triple-pulse integrated path differential absorption (IPDA) lidar being developed at NASA Langley Research Center with support from NASA ESTO Instrument Incubator Program. The development of this active optical remote sensing IPDA instrument is targeted for measuring both atmospheric carbon dioxide and water vapor in the atmosphere from an airborne platform. This presentation will focus on the advancement of the 2-micron triple-pulse IPDA lidar development. Updates on the state-of-the-art triple-pulse laser transmitter will be presented including the status of seed laser locking, wavelength control, receiver and detector upgrades, laser packaging and lidar integration. Future plan for IPDA lidar system for ground integration, testing and flight validation will also be presented.

Singh, Upendra N.↗

Development of a Pulsed 2-Micron Integrated Path Differential Absorption Lidar for CO2 Measurement

Atmospheric carbon dioxide (CO2) is an important greenhouse gas that significantly contributes to the carbon cycle and global radiation budget on Earth. Active remote sensing of CO2 is important to address several limitations that contend with passive sensors. A 2-micron double-pulsed, Integrated Path Differential Absorption (IPDA) lidar instrument for ground and airborne atmospheric CO2 concentration measurements via direct detection method is being developed at NASA Langley Research Center. This active remote sensing instrument will provide an alternate approach of measuring atmospheric CO2 concentrations with significant advantages. A high energy pulsed approach provides high-precision measurement capability by having high signal-to-noise ratio level and unambiguously eliminates the contamination from aerosols and clouds that can bias the IPDA measurement. Commercial, on the shelf, components are implemented for the detection system. Instrument integration will be presented in this paper as well as a background for CO2 measurement at NASA Langley research Center

Singh, Upendra N.↗

2-Micron Triple-Pulse Integrated Path Differential Absorption Lidar Development for Simultaneous Airborne Column Measurements of Carbon Dioxide and Water Vapor in the Atmosphere

For more than 15 years, NASA Langley Research Center (LaRC) has contributed in developing several 2-micron carbon dioxide active remote sensors using the DIAL technique. Currently, an airborne 2-micron triple-pulse integrated path differential absorption (IPDA) lidar is under development at NASA LaRC. This paper focuses on the advancement of the 2-micron triple-pulse IPDA lidar development. Updates on the state-of-the-art triple-pulse laser transmitter will be presented including the status of wavelength control, packaging and lidar integration. In addition, receiver development updates will also be presented, including telescope integration, detection systems and data acquisition electronics. Future plan for IPDA lidar system for ground integration, testing and flight validation will be presented.

Singh, Upendra N.↗

Airborne 2-Micron Double-Pulsed Integrated Path Differential Absorption Lidar for Column CO2 Measurement

Double-pulse 2-micron lasers have been demonstrated with energy as high as 600 millijouls and up to 10 Hz repetition rate. The two laser pulses are separated by 200 microseconds and can be tuned and locked separately. Applying double-pulse laser in DIAL system enhances the CO2 measurement capability by increasing the overlap of the sampled volume between the on-line and off-line. To avoid detection complicity, integrated path differential absorption (IPDA) lidar provides higher signal-to-noise ratio measurement compared to conventional range-resolved DIAL. Rather than weak atmospheric scattering returns, IPDA rely on the much stronger hard target returns that is best suited for airborne platforms. In addition, the IPDA technique measures the total integrated column content from the instrument to the hard target but with weighting that can be tuned by the transmitter. Therefore, the transmitter could be tuned to weight the column measurement to the surface for optimum CO2 interaction studies or up to the free troposphere for optimum transport studies. Currently, NASA LaRC is developing and integrating a double-Pulsed 2-micron direct detection IPDA lidar for CO2 column measurement from an airborne platform. The presentation will describe the development of the 2-micron IPDA lidar system and present the airborne measurement of column CO2 and will compare to in-situ measurement for various ground target of different reflectivity.

Singh, Upendra N.↗

Integrated Path Differential Absorption Lidar Optimizations Based on Pre-Analyzed Atmospheric Data for ASCENDS Mission Applications

In this paper a modeling method based on data reductions is investigated which includes pre analyzed MERRA atmospheric fields for quantitative estimates of uncertainties introduced in the integrated path differential absorption methods for the sensing of various molecules including CO2. This approach represents the extension of our existing lidar modeling framework previously developed and allows effective on- and offline wavelength optimizations and weighting function analysis to minimize the interference effects such as those due to temperature sensitivity and water vapor absorption. The new simulation methodology is different from the previous implementation in that it allows analysis of atmospheric effects over annual spans and the entire Earth coverage which was achieved due to the data reduction methods employed. The effectiveness of the proposed simulation approach is demonstrated with application to the mixing ratio retrievals for the future ASCENDS mission. Independent analysis of multiple accuracy limiting factors including the temperature, water vapor interferences, and selected system parameters is further used to identify favorable spectral regions as well as wavelength combinations facilitating the reduction in total errors in the retrieved XCO2 values.

Pliutau, Denis↗

Differential absorption lidar technique for measurement of the atmospheric pressure profile

A new two-wavelength lidar technique for remotely measuring the pressure profile using the trough absorption region between two strong lines in the oxygen A band is described. The theory of integrated vertical path, differential ranging, and horizontal-path pressure measurements is given, with methods to desensitize and correct for temperature effects. The properties of absorption troughs are described and shown to reduce errors due to laser frequency jitter by up to two orders of magnitude. A general analysis, including laser bandwidth effects, demonstrates that pressure measurements with an integrated-vertical-path technique are typically fifty times more accurate than with a differential ranging technique. Simulations show 0.1-0.3 percent accuracy for ground and Shuttle-based pressure-profile and surface-pressure experiments.

Korb, C. L.↗

Complementarity of UV and IR differential absorption lidar for global measurements of atmospheric species

An analysis of the potential capabilities of a spectrally diversified DIAL technique for monitoring atmospheric species is presented assuming operation from an earth-orbiting platform. Emphasis is given to the measurement accuracies and spatial and temporal resolutions required to meet present atmospheric science objectives. The discussion points out advantages of spectral diversity to perform comprehensive studies of the atmosphere; in general it is shown that IR systems have an advantage in lower atmospheric measurements, while UV systems are superior for middle and upper atmospheric measurements.

Megie, G.↗