Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Predicting the 3D fatigue crack growth rate of small cracks using multimodal data via Bayesian networks: In-situ experiments and crystal plasticity simulations

Small crack propagation accounts for most of the fatigue life of engineering structures subject to high cycle fatigue loading conditions. Determining the fatigue crack growth rate of small cracks propagating into polycrystalline engineering alloys is critical to improving fatigue life predictions, thus lowering cost and increasing safety. In this work, cycle-by-cycle data of a small crack propagating in a beta metastable titanium alloy is available via phase and diffraction contrast tomography. Crystal plasticity simulations are used to supplement experimental data regarding the micromechanical fields ahead of the crack tip. Experimental and numerical results are combined into a multimodal dataset and sampled utilizing a non-local data mining procedure. Furthermore, to capture the propensity of body-centered cubic metals to deform according to the pencil-glide model, a non-local driving force is postulated. The proposed driving force serves as the basis to construct a data-driven probabilistic crack propagation framework using Bayesian networks as building blocks. The spatial correlation between the postulated driving force and experimental observations is obtained by analyzing the results of the proposed framework. Results show that the above correlation increases proportionally to the distance from the crack front until the edge of the plastic zone. Moreover, the predictions of the propagation framework show good agreement with experimental observations. Finally, we studied the interaction of a small crack with grain boundaries (GBs) utilizing various slip transmission criteria, revealing the tendency of a crack to cross a GB by propagating along the slip directions minimizing the residual Burgers vector within the GB.

36 MATERIALS SCIENCE↗

An investigation of cathodoluminescence in albite from the A-type Georgeville granite, Nova Scotia

Cathodoluminescence (CL) reveals red and blue colors within single, non-turbid albite (Ab{sub 98-99}) grains from the Georgeville granite, Nova Scotia. A 720 nm X-ray excited optical luminescence (XEOL) peak characterizes red CL regions, while a 280 nm XEOL feature dominates blue CL regions. Synchrotron X-ray fluorescence results indicate that red CL and the 720 nm XEOL peak intensities relate to total Fe concentrations. The relationship between red CL and Fe content is confirmed by electron microprobe (EMPA) and laser ablation-inductively coupled mass spectrometry (LA-ICP-MS). The XEOL technique is used to exclude the Fe K-edge as the cause of red CL. X-ray absorption spectroscopy results indicate that Fe in both the red and blue CL regions is Fe{sup 3+}, and that red CL activation may relate to the Si-Al order of the feldspar and to the distribution of Fe on tetrahedral sites. The CL textures, combined with EMPA and LA-ICPMS analyses, indicate that blue CL albite (Ab98) regions contain higher concentrations of Ca, Ti, Pb and rare earth elements, and were replaced, in part, by a more Fe-rich, trace element depleted albite (Ab99) which displays red CL. Complex diffraction contrasts and amorphous deposits identified in transmission electron microscope images suggest that aqueous fluids have reacted with both red and blue CL regions. Fluid inclusion homogenization temperatures of up to 430 C provide a lower estimate of the fluid temperature.

58 GEOSCIENCES↗

Simulation of kinematic Kikuchi diffraction patterns from atomistic structures

One of the limitations of atomistic simulations is that many of the computational tools used to extract structural information from atomic trajectories provide metrics that are not directly compatible with experiments for validation. In this work, to bridge between simulation and experiment, a method is presented to produce simulated Kikuchi diffraction patterns using data from atomistic simulations, without requiring a priori specification of the crystal structure or defect periodicity. The Kikuchi pattern simulation is based on the kinematic theory of diffraction, with Kikuchi line intensities computed via a discrete structure factor calculation. Reciprocal lattice points are mapped to Kikuchi lines using a geometric projection of the reciprocal space data. This method is validated using single crystal atomistic models, and the novelty of this approach is emphasized by simulating kinematic Kikuchi diffraction patterns from an atomistic model containing a nanoscale dislocation loop. Deviations in kinematic Kikuchi line intensities are explained considering the displacement field of the dislocation loop, as is done in diffraction contrast theory.

42 ENGINEERING↗

In situ indentation and high cycle tapping deformation responses in a nanolaminate crystalline/amorphous metal composite

The incorporation of nanostructured and amorphous metals into modern applications is reliant on the understanding of deformation and failure modes in constrained conditions. To study this, a 105 nm crystalline Cu/160 nm amorphous Cu 45 Zr 55 (at.%) multilayer structure was fabricated with the two crystalline layers sputter deposited between the top-middle-bottom amorphous layers and prepared to electron transparency. The multilayer was then in situ indented either under a single load to a depth of ~ 100 nm (max load of ~ 100 μN) or held at 20 μN and then repeatedly indented with an additional 5 μN up to 20,000 cycles in a transmission electron microscope to compare the deformation responses in the nanolaminate. For the single indentation test, the multilayer showed serrated load-displacement behavior upon initial indentation inductive of shear banding. Additionally, at an indentation depth of ~ 32 nm, the multilayer exhibited perfect plastic behavior and no strain hardening. Both indented and fatigue-indented films revealed diffraction contrast changes with deformation. Subsequent Automated Crystal Orientation Mapping (ACOM) measurements confirmed and quantified global texture changes in the crystalline layers with specifically identified grains revealing rotation. Using a finite element model, the in-plane displacement vectors under the indent mapped conditions where ACOM determined grain rotation was observed, indicating the stress flow induced grain rotation. Furthermore, the single indented Cu layers also exhibited evidence of deformation induced grain growth, which was not evident in the fatigue-indented Cu based multilayer. Finally, the single indented multilayer retained a significant plastic crater in the upper most amorphous layer that directly contacted the indenter; a negligible crater impression in the same region was observed in the fatigued tested multilayer. These differences are explained by the different loading methods, applied load, and deformation mechanisms experienced in the multilayers.

36 MATERIALS SCIENCE↗

Toward accurate measurement of electromagnetic field by retrieving and refining the center position of non-uniform diffraction disks in Lorentz 4D-STEM

Recent advancement in scanning transmission electron microscopy (STEM) allows the use of 4D-STEM, a technique that captures an electron diffraction pattern at each scan point in STEM, to measure electrostatic and magnetic potential and field in materials. However, accurate measurement, separation of the magnetic and electric signals, and removal of artifacts remain challenging, especially in the presence of complex non-uniform diffraction contrast within the disks. In this work, based on dynamic simulations of 4D-STEM patterns built upon superstructures consisting of millions of atoms to account for different sample thickness and edge geometries, we show how the shape and intensity distribution of the central disk are affected by multiple scattering. We propose a robust refinement procedure through iteration of the spin-sensitive peak position of the disk-center in the circular Hough transform filtered images from experimental Lorentz 4D-STEM dataset after minimizing the possible artifacts, such as those due to the change of thickness, dynamic scattering, and scanning process. We verify that caution must be taken as in practice the rigid-disk-shift model used to reconstruct induction maps can easily break down due to disk-protrusion when there exists a nonconstant phase gradient or thickness within the width of the probe. Through quantitative analysis and comparing experiment with calculation the effect of the non-spin-related intensity distribution inside the disk as well as that causes the disk shift due to the intensity-protrusion can be removed, and high-quality magnetic field mapping is possible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automated Quantitative Analysis of Extended Irradiation Defects - Dislocations, Voids and Precipitates in Neutron Irradiated HT-9 Steel

Structural alloys that make up the core components of nuclear reactors are exposed to radiation that can substantially alter the microstructure and mechanical properties of the material. Irradiation can cause the formation of extended defects including dislocation line and loops, voids and various types of precipitates. To understand the irradiation effects, it is critical to characterize these defects individually and collectively to quantify how they evolve throughout irradiation stages. Transmission electron microscopy (TEM) is a standard tool for providing extensive size, number density and spatial distribution of extended irradiation defects, however, manual measurement of defect size and number density requires time-intensive effort to analyze enough defects that provide a statistically meaningful result and are prone to errors of subjectivity. In this work, we developed a set of MATLAB algorithms offering robust and automated identification and quantification of extended irradiation defects like dislocation lines, voids and precipitates commonly observed in neutron irradiated cladding alloys [1]. Using a neutron-irradiated HT-9 martensitic alloy irradiated at 412°C to 111.8 dpa, we demonstrate the capability of these algorithms for quantitative defect analysis. Figure 1 presents defect images of the HT-9 using an advanced diffraction contrast imaging scanning transmission electron microscopy (DCI STEM) that suppresses bend contours and provides better defect contrast compared to conventional TEM [2]. The first step of defect analysis is defect identification, a process that can be digitally achieved by contrast thresholding (for simple defect contrast) and by machine learning computer vision for defect semantic segmentation [3]. Here, labeled binary defect images (Figures 2a and 2c) were used. For dislocation density quantification, we employed an optimized circular-grid intersection method first introduced by Dr. John Steeds [4]. This method is shown in Figures 2a and 2b, where the number of intersections of dislocation lines with circular traces was measured. This produces an unbiased sampling of dislocation lines, regardless of their orientation. This process was optimized with automated digital intersection number and grid length registration. Interestingly, it was found that a relatively large number of circles in a set circular gird is was needed to produce an invariant result (Figure 2b), with a low systematic measurement error. This demonstrates the main advantage of computer-based defect analysis, in performing repetitive operations quickly with a reduced systematic error. For the quantitative analysis of voids and precipitates a challenge encountered with automated defect analysis is feature overlap, particularly when the density of voids/precipitates is high. To mitigate this problem, as shown in Figure 2d, we modified the popular circular Hough transformation and treated ‘circular shape’ as the particle descriptor for voids/precipitates, efficiently resolving the overlapping particles. In summary, this automated digital quantification together with machine learning enabled defect identification [3] opens new opportunities for standardizing the characterization workflow for quantitative analysis of extended irradiation defects.

Sainju, Rajat↗

Electron Tomography: Seeing Atoms in Three Dimensions

Our eyes - a parallel lens system - have the phenomenal ability to observe and "reconstruct" the three-dimensional world, relaying a 3-D image to our brains. Imaging of the nanoworld is best done with electrons rather than photons because of their lower wavelengths and higher resolution. The advent of aberration-correction has led to transmission electron microscopes with sub-Angstrom resolution that can resolve single atoms. Yet, no matter what detector is used, the resulting images are only two-dimensional projections of three-dimensional objects. Electron tomography is a technique that allows reconstruction of the three-dimensional structure and morphology of nanomaterials from such projections. X-ray tomography has been used in many branches of science for nearly half a century, and in the biological sciences electron tomography has been a powerful tool for understanding ultrastructure. However, for many years crystalline materials posed a challenge to electron tomography because diffraction contrast (a change in intensity in the image at particular crystal orientations) creates artifacts in the 3-D reconstruction. In 2003, with advances in scanning transmission electron microscopy, Midgley and colleagues obtained the first electron tomograms of crystalline materials. Shortly thereafter, Arslan et al. showed that the spatial resolution could be improved to 1 nm in all three spatial dimensions and visualized the formation of faceted 3.5-nm quantum dots embedded in a Si matrix. However, with that work existing reconstruction algorithms appeared to have reached their limit. To attain a resolution of 1 nm, a total of 140 images over ±78 degrees of tilt were needed. Writing in Nature Materials, Goris et al. now report a novel algorithm for 3-D reconstruction of the atomic structure of free-standing Au nanorods, using only four projection images. I.A. acknowledges collaboration with J.D. Roehling, K.J. Batenburg, B.C. Gates and A. Katz for Figure 1, supported in part by the DOE BES DE-SC0005822, and in part by the LDRD program at PNNL. The Pacific Northwest National Laboratory is operated by Battelle under contract DE-AC05-76RL01830.

Arslan, Ilke↗

Taking three-dimensional x-ray diffraction (3DXRD) from the synchrotron to the laboratory scale

Three-dimensional x-ray diffraction (3DXRD), a rotating x-ray diffraction technique, is a powerful tool for studying the micromechanical behavior of polycrystalline materials, capable of measuring the volume, position, orientation, and strain of thousands of grains simultaneously. However, its application has been historically limited to synchrotron facilities. Here, we present the first demonstration of laboratory-scale 3DXRD (Lab-3DXRD) using a liquid-metal-jet source. Lab-3DXRD achieves accuracy comparable to synchrotron-based 3DXRD, as validated against laboratory diffraction contrast tomography (LabDCT) and synchrotron-3DXRD. Over 96% of the grains detected with Lab-3DXRD are cross-validated, particularly for coarse grains (> ~60 μm), while the results suggest that finer grains should be accessible by taking advantage of high-efficiency detectors. We further demonstrate that its sensitivity to finer grains is enhanced by incorporating pre-characterization into the analysis. This study establishes Lab-3DXRD as a practical alternative to synchrotron techniques, making 3DXRD accessible to a wider range of academic and industrial researchers.

characterization and analytical techniques↗

Localized surface plasmon assisted contrast microscopy for ultrathin transparent specimens

We demonstrate a high contrast imaging technique, termed localized surface plasmon assisted contrast microscopy, by combining localized surface plasmon resonances (LSPR) and dark-field microscopy technique. Due to the sensitive response of LSPR to the refractive index of the surrounding media, this technique is capable of converting a small refractive index difference to a change in scattering intensity, resulting in a high-contrast, diffraction limited image of a thin unstained specimen with small, gradual refractive-index variation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Creep deformation mechanism mapping in nickel base disk superalloys

We investigated the creep deformation mechanisms at intermediate temperature in ME3, a modern Ni-based disk superalloy, using diffraction contrast imaging. Both conventional transmission electron microscopy (TEM) and scanning TEM were utilised. Distinctly different deformation mechanisms become operative during creep at temperatures between 677-815 °C and at stresses ranging from 274 to 724 MPa. Both polycrystalline and single-crystal creep tests were conducted. The single-crystal tests provide new insight into grain orientation effects on creep response and deformation mechanisms. Creep at lower temperatures (≤760 °C) resulted in the thermally activated shearing modes such as microtwinning, stacking fault ribbons and isolated superlattice extrinsic stacking faults. In contrast, these faulting modes occurred much less frequently during creep at 815 °C under lower applied stresses. Instead, the principal deformation mode was dislocation climb bypass. In addition to the difference in creep behaviour and creep deformation mechanisms as a function of stress and temperature, it was also observed that microstructural evolution occurs during creep at 760 °C and above, where the secondary coarsened and the tertiary precipitates dissolved. Based on this work, a creep deformation mechanism map is proposed, emphasising the influence of stress and temperature on the underlying creep mechanisms.

36 MATERIALS SCIENCE↗

Measurement and effects of polarization fields on one-monolayer-thick InN/GaN multiple quantum wells

Polarization fields associated with one-monolayer-thick InN/GaN multiple quantum wells (MQWs) cause shifts of the photoluminescence peak that depend on the GaN barrier layer thickness. Diffraction contrast and aberration-corrected scanning transmission electron microscopy show that the InN QWs are well defined and coherently strained. Mapping of electrostatic potential using off-axis electron holography shows that the electric fields inside the GaN barriers decrease from ~0.7 to ~0.2 MV/cm as the barrier layer thickness increases from 5 to 20 nm. Atomistic tight-binding calculations agree closely with experiment, and confirm that changes in optical emission of these III-nitride quantum wells result from changes in the spontaneous and piezoelectric polarization fields in the InN quantum wells and the GaN barrier layers. Overall, this QW system provides the basis for InN-based light-emitting devices operating across a useful band of wavelengths at room temperature.

Zhou, Lin↗

Ultrafast Self-Induced X-Ray Transparency and Loss of Magnetic Diffraction

Using ultrafast ≃2.5 fs and ≃25 fs self-amplified spontaneous emission pulses of increasing intensity and a novel experimental scheme, we report the concurrent increase of stimulated emission in the forward direction and loss of out-of-beam diffraction contrast for a Co/Pd multilayer sample. The experimental results are quantitatively accounted for by a statistical description of the pulses in conjunction with the optical Bloch equations. Here, the dependence of the stimulated sample response on the incident intensity, coherence time, and energy jitter of the employed pulses reveals the importance of increased control of x-ray free electron laser radiation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluation of neon focused ion beam milling for TEM sample preparation

Summary Gallium‐based focused ion beams generated from liquid–metal sources are widely used in micromachining and sample preparation for transmission electron microscopy, with well‐known drawbacks such as sample damage and contamination. In this work, an alternative (neon) focused ion beam generated by a gas field‐ionization source is evaluated for the preparation of electron‐transparent specimens. To do so, electron‐transparent sections of Si and an Al alloy are prepared with both Ga and Ne ion beams for direct comparison. Diffraction‐contrast imaging and energy dispersive x‐ray spectroscopy are used to evaluate the relative damage induced by the two beams, and cross‐sections of milled trenches are examined to compare the implantation depth with theoretical predictions from Monte Carlo simulations. Our results show that for the beam voltages and materials systems investigated, Ne ion beam milling does not significantly reduce the focused ion beam induced artefacts. However, the Ne ion beam does enable more precise milling and may be of interest in cases where Ga contamination cannot be tolerated.

PEKIN, T. C.↗

Flash electropolishing for TEM: Reducing FIB‐induced defects in tungsten with protocols for new materials

Focused ion beam (FIB) milling has become the dominant approach for site-specific transmission electron microscopy (TEM) specimen preparation; however, FIB damage remains a critical limitation for reliable microstructural characterisation, particularly in radiation effects studies. Tungsten is especially susceptible to FIB damage due to its high nuclear stopping power, which promotes the formation and strong diffraction contrast of FIB-induced ‘black spot’ defects that are indistinguishable from very fine irradiation-induced loops/defects resulting from low to intermediate temperature neutron irradiation. In this work, flash electropolishing is systematically evaluated as a post-FIB treatment for minimising preparation-induced artefacts for TEM analysis of tungsten-based alloys. Using a range of non-, ion-, and neutron-irradiated tungsten materials, the effectiveness of flash electropolishing has been assessed through direct comparison with conventional FIB and plasma-FIB preparation including low-energy Ga, Ar, Xe ion cleaning. The results demonstrate that flash electropolishing effectively removes FIB-damaged layers and ‘black spot’ defects, thereby enabling reliable observation of irradiation-induced dislocation structures. Key processing parameters governing flash electropolishing quality – including lamella thickness, applied voltage, polishing duration, electrolyte chemistry, and cathode geometry – have been systematically evaluated, and clear criteria were established for determining when flash electropolishing is required to ensure reliable microstructural analysis. This work also provides practical guidance for implementing flash electropolishing as an artefact-controlled specimen-preparation approach for TEM characterisation of FIB-produced specimens. The systematic protocol can be extended to other, non-tungsten materials.

TEM sample preparation↗

Direct imaging of short-range order and its impact on deformation in Ti-6Al

Chemical short-range order (SRO) within a nominally single-phase solid solution is known to affect the mechanical properties of alloys. While SRO has been indirectly related to deformation, direct observation of the SRO domain structure, and its effects on deformation mechanisms at the nanoscale, has remained elusive. Here, we report the direct observation of SRO in relation to deformation using energy-filtered imaging in a transmission electron microscope (TEM). The diffraction contrast is enhanced by reducing the inelastically scattered electrons, revealing subnanometer SRO-enhanced domains. The destruction of these domains by dislocation planar slip is observed after ex situ and in situ TEM mechanical testing. These results confirm the impact of SRO in Ti-Al alloys on the scale of angstroms. The direct confirmation of SRO in relationship to dislocation plasticity in metals can provide insight into how the mechanical behavior of concentrated solid solutions by the material’s thermal history.

36 MATERIALS SCIENCE↗

Dynamic X-ray diffraction imaging of the ferroelectric response in bismuth ferrite

Abstract X-ray diffraction imaging is rapidly emerging as a powerful technique by which one can capture the local structure of crystalline materials at the nano- and meso-scale. Here, we present investigations of the dynamic structure of epitaxial monodomain BiFeO 3 thin-films using a novel full-field Bragg diffraction imaging modality. By taking advantage of the depth penetration of hard X-rays and their exquisite sensitivity to the atomic structure, we imaged in situ and in operando, the electric field-driven structural responses of buried BiFeO 3 epitaxial thin-films in micro-capacitor devices, with sub-100 nm lateral resolution. These imaging investigations were carried out at acquisition frame rates that reached up to 20 Hz and data transfer rates of 40 MB/s, while accessing diffraction contrast that is sensitive to the entire three-dimensional unit cell configuration. We mined these large datasets for material responses by employing matrix decomposition techniques, such as independent component analysis. We found that this statistical approach allows the extraction of the salient physical properties of the ferroelectric response of the material, such as coercive fields and transient spatiotemporal modulations in their piezoelectric response, and also facilitates their decoupling from extrinsic sources that are instrument specific.

36 MATERIALS SCIENCE↗

Bent crystal X-ray topography

A television X-ray topographic camera system was constructed. The system differs from the previous system in that it incorporates the X-ray TV imaging system and has a semi-automatic wafer loading system. Also the X-ray diffraction is in a vertical plane. This feature makes wafer loading easier and makes the system compatible with any commercial X-ray generating system. Topographs and results obtained from a study of the diffraction contrast variation with impurity concentration for both boron implanted and boron diffused silicon are included.

Parker, D. L.↗

Dislocations in extruded Co-49.3 at. pct Al

Polycrystalline Co-49.3 at. pct Al, which had been extruded at 1505 K, was examined using transmission electron microscopy. Diffraction contrast analysis showed that b = 100 as well as b = 111 line dislocations contribute to elevated temperature deformation in CoAl. Therefore, it was concluded that sufficient slip systems exist in CoAl to allow for general plasticity in the absence of diffusional mechanisms. Line dislocations of the type b = 001 were observed on both 110 and 100 planes while b = 111 line dislocations were observed on 1 -1 0 planes.

Yaney, D. L.↗