Search NASA⌕ Search

SEARCH · Search NASA

Results for “digital frequency multiplexing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Low-Cutoff, High-Pass Digital Filtering of Neural Signals

The figure depicts the major functional blocks of a system, now undergoing development, for conditioning neural signals acquired by electrodes implanted in a brain. The overall functions to be performed by this system can be summarized as preamplification, multiplexing, digitization, and high-pass filtering. Other systems under development for recording neural signals typically contain resistor-capacitor analog low-pass filters characterized by cutoff frequencies in the vicinity of 100 Hz. In the application for which this system is being developed, there is a requirement for a cutoff frequency of 5 Hz. Because the resistors needed to obtain such a low cutoff frequency would be impractically large, it was decided to perform low-pass filtering by use of digital rather than analog circuitry. In addition, it was decided to timemultiplex the digitized signals from the multiple input channels into a single stream of data in a single output channel. The signal in each input channel is first processed by a preamplifier having a voltage gain of approximately 50. Embedded in each preamplifier is a low-pass anti-aliasing filter having a cutoff frequency of approximately 10 kHz. The anti-aliasing filters make it possible to couple the outputs of the preamplifiers to the input ports of a multiplexer. The output of the multiplexer is a single stream of time-multiplexed samples of analog signals. This stream is processed by a main differential amplifier, the output of which is sent to an analog-to-digital converter (ADC). The output of the ADC is sent to a digital signal processor (DSP).

Mojarradi,Mohammad↗

Possible methods for USSR-VLF navigation receivers

The U.S.S.R. has a VLF navigation system similar to OMEGA. Beukers has reported some information on the signal format, frequencies used, and the probable radiated power levels. From this data it appears possible to derive receiver operation modes and some implied reasons for the unique choice of the time-multiplexed frequency time base used. Of interest are receiver methods requiring processor gate complexity similar to a digital wristwatch including the use of mass-produced low frequency quartz crystal reference oscillators. The stability required of the local reference oscillator is probably much less critical than for other VLF receivers because of the signal format. One conclusion is that U.S.S.R.-VLF receivers might be fabricated at quite low cost making it possible for all persons in remote areas each to have his own private positioning aid. Further study of the actual transmitted signal format is warranted. While the nature of this memorandum is speculative because of the lack of confirming data, the receiver method proposed has evolved from related principles which have been applied to the operating OMEGA-VLF navigation system.

Burhans, R. W.↗

Fiber optic multiplex optical transmission system

A multiplex optical transmission system which minimizes external interference while simultaneously receiving and transmitting video, digital data, and audio signals is described. Signals are received into subgroup mixers for blocking into respective frequency ranges. The outputs of these mixers are in turn fed to a master mixer which produces a composite electrical signal. An optical transmitter connected to the master mixer converts the composite signal into an optical signal and transmits it over a fiber optic cable to an optical receiver which receives the signal and converts it back to a composite electrical signal. A de-multiplexer is coupled to the output of the receiver for separating the composite signal back into composite video, digital data, and audio signals. A programmable optic patch board is interposed in the fiber optic cables for selectively connecting the optical signals to various receivers and transmitters.

Bell, C. H.↗

Shuttle S-band communications technical concepts

Using the S-band communications system, shuttle orbiter can communicate directly with the Earth via the Ground Spaceflight Tracking and Data Network (GSTDN) or via the Tracking and Data Relay Satellite System (TDRSS). The S-band frequencies provide the primary links for direct Earth and TDRSS communications during all launch and entry/landing phases of shuttle missions. On orbit, S-band links are used when TDRSS Ku-band is not available, when conditions require orbiter attitudes unfavorable to Ku-band communications, or when the payload bay doors are closed. the S-band communications functional requirements, the orbiter hardware configuration, and the NASA S-band communications network are described. The requirements and implementation concepts which resulted in techniques for shuttle S-band hardware development discussed include: (1) digital voice delta modulation; (2) convolutional coding/Viterbi decoding; (3) critical modulation index for phase modulation using a Costas loop (phase-shift keying) receiver; (4) optimum digital data modulation parameters for continuous-wave frequency modulation; (5) intermodulation effects of subcarrier ranging and time-division multiplexing data channels; (6) radiofrequency coverage; and (7) despreading techniques under poor signal-to-noise conditions. Channel performance is reviewed.

Seyl, J. W.↗

Optical linear algebra processors - Noise and error-source modeling

The modeling of system and component noise and error sources in optical linear algebra processors (OLAPs) are considered, with attention to the frequency-multiplexed OLAP. General expressions are obtained for the output produced as a function of various component errors and noise. A digital simulator for this model is discussed.

Casasent, D.↗

Simulation and Analysis of Opportunistic MSPA for Multiple Cubesat Deployments

We describe a software approach for simultaneous demodulation and decoding of multiple frequency- multiplexed spacecraft across multiple ground stations. The approach involves the use of a single ground antenna with wide enough aperture to receive multiple angularly adjacent spacecraft simultaneously. This technique uses a wide-band RF signal digitizer coupled with easily and cheaply duplicated software-receiver modules to independently process the frequency-channelized downlink signals from the spacecraft. This approach relaxes the need for realizable modems at each antenna, for example in the Deep-SpaceNetwork (DSN), and can also function as a delayed data retrieval method for cubesat missions with routine science data return. Thus, we hope that this solution can enable more efficient utilization of DSN assets. We concentrate on a simulation similar to the proposed Exploration Mission 1 (EM-1) mission from a geometric perspective. To that end, the simulated scenario involves ten secondary cubesats deployed and tracked for a span of four days (the modeled motion over the first four days of the mission does not include any Trajectory Correction Maneuvers (TCMs) that may be necessary as the cubesats approach the moon). Transmissions from the cubesats may be received through a combination of DSN ground sites based on visibility. The cubesats are assumed to utilize typical cubesat transmit powers and a waveform similar to that of the Iris radio. One cubesat is chosen as the “target” and is considered tracked by all ground-stations throughout the simulation (i.e., it is consistently at the center of the main lobe of each ground station antenna when the ground station is in view of the cubesat in terms of elevation angle). The simulation effort involves synthesizing a wideband signal that includes the ten cubesats across a large bandwidth due to each cubesat having its own center-frequency in X-band, near 8.4 GHz. Each signal is characterized by its own Doppler-frequency shift and free-space path-loss computed through the underlying geometry of the simulation as well as the cubesat transmit power. Finally, each cubesat signal experiences a unique antenna gain at each ground station due to the underlying antenna pattern and spacecraft-ground station geometry. We establish two interesting findings: First, the link-budget for the EM-1-like scenario is almost completely limited by the angle between the center of the antenna main beam and the cubesat, which means that the signal-to-noise ratio is wholly adequate for demodulation and decoding at the simulated bitrates unless the cubesat exits the main beam. Secondly, and fortunately due to the use of a software radio architecture, we show that it is possible to successfully receive signals from most cubesats for the entire 4-day simulation. Due to the signal-to-noise ratio being sufficient for demodulation even after the side-lobe’s 17dB reduction in SNR, the software radio can still demodulate such cubesats as long as the radio is capable of re-establishing carrier lock as the cubesats leave the main beam and enter the side-lobe. Considering that the target application utilizes offline processing, a loss of lock can be detected and lock can be re-established by iterating over the data. Extensive simulations demonstrate these results.

Abraham, Douglas S.↗

Frequency domain multiplexing of pulse mode radiation detectors

The capability to multiplex scintillation detectors or other pulse mode radiation detectors is necessary in some applications where a large number of detectors is required. Frequency domain multiplexing has been previously implemented for applications in astronomy using amplitude modulation on radiation detectors such as transition-edge sensors. We propose here an alternative method for multiplexing pulse mode radiation detectors in the frequency domain using convolution. We pass the detector signal to a resonator circuit that converts a detector pulse to a damped sinusoid of a specific frequency which gives a unique tag to the detector. We have developed a prototype frequency-domain multiplexed system for four EJ-309 organic scintillator detectors using four resonators of unique frequencies. The resonator outputs are combined using a fan-in circuit which is then connected to a single digitizer input. Using this system, we further demonstrate that the charge collected under the original anode pulse can be estimated from the power spectrum of the damped sinusoid with a relative uncertainty of about 2%. The time-of-arrival of the anode pulse can be estimated using constant fraction discrimination applied to the leading edge of the damped sinusoid with an uncertainty of about 450 ps. We also used a CeBr3 detector to test the performance of our system for spectroscopic applications and found only small degradation in the resolution for a multiplexed detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and characterization of the SPT-3G receiver (Conference Presentation)

(On behalf of the SPT-3G collaboration)The SPT-3G receiver was commissioned in early 2017 on the 10-meter South Pole Telescope (SPT) to map the Cosmic Microwave Background (CMB) with arcminute resolution. The new instrument significantly improves on previous SPT camera designs, offering unprecedented sensitivity to the CMB’s temperature and polarization anisotropies while maintaining a tight control on systematic effects.A restructured optics chain features new secondary and tertiary mirrors to increase the receiver’s field of view by a factor of four in area, coupling light through a set of four cryogenic 720 mm alumina elements, which re-image the Gregorian focus inside the receiver. The broad-band (70-270 GHz) anti-reflective coated lenses are paired with a Lyot stop and cooled to 4 K using a dedicated two-stage pulse-tube cooler (PTC) to minimize in-band attenuation, internal radiative loading, and stray light on the considerably larger focal plane, which is populated with ~2,700 diffraction-limited pixels.Each independent pixel incorporates a lenslet-coupled broadband sinuous antenna, which routes signals through superconducting transmission lines and in-line band-defining filters to six transition-edge sensors, each measuring one of three bands (90, 150, and 220 GHz) and two polarizations, yielding a total of ~16,000 bolometers distributed across ten 150 mm monolithic wafers on a 430 mm image plane. A robust mechanical and thermal architecture supports and cools all detectors across this sizable focal plane to ~250 mK using a closed-cycle Helium adsorption refrigerator backed by a PTC, allowing a duty cycle greater than 90%.This order of magnitude increase in detector count relies on an improved digital frequency-domain SQUID readout system which integrates superconducting inductor-capacitor resonators wired in series with each bolometer to achieve a 68x multiplexing factor while mitigating noise and crosstalk effects.Cumulatively, SPT-3G’s new optics, detector, and readout strategies boast a potential factor of ~20 improvement in mapping speed over its predecessor, SPT-Pol, offering the potential to improve our understanding of inflationary physics, astroparticle physics, and growth of structure. We summarize the new receiver’s core design principles, outline technology characterization results, and report on plans for future upgrades.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photonic Doppler Velocimetry Multiplexing Techniques: Evaluation of Photonic Techniques

This poster reports progress related to photonic technologies. Specifically, the authors developed diagnostic system architecture for a Multiplexed Photonic Doppler Velocimetry (MPDV) that incorporates frequency and time-division multiplexing into existing PDV methodology to provide increased channel count. Current MPDV design increases number of data records per digitizer channel 8x, and also operates as a laser-safe (Class 3a) system. Further, they applied heterodyne interferometry to allow for direction-of-travel determination and enable high-velocity measurements (>10 km/s) via optical downshifting. They also leveraged commercially available, inexpensive and robust components originally developed for telecom applications. Proposed MPDV architectures employ only commercially available, fiber-coupled hardware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical support for digital systems technology development. Task order 1: ISP contention analysis and control

Alternatives for realizing a packet-based network switch for use on a frequency division multiple access/time division multiplexed (FDMA/TDM) geostationary communication satellite were investigated. Each of the eight downlink beams supports eight directed dwells. The design needed to accommodate multicast packets with very low probability of loss due to contention. Three switch architectures were designed and analyzed. An output-queued, shared bus system yielded a functionally simple system, utilizing a first-in, first-out (FIFO) memory per downlink dwell, but at the expense of a large total memory requirement. A shared memory architecture offered the most efficiency in memory requirements, requiring about half the memory of the shared bus design. The processing requirement for the shared-memory system adds system complexity that may offset the benefits of the smaller memory. An alternative design using a shared memory buffer per downlink beam decreases circuit complexity through a distributed design, and requires at most 1000 packets of memory more than the completely shared memory design. Modifications to the basic packet switch designs were proposed to accommodate circuit-switched traffic, which must be served on a periodic basis with minimal delay. Methods for dynamically controlling the downlink dwell lengths were developed and analyzed. These methods adapt quickly to changing traffic demands, and do not add significant complexity or cost to the satellite and ground station designs. Methods for reducing the memory requirement by not requiring the satellite to store full packets were also proposed and analyzed. In addition, optimal packet and dwell lengths were computed as functions of memory size for the three switch architectures.

Stehle, Roy H.↗

LU and Cholesky decomposition on an optical systolic array processor

Direct solutions of matrix-vector equations on an optical systolic array processor are considered. The solutions are discussed and a parallel algorithm for LU matrix decomposition that is very attractive for an optical realization is formulated. It is noted that when direct techniques are used, it is preferable to realize the matrix decomposition on an optical system and to utilize a digital processor for the solution of the simplified resultant matrix-vector problem. One method of realizing LU matrix decomposition on a new frequency-multiplexed optical systolic array matrix-matrix processor is described. A simple method for extending the process of LU decomposition to Cholesky decomposition on the optical processor is discussed.

Casasent, D.↗

Development of Space-Flight Compatible Room-Temperature Electronics for the Lynx X-Ray Microcalorimeter

We are studying the development of space-flight compatible room-temperature electronics for the Lynx x-ray microcalorimeter (LXM) of the Lynx mission. The baseline readout technique for the LXM is microwave SQUID multiplexing. The key modules at room temperature are the RF electronics module and the digital electronics and event processor (DEEP). The RF module functions as frequency converters and mainly consists of local oscillators and I/Q mixers. The DEEP performs demultiplexing and event processing, and mainly consists of field-programmable gate arrays, ADCs, and DACs. We designed the RF electronics and DEEP to be flight ready, and estimated the power, size, and mass of those modules. There are two boxes each for the RF electronics and DEEP for segmentation, and the sizes of the boxes are 13 in: × 13 in: × 9 in: for the RF electronics and 15.5 in: × 11.5 in: × 9.5 in: for the DEEP. The estimated masses are 25.1 kg∕box for the RF electronics box and 24.1 kg∕box for the DEEP box. The maximum operating power for the RF electronics is 141 W or 70.5 W∕box, and for the DEEP box is 615 W or 308 W∕box. The overall power for those modules is 756 W. We describe the detail of the designs as well as the approaches to the estimation of resources, sizes, masses, and powers.

Sakai, Kazuhiro↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The Muon g - 2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment, a μ , of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, ω α , of muons stored in a magnetic field of 1.45 T, and a precise measurement of that magnetic field in terms of the shielded proton Larmor frequency, ω' ρ . The measurement of ω' ρ with a total systematic uncertainty of 70 parts-perbillion involves a combination of various nuclear magnetic resonance (NMR) probes. There are 378 probes mounted in fixed locations that constantly monitor field drifts. A water-based, cylindrical calibration probe provides the calibration in terms of the shielded proton Larmor frequency. A crucial element for the multi-step measurement of ω' ρ is the regular mapping of the magnetic field over the muon storage region. The former experiment at Brookhaven National Laboratory (BNL) employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include the addition of 16-bit, 1 MSPS digitization of the NMR signals, which replaced the hardware-implemented zero-crossing counting of the system at Brookhaven. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. To sustain the higher data rates, a new communication scheme with time-division multiplexing was implemented to separate the important NMR reference clock from the data communication in order to reach the specifications for the accuracy and stability of the reference clock. A new barcode reader provides more precise azimuthal position determination during the measurement and calibration. While the mechanical systems that move the field mapper inside the storage ring have been mostly refurbished from BNL, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first three data taking periods of the experiment at Fermilab. Finally, this article will provide the details of the upgrades of the field mapper and its performance.

47 OTHER INSTRUMENTATION↗

Time and frequency for digital telecommunications

Time and frequency (T and F) are fundamental and pervasive parameters of telecommunication technology. Advancing development of digital communications using data modulation rates above 2400 baud and time-division multiplex in complex network configurations is now requiring more accurate and precise T and F reference information for efficient operation of telecommunication systems. A schematic diagram of a general communication system is shown. This diagram is very general and can depict any type of communication. The information source selects a specific message which is encoded and sent through a communication channel. Enroute, the signal is subjected to perturbations from environmental noise. The received signal is then decoded and delivered to its destination. Through the process, the message may undergo many spurious changes, resulting in a loss of information content in the delivered message as compared to the original selected message. In digital telecommunication systems, loss of information content of the signals can be attributed to noise, distortion of waveshape, and loss of synchronization.

Folts, H. C.↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The E989 Muon g-2 experiment at Fermilab aims to measure the anomalous magnetic moment, a$_\mu$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, $\omega_a$, and the average magnetic field in terms of the equivalent, free proton Larmor frequency, $\omega_p$. The measurement of $\omega_p$ with a total systematic uncertainty of 70 parts-per-billion involves a combination of various NMR probes. There are 378 probes in fixed locations constantly monitoring field drifts. A water-based probe provides the calibration in terms of $\omega_p$. A crucial element for the multi-step measurement of $\omega_p$ is the regular mapping of the magnetic field over the muon storage region. The former E821 experiment at Brookhaven employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include a new communication scheme incorporating time-division multiplexing to separate the important NMR reference clock from the data communication. The addition digitization of the NMR signals replaced the hardware-implemented zero-crossing counting of the E821 system. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. While the mechanical systems that move the field mapper around the ring have been mostly refurbished, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first data taking periods. This article provides details of the upgrades of the field mapper and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler compensation by shifting transmitted object frequency within limits

A system and method are disclosed for position locating, deriving centralized air traffic control data, and communicating via voice and digital signals between a multiplicity of remote aircraft, including supersonic transports, and a central station. Such communication takes place through a synchronous satellite relay station. Side tone ranging patterns, as well as the digital and voice signals, are modulated on a carrier transmitted from the central station and received on all of the supersonic transports. Each aircraft communicates with the ground stations via a different frequency multiplexed spectrum. Supersonic transport position is derived from a computer at the central station and supplied to a local air traffic controller. Position is determined in response to variable phase information imposed on the side tones at the aircrafts. Common to all of the side tone techniques is Doppler compensation for the supersonic transport velocity.

Laughlin, C. R., Jr.↗

Transmission of multiplexed video signals in multimode optical fiber systems

Kennedy Space Center has the need for economical transmission of two multiplexed video signals along multimode fiberoptic systems. These systems must span unusual distances and must meet RS-250B short-haul standards after reception. Bandwidth is a major problem and studies of the installed fibers, available LEDs and PINFETs led to the choice of 100 MHz as the upper limit for the system bandwidth. Optical multiplexing and digital transmission were deemed inappropriate. Three electrical multiplexing schemes were chosen for further study. Each of the multiplexing schemes included an FM stage to help meet the stringent S/N specification. Both FM and AM frequency division multiplexing methods were investigated theoretically and these results were validated with laboratory tests. The novel application of quadrature amplitude multiplexing was also considered. Frequency division multiplexing of two wideband FM video signal appears the most promising scheme although this application requires high power highly linear LED transmitters. Futher studies are necessary to determine if LEDs of appropriate quality exist and to better quantify performance of QAM in this application.

White, Preston, III↗