Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct load control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Comparison of wind farm control strategies under realistic offshore wind conditions: turbine quantities of interest

Abstract. Wind farm flow control is a strategy to increase the efficiency and therefore lower the levelized cost of energy of a wind farm. This is done using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the flow behind the turbine, affecting downstream turbines in the farm. Two inherently different wind farm flow control methods have been identified in the literature: wake steering and wake mixing. This paper focuses on comparing the turbine quantities of interest between these methods for a simple two-turbine wind farm setup, while a companion article (Brown et al., 2025) focuses on the wake quantities of interest for a single wind turbine setup. Both papers use the same set of wind farm simulations based on high-fidelity large-eddy simulations (LESs) coupled with OpenFAST turbine models. First, precursor simulations are executed in order to match wind conditions measured with lidars in an offshore wind farm off the east coast of the USA. These measurements show general wind conditions that exhibit substantially higher vertical wind shear and veer than any of the LES studies performed with wind farm flow control strategies currently available in the literature. The precursors are used to evaluate the effectiveness of the control methods. In the LES, the wind veer leads to highly skewed wakes, which have considerable influence on the power uplift of wind farm flow control strategies. In addition to a baseline controller, four different control strategies, each of which uses either pitch or yaw control, are performed on the upstream turbine of a simple two-turbine wind farm. Assuming that the wind direction is known and constant over time, the simulations show that wake steering is generally the superior wind farm flow control strategy, considering both wind farm power production and turbine damage equivalent loads when substantial wind veer is present. This result is consistent over different wind speeds and wind directions. On the other hand, for similar wind conditions with lower veer, wake mixing was found to yield the highest power production, although at the expense of generally higher loads. This leads us to conclude that the effect of wind veer, which has so far not usually been considered, can not be neglected when determining the optimal wind farm flow control strategy.

17 WIND ENERGY↗

Effects of the method of active site characterization for determining structure-sensitivity in Ag-catalyzed ethylene epoxidation

We report catalysts have been prepared on a low surface area α-Al 2 O 3 support used commercially for previous generation olefin epoxidation catalysts. Prescreening of the low surface area alumina (0.73 m 2 /g) indicated the absence of acid catalyzed isomerization of EO at an evaluation temperature of 210 °C. A 0.1 wt% Ag base material synthesized by incipient wetness impregnation of AgNO 3 was used as a base material for electroless deposition (ED) of additional Ag to increase particle sizes by controlled reduction of Ag + directly onto the preexisting Ag surface to form weight loadings between 0.3 and 5.0 wt% metal. A 12 wt% Ag/α-Al 2 O 3 using Ag 2 C 2 O 4 as the Ag precursor was also prepared to compare performance of the ED samples with a catalyst more typical of industrial formulations. Characterization by SEM, STEM, and hydrogen titration of oxygen precovered Ag characterized before and after catalytic evaluation indicated that microscopy is required to accurately represent distributions of Ag particle sizes, but H 2 titration of O-precovered Ag gives the best representation of active sites since it directly counts the number of Ag surface sites. Larger particles >100 nm are resistant to both Ag sintering and carbon foulant; TOF values were relatively insensitive to particle size with only a 2.2 × difference between the best and worst performing samples. Selectivity, which is not a function of TOF, shows the most significant structure sensitivity effect where particle sizes follow the trend 67 nm ≈ 92 nm (58% EO) < 157 nm (67% EO) < 211–542 nm (73% EO). The lower EO selectivities were also correlated with increased fouling for the smaller Ag sizes, suggesting that more strongly bound EO precursor(s) leads to combustion and CO 2 /H 2 O formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technology Enablers for Advanced Gasoline Compression Ignition Engines

To meet current emission regulations and increasingly demanding global fleet CO2 standards on fuel economy and future trends towards life cycle GHG emissions, advanced combustion engines remain significant in the passenger vehicle sector to achieve high efficiency and low emissions over the full operating range. Lean burn gasoline compression ignition (GCI) technology has shown to have the most potential in reaching these goals, although it faces challenges in the operating range. In this study, an advanced GCI engine is considered with the capability to operate under two combustion modes, namely low temperature combustion (LTC) and GCI. They are enabled with the use of two Hyundai in-house developed technologies; an advanced valve control mechanism known as continuously variable valve duration (CVVD) and a high-pressure gasoline injection system. At low load, the engine utilizes dual CVVD and dual CVVT (continuously variable valve timing) mechanisms for both intake and exhaust valvetrains to enable NVO (negative valve overlap) to trap hot residuals. The hot residuals enable low load auto-ignition, and the phasing control of that auto-ignition is achieved by varying the degrees of NVO, and in turn, the amount of hot residuals. This is done in real time with respect to the changes in engine loads or operating conditions, significantly improving cylinder-phasing control in LTC mode, and subsequently is able to realize a fuel economy gain and reduced emission benefits. Early direct injection during NVO or intake stroke is used to form homogenous or quasi-homogenous air-fuel mixture for LTC. At mid to high loads, late direct injection of gasoline or GCI mode is employed to take advantage of the high volatility and high resistance to auto-ignition of gasoline fuel, so that diesel-engine like high combustion efficiency can be achieved with lower soot emissions for the same NOx level as diesel combustion. In this paper, the key control and fueling technologies that enable this multiple mode combustion are introduced, and the resultant analysis on engine test and CFD simulation at LTC and GCI operating conditions are presented in detail.

Gasoline compression ignition, low temperature com↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗

Loads Response That is Due to Wake Steering on a Pair of Utility-Scale Wind Turbines

The goal of this report is to present the resulting turbine loads of a full-scale wind turbine wake steering field campaign. In this experiment, wake steering controls were applied to an upwind turbine (T2) and the downwind turbine (T3) was instrumented to measure mechanical loads. The test subjects (T2 & T3) were GE 1.5SLE CWE turbines located on a wind farm with a prevailing wind direction coming from the northwest. The data collection strategy involved toggling the wake steering controls of T2 between on and off. This resulted in two databases (baseline and wake steered) with similar turbulence intensities. Valid data was extracted and processed. The analysis involved scaling data to engineering units, applying coordinate transformations where applicable, calculating 10-minutes statistics, and calculating damage equivalent loads (DELs) to assess fatigue. Figures are shown as statistics and DELs binned by wind speed with supplemental scatter plots provided in the appendices. Results between the baseline and wake steered databases were compared. Overall, the binned statistics showed minimal differences in loading between the two cases. However, the DELs of the wake steered case were observed to be consistently smaller than the baseline for most of the turbine components. A potential for future work was recognized based on the findings of this report. Some areas of further study include an analysis for more granular loads sensitivity to different yaw offset angles and rotor wake overlap, an in-depth comparison of loads between the upwind and downwind turbines, and further fatigue analysis to quantify differences observed in this experiment.

17 WIND ENERGY↗

Ultrafast dense DNA functionalization of quantum dots and rods for scalable 2D array fabrication with nanoscale precision

Scalable fabrication of two-dimensional (2D) arrays of quantum dots (QDs) and quantum rods (QRs) with nanoscale precision is required for numerous device applications. However, self-assembly–based fabrication of such arrays using DNA origami typically suffers from low yield due to inefficient QD and QR DNA functionalization. In addition, it is challenging to organize solution-assembled DNA origami arrays on 2D device substrates while maintaining their structural fidelity. Here, we reduced manufacturing time from a few days to a few minutes by preparing high-density DNA-conjugated QDs/QRs from organic solution using a dehydration and rehydration process. We used a surface-assisted large-scale assembly (SALSA) method to construct 2D origami lattices directly on solid substrates to template QD and QR 2D arrays with orientational control, with overall loading yields exceeding 90%. Our fabrication approach enables the scalable, high fidelity manufacturing of 2D addressable QDs and QRs with nanoscale orientational and spacing control for functional 2D photonic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Trade-Off Study Between the Primary and Transient Responses of Grid-Forming Inverters

The control parameters of the grid-forming (GFM) inverter-based resources (IBRs) directly impact power system dynamics. The primary control requires the GFM inverter to balance generation and load. It is also preferred that a GFM inverter maintain the terminal frequency after a power system fault. In this paper, we investigate the trade-off between the primary control objective and the transient response. To quantify the transient performance of the GFM inverter, we introduce a new real-time transient stability index (TSI). This index plays a crucial role in our investigation, as it allows us to compare the performance trade-offs of different sets of GFM control parameters.

Lin, Xuheng↗

Restoring Critical Loads In Resilient Distribution Systems using A Curriculum Learned Controller

In this paper, we propose a curriculum learned reinforcement learning (RL) controller to facilitate distribution system critical load restoration (CLR), leveraging RL's fast online response and its outstanding optimal sequential control capability. Like many grid control problems, CLR is complicated due to the large control action space and renewable uncertainty in a heavily constrained non-linear environment with strong intertemporal dependency. The nature of the problem oftentimes causes the RL policy to converge to a poor-performing local optimum if learned directly. To overcome this, we design a two-stage curriculum in which the RL agent will learn generation control and load restoration decision under different scenarios progressively. Via curriculum learning, the trained RL controller is expected to achieve a better control performance, with critical loads restored as rapidly and reliably as possible. Using the IEEE 13-bus test system, we illustrate the performance of the RL controller trained by the proposed curriculum-based method.

curriculum learning↗

Restoring Critical Loads in Resilient Distribution Systems Using a Curriculum Learned Controller: Preprint

In this paper, we propose a curriculum learned reinforcement learning (RL) controller to facilitate distribution system critical load restoration (CLR), leveraging RL's fast online response and its outstanding optimal sequential control capability. Like many grid control problems, CLR is complicated due to the large control action space and renewable uncertainty in a heavily constrained non-linear environment with strong intertemporal dependency. The nature of the problem oftentimes causes the RL policy to converge to a poor-performing local optimum if learned directly. To overcome this, we design a two-stage curriculum in which the RL agent will learn generation control and load restoration decision under different scenarios progressively. Via curriculum learning, the trained RL controller is expected to achieve a better control performance, with critical loads restored as rapidly and reliably as possible. Using the IEEE 13-bus test system, we illustrate the performance of the RL controller trained by the proposed curriculum-based method.

61 RADIATION PROTECTION AND DOSIMETRY↗

Deadband Voltage Control and Power Buffering for Extreme Fast Charging Station

Voltage fluctuation is one of the most common challenges that electric vehicle charging station (EVCS) may introduce to the power grid. Local reactive power compensation (Q-compensation) capability of bi-directional electric vehicle (EV) chargers can mitigate the steady-state voltage violations caused by the EV charging itself or changes in the neighboring loads. Power buffering, using energy storage system (ESS), can be utilized to address the voltage transients (sags and swells) as a result of EV charging at the EVCS. To address PI controller’s ‘hunting’ issue, this paper proposes a Q-sign triggered deadband voltage control (V-control) method at the point of common coupling (PCC). In addition, to ensure the ramp rate of EV charging is within the allowable limits set forth by the grid code, a ramp rate control is proposed that uses the ESS as a ‘power buffer’. Lastly, different from most reported work in the literature where no explicit limit of the power electronic converters (PECs) is considered, this work considers a reasonable apparent power capacity limit of the PECs when achieving the V-control. This limit also affects the amount of active power that can be obtained from the grid, and subsequently may require ESS to function as ‘load sharing’ device to provide supplemental active power to satisfy EV load. A case study simulated in MATLAB (interfaced with PLECS) is presented to demonstrate the effectiveness of the proposed approaches for EVCS operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lifetime fatigue response due to wake steering on a pair of utility-scale wind turbines

Quantifying the impacts on turbine loads during wind farm control is an important consideration in assessing power production benefits. Wake steering controls aim to improve total wind farm performance by coordinating the control actions of individual turbines, wherein an upstream turbine is intentionally yawed at an offset angle from the measured wind direction. Consequently, this redirects its wake for improved power production and potentially reduces fatigue loads of the downstream turbines. This paper studies the lifetime fatigue loads associated with wake steering by using utility-scale wind turbine experimental data to conduct an analysis on a pair of wind turbines. This study was part of a large field experiment in which a group of five GE 1.5-MW SLE CWE turbines were selected as targets for conducting wake steering research. A standard loads instrumentation package and data acquisition system were installed on two turbines within the cluster to measure turbine fundamental loads. The time-series databases were used to calculate loads statistics as well as short-term and lifetime damage equivalent loads. Fatigue calculations followed the guidance in Annex H of the International Electrotechnical Commission standard 61400-1, Edition 4. Lifetime fatigue calculation results are presented in this analysis; three methods of assessing lifetime fatigue were used to determine percent difference for blade root moments, main shaft moments, main shaft torque, and tower top torque. For all three fatigue treatments, some components’ lifetime fatigue increases for the controlled turbine; however, the downwind turbine experienced a reduction in lifetime fatigue and combined effect for the turbine pair results in a reduction of fatigue when wake steering controls are applied.

17 WIND ENERGY↗

Optimized V1G and V2G Electric Vehicle Fleet Management and Grid Transaction at Marine Corps Air Station Miramar in San Diego, CA

The overall technical goal of the project was to demonstrate an all-electric bi-directional non-tactical fleet at Marine Corps Air Station (MCAS) Miramar that was integrated and controlled with other distributed energy resources (DERs) (i.e., PV, stationary battery, and building loads) to provide resilience to critical electric loads in the event of grid outages, to minimize charging costs, and to provide economic energy resources to electricity markets. In this project, the specific, technical objectives were: 1. Demonstrate that bi-directional electric vehicles can provide critical complementary services to fixed storage batteries in microgrid applications while performing function as non-tactical vehicles. 2. Demonstrate participation of bi-directional (V2G) and unidirectional (V1G) PEVs for demand management and minimization of charging costs. 3. Demonstrate integration of multiple DERs for grid service participation. US Marine Corps Air Station (MCAS) Miramar in San Diego was the site of this electric vehicle-to-microgrid-utility grid test and demonstration project. Existing microgrid assets in this study included (1) a public works building; (2) a 30-kW rooftop photovoltaic (PV) system and (3) a separate 250 kW carport PV system. In this project, six bi-directional V2G vans were located at the MCAS Miramar’s showcase building-scale microgrid to develop and test technical capabilities that V2G can provide in microgrid applications (e.g., cost reduction and resiliency). These resources provided aggregated demand management and simulated participation in current retail DR programs. The vehicles used in this demonstration were selected because they provided functionality that MCAS Miramar needed, 15 passenger transport and facilities work cargo carrying capacity, and bi-directional charging capability that the research project required. All vehicles in this study were manufactured and distributed by VIA Motors, Inc. There were six vehicles total and each was VIA’s VTRUX eREV V2G model, a modified General Motors Chevrolet 2500 2WD van. Three of the vans were configured as passenger vans and the other three were configured as cargo vans. Each van had an on-board bi-direcrtional inverter/charger, Bel Power Solutions model 350INVCHGT150-120-240-8G nominally rated at +/-15 kW. The VIA van’s charging connector follows the J1772 charging protocol. The bi-directional EVSEs demonstrated in this study were manufactured by Coritech, Inc. Each VGI-80-AC charging station enabled enhanced V2G charging capability to a Clipper Creek CS-100 charging module. The enhanced capabilities included ethernet communication following the SEP2.0 protocol with a distributed energy resource function set and an operator screen displaying real-time SOC, voltage, and current. The VGI-80-AC charging stations are classified as level 2 with a maximum current output of 80 A or effectively 19 kW. The VIA van’s onboard charger limited the charging and discharging power to 15 kW in each direction. A control computer was installed in the EWOC and connected to an existing monitor. The V2G control communication network was a completely stand-alone closed system that did not have any connection to any other networks on the base. A cybersecure remote communication connection was created with a cellular modem, firewall hardware, and a virtual private network configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Centralized and Decentralized Optimal Control of Variable Speed Heat Pumps

Utility service providers are often challenged with the synchronization of thermostatically controlled loads. Load synchronization, as a result of naturally occurring and demand-response events, has the potential to damage power distribution equipment. Because thermostatically controlled loads constitute most of the power consumed by the grid at any given time, the proper control of such devices can lead to significant energy savings and improved grid stability. The contribution of this paper is the development of an optimal control algorithm for commonly used variable speed heat pumps. By means of selective peer-to-peer communication, our control architecture allows for the regulation of home temperatures while simultaneously minimizing aggregate power consumption, and aggregate load volatility. An optimal centralized controller is also explored and compared against its decentralized counterpart.

30 DIRECT ENERGY CONVERSION↗

Highly Loaded Sulfur Cathode, Coated Separator and Gel Electrolyte for High Rate Li-Sulfur Batteries

As one of DOE Battery 500 Seedling projects, Cornell University and EIC Labs investigated and developed i) highly loaded sulfur cathodes (> 3 mg/cm 2 ), ii) hybrid separators, and iii) gel ceramic electrolytes (GCE) to mitigate the low rate capability, shuttling effect and limited cycle life in high performance Li-Sulfur batteries. Scalable nanomanufacturing processes such as air-controlled electrospray (ACES) and gas-assisted electrospinning (GAES) have been utilized to develop directly deposited electrodes and polymer/ceramic hybrid separators. First, in the development of highly loaded cathodes, alternating layers of sulfur impregnated mesoporous carbon and graphene were fabricated via ACES and the resulting layered cathodes and coated separators exhibit higher capacity and capacity retention (about 1,000 mAh/g capacity with less than 0.02% fade/cycles) than single layer cathode or cathode prepared by conventional slurry cast. Alternating layer approach via ACES has been applied to high loading systems (3 - 5 mg S/cm 2 ), demonstrating the potential to increase sulfur utilization and capacity retention. We have also incorporated iron oxides (Fe 3 O 4 ) into S/mesoporous carbon/graphene cathodes to enhance sulfur utilization and mitigation of polysulfide shuttling. and the effect of Fe 3 O 4 in mesoporous carbon and Gr is highly pronounced at high C rates of 1C and 2C cycling performance. To further improve the cathodes at high rates, graphene nanoribbons (GNR) which can promote ion transport were incorporated in the cathode, resulting in 550 mAh/g at 5C/5C rates. Hybrid Li-ion/Li-S cathodes has also been explored to better engage unreacted polysulfides during charge/discharge. S/LFP hybrid cathodes offer higher sulfur utilization and enhanced rate capability, as well as higher areal loading. This study suggests inclusion of iron phosphide (Fe2P) which can chemically interact with polysulfides can further enhance sulfur utilization and mitigation of soluble polysulfides at high rates. Secondly, in the development of hybrid separators, we first employed graphene coating on the commercial polyolefin separators, which exhibits higher capability, better capacity retention and enhanced rate capability. To improve the rate capability with enhanced safety features such as thermal stability and nonflammability, we developed polymer/ceramic hybrids based on thermally stable polyimide (PI) and room temperature curable ceramic precursors such as organopolysilazane (OPSZ) or polysilsesquioxanes (PSSQ), which exhibit no shrinkages up to 300 ºC and non-flammability. To improve mechanical properties and electrochemical stability, polybenzimidazole (PBI) and alumina have been incorporated in polymer/ceramic hybrid separator, replacing PI and OPSZ/PSSQ, respectively. Finally, the gel ceramic electrolyte (GCE) based on ceramic cross linkers have been applied to make Li-S cells even safer and also to mitigate the polysulfide shuttling further. The resulting gel ceramic electrolyte offers improved capacity retention and rate capability, and also effectively mitigates polysulfide shuttling which was also confirmed by modeling. Inclusion of high ion conducting additives into GCE together with polymer/ceramic hybrid separators exhibit the higher ionic conductivity than liquid electrolyte with commercial polyolefin separator. We demonstrated that the developed highly loaded sulfur cathodes, polymer/ceramic hybrid separators and gel ceramic electrolyte can effectively mitigate the low rate capability, shuttling effect and limited cycle life in high performance Li-Sulfur batteries with improved safety.

25 ENERGY STORAGE↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improved Control Strategy of Grid Interface for EV High-Power Dynamic Wireless Charging

This paper proposes a control strategy for the grid interface converter in high-power dynamic wireless charging system (DWCS) to address two issues on distribution network integration. Due to the unique pulsating load profile of DWCS, load transient response capability is critical for the grid interface to maintain the dc-bus voltage stable. Besides, the inherent unbalanced situation of distribution network would lead to 2nd-order oscillations on the dc-bus voltage, which would further affect the stable operation of the entire system. In this paper, the DWCS model is developed, and the relationship between the dc-bus voltage and the input/output power is analyzed. Based on the developed model, a control strategy based on direct power control is presented. Both simulation results and hardware-in-the-loop (HIL) results demonstrate that the proposed control strategy not only improves load transient response capability, but also eliminates the 2nd-order oscillations on the dc-bus voltage under imbalanced distribution network conditions.

Zeng, Rong↗

SolarPlus Optimizer: Integrated Control of Solar, Batteries, and Flexible Loads for Small Commercial Buildings

Building-level microgrids may be a key strategy to unlock the combined potential of flexible loads, renewable generation, and energy storage. However, few software options exist for integrated control of building loads and other distributed energy resources at this scale. The commercial software solutions on the market can force customers to adopt one particular ecosystem of products, thus limiting consumer choice. The SolarPlus Optimizer (SPO) is an open-source building-level microgrid control platform that uses Model Predictive Control to optimize both building loads and behind-the-meter energy storage to reduce energy bills and increase demand flexibility. This paper evaluates the capabilities of SPO in a small commercial building in Northern California under multiple electricity tariffs and demand response scenarios. Comparing SPO operation with an emulated battery and baseline operation employing a commercial optimization service, SPO reduced electricity bills by an estimated 7.3% in summer, 3.2% in spring, and 3.7% in winter. In a “load shape” scenario meant to counter the “duck curve”, SPO achieved 71% fewer violations from the load signal than the baseline control method. During a three hour long load shed event, SPO reduced cooling and refrigeration load by 38%. This research shows significant potential to provide load flexibility for building-level microgrids for this type of control systems. Finally, the paper discusses the future direction of research on open-source control systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗