At least 55 records · Page 3

Silver Ion Biocide Delivery System for Water Disinfection

U.S. space exploration missions have long considered returning to the Moon and exploration of Mars that challenge life support systems. For these long duration missions, there is interest in replacing the iodine water treatment system with ionic silver, a proven biocide. For long duration exploration missions, it is imperative that an effective biocide be used that prevents microbial growth, biofilm formation, and microbially induced corrosion in the water storage and distribution systems while minimizing logistical supply requirements associated with the biocide delivery system. Two biocide delivery systems have been developed that electrochemically produce silver ions for disinfecting water throughout the water storage and distribution system. One system uses a newly developed hybrid micro-filtration and ion-exchange membrane to produce an abundance of silver ions at the 1000 ppb level upstream in the water distribution system to prevent biofilm growth. This is followed by a downstream collection module that electrochemically removes these silver ions before the water is discharged. Another approach uses a membraneless reactor to produce a 1000 ppb silver ion concentration level that also has a mechanically driven electrode cleaning mechanism that removes oxide films ensuring long life operation. By maintaining a sufficiently high level of silver ions throughout the water storage and distribution system, biofilm formation is suppressed. This approach overcomes present concerns where spurious silver deposition occurs on the container and flow line surfaces thus lowering the silver ion concentration to unsatisfactory disinfection levels.

Slote, Benjamin M.↗

Investigation of Silver Biocide as a Disinfection Technology for Spacecraft-An Early Literature Review

An ideal spacecraft water disinfection system should prevent or control microbial growth, inhibit or prevent biofilm formation, and prevent microbial-induced corrosion. In addition, the selected biocide system should be chemically compatible with materials used in the water storage and distribution system, have minimal maintenance requirements, especially for long-duration missions, and should be safe for crew consumption at levels appropriate for biocidal control. Silver ion is a proven broad spectrum biocide. There has been an increased interest in the biocidal function of silver, both due to its potential to control biocide resistant species and due to advances in silver and nanosilver biocide technologies. NASA is considering silver as the future biocide for exploration over the iodine biocide system. In order to select and design a successful silver biocide delivery system to meet NASA's requirements, it is essential to understand the advantages and disadvantages of moving to a silver disinfection system. To enhance the knowledge base for the application of silver biocides in spacecraft water systems, this paper provides a first compilation of review data related to: (1) Silver as a biocide technology, (2) Options and concepts for silver biocide delivery, and (3) Silver biocide compatibility studies for spacecraft systems.

Li, Wenyan↗

Commercialization of microcavity plasma devices and arrays: Systems for VUV photolithography and nanopatterning, disinfection of drinking water and air, and biofilm deactivation for medical therapeutics

Abstract A little more than two decades after the introduction of the first microcavity plasma devices, a growing body of commercial products based on the remarkable properties of these low‐temperature, atmospheric plasmas is now available. Following a brief review of early microplasma lamp development, this article describes microplasma‐based devices and systems currently being manufactured for applications in photolithography, photopatterning, and other nanofabrication processes, such as atomic layer deposition, spectroscopic identification and analysis of materials (including wide bandgap crystals), the disinfection of drinking water in off‐grid communities, deactivating COVID‐19 and other pathogens in air and on surfaces in public spaces, and vacuum ultraviolet lamps for driving atomic clocks. The microplasma‐based treatment of otitis media in the human ear will also be discussed.

42 ENGINEERING↗

Flume and single-pass washing systems for fresh-cut produce processing: Disinfection by-products evaluation

Free chlorine is widely used in fresh-cut produce washing to minimize microbial cross-contamination, but its application can also lead to the formation of harmful disinfection byproducts (DBPs). This study compared DBPs in process water and washed produce during commercial operation. Samples of shredded lettuce and diced cabbages washed in chlorinated water in the traditional double-flume wash and novel immersion-free single-pass wash systems were collected at multiple time points and locations from the processing lines. A suite of 33 conventional and emerging DBPs, including 4 trihalomethanes (THMs), 9 haloacetic acids (HAAs), 9 nitrogenous DBPs (N-DBPs), and 11 carbonaceous DBPs (C-DBPs), were investigated. Overall, N-DBPs and HAAs dominated the concentration of detected DBPs. Wash water in the flumes contained 7–111 folds higher DBP levels compared to that in the single-pass system, with the abundance of DBPs following the order of N-DBPs > HAAs > C-DBPs > THMs. DBPs were detected on washed produce, presenting primarily in the forms of N-DBPs and HAAs followed by C-DBPs and THMs. While higher levels of DBPs were detected in flume-washed produce, the final potable water rinse significantly reduced the DBP concentration in these products. The concentrations of THMs and HAAs on these washed products were used to estimate potential exposure via consumption of fresh-cut produce and the levels were below the daily allowable exposure for drinking water standard established by the U.S. Environmental Protection Agency. The detected high concentration and potential toxicity of N-DBPs indicate the need for further research. Here, the findings of this study advance the understanding of the formation and removal of DBPs during wash processes, and identify additional research opportunities for further reduction in DBPs and food safety improvement.

59 BASIC BIOLOGICAL SCIENCES↗

Templated Mesoporous Silica Outer Shell for Controlled Silver Release of a Magnetically Recoverable and Reusable Nanocomposite for Water Disinfection

Here, we encapsulated Fe 3 O 4 @SiO 2 @Ag (MS-Ag), a bifunctional magnetic silver core–shell structure, with an outer mesoporous silica (mS) shell to form an Fe 3 O 4 @SiO 2 @ 2 Ag@mSiO 2 (MS-Ag-mS) nanocomposite using a cationic CTAB (cetyltrimethylammonium bromide) micelle templating strategy. The mS shell acts as protection to slow down the oxidation and detachment of the AgNPs and incorporates channels to control the release of antimicrobial Ag + ions. Results of TEM, STEM, HRSEM, EDS, BET, and FTIR showed the successful formation of the mS shells on MS-Ag aggregates 50–400 nm in size with highly uniform pores ~4 nm in diameter that were separated by silica walls ~2 nm thick. Additionally, the mS shell thickness was tuned to demonstrate controlled Ag + release; an increase in shell thickness resulted in an increased path length required for Ag + ions to travel out of the shell, reducing MS-Ag-mS’ ability to inhibit E. coli growth as illustrated by the inhibition zone results. Through a shaking test, the MS-Ag-mS nanocomposite was shown to eradicate 99.99+% of a suspension of E. coli at 1 × 10 6 CFU/mL with a silver release of less than 0.1 ppb, well under the EPA recommendation of 0.1 ppm. This high biocidal efficiency with minimal silver leach is ascribed to the nanocomposite’s mS shell surface characteristics, including having hydroxyl groups and possessing a high degree of structural periodicity at the nanoscale or “smoothness” that encourages association with bacteria and retains high Ag + concentration on its surface and in its close proximity. Furthermore, the nanocomposite demonstrated consistent antimicrobial performance and silver release levels over multiple repeated uses (after being recovered magnetically because of the oxidation-resistant silica-coated magnetic Fe 3 O 4 core). It also proved effective at killing all microbes from Long Island Sound surface water. The described MS-Ag-mS nanocomposite is highly synergistic, easy to prepare, and readily recoverable and reusable and offers structural tunability affecting the bioavailability of Ag + , making it excellent for water disinfection that will find wide applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Magnetically Recoverable and Reusable Titanium Dioxide Nanocomposite for Water Disinfection

A bifunctional magnetic Fe3O4@SiO2@TiO2 or MS-TiO2 antimicrobial nanocomposite was prepared based on simple sol-gel methods with common equipment and chemicals. Reaction pH was found to influence the TiO2 upload in the nanocomposite. The alkaline condition produced the greatest TiO2 upload, while the acidic condition the least. Annealing at 300 °C turned the as-synthesized amorphous TiO2 into one with high content of anatase, the most photoactive form of TiO2. Irradiated by 365 nm UV light, a sample of 30 mg/mL of annealed nanocomposite containing 12.6 wt.% Ti was shown to be able to completely eradicate 104 CFU/mL of the laboratory-grown E. coli within 25 min, 25 min faster than the control when the 365 nm UV light was employed alone. The nanocomposite demonstrated consistent antimicrobial performance over repeated uses and was easily recoverable magnetically due to its high magnetization value (33 emu/g). Additionally, it was shown to reduce the bacterial count in a real surface water sample containing 500–5000 CFU/mL of different microbes by 62 ± 3% within 30 min. The irradiating 365 nm UV light alone was found to have generated little biocidal effect on this surface water sample. The nanocomposite is promising to serve as an effective, safe, and eco-friendly antimicrobial agent, especially for surface water disinfection.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Numerical simulation of iodine speciation in relation to water disinfection aboard manned spacecraft I. Equilibria

Elemental iodine (I2) is currently used as the drinking water disinfectant aboard the Shuttle Orbiter and will also be incorporated into the water recovery and distribution system for the International Space Station Alpha. Controlled release of I2 is achieved using the Microbial Check Valve (MCV), a flow-through device containing an iodinated polymer which imparts a bacteriostatic residual concentration of approximately 2mg/L to the aqueous stream. During regeneration of MCV canisters, I2 concentrations of approximately 300 mg/L are used. Dissolved iodine undergoes a series of hydrolytic disproportionation and related reactions which result in the formation of an array of inorganic species including: I-, I3-, HOI, OI-, IO3-, HIO3, I2OH-, I2O(-2), and H2OI+. Numerical estimation of the steady-state distribution of inorganic iodine containing species in pure water at 25 degrees C has been achieved by simultaneous solution of the multiple equilibrium expressions as a function of pH. The results are reported herein.

NASA Discipline Environmental Health↗

Self-Disinfecting PPE Fabric [Factsheet]

Green Theme Technologies Inc. developed a chemical finishing technology that uses a high pressure, water-free, thermally triggered polymerization process to produce a thin conformal polymer coating around fabric fibers. This process can be used to embed selective, disinfectant chemicals to provide an anti-microbial, anti-viral finish to fabrics. In the face of COVID-19, the company hopes this process produces a permanent, laundry-durable, anti-pathogenic finish. Essentially, creating regenerative and reusable PPE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Native Microalgae-Bacteria Consortia: A Sustainable Approach for Effective Urban Wastewater Bioremediation and Disinfection

Urban wastewater is a significant by-product of human activities. Conventional urban wastewater treatment plants have limitations in their treatment, mainly concerning the low removal efficiency of conventional and emerging contaminants. Discharged wastewater also contains harmful microorganisms, posing risks to public health, especially by spreading antibiotic-resistant bacteria and genes. Therefore, this study assesses the potential of a native microalgae-bacteria system (MBS) for urban wastewater bioremediation and disinfection, targeting NH4+-N and PO43−-P removal, coliform reduction, and antibiotic resistance gene mitigation. The MBS showed promising results, including a high specific growth rate (0.651 ± 0.155 d−1) and a significant average removal rate of NH4+-N and PO43−-P (9.05 ± 1.24 mg L−1 d−1 and 0.79 ± 0.06 mg L−1 d−1, respectively). Microalgae-induced pH increase rapidly reduces coliforms (r > 0.9), including Escherichia coli, within 3 to 6 days. Notably, the prevalence of intI1 and the antibiotic resistance genes sul1 and blaTEM are significantly diminished, presenting the MBS as a sustainable approach for tertiary wastewater treatment to combat eutrophication and reduce waterborne disease risks and antibiotic resistance spread.

Sousa, Joana F.↗

Improved method of using paraformaldehyde as a disinfectant

Paraformaldehyde decreases required enclosed compartment disinfectant time and temperature by vaporizing powdered material from water slurry. Fire and explosion hazard at lower temperature is reduced. Total mixture evaporation occurs at plate temperature of approximately 167 deg K below that required to vaporize powdered material.

Milner, J. F.↗

Medical effects of iodine disinfection products in spacecraft water

Various iodination products (IDPs), including iodinated and iodine-induced new compounds, will be present in the iodine-disinfected water that is expected to be used by crews on the NASA Space Station and on long duration missions. The metabolic intermediaries created by such a process may be more important to crew health than the parent IDPs, and reclamation and recycling may be expected to produce additional products. These medical effects may be expressed in crews as hypersensitivity, allergic, acute toxic, and chronic toxic reactions, as well as modifications of immune system response.

Sauer, Richard L.↗

Electrochemical control of iodine disinfectant for space transportation system and space station potable water

An electrochemical microbial check valve method (EC-MCV) for controlling the iodine disinfectant in potable water (PW) for NASA's space operations was proposed. The factors affecting the design and performance of the unit were analyzed. This showed that it would be feasible to construct a recyclable unit in a small volume that will operate in either an iodine removal or addition mode. The EC-MCV should remove active iodine species rapidly from PW, but the rapid delivery rates at end-use may make complete removal of excess I(-) difficult under some conditions. Its performace change with AgI buildup needs to be investigated, as this controls the time for recycling the unit. The EC-MCV has advantages over the passive microbial check valve (MCV) method currently in use, as it would allow precise control of the I2 level and would not introduce excess I(-) to the water. The presence of oxygen in the EC-MCV needs to be investigated as it could affect the efficiency of I2 addition and excess I(-) removal.

Geer, Richard D.↗

Disinfecting Filters For Recirculated Air

Simple treatment disinfects air filters by killing bacteria, algae, fungi, mycobacteria, viruses, spores, and any other micro-organisms filters might harbor. Concept applied to reusable stainless-steel wire mesh filters and disposable air filters. Treatment used on filters in air-circulation systems in spacecraft, airplanes, other vehicles, and buildings to help prevent spread of colds, sore throats, and more-serious illnesses.

Pilichi, Carmine A.↗

Development of static system procedures to study aquatic biofilms and their responses to disinfection and invading species

The microbial ecology facility in the Analytical and Physical Chemistry Branch at Marshall Space Flight Center is tasked with anticipation of potential microbial problems (and opportunities to exploit microorganisms) which may occur in partially closed systems such as space station/vehicles habitats and in water reclamation systems therein, with particular emphasis on the degradation of materials. Within this context, procedures for microbial biofilm research are being developed. Reported here is the development of static system procedures to study aquatic biofilms and their responses to disinfection and invading species. Preliminary investigations have been completed. As procedures are refined, it will be possible to focus more closely on the elucidation of biofilm phenomena.

Smithers, G. A.↗

Disinfection susceptibility of waterborne pseudomonads and Legionellae under simulated space vehicle conditions

The sensitivity of waterborne bacteria from iodinated systems to iodine is examined with particular attention to the recovery of the organisms. The use of iodine as a disinfectant for space-vehicle water is described, and references are made to studies of iodine sensitivity and the relationship between growth rate and iodine sensitivity. Growth following iodination is discussed, and bacterial responses to nutrient restriction are examined for both P aeruginosa and Legionella pneumophila. The low level of organic nutrients in spacecraft water allows the selection for bacteria that are less sensitive to halogens. The formation of biofilms within the water-treatment system enhances bacterial resistance to iodine, and in the case of high-quality water it is shown that sublethal doses of iodine can stimulate bacterial growth. Water treatment should therefore be based on antecedent growth conditions, nutrient limitation, biofilm formation, and ambient selective pressures.

Mcfeters, Gordon A.↗

Regenerable Iodine Water-Disinfection System

Iodinated resin bed for disinfecting water regenerated to extend useful life. Water flows through regeneration bed of crystalline iodine during regeneration. At other times, flow diverted around regeneration bed. Although regeneration cycle manually controlled readily automated to start and stop according to signals from concentration sensors. Further benefit of regeneration is bed provides highly concentrated biocide source when needed. Concentrated biocide used to superiodinate system after contamination from routine maintenance or unexpected introduction of large concentration of microbes.

Sauer, Richard L.↗

Regenerable Iodine Water-Disinfection System

Iodinated resin bed for disinfecting water regenerated to extend its useful life. Water flows through regeneration bed of crystalline iodine during regeneration. At other times, flow diverted around regeneration bed. Although regeneration cycle was manually controlled in demonstration, readily automated to start and stop according to signals and stop according to signals from concentration sensors. Further benefit of regeneration is that regeneration bed provides highly concentrated biocide source (200 mg/L) when needed. Concentrated biocide used to superiodinate system after contamination from routine maintenance or unexpected introduction of large concentration of microbes.

Sauer, Richard L.↗

Biological monitoring of iodine, a water disinfectant for long-term space missions

In order to establish guidelines for exposure of astronauts to iodine, used as a water disinfectant in space, we studied the usefulness of hair, saliva, and urine for biological monitoring in humans and in the human hair/nude mouse model. The monitoring of iodine in patients that received 150 mCi of Na131I (carrier-free) showed similar patterns of elimination for blood, saliva, and urine. The mean correlation coefficient (r) between iodine elimination for blood/saliva was 0.99, for blood/urine, 0.95, and for saliva/urine, 0.97. The absolute value of iodine concentrations in urine revealed marked variability, which was corrected by adjusting for creatinine levels. The autoradiographic studies of human hair demonstrated that iodine is rapidly incorporated into external layers of the hair root and can be removed easily during washing. These data were confirmed after iodine exposure using the human hair/nude mouse model. Hair does not provide satisfactory information about exposure due to unstable incorporation of iodine. The most useful medium for biological monitoring of astronauts exposed to high doses of iodine in drinking water is urine, when adjusted for creatinine, and saliva, if quantitative evaluation of flow rate is provided.