Application of distributed system concepts to analysis of bending vibration.
Distributed parameter transmission matrix analysis of bending vibrations of nonuniform elastic beam
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Distributed parameter transmission matrix analysis of bending vibrations of nonuniform elastic beam
Integration of distributed energy resources (DER) such as photovoltaics, electric vehicles (EVs) and battery energy storage systems (BESS) is expected to rapidly increase in distribution systems in India. These grid edge resources can have adverse impacts on the grid and can provide additional revenue streams as well. To mitigate these impacts distribution planning and analysis is required. So this paper presents a framework which can be used to complete all steps involved in distribution planning and analysis. This framework uses data in the same format as is readily available with Indian utilities and processes it to generate detailed feeder models and loading profiles. This framework already includes multiple DER use cases such as peak shaving for BESS and EV demand modelling and can be easily extended to simulate a number of additional use cases. All of these use cases can be simulated in parallel for multi-year time series simulations using an integrated command line interface. A suit of grid readiness metrics are then evaluated for each simulation to determine required network upgrades and associated costs.
Global sensitivity analysis (GSA) of distribution systems with respect to stochastic PV and load variations plays an important role in designing optimal voltage control schemes. This paper proposes a data-driven framework for GSA of distribution systems. In particular, two representative surrogate modeling-based approaches are developed, including the traditional Gaussian process-based and the analysis of variance (ANOVA) kernel ones. The key idea is to develop a surrogate model that captures the hidden global relationship between voltage and real and reactive power injections from the historical data. With the surrogate model, the Sobol indices can be conveniently calculated through either the sampling-based method or the analytical method to assess the global sensitivity of voltage to variations of PV and load power injections. The sampling-based method approximates the Sobol indices using Monte Carlo simulations while the analytical method calculates them by resorting to the ANOVA expansion framework. Comparison results with other model-based GSA methods on the unbalanced three-phase IEEE 37-bus and 123-bus distribution systems show that the proposed framework can achieve much higher computational efficiency with negligible loss of accuracy. The results on a real 240-node distribution system using actual smart meter data further validate the feasibility and scalability of the proposed framework.
The objective of this proposal is to develop an integrated and distributed analysis and display software system which can be applied to all areas of the Earth System Science to study numerical model and earth observational data from storm to global scale. This system will be designed to be easy to use, portable, flexible and easily extensible and to adhere to current and emerging standards whenever possible. It will provide an environment for visualization of the massive amounts of data generated from satellites and other observational field measurements and from model simulations during or after their execution. Two- and three-dimensional animation will also be provided. This system will be based on a widely used software package from NASA called GEMPAK and prototype software for three dimensional interactive displays built at NCSA. The underlying foundation of the system will be a set of software libraries which can be distributed across a UNIX based supercomputer and workstations.
The objective of this proposal is to develop an integrated and distributed analysis and display software system which can be applied to all areas of the Earth System Science to study numerical model and earth observational data from storm to global scale. This system will be designed to be easy to use, portable, flexible and easily extensible and designed to adhere to current and emerging standards whenever possible. It will provide an environment for visualization of the massive amounts of data generated from satellites and other observational field measurements and from model simulations during or after their execution. Two- and three-dimensional animation will also be provided. This system will be based on a widely used software package from NASA called GEMPAK and prototype software for three-dimensional interactive displays built at NCSA. The underlying foundation of the system will be a set of software libraries which can be distributed across a UNIX based supercomputer and workstations.
Integration of distributed energy resources (DER) such as photovoltaics, electric vehicles (EVs) and battery energy storage systems (BESS) is expected to rapidly increase in distribution systems in India. These grid edge resources can have adverse impacts on the grid and can provide additional revenue streams as well. To mitigate these impacts distribution planning and analysis is required. So this paper presents a framework which can be used to complete all steps involved in distribution planning and analysis. This framework uses data in the same format as is readily available with Indian utilities and processes it to generate detailed feeder models and loading profiles. This framework already includes multiple DER use cases such as peak shaving for BESS and EV demand modelling and can be easily extended to simulate a number of additional use cases. All of these use cases can be simulated in parallel for multi-year time series simulations using an integrated command line interface. A suit of grid readiness metrics are then evaluated for each simulation to determine required network upgrades and associated costs.
This work presents a review of open-source electric power transmission and distribution systems analysis tools suitable for use by industry professionals and academic researchers. Due to the high complexity of the electric grid, there exist numerous tools and extensive research pertaining to nearly every aspect of the design, operation, and control of transmission and distribution networks. In addition to the commercial tools, a wide range of free, open-source tools, models, and data usable by the scientific community for related research have been developed by different organizations, including both international and US universities and national laboratories. However, due to the absence of a catalog of available tools, models and data, researchers often lack a knowledge of existing capabilities and may develop duplicative software and tools. Increasing awareness of these available resources seeks to accelerate their broader use, leading to more efficient and standardized grid analysis. This review paper (which is part of a larger survey effort that studied over 400 tools in the transmission, distribution, buildings, and electric vehicles space) outlines selected open-source resources that have been developed in power transmission and distribution systems research. It is anticipated that this work can serve as a guide for industry and academic researchers alike, ensuring that research efforts are well-channeled.
A brief analysis is made of the hub and spoke air freight distribution system which would employ less than 15 hub centers world wide with very large advanced distributed-load freighters providing the line-haul delivery between hubs. This system is compared to a more conventional network using conventionally-designed long-haul freighters which travel between numerous major airports. The analysis calculates all of the transportation costs, including handling charges and pickup and delivery costs. The results show that the economics of the hub/spoke system are severely compromised by the extensive use of feeder aircraft to deliver cargo into and from the large freighter terminals. Not only are the higher costs for the smaller feeder airplanes disadvantageous, but their use implies an additional exchange of cargo between modes compared to truck delivery. The conventional system uses far fewer feeder airplanes, and in many cases, none at all. When feeder aircraft are eliminated from the hub/spoke system, however, that system is universally more economical than any conventional system employing smaller line-haul aircraft.
With the introduction of higher levels of renewables and demand response programs, traditional deterministic power system tools fall short of expectations. Probabilistic load flow (PLF) takes into account the inconsistency or the unknown loads, and generation in the fundamental load flow analysis. This study proposes a PLF solution for both balanced and unbalanced, radial and weakly meshed networks without explicitly using the Y ‐bus matrix. It allows for discrete probability density functions as input variables without having to assume a predefined distribution. The nodal voltages and the power flows can be calculated independently from one another. The proposed method is applied to the IEEE 123 Node Test Feeder and the IEEE 13 Node Test Feeder in both its original radial configuration and a modified mesh configuration, including a load replaced with a wind turbine. The results are validated by comparison of the proposed method's solutions to those obtained using cumulants and Monte Carlo simulation. The proposed PLF method provides an accurate and practical way for finding the solution to stochastic problems occurring in power distribution systems allowing for real‐system data to be analysed.
In this thesis, an observability analysis framework is proposed for power distribution systems. The framework analyzes the sufficiency of the available measurements for monitoring the system. In the areas of the network where sufficient sensors have been deployed, the complex voltage at the nodes may be estimated. The framework also provides a metric that quantifies the accuracy of these voltage estimates. Due to the cost of sensors and the size of distribution systems, it is frequently the case that the available measurements are insufficient for complete observability of the system. In this thesis, the author proposes the use of Correlational Measurements (CMs) for improving distribution system observability by leveraging correlation between loads and between Distributed Energy Resources (DERs). Load correlation due to class-residential, commercial, industrial, etc.- is captured via correlational load measurements, the first type of CM. Injection correlation of DERs-such as wind turbines located in proximity-is captured via correlational DER measurements, the second type of CM. This thesis presents the CM formulation and derives modified node voltage and branch current based state estimators (NVSE and BCSE) accommodating CMs. Additionally, this thesis contains an on-line parameter estimation scheme for CMs that improves the accuracy of state estimates over time. The observability analysis framework with CMs is demonstrated through simulations on the IEEE 123 Node Distribution Test Feeder. It is shown that the introduction of CMs leads to improved observability of the system with only a 0.7% decrease in state estimation accuracy for NVSE and a 0.5% increase in state estimation accuracy for BCSE.
In this paper, we provide a time-series distribution test system. This test system is a fully observable distribution grid in Midwest U.S. with smart meters (SM) installed at all end users. Our goal is to share a real U.S. distribution grid model without modification. This grid model is comprehensive and representative since it consists of both overhead lines and underground cables, and it has standard distribution grid components such as capacitor banks, line switches, substation transformers with load tap changer and secondary distribution transformers. An important uniqueness of this grid model is it has one-year smart meter measurements at all nodes, thus bridging the gap between existing test feeders and quasi-static time-series based distribution system analysis.
Because it avoids the high currents in a parallel loaded capacitor, the cascaded Schwarz converter should offer better component utilization than converters with sinusoidal output voltages. The circuit is relatively easy to protect, and it provides a predictable trapezoidal voltage waveform that should be satisfactory for 20-kHz distribution systems. Analysis of the system is enhanced by plotting curves of normalized variables vs. gamma(1), where gamma(1) is proportional to the variable frequency of the first stage. Light-load operation is greatly improved by the addition of a power recycling rectifier bridge that is back biased at medium to heavy loads. Operation has been verified on a 2.5-kW circuit that uses input and output voltages in the same range as those anticipated for certain future spacecraft power systems.
An understanding of the nature of the adverse effects that could be associated with contamination events in water distribution systems is necessary for carrying out vulnerability analyses and designing contamination warning systems. This study examines the adverse effects of contamination events using models for 12 actual water systems that serve populations ranging from about 104 to over 106 persons. The measure of adverse effects that we use is the number of people who are exposed to a contaminant above some dose level due to ingestion of contaminated tap water. For this study the number of such people defines the impact associated with an event. We consider a wide range of dose levels in order to accommodate a wide range of potential contaminants. For a particular contaminant, dose level can be related to a health effects level. For example, a dose level could correspond to the median lethal dose, i.e., the dose that would be fatal to 50% of the exposed population. Highly toxic contaminants may be associated with a particular response at a very low dose level, whereas contaminants with low toxicity may only be associated with the same response at a much higher dose level. This report focuses on the sensitivity of impacts to five factors that either define the nature of a contamination event or involve assumptions that are used in assessing exposure to the contaminant: (1) duration of contaminant injection, (2) time of contaminant injection, (3) quantity or mass of contaminant injected, (4) population distribution in the water distribution system, and (5) the ingestion pattern of the potentially exposed population. For each of these factors, the sensitivities of impacts to injection location and contaminant toxicity are also examined. For all the factors considered, sensitivity tends to increase with dose level (i.e., decreasing toxicity) of the contaminant, with considerable inter-network variability. With the exception of the population distribution (factor 4 above), sensitivity to the various factors tends to be highest at lower impact levels (e.g., impacts below the 80th percentile). Conversely, for the population distribution factor, sensitivity is lowest at the lower impact levels. For injection duration, impacts generally are higher for longer duration injections. Definite patterns are present in the sensitivity of impacts to injection time, but these vary substantially across the networks. As would be expected, impacts are larger for larger mass injections, but the sensitivity can vary dramatically depending on dose level and the network. Estimated impacts can be sensitive to assumptions about how population is distributed in a network, particularly at high impact levels and high dose levels, again with considerable variability across networks. Finally, impacts can be sensitive to assumptions about ingestion patterns in the potentially exposed population, with sensitivities varying across networks and tending to be highest for high dose levels. When considered in combination with the other factors (but not including the ingestion model used), impacts at low dose levels (levels at which the effects of highly toxic contaminants can be significant) are most sensitive to injection duration. Similarly, when considered in combination, impacts at higher dose levels (levels required for significant effects from contaminants with low toxicity) are most sensitive to injection mass. At low dose levels, for a likely range in injection masses, impacts are not particularly sensitive to injection mass. The influence of the various factors on the location of high percentile injection locations can be as important or more important than their influence on the magnitudes of impacts. In addition, the choice of contaminant has a major influence on which nodes are high impact injection locations. The sharing (overlap) of the same high-percentile injection nodes for different values of a factor can vary substantially by contaminant and impact level (percentile of impact). Overlap tends to decrease with decreasing toxicity of the contaminant and increasing impact level for all the factors considered, with considerable variability among the networks. Our results demonstrate the great variability in the impacts and the sensitivity of impacts to various factors that can occur in different water systems during a contamination event. Although definite patterns exist in the nature and magnitude of impacts and sensitivities for the diverse set of water systems examined, these results also show that substantial inter-network variability limits the ability to predict or extrapolate these results to other systems. Therefore, although water systems do exhibit some similarities in the magnitude and pattern of impacts during contamination events, each individual water system should be treated as unique.
This paper proposes a multi-fidelity learning approach for distribution voltage probabilistic analysis with high penetration of PVs. Unlike the existing machine learning-based approaches that require a large number of high fidelity data to achieve satisfactory results, our approach strategically leverage massive low fidelity data from inaccurate model simulations and limited high fidelity historical data. The key idea is to use low-fidelity data to establish an initial model and then the high-fidelity data to calibrate and correct the constructed low-fidelity model. This allows us to fuse low- and high-fidelity data, yielding a high fidelity prediction model. Results obtained from a realistic feeder in US with 80% penetration of PVs show that the proposed approach can achieve a similar accuracy to the one with a large number of high fidelity data. This significantly highlights the advantages of the proposed method as compared to existing data-hungry machine learning methods. Different levels of fidelity data and their impacts are also investigated.
Understanding the impact of extreme events on people's ability to access energy is crucial for designing resilient energy systems. In the event of a disaster, damage to the electric system and related infrastructure (e.g., downed power lines, flooded equipment, hacked communication systems, damaged roads, etc.) can impact people's access to critical services, including not just electricity but also shelter, food, healthcare, and more. There is a key need to understand such impacts better and evaluate options to improve energy resilience. The Energy Resilience Analysis for Electric Distribution Systems (ERAD) tool is a free and open-source software package designed to help researchers and decision-makers analyze and improve energy system resilience.
In this letter, a simplified voltage sensitivity analysis technique that can provide accurate estimates of voltage change across the network for a given change in bus power injections in a three-phase unbalanced distribution network is proposed. This technique is derived from the first-order approximation of the Neumann series, which allows maintaining the accuracy of the solution while the computational effort is reduced. Here, the proposed technique is tested on a 559-bus unbalanced distribution system with multiple distributed generation resources. The results show that the average error in the voltage estimates with the proposed method is not more than 0.3% with the execution time of similar order relative to the state-of-the-art sensitivity analysis methods.
As inverter-based, distributed energy resources (DERs) and variable loads continue to proliferate across distribution systems, it is increasingly important to understand their impacts on system stability and reliability. However, most commercially available simulation tools for distribution planning primarily focus on steady-state and quasi-steady state analysis, offering limited capabilities to study transient and dynamic behaviors.
A simulation model of the NASA Huntsville Operational Support Center (HOSC) was developed. This simulation model emulates the HYPERchannel Local Area Network (LAN) that ties together the various computers of HOSC. The HOSC system is a large installation of mainframe computers such as the Perkin Elmer 3200 series and the Dec VAX series. A series of six simulation exercises of the HOSC model is described using data sets provided by NASA. The analytical analysis of the ETHERNET LAN and the video terminals (VTs) distribution system are presented. An interface analysis of the smart terminal network model which allows the data flow requirements due to VTs on the ETHERNET LAN to be estimated, is presented.