Search NASA⌕ Search

SEARCH · Search NASA

Results for “divertors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Interpretive modeling of tungsten divertor leakage during experiments with neon gas seeding

Abstract Many existing and future tokamaks with tungsten divertors operate, or will operate, with low- Z impurity seeding, but the direct effect of these seeded impurities on tungsten Scrape-off-Layer (SOL) transport has not been explored in detail. This paper reports on a DIII-D experiment designed to test how tungsten divertor leakage from the Small-Angle Slot V-Shaped, tungsten-coated divertor is impacted by neon seeding at a variety of injection rates and poloidal injection locations. Measurements from the experiment show an inverse relationship between the neon injection rate and the tungsten core penetration factor. Interpretive modeling is performed with a combination of the SOLPS-ITER and DIVIMP codes to assess the underlying tungsten behavior. The modeling results show that the reduction in tungsten divertor leakage is driven by both an increase in the divertor collisionality as well as a reduction in the ion temperature gradient near the divertor target. Collisions between low- Z impurities and tungsten impurities are found to have a significant impact on the tungsten SOL transport, such that ignoring the low- Z impurity collisional effects on the tungsten transport can result in an overestimate of the divertor leakage by an order-of-magnitude. Given the importance of these localized interactions, neon seeding from the closed, slot-like divertor has a clear advantage in being able to reduce tungsten divertor leakage without the high levels of neon core contamination that occur when seeding from other poloidal locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active Divertor Heat Flux Control using Impurity Powder Dropper

Divertor plasma-facing components (PFCs) in a tokamak are typically designed to withstand average steady-state heat loads of about 5–10 MW/m 2 , a limit that applies to both solid and liquid lithium (LL) PFCs. Exceeding these design values can result in surface damage to tungsten PFCs or excessive lithium (Li) evaporation in liquid lithium divertor (LLD) PFCs. Since exceeding the divertor heat load limits has serious consequences, it is therefore prudent to develop a tool to reduce the divertor heat load and bring the heat load to within the design limit without affecting the plasma performance. Active low Z impurity injection such as Li has been suggested as a potential solution to mitigate excess heat flux as suggested previously, given that non-coronal radiation can be quite large ~ 20–30 MJ per mole of injected Li. Li is considered desirable for reducing the edge neutral recycling helping to improve plasma energy confinement. In this paper, we model the Impurity Power Dropper (IPD) to investigate its potential of divertor heat flux control. The IPD is typically located at the top of the tokamak device and uses a vertical drift tube of a few meters. In the 2 m drift tube case, the IPD powder is accelerated to ~ 6 m/sec before reaching the plasma with the upper divertor configuration, matching the condition for the in-board side pellet injection case. By modeling the IPD geometry we determined the IPD powder deposition profile, and thus the non-coronal radiation and ionization profiles in time as well. From the enhanced radiation power loss, it is therefore possible to reduce the divertor heat load using the divertor simulation code. In conclusion, the IPD divertor heat flux control can be tested in the facilities with IPD including ST-40, DIII-D, EAST, WEST and NSTX-U.

Active lithium injection↗

Assessment of the burning-plasma operational space in ITER by using a control-oriented core-SOL-divertor model

In future tokamaks, the control of burning plasmas will require careful regulation of the plasma density and temperature. Along with the design of effective burn-control systems, understanding how the fusion power varies in the density-temperature space is vital for the operation of fusion power plants. Here in this work, the steady-state operational space of ITER is studied using a control-oriented core-plasma model coupled to a two-point model of the scrape-off-layer (SOL) and divertor regions. The two models are coupled through the exchange of input-output parameters. The deuterium and tritium recycling from the wall are output parameters of the SOL-divertor model that are used as input parameters in the core-plasma density balance. Furthermore, the separatrix temperature, which is an output parameter of the SOL-divertor model, is incorporated into the radial core-plasma temperature profiles. Therefore, the temperature-dependent power balance of the plasma core is intimately linked to the SOL-divertor model. Both the power entering the SOL from the core, as determined by the core-plasma power balance, and the separatrix density, as dictated by the core-plasma density balance, are input parameters to the SOL-divertor model. They are control knobs in the SOL-divertor model that can be regulated using the core-plasma actuators: auxiliary power and pellet injection. There are various operational limitations, such as the saturation of the aforementioned actuators, that will prevent ITER from accessing certain high-fusion plasma regimes. The achievable tritium concentration in the fueling lines and the maximum sustainable heat load on the divertor will impose further restrictions. By accounting for these limitations, the ITER operational space is computed based on the coupled core-SOL-divertor model and visualized using Plasma Operation Contour (POPCON) plots that map performance metrics, such as the fusion to auxiliary power ratio, over the density-temperature space. Comparisons are drawn between plasmas with different recycling, confinement, and SOL-divertor conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First snowflake divertor experiments in MAST-U tokamak

First snowflake (SF) divertor experiments in the MAST-U tokamak demonstrated steady-state snowflake-plus divertor configurations in 450 kA ohmic L-mode plasmas. The SF divertor configuration features a second poloidal field (PF) null in the divertor region close by or overlapping with the main X-point. The resulting low PF region and two additional divertor legs (strike points) may lead to additional power and particle flux sharing via a hypothesized convective cell, and increased plasma-wetted area and radiation. The free-boundary Grad–Shafranov equilibrium code FIESTA was used to design SF configurations with several inter-null distances and orientations. In the experiment, the SF configurations with inter-null distances 0.13–0.20 m and lasting 0.2–0.3 s were obtained. Parallel connection lengths between the midplane and the outer strike point in the SF configurations (evaluated at field lines 1–2 mm from the separatrix in the midplane) were 25–30 m, higher than in the standard divertor (20–25 m) or the Super-X divertor (25 m). Diagnostic measurements highlighted salient SF features. The infra-red video bolometer diagnostic showed that the radiated power peaking in the PF null region was not as pronounces as in the standard divertor. Divertor ion fluxes measured by target Langmuir probes showed increased ion flux in the plate region where a secondary SF strike point landed, concomitantly with the SF formation. These measurements may suggest that some particle and heat redistribution was taking place in the convective SF zone. The first SF experiments provide a basis for future SF studies in MAST-U tokamak with higher input power, improved plasma control and diagnostic measurements, to be compared with the modeling predictions of plasma convective SF mixing and lower density strike point detachment threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Implementation of Surface Eroding Thermocouples for Stage-One Modular Divertor Integration at the DIII-D Tokamak

The DIII-D has upgraded its upper divertor to a modular system using copper alloy pedestals to alter the divertor geometry without changing the vessel structure. Six new graphite tiles were designed for the shape and volume rise (SVR) divertor. Here, these new SVR tiles facilitated the formation of a poloidal array of 27 surface eroding thermocouples (SETCs) in the upper divertor region. At one location, a specialized recessed SETC, paired with a standard flush SETC, was installed in one of the ceiling tiles to provide comprehensive heat flux measurements, distinguishing between charged and noncharged particle contributions. Upgrades were made to the SETC system in the small-angle slot (SAS) divertor to improve overall performance. These upgrades included optimizing the feedthrough system to double the thermocouple cable capacity and reallocating cables from the SAS area to the SVR divertor. A compact isolation amplifier system with a fixed gain of 41 was employed to improve the signal level and minimize interference. Additionally, two analog-to-analog fiber systems were implemented for transmitting thermocouple signals over a single fiber, significantly reducing both noise levels and costs. The newly installed SETCs in the SVR divertor successfully completed initial commissioning testing. The SETCs captured the in-out asymmetry in the power distribution between the inner and outer strike points and demonstrated the dependency of the heat flux profile on the outer strike point location. During divertor detachment, heat flux mitigation was noted at the outer strike point location, while significant heat flux contributions from neutral particles were measured in the SVR divertor.

Divertor↗

Initial TCV operation with a baffled divertor

The Tokamak à Configuration Variable (TCV) tokamak is in the midst of an upgrade to further its capability to investigate conventional and alternative divertor configurations. To that end, modular and removable gas baffles have been installed to decrease the coupling between the divertor and the plasma core. The baffles primarily seek to suppress the transit of recycling neutrals to closed flux surfaces. A first experimental campaign with the gas baffles has shown that the baffled divertor remains compatible with a wide range of configurations including snowflake and super-X divertors. Plasma density ramp experiments reveal an increase of the neutral pressure in the divertor by up to a factor ×5 compared to the unbaffled divertor and thereby qualitatively confirm simulations with the SOLPS-ITER code that were used to guide the baffle design. Finally, together with a range of new and upgraded divertor diagnostics, the baffled TCV divertor is now used to validate divertor models for ITER and next step devices with particular emphasis on geometric variations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a Novel Variable Geometry Divertor for Tokamaks

The divertor is a key component of fusion reactors, allowing exhaust of gas, impurities, and helium ash to preserve plasma purity. The divertor geometry strongly affects plasma performance, and it is designed to be compatible with different plasma shapes in present-day fusion experiments. Here, we present a novel concept for a variable geometry divertor, in which the divertor baffle tiles are reorientable by external actuation. Implementation of this concept in a medium-sized research tokamak would uniquely provide the flexibility to tailor divertor geometry to the plasma configuration and also enable study of the effect of divertor closure on plasma performance. To ensure compatibility with typical tokamak operations, the adjustable divertor must withstand the effects of significant mechanical and thermal stresses such as MW/m 2 -scale heat fluxes and large electromagnetic fields, e.g., disruption forces. The technological solutions for actuation mechanisms, cooling system, gas baffling and plasma-facing components are assessed. A functional reduced-scale model with movable outer divertor target baffle tiles is developed and the actuation mechanism is tested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress of Divertor Heat and Particle Flux Control in EAST for Advanced Steady-State Operation in the Last 10 Years

Active control of the excessively high heat and particle fluxes on the divertor target plates is of fundamental importance to the steady state operation of tokamaks, especially for fusion reactors. A series of experiments have been carried out on this critical issue to relieve the plasma-wall interactions in the experimental advanced superconducting tokamak (EAST) in the last ten years, not only contributing to the long pulse operation of EAST itself, but also providing physical understandings and potential techniques to the next-generation devices like ITER. Here we have characterized the power deposition pattern and broadened the divertor footprint width effectively. The plasma-wetted area is actively handled using either 3-dimentional edge magnetic topology or advanced plasma equilibrium, thereby peak heat flux around the strike point is reduced. Active control of detachment or radiation compatible with core plasma performance has progressed significantly in very recent years, with a series of active feedback control modules developed and utilized successfully, based on the divertor physics advances with both experiments and simulation. The upper divertor of EAST was upgraded from graphite to active water-cooling ITER-like tungsten in 2014, exhibiting much enhanced heat removal capability. As for the particle exhaust including both fueling and impurity particles, in addition to wall conditioning and impurity source control, the efficiency of particle flux exhaust is optimized by making full use of the divertor closure and the plasma drifts in both scrape-off layer and divertor volume. These heat and particle exhaust advances contribute greatly to a series of EAST achievements like H-mode operation over 100 s. A brief near-term plan on the integrated control of divertor plasma-wall interactions in long-time scale will also be introduced, aiming to provide favorable divertor operation solution for ITER and CFETR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active Lithium Injection for a Real Time Control of the Divertor Heat Flux for Fusion Devices

When the local heat flux exceeds specified flux limit, tungsten PFC surfaces can be damaged, which is not acceptable for a reliable reactor operations. The divertor PFCs are typically designed for a specific heat flux limit usually assuming an average steady-state heat flux which is typically 5–10 MW/m 2 . However, in addition to steady-state heat flux, fusion reactor divertor PFCs could experience transient heat fluxes such as ELMs and/or other magnetic reconnection events which can deposit large transient heat fluxes onto the divertor PFCs. The transient divertor heat flux could be significantly larger than the steady-state heat flux which could damage the solid PFC surfaces. The divertor heat flux can be subjected to additional complications such as the uncertainties in the the divertor strike point heat flux projection. Moreover, there are additional experimental observations of non-axisymmetric power flux which can occur under non-axisymmetric magnetic perturbations. The liquid lithium (LL) PFCs is more resilient against such transient heat fluxes as they could evaporate LL as needed and the lost LL can be then replenished afterward. In this paper, we analyze a case for a transient divertor heat pulse of 1 MJ in 10 ms for a ITER-size reactor. This is a small perturbation (~ 0.1%) to the expected plasma stored energy compared to the previously analyzed case of 20 MJ heat pulse. Even with this relatively modest heat pulse, the LL surface undergoes ~ 100 °C temperature rise. However, the resulting LL surface heating without rapid cooldown mechanism could lead to excessive LL evaporation continuing well after the transient heat flux resulting in a significant Li injection of ~ 0.6 mol in about a 200 ms period. This amount of Li injection could cause plasma dilution and performance degradation. On the other hand, an active Li injection capability if optimized could prevent the LL surface temperature rise and thus reducing subsequent Li evaporation into the plasma by a factor of 7 compared to the passive LL PFC case. A crucial tool of active Li injection is a rapid response pellet injector which could inject light impurity pellets before the excessive heat flux could reach the divertor plate causing serious damage. A simple pellet ablation model suggests a favorable pellet deposition profile for smaller ~ 0.1 mm radius pellet with ~ 10–20 m/s velocity. Moreover, if it is possible to inject from the private flux region, the pellet injection efficiency into the high heat flux strike point region can be as high as 80% compared to ~ 50% for the injection from outer radius region. The pellet deposition efficiency can be further improved by designing a shell-pellet which can burst when a certain ablation fraction is reached. Finally, a possible implementation technique using an inductive pellet injector with a rapid time response of a few msec is proposed here which can be tested in NSTX-U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experiment-modeling studies comparing energy dissipation in the DIII-D SAS and SAS-VW divertors

Recent DIII-D experiments on Small Angle Slot (SAS) divertors have confirmed that a combination of divertor closure and target shaping can enhance cooling across the divertor target and increase energy dissipation, but with significant dependence on B T (toroidal magnetic field) direction. In these novel divertors, the roles of closure, target shaping, drifts, and scale lengths are all interconnected in optimizing dissipation, with the separatrix electron density n eSEP being the key parameter associated with the level of dissipation/detachment. After modifying the original flat-targeted graphite SAS to include a V shape with a tungsten coating on the outer side of the divertor (SAS-VW), matched series of discharges were run to compare to detailed SOLPS-ITER modeling. Experimentally, when run as designed with the outer strike point at the slot vertex, SAS-VW requires nearly identical n eSEP for detachment as the original SAS, with little difference in dissipation for the new geometry. This is in contrast to (1) earlier modeling predictions that a small change of the SAS geometry to a V shape should enhance dissipation at the same n eSEP for magnetic configurations having better H-mode access (ion B × ∇B drift directed into the divertor), and (2) despite the achievement of significantly higher (2-7x) neutral pressures and compression in the SAS-VW slot. Comparisons of experimental density scans to the most recent SOLPS-ITER modeling with ExB drifts show reasonable agreement for dissipation/detachment onset when using separatrix density as the independent parameter. In order to help understand the discrepancy in modeled vs actual performance for the new configuration, additional measurements varying gas injection location and impurity injection were undertaken. In-slot D 2 gas fueling is more effective (5–22 %) in promoting detachment, in accord with modeling. In-slot impurity injection (N 2 or Ne) can yield 30 % lower core Z eff and 15 % less confinement degradation after detachment compared to main chamber puffing, as well as relatively lower tungsten leakage from the divertor. Modeling can also reproduce the improved detachment seen as the strike point moves inboard of the slot vertex. While we can explain the effects of the most important parameters causing energy dissipation in these slot divertors, it remains that many aspects of their behavior cannot be accurately modeled using state-of-art codes such as SOLPS-ITER. This is of concern for future model-driven designs utilizing similar V-shaped geometries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and physics basis for the upcoming DIII-D SAS-VW campaign to quantify tungsten leakage and transport in a new slot divertor geometry

A set of experiments are planned to exploit the high SOL collisionality enabled by a tightly baffled slot divertor geometry to suppress tungsten leakage in DIII-D. A toroidal row of graphite tiles from the Small Angle Slot (SAS) divertor is being coated with 10–15 μ m of tungsten. New spectroscopic viewing chords with in-vacuo optics will measure the W gross erosion source from the divertor surface with high spatial and temporal resolution. In parallel, the bottom of the SAS divertor is changed from a flat to a ‘V’ shape. New SOLPS-ITER/DIVIMP simulations conducted with drifts using the planned ‘V’ shape predict a substantial reduction in W sourcing and SOL accumulation in either B × ∇B direction relative to either the old SAS divertor shape or the open, lower divertor. Dedicated studies are planned to carefully characterize the level of W sourcing, leakage, and scrape-off-layer (SOL) accumulation in DIII-D over a wide range of plasma scenarios. Various actuators will be assessed for their efficacy in further reducing high-Z impurity sources and leakage from the slot divertor geometry. Finally, this coupled code-experiment validation effort will be used to stress-test physics models and build confidence in extrapolations to advanced, high-Z divertor geometries for next-step devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-point and divertor filament dynamics from gas puff imaging on TCV

Abstract A new gas puff imaging diagnostic has been installed on the TCV tokamak, providing two-dimensional insights into scrape-off-layer (SOL) turbulence dynamics above, at and below the magnetic X-point. A detailed study in L-mode, attached, lower single-null discharges shows that statistical properties have little poloidal variations, while vast differences are present in the 2D behaviour of intermittent filaments. Strongly elongated filaments, just above the X-point and in the divertor far-SOL, show a good consistency in shape and dynamics with field-line tracing from filaments at the outboard midplane, highlighting their connection. In the near-SOL of the outer divertor leg, short-lived, high frequency and more circular (diameter ∼15 sound Larmor radii) filaments are observed. These divertor-localised filaments appear born radially at the position of maximum density and display a radially outward motion with velocity ≈400 m s −1 that is comparable to radial velocities of upstream-connected filaments. Conversely, in these discharges ( B → × ∇ B pointing away from the divertor), these divertor filaments’ poloidal velocities differ strongly from those of upstream-connected filaments. The importance of divertor-localised filaments upon radial transport and profile broadening is explored using filament statistics and in situ kinetic profile measurements along the divertor leg. This suggests that these filaments contribute significantly to electron density profile broadening in the divertor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy and particle balance during plasma detachment in a long-leg divertor configuration

Abstract Comprehensive studies of energy and particle balances in the transition to plasma detachment in an alternative divertor configuration with long outer legs are shown. Numerical simulations are performed with the 2D code suite SOLPS 4.3, using a disconnected double null grid with narrow, tightly baffled long poloidal leg divertors at the outer lower target and outer upper target. A particle count scan is performed using the ‘closed gas box’ model, where the tunable parameter in the simulations is the total number of deuterium particles in the simulation space and all other parameters are held fixed, including a constant input power and trace neon impurity radiation, to assess the physics of the transition to detachment in the system as the particle count increases. Three main aspects of the physics of divertor detachment are addressed: the criteria for the local onset of divertor detachment in each of the divertors, the distribution of heat flux and other plasma parameters between the four divertors as each divertor transitions to detachment, and the role of perpendicular transport in the transition to the detached regime. A synergistic mechanism by which the cross-field transport is reduced by factors associated with the onset of plasma recombination effects is identified. These results are compared to the existing understanding of the physics of the transition to plasma detachment in standard divertors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of ITER divertor shunts as a synthetic diagnostic for detachment control

Reliable diagnostics that measure the detached state of the ITER divertor plasma will be necessary to control heat flux to the divertor targets during steady state, burning plasma operation. This paper conducts an initial exploration into the feasibility of the divertor shunt diagnostic as a lightweight, robust, and real-time detachment sensor. This diagnostic is a set of shunt lead pairs that measure the voltage drop along the divertor cassette body, from which the plasma scrape-off layer (SOL) current is calculated. Using SOLPS-ITER simulations for control-relevant ITER plasma scenarios, the thermoelectric current magnitude along the SOL is shown to decrease significantly with the onset of partial detachment at the outer divertor target. Electromagnetic modelling of a simplified divertor cassette is used to develop a control-oriented inductance-resistance circuit model, from which SOL currents can be calculated from shunt pair voltage measurements. The sensitivity and frequency-response of the resulting system indicates that the diagnostic will accurately measure SOL thermoelectric currents during ITER operation. These currents will be a good measure of the detached state of the divertor plasma, making the divertor shunt diagnostic a potentially extremely valuable and physically robust sensor for real-time detachment control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis and design of fast flow liquid Li divertor for fusion nuclear science facility (FNSF) using coupled plasma boundary and LM MHD/heat transfer codes *

The SOLPS-ITER code is utilized to analyze the boundary plasma associated with a fast-flow lithium (Li) divertor configuration in the fusion nuclear science facility (FNSF) tokamak and identify operational regimes with acceptable divertor and core conditions. Plasma transport from the SOLPS-ITER code has been coupled with a liquid metal (LM) MHD/heat transfer code to model a Li open-surface divertor design and assess its impact on the scrape-off-layer (SOL) and core plasma performance. Simulations with only Neon (Ne) impurity seeding have been conducted to evaluate its impact on meeting FNSF design demands for the divertor and upstream plasma parameters. Simulation results indicate that Ne seeding significantly mitigates divertor heat flux but potentially reduces both upstream electron and main ion density due to fuel dilution. The combined application of Ne seeding and deuterium (D 2 ) puffing is required to satisfy the FNSF design requirements on upstream density ($n^{OMP}_{e,sep}$~1× 10 20 m -3 ) and divertor energy flux ($q^{Odiv}_{\bot,max}$<10 MW m -2 ). D 2 puffing plays a role in counteracting upstream density drops and augmenting energy and momentum losses through atomic and molecular processes. The inlet Li flow velocity is systematically varied across a wide range to identify acceptable flows and corresponding LM surface temperatures. This comprehensive analysis identifies the acceptable Li flow parameters, LM surface temperature, and emitted Li fluxes necessary to meet the major design constraints. The emitted Li fluxes exhibit minimal impact on the main plasma at surface temperatures up to approximately ~525 °C, corresponding emitted Li fluxes of up to φ Li ~2X10 23 atoms s -1 . Uncertainties in the Li emission processes from the surface are also investigated, primarily influencing Li loss in the lower surface temperature range (<525 °C), with simulation results indicating a minor impact on the divertor and upstream plasma. Conversely, evaporation predominantly drives the Li loss processes at higher surface temperature ranges (>525 °C), contaminating both the divertor and upstream plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiative divertor detachment and impurity transport with nitrogen and neon seeding in KSTAR H-mode plasmas

Achieving core-edge compatible divertor detachment is a critical requirement for stable operation in future fusion devices. This study compares nitrogen and neon seeding in KSTAR H-mode plasmas with carbon walls, combining experiments and SOLPS-ITER modelling to evaluate their radiative dissipation and core-edge compatibility. Experimentally, N seeding achieved stronger divertor detachment, with larger reductions in target particle and heat fluxes, a higher divertor radiation fraction, and a lower core radiation fraction than Ne. In contrast, Ne seeding triggered a significant rise in core radiation followed by H–L back transitions, limiting the maximum total radiated power fraction to roughly half that of N. SOLPS-ITER simulations reproduced the experimental trends and revealed that the better core-edge compatibility of N arises from its higher divertor retention in addition to its higher cooling factor. The relative positions of the stagnation points of impurity poloidal velocity and ionization sources did not explain the different divertor compression. Instead, in the present modelling, the higher impurity parallel particle flux, resulting from the higher parallel impurity velocity, explains the stronger nitrogen impurity compression in the divertor region. The parallel temperature distribution with N was more favourable for achieving higher impurity parallel velocity than with Ne, because the impurity velocity is governed by modifications of the main ion flow due to friction and thermal forces, both of which strongly depend on the temperature. Ultimately, this behaviour is attributed to the strongly divertor-localized radiation of N. These results demonstrate that N is more effective than Ne in achieving radiative divertor detachment while maintaining low core contamination in KSTAR, consistent with observations in other present tokamaks.

KSTAR↗

Divertor heat flux challenge and mitigation in SPARC

Owing to its high magnetic field, high power, and compact size, the SPARC experiment will operate with divertor conditions at or above those expected in reactor-class tokamaks. Power exhaust at this scale remains one of the key challenges for practical fusion energy. Based on empirical scalings, the peak unmitigated divertor parallel heat flux is projected to be greater than 10 GW m -2 . This is nearly an order of magnitude higher than has been demonstrated to date. Furthermore, the divertor parallel Edge-Localized Mode (ELM) energy fluence projections (~11–34 MJ m -2 ) are comparable with those for ITER. However, the relatively short pulse length (~25 s pulse, with a ~10 s flat top) provides the opportunity to consider mitigation schemes unsuited to long-pulse devices including ITER and reactors. The baseline scenario for SPARC employs a ~1 Hz strike point sweep to spread the heat flux over a large divertor target surface area to keep tile surface temperatures within tolerable levels without the use of active divertor cooling systems. In addition, SPARC operation presents a unique opportunity to study divertor heat exhaust mitigation at reactor-level plasma densities and power fluxes. Not only will SPARC test the limits of current experimental scalings and serve for benchmarking theoretical models in reactor regimes, it is also being designed to enable the assessment of long-legged and X-point target advanced divertor magnetic configurations. Experimental results from SPARC will be crucial to reducing risk for a fusion pilot plant divertor design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Liquid lithium as divertor material to mitigate severe damage of nearby components during plasma transients

The successful operation of thermonuclear fusion reactors such as ITER, DEMO, and future commercial plants is mainly determined by the optimum choice of materials for various components. The objective of this work is to accurately and comprehensively simulate the entire device in 3D to predict pros and cons of various materials, e.g., liquid lithium in comparison to tungsten and carbon to predict future ITER-like and DEMO divertor performances. We used our comprehensive HEIGHTS simulation package to investigate ITER-like components response during transient events in exact 3D geometry. Starting from the lost hot core plasma particles through SOL, deposition on the divertor surface, and the generation of secondary plasma of divertor materials. Our simulations predicted significant reduction in the heat loading and damage to the divertor nearby and internal components in the case when lithium is used on the divertor plates. While if tungsten or carbon are used on the divertor plate, significant melting areas and vaporization spots can occur (less for carbon) on the reflector, dome, and stainless steel tubes, and even parts of the first walls can melt due to the high radiation power of the secondary divertor plasma. Lithium photon radiation deposition into the divertor and nearby surfaces was decreased by two orders of magnitude compared to tungsten and by one order of magnitude compared to carbon. This analysis showed that using liquid lithium for ITER-like surfaces and future DEMO can lead to significant enhancement in components lifetime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗