Search NASA⌕ Search

SEARCH · Search NASA

Results for “electric plant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

New Energy Infrastructure Outlook: Data as of December 31, 2024 [Slides]

This report provides a perspective on energy infrastructure under development in the continental U.S. as of the end of 2024, focusing on those making significant progress toward achieving commercial operation. Infrastructures covered in this report include power plants, electric transmission, natural gas pipelines and liquefied natural gas facilities. Additionally, this report includes a section on stockpiled volumes of coal, natural gas, and petroleum.

01 COAL, LIGNITE, AND PEAT↗

Development of Cable Aging Acceptance Criteria for Nuclear Facilities

The aging of nuclear power plant electrical cables has been the subject of substantial research and development (R&D) projects in the nuclear industry, national and international laboratories, universities, and vendor organizations for several years. More specifically, these R&D efforts were conducted to develop equipment and techniques for assessing age-related degradation of in-service cables in nuclear facilities including power plants, research reactors, waste facilities and fuel fabrication plants. In recent years, cable R&D efforts in the nuclear arena have also included work to develop new cables for the next generation of reactors. Over time, exposure to harsh environmental conditions such as elevated temperatures, radiation, and humidity in nuclear installations can result in age-related degradation and failure of cables. In the current fleet of nuclear reactors, there are thousands of miles of cabling installed in each plant and many of these cables are exposed to these harsh environmental conditions. For these cables, the jacket and insulation polymers harden and become brittle over time, making them more susceptible to crack formation and growth, moisture intrusion, and other mechanisms that can lead to cable failure. Moreover, the existing U.S. fleet of 98 nuclear reactors has an average operating age of 38 years. Many of these nuclear power plants have applied for and almost all have been granted regulatory approval for license renewals to operate for 60 years, 20 years beyond their original 40-year life. Further, subsequent license renewals (SLRs) are underway with a few commercial nuclear power sites already approved to operate up to 80 years. As these reactors pursue operating life extensions, utilities must find a way to address issues associated with age-related degradation of cables. Designers of small modular reactors are also in need of technologies to evaluate the performance of cables that will be installed in harsher environments (e.g. higher temperatures, radiation doses, dose rates, etc.) than those present in current-generation reactors. Today, a variety of cable condition monitoring (CM) techniques have been developed and successfully used in nuclear facilities. These techniques are used to identify age-related degradation and assess the condition of cables to determine if their performance characteristics have changed with age. However, objective criteria must be developed for these CM tests to help quantify cable condition and thereby develop repair and replacement schedules. With operating life extending to 80 years and more SLRs on the horizon, both nuclear facilities and regulators need an objective means to determine the aged condition of cables.

36 MATERIALS SCIENCE↗

Development of Cable Aging Acceptance Criteria for Nuclear Facilities

The aging of nuclear power plant electrical cables has been the subject of substantial research and development (R&D) projects in the nuclear industry, national and international laboratories, universities, and vendor organizations for several years. More specifically, these R&D efforts were conducted to develop equipment and techniques for assessing age-related degradation of in-service cables in nuclear facilities including power plants, research reactors, waste facilities and fuel fabrication plants. In recent years, cable R&D efforts in the nuclear arena have also included work to develop new cables for the next generation of reactors. Over time, exposure to harsh environmental conditions such as elevated temperatures, radiation, and humidity in nuclear installations can result in age-related degradation and failure of cables. In the current fleet of nuclear reactors, there are thousands of miles of cabling installed in each plant and many of these cables are exposed to these harsh environmental conditions. For these cables, the jacket and insulation polymers harden and become brittle over time, making them more susceptible to crack formation and growth, moisture intrusion, and other mechanisms that can lead to cable failure. Moreover, the existing U.S. fleet of 98 nuclear reactors has an average operating age of 38 years. Many of these nuclear power plants have applied for and almost all have been granted regulatory approval for license renewals to operate for 60 years, 20 years beyond their original 40-year life. Further, subsequent license renewals (SLRs) are underway with a few commercial nuclear power sites already approved to operate up to 80 years. As these reactors pursue operating life extensions, utilities must find a way to address issues associated with age-related degradation of cables. Designers of small modular reactors are also in need of technologies to evaluate the performance of cables that will be installed in harsher environments (e.g. higher temperatures, radiation doses, dose rates, etc.) than those present in current-generation reactors. Today, a variety of cable condition monitoring (CM) techniques have been developed and successfully used in nuclear facilities. These techniques are used to identify age-related degradation and assess the condition of cables to determine if their performance characteristics have changed with age. However, objective criteria must be developed for these CM tests to help quantify cable condition and thereby develop repair and replacement schedules. With operating life extending to 80 years and more SLRs on the horizon, both nuclear facilities and regulators need an objective means to determine the aged condition of cables.

36 MATERIALS SCIENCE↗

Hardware-based Advanced Electromagnetic Transient Simulation for A Large-Scale PV Plant in Real Time Digital Simulator

Power electronics-based resources, such as high-voltage direct current (HVdc) substations, photovoltaic (PV) plants, wind plants, electric vehicle charging stations, and energy storage systems, are increasingly being integrated within the power grid. Recently, multiple reports have emphasized the necessity for high-fidelity electromagnetic transient (EMT) simulations of these large-scale power electronics-based resources to accurately understand their behavior in power grids. However, performing hardware-based EMT simulations with high-fidelity models for such large power electronics systems is challenging due to the small time-step requirements and the involvement of a large number of states. This paper presents the implementation of hardware-based high-fidelity EMT dynamic model of a large-scale PV plant, accomplished through custom model development using the specific-C language in real-time digital simulator hardware (RTDS) and software (RSCAD).

Choi, Jongchan↗

Performance Test Code for Determining and Reporting Annual Heat Rate and CO2 for Coal Fueled EGUs

This material is based upon work supported by the Department of Energy under Award Number DEFE0031933. The US Department of Energy (DOE) has retained the services of ASME Standards Technology LLC (ASME ST-LLC) to develop a standardized test method and calculation protocol for determining and reporting annual/long-term heat rate for coal-fueled plants electricity generating units. ASME ST-LLC has retained the services of McHale & Associates, Inc. and Licata Energy & Environmental Consultants, Inc. to provide the technical input to this study. This code applies to hydrocarbon fueled Rankine cycle power generating facilities of any size. It is intended to be used for the determination of continuous power output and heat rate of a generating facility in its operating load cycle and in its operational lineup during the reporting period.

01 COAL, LIGNITE, AND PEAT↗

Methods and system for siting advanced nuclear reactors and evaluating energy policy concerns

There is a growing sociopolitical desire to develop cleaner energy sources in the United States and maintain energy security. Regardless of politics, many coal-fired electric plants have already been shut down and many utilities are vowing to retire their current coal-fired assets within the next two decades. Replacement power assets require consideration of appropriate siting. A geographic information system (GIS)-based multicriteria decision analysis approach is useful to assist utility and energy companies, as well as policymakers, to evaluate potential areas for siting new plants in the contiguous United States. A GIS-based framework is simply a database of location information that allows for mapping, querying, modeling, and analyzing data based on location. The spatial output can be structured to be visual, allowing for easier analysis of location data. The need to site additional power assets, including renewable resources and clean power sources, such as nuclear, led to the development of the Oak Ridge Siting Analysis for power Generation Expansion (OR-SAGE) tool discussed in this paper. The tool takes inputs such as population growth, water availability, environmental indicators, and tectonic and geological hazards to provide an in-depth visual analysis for siting options. Energy companies and other stakeholders can use OR-SAGE to procure feedback quickly and effectively on land suitability based on technology specific inputs. Policymakers can use OR-SAGE to analyze the impacts of future energy technology decisions, while balancing competing resource use. Overall, this paper discusses the recent use of OR-SAGE for these purposes and plans for future development.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

New Energy Infrastructure Outlook 2021 [Slides]

This report provides a perspective on energy infrastructure under development in the continental U.S. as of the end of 2020, focusing on those making significant progress toward achieving commercial operation. Infrastructures covered in this report include power plants, electric transmission, natural gas pipelines and liquefied natural gas terminals. Additionally, this report includes a section on stockpiled volumes of coal, natural gas, and petroleum.

24 POWER TRANSMISSION AND DISTRIBUTION↗

New Energy Infrastructure Outlook 2022 [Slides]

This report provides a perspective on energy infrastructure under development in the continental U.S. as of the end of 2021, focusing on those making significant progress toward achieving commercial operation. Infrastructures covered in this report include power plants, electric transmission, natural gas pipelines and liquefied natural gas terminals. Additionally, this report includes a section on stockpiled volumes of coal, natural gas, and petroleum.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermal study of the Missouri River in North Dakota using infrared imagery

Studies of infrared imagery obtained from aircraft at 305- to 1,524-meter altitudes indicate the feasibility of monitoring thermal changes attributable to the operation of thermal electric plants and storage reservoirs, as well as natural phenomena such as tributary inflow and ground water seeps in large rivers. No identifiable sources of ground water inflow below the surface of the river could be found in the imagery. The thermal patterns from the generating plants and the major tributary inflow are readily apparent in imagery obtained from an altitude of 305 meters. Portions of the tape-recorded imagery were processed in a color-coded quantization to enhance the displays and to attach quantitative significance to the data. The study indicates a marked decrease in water temperature in the Missouri River prior to early fall and a moderate increase in temperature in late fall because of the Lake Sakakawea impoundment.

Crosby, O. A.↗

A brief summary of the attempts to develop large wind-electric generating systems in the US

Interest in developing large wind-electric generating systems in the United States was simulated primarily by one man, Palmer C. Putnam. He was responsible for the construction of the 1250 kilowatt Smith-Putnam wind-electric plant. The existence of this system prompted the U. S. Federal Power Commission to investigate the potential of using the winds as a source energy. Also, in 1933 prior to Putnam's effort, there was an abortive attempt by J. D. Madaras to develop a wind system based on the Magnus effect. These three projects comprise the only serious efforts in America to develop large wind driven plants. In this paper the history of each project is briefly described. Also discussed are some of the reasons why wind energy was not seriously considered as a major source of energy for the U. S.

Savino, J. M.↗

A brief summary of the attempts to develop large wind-electric generating systems in the U.S.

Interest in developing large wind-electric generating systems in the United States was stimulated primarily by one man, Palmer C. Putnam. He was responsible for the construction of the largest wind-power system ever built - the 1250 kilowatt Smith-Putnam wind-electric plant. The existence of this system prompted the U.S. Federal Power Commission to investigate the potential of using the winds as a source energy. Also, in 1933 prior to Putnam's effort, there was an abortive attempt by J. D. Madaras to develop a wind system based on the Magnus effect. These three projects comprise the only serious efforts in America to develop large wind driven plants. In this paper, the history of each project is briefly described. Also discussed are some of the reasons why wind energy was not seriously considered as a major source of energy for the U.S.

Savino, J. M.↗

A preliminary systems-engineering study of an advanced nuclear-electrolytic hydrogen-production facility

An advanced nuclear-electrolytic hydrogen-production facility concept was synthesized at a conceptual level with the objective of minimizing estimated hydrogen-production costs. The concept is a closely-integrated, fully-dedicated (only hydrogen energy is produced) system whose components and subsystems are predicted on ''1985 technology.'' The principal components are: (1) a high-temperature gas-cooled reactor (HTGR) operating a helium-Brayton/ammonia-Rankine binary cycle with a helium reactor-core exit temperature of 980 C, (2) acyclic d-c generators, (3) high-pressure, high-current-density electrolyzers based on solid-polymer electrolyte technology. Based on an assumed 3,000 MWt HTGR the facility is capable of producing 8.7 million std cu m/day of hydrogen at pipeline conditions, 6,900 kPa. Coproduct oxygen is also available at pipeline conditions at one-half this volume. It has further been shown that the incorporation of advanced technology provides an overall efficiency of about 43 percent, as compared with 25 percent for a contemporary nuclear-electric plant powering close-coupled contemporary industrial electrolyzers.

Escher, W. J. D.↗

Thermal energy storage systems using fluidized bed heat exchangers

The viability of using fluidized bed heat exchangers (FBHX) for thermal energy storage (TES) in applications with potential for waste heat recovery was investigated. Of the candidate applications screened, cement plant rotary kilns and steel plant electric arc furnaces were identified, via the chosen selection criteria, as having the best potential for successful use of FBHX/TES system. A computer model of the FBHX/TES systems was developed and the technical feasibility of the two selected applications was verified. Economic and tradeoff evaluations in progress for final optimization of the systems and selection of the most promising system for further concept validation are described.

Ramanathan, V.↗

The Geothermal Probabilistic Cost Model with an Application to a Geothermal Reservoir at Heber, California

A financial accounting model that incorporates physical and institutional uncertainties was developed for geothermal projects. Among the uncertainties it can handle are well depth, flow rate, fluid temperature, and permit and construction times. The outputs of the model are cumulative probability distributions of financial measures such as capital cost, levelized cost, and profit. These outputs are well suited for use in an investment decision incorporating risk. The model has the powerful feature that conditional probability distribution can be used to account for correlations among any of the input variables. The model has been applied to a geothermal reservoir at Heber, California, for a 45-MW binary electric plant. Under the assumptions made, the reservoir appears to be economically viable.

Orren, L. H.↗

Geothermal probabilistic cost study

A tool is presented to quantify the risks of geothermal projects, the Geothermal Probabilistic Cost Model (GPCM). The GPCM model was used to evaluate a geothermal reservoir for a binary-cycle electric plant at Heber, California. Three institutional aspects of the geothermal risk which can shift the risk among different agents was analyzed. The leasing of geothermal land, contracting between the producer and the user of the geothermal heat, and insurance against faulty performance were examined.

Orren, L. H.↗

Wing Flutter Control

Through Small Business Innovation Research (SBIR) contracts from Langley Research Center, Orbital Research Inc. developed the Orbital Research Intelligent Control Algorithm (ORICA), the first practical hardware-independent adaptive predictive control structure, specifically suited for optimal control of complex, time-varying systems. ORICA technology has been applied to the problem of controlling aircraft wing flutter. Coupled with NASA expertise, the technology has the possibility of making jet travel safer, more cost effective by extending distance range, and lowering overall aircraft operating costs. Future application areas for ORICA include control of robots, power trains, systems with arrays of sensors, or regulating chemical plants or electrical power plant control.

Source record↗

Cogeneration power systems

Cogeneration is defined as the combination of electrical generation and process heat for more efficient use of fuel. Comparisons of energy utilization in conventional electric power plants and cogeneration electric power plants are presented. Characteristics of various cogeneration systems are also presented. Systems are analyzed for use in utility systems and industrial systems. Economic and cost analysis are reviewed.

Davis, H. S.↗

Generic characterization of electrical test benches for AC- and HVDC-connected wind power plants

The electrical test and assessment of wind turbines go hand in hand with standards and network connection requirements. In this paper, the generic structure of advanced electrical test benches, including grid emulator or controllable grid interface, wind torque emulator, and device under test, is proposed to harmonize state-of-the-art test sites. On the other hand, modern wind turbines are under development towards new features, concerning grid-forming, black-start, and frequency support capabilities as well as harmonic stability and control interaction considerations, to secure the robustness and stability of renewable-energy-based power systems. Therefore, it is necessary to develop new and revised test standards and methodologies to address the new features of wind turbines. This paper proposes a generic test structure within two main groups, including open-loop and closed-loop tests. The open-loop tests include the IEC 61400-21-1 standard tests as well as the additional proposed test options for the new capabilities of wind turbines, which replicate grid connection compliance tests using open-loop references for the grid emulator. In addition, the closed-loop tests evaluate the device under test as part of a virtual wind power plant and perform real-time simulations considering the grid dynamics. The closed-loop tests concern grid connection topologies consisting of AC and HVDC, as well as different electrical characteristics, including impedance, short-circuit ratio, inertia, and background harmonics. The proposed tests can be implemented using available advanced test benches by adjusting their control systems. The characteristics of a real power system can be emulated by a grid emulator coupled with real-time digital simulator systems through a high-bandwidth power-hardware-in-the-loop interface.

17 WIND ENERGY↗