At least 55 records · Page 3

What does the future hold for utility electricity efficiency programs?

Here, this study develops projections of future spending and savings from electricity efficiency programs funded by electric utility customers in the United States through 2030 based on three scenarios. Our analysis relies on detailed bottom-up modeling of current state energy efficiency policies, demand-side management and integrated resource plans, and regulatory decisions. The three scenarios represent a range of potential outcomes given the policy environment at the time of the study and uncertainties in the broader economic and state policy environment in each state. We project spending to increase to $8.6 billion in 2030 in the medium scenario, about a 45 percent increase relative to 2016 spending. In the high case, annual spending increases to $11.1 billion in 2030 and remains relatively flat in the low case ($6.8 billion in 2030). Our analysis suggests that electricity efficiency programs funded by utility customers will continue to impact load growth significantly at least through 2030, as savings as a percent of retail sales are forecast at 0.7 percent in the medium scenario and 0.98 percent in the high scenario.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Electric Cooking Equipment

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past three years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Meaningful Household Savings: Best Practices for Achieving Equitable Solar Development

The Meaningful Household Savings Community of Practice—and this report—focuses on electricity bill savings, other household savings, wealth-building opportunities, and other benefits such as tenant services provided to residents in master-metered buildings. For this report, the project team collected information about ways meaningful household savings have been defined; researched best practices to define, achieve, and quantify meaningful household savings; and identified strategies to scale the adoption and implementation of successful methods.

14 SOLAR ENERGY↗

Differential Temperature Control of Electrical Heaters

Energy savings realized from heaters that maintain low humidity in electrical equipment. Unit applies power to electrical-equipment heater only when equipment temperature drops below preset differential above ambient. With differential controller, power consumed only 118 kWh for savings of 410 kWh/day, or 77-percent energy savings.

Cole, K. N.↗

Sumner County Field Validation: An Assessment of Thermal Energy Storage in Municipal Buildings in Mixed-Humid Climates

The overall aim of the project was to conduct a full-scale implementation of TES in an operational administrative building in Sumner County, Kansas with a special focus of phase change material (PCM) passive implementation in the ceiling envelope. PCM was used with the intention of increasing the ability of public buildings to shift the peak HVAC energy demand and consumption. The study was conducted during the span of three years in 3 phases, (i) phase I: energy audit (pre-retrofit) (ii) phase II: ceiling tile installation (PCM retrofit), and (iii) phase III: energy evaluation (post-retrofit). Temperature and HVAC energy measurements as well as weather data collected is used for an extensive validation study and further parametric assessment to find (a) annual HVAC energy savings (b) peak period electricity and load savings focusing on cooling dominant months of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal storage system with coupled tanks

Methods and apparatus are disclosed for high-efficiency thermal storage with a fluid-filled “battery” tank positioned within a fluid-filled “reservoir” tank. Fluid loops couple the tanks to a heat pump and a building. The heat pump can charge the battery tank or deliver thermal energy (cold or heat) to a building, using the reservoir tank or ambient air as a thermal energy source. The battery tank can discharge energy to the building jointly with the heat pump or, at periods of peak electricity usage, with the heat pump switched off. Operating modes allow significant savings in electricity usage and mitigate the “duck curve.” Low duty cycle usage of the reservoir enables efficient underground thermal storage with less digging than conventional geothermal technologies. Additional efficiency is achieved with phase change materials installed inside a tank or in a tank wall, providing temperature regulation. Control methods are disclosed.

15 GEOTHERMAL ENERGY↗

Analysis of Hybrid Electric Aircraft Operations in the National Airspace System

This paper investigates the fuel burn and flight time impacts of hybrid electric aircraft operating in the National Airspace System. Future scenarios with hybrid electric flights and the same passenger travel capacity between city pairs as a baseline scenario, taken from historical data, were created. Aircraft that serviced select flights in the baseline scenario were replaced with hybrid electric aircraft based on the flight’s range and seat capacity. Additional hybrid electric flights were added to future scenarios when necessary to keep the future scenario passenger capacity equal or greater to that of the baseline scenario. The baseline and future scenarios were simulated in the NAS Digital Twin, a live, virtual, and constructive environment for building and executing simulations of the Nation Airspace System. Results showed that the future scenarios with hybrid electric flights saved fuel burn, but increased flight time. In the future scenarios, the additional hybrid electric flights did not cause any airports to exceed their operational capacity.

Simulation↗

Operating Hybrid Electric Aircraft in the National Airspace System

This paper investigates the fuel burn and flight time impacts of hybrid electric aircraft operating in the National Airspace System. Future scenarios with hybrid electric flights and the same passenger travel capacity between city pairs as a baseline scenario, taken from historical data, were created. Aircraft that serviced select flights in the baseline scenario were replaced with hybrid electric aircraft based on the flight’s range and seat capacity. Additional hybrid electric flights were added to future scenarios when necessary to keep the future scenario passenger capacity equal or greater to that of the baseline scenario. The baseline and future scenarios were simulated in the NAS Digital Twin, a live, virtual, and constructive environment for building and executing simulations of the Nation Airspace System. Results showed that the future scenarios with hybrid electric flights saved fuel burn, but increased flight time. In the future scenarios, the additional hybrid electric flights did not cause any airports to exceed their operational capacity.

hybrid electric aircraft↗

Evaluation of cooling setpoint setback savings in commercial buildings using electricity and exterior temperature time series data

Commercial buildings account for a significant amount of total energy produced in the US, and the Heating Ventilation and Cooling (HVAC) systems are one of the most significant components of their overall consumption. In this study, we proposed a new data-driven approach to evaluate HVAC cooling systems in commercial buildings and identify savings opportunities. The focus is an investigation of the impact of thermostat setpoint setback but using only whole building, electricity data taken at 15-min intervals for the analysis. We conducted a comparative study of setpoint setback characteristics on 432 commercial buildings with 5 building usage types across the United States. To accomplish this, both piecewise and Random Forest regression algorithms were employed using electricity and exterior temperature datasets to identify operational characteristics and the effective setpoints in the building to determine the corresponding savings opportunities. Both occupied and unoccupied time periods were studied across cooling degree days (CDD), when air conditioning is typically operational. Here the results show that in commercial buildings, on average, cooling systems account for 9.5% of total consumption. When a one degree setback during the cooling season is applied, an average of approximately 1.1% of annual consumption is achieved; retail and office buildings demonstrate the highest potential for savings. Additionally, we identified that the number of cooling degree days and base to peak ratio (BPR) are the most important variables for predicting the magnitude of the consumption of cooling systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Puerto Rico Solar-for-All: LMI PV Rooftop Technical Potential and Solar Savings Potential

The Puerto Rico Solar-For-All dataset provides Census Tract level estimates of residential low-to-moderate income (LMI) PV rooftop technical potential as well as solar electric bill savings potential for LMI communities at the municipality level. Each dataset is broken out by income group, defined by the Area Median Income (AMI), by tenure, and by building type. The underlying LiDAR data used the estimation were collected in 2015-2017 and the American Community Survey (ACS) data are from 2011-2015. This Puerto Rico Solar-For-All dataset is intended to extend the SEEDSII Solar-For-All estimates for the US 50-states ( https://www.nlr.gov/docs/fy18osti/70901.pdf ) for the territory of Puerto Rico using updated methods. Please see the data documentation for details.

14 SOLAR ENERGY↗

Savings in Action: Lessons from Observed and Modeled Residential Solar Plus Storage Systems [Slides]

The study performed two related analyses using data from a new-construction residential community equipped with rooftop solar and storage (S+S) in Arizona. The study analyzed the factors that determine customer electricity cost savings from S+S adoption. The research compared the Arizona case study data to modeled system performance to understand how models deviate from real-world outcomes. Based on these findings, NREL explored ways to improve such models and, conversely, use modeled results to suggest improvements to S+S dispatches.

14 SOLAR ENERGY↗

Power Switching Device

The MOS-Controlled Thyristor is a new type of power switching device for faster and more efficient control and management of power electronics. It enables power electronic switching at frequencies of 50 to 100 thousand times a second with much lower power losses than other semiconductor devices. Advantages include electric power savings and smaller space. The device is used in motor and power controllers, AC & DC motor drives and induction heating. Early development was supported by Lewis Research Center (LEW) and other agencies. General Electric''s power semiconductor operation, the initial NASA contractor, was later purchased by Harris Semiconductor.

Source record↗

Porous Iron Electrodes Reduce Energy Consumption During Electrocoagulation of a Virus Surrogate: Insights into Performance Enhancements Using Three-Dimensional Neutron Computed Tomography

Electrocoagulation has attracted significant attention as an alternative to conventional chemical coagulation because it is capable of removing a wide range of contaminants and has several potential advantages. In contrast to most electrocoagulation research that has been performed with nonporous electrodes, in this study, we demonstrate energy-efficient iron electrocoagulation using porous electrodes. In batch operation, investigation of the external pore structures through optical microscopy suggested that a low porosity electrode with sparse connection between pores may lead to mechanical failure of the pore network during electrolysis, whereas a high porosity electrode is vulnerable to pore clogging. Electrodes with intermediate porosity, instead, only suffered a moderate surface deposition, leading to electrical energy savings of 21% and 36% in terms of electrocoagulant delivery and unit log virus reduction, respectively. Neutron computed tomography revealed the critical role of electrode porosity in utilizing the electrode’s internal surface for electrodissolution and effective delivery of electrocoagulant to the bulk. Energy savings of up to 88% in short-term operation were obtained with porous electrodes in a continuous flow-through system. Further investigation on the impact of current density and porosity in long-term operation is desired as well as the capital cost of porous electrodes.

42 ENGINEERING↗

Mitigating urban climate-energy feedback with citywide building-integrated photovoltaics implementation

Urban heat islands (UHIs) intensify cooling demands, whose waste heat further exacerbates UHI, creating a self-reinforcing feedback loop. Building-integrated photovoltaics (BIPV) can break this cycle by generating electricity and altering urban climate-energy interactions, yet its net impact remains unresolved. Using a cross-scale modeling framework for 118,521 buildings in Hong Kong, we demonstrate that BIPV glazing reduces cooling demand through improved insulation and lower solar heat gain, while inducing diurnal thermal asymmetry of daytime warming (up to +1.9°C) and nighttime cooling (up to −2.5°C). This microclimate regulation indirectly contributes to a 0.6% reduction in citywide building energy use. Cumulative savings from electricity generation and reduced energy use reach 4.7% (2,060.2 GWh) and 10.1% (4,401.3 GWh) under low- and high-coverage deployment, respectively, with building-level savings of −20.1% ± 11.7% (mean ± SD) at high coverage. We establish BIPV as a configurable climate-energy regulator that enables net-zero, heat-resilient planning and quantifies deployment trade-offs in cooling-dominated cities worldwide.

Building-integrated photovoltaics (BIPV)↗

Interregional Electricity Transmission in the United States: Realized Savings and Opportunities for Increased Value, 2014 to 2023

Interregional electricity trade in the United States reduces total energy costs, but falls short of maximizing the economic potential of existing transmission infrastructure. This analysis of thirty-two U.S. electricity system interfaces crossing grid or market seams finds an average achieved cost savings of at least $1,226 million per year. This positive impact is offset by an average annual cost of uneconomic interchange of $551 million. Additional value of at least $238 million per year could be enabled by increasing utilization. Notably, uneconomic flows and low utilization rates can persist even when the price spread between regions is large. These conclusions are derived from historical (2014–2023) data on the magnitude and direction of interregional price spreads, the magnitude and direction of net energy transfers, and how these variables coincide, but do not account for all system constraints. These findings motivate the development and deployment of solutions that improve interregional transmission operations, in parallel with robust transmission infrastructure planning. JEL Classification: Q40 Energy: General

Q40 Energy: General↗

Solar-energy-system performance evaluation: Honeywell OTS 44, Ocmulgee, Georgia

The operation and technical performance of the solar operational test site (OTS 44) are described, based on data collected between April, 1981 and August, 1981. The following topics are discussed: system description, performance assessment, operating energy, energy savings, system maintenance, and conclusions. The solar energy system at OTS 44 is a hydronic heating and cooling system consisting of 5040 square feet of liquid cooled flat plate collectors; a 4000 gallon thermal storage tank; one 25 ton capacity organic Rankine cycle engine assisted water chillers; a forced draft cooling tower; and associated piping, pumps, valves, controls and heat rejection equipment. The solar system has eight basic modes of operation and several combination modes for providing space conditioning and hot water to the building. Data monitored during the 4 months of the operational test period found that the solar system collected 285 MMBtu of thermal energy of the total incident solar energy of 1040 MMBtu and provided 210 MMBtu for cooling and 10 MMBtu for heating and hot water. The net electrical energy saving due to the solar system was approximately 2600 kWh(e), and fossil energy saving was about 20 million Btu (MMBtu).

Mathur, A. K.↗

Cost analysis of distributed storage in AC and DC microgrids

Building and microgrid designs with highly-distributed electrical storage have potential advantages over today's conventional topologies with centralized storage. Herein this paper studies the capital cost benefits of several residential behind-the-meter distributed-storage topologies, including AC and DC versions of systems with load-packaged batteries and resilient sub-networks. The study begins by defining the block configuration of each topology. This work then develops a model for the cost of the power electronics necessary to interface with the storage elements. Finally, the analysis develops a model for the total cost of each storage topology, incorporating the installation and soft costs. The results suggest that while the cost of power electronics is lower in centralized topologies, the total cost is lower for distributed storage due to the avoided costs of installation and permitting. This paper also explores the benefits of load-packaged batteries for savings in electrical infrastructure.

25 ENERGY STORAGE↗