Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrolyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Electrolyzers Enhancing Flexibility in Electric Grids

This paper presents a real-time simulation with hardware-in-the-loop (HIL) based approach for verifying the performance of electrolyzer systems in providing grid support. Hydrogen refueling stations premdominantly use electrolyzer systems to generate hydrogen, and are proposed to have the potential of becoming smarter loads which can pro-actively provide grid services. Based on experimental findings electrolyzer systems are observed to have a high level of controllability and hence can add flexibility to the grid from demand side. Greater awareness and controllability is proposed, developed, implemented, and tested by a 'frond end controller' in real-time environment. It can optimize the operation of electrolyzer systems based on the information collected by a communication module. Real-time tests are performed to verify the performance of front end controller driven electrolyzers to provide grid support that enables greater economic revenue and grid support for hydrogen producers under dynamic conditions. The front end controller proposed in this paper is tested with electrolyzers, however it is proposed as a generic control topology that is applicable to any load.

08 HYDROGEN↗

Alkaline static feed electrolyzer based oxygen generation system

In preparation for the future deployment of the Space Station, an R and D program was established to demonstrate integrated operation of an alkaline Water Electrolysis System and a fuel cell as an energy storage device. The program's scope was revised when the Space Station Control Board changed the energy storage baseline for the Space Station. The new scope was aimed at the development of an alkaline Static Feed Electrolyzer for use in an Environmental Control/Life Support System as an oxygen generation system. As a result, the program was divided into two phases. The phase 1 effort was directed at the development of the Static Feed Electrolyzer for application in a Regenerative Fuel Cell System. During this phase, the program emphasized incorporation of the Regenerative Fuel Cell System design requirements into the Static Feed Electrolyzer electrochemical module design and the mechanical components design. The mechanical components included a Pressure Control Assembly, a Water Supply Assembly and a Thermal Control Assembly. These designs were completed through manufacturing drawing during Phase 1. The Phase 2 effort was directed at advancing the Alkaline Static Feed Electrolyzer database for an oxygen generation system. This development was aimed at extending the Static Feed Electrolyzer database in areas which may be encountered from initial fabrication through transportation, storage, launch and eventual Space Station startup. During this Phase, the Program emphasized three major areas: materials evaluation, electrochemical module scaling and performance repeatability and Static Feed Electrolyzer operational definition and characterization.

Noble, L. D.↗

High Pressure Electrolyzer System Evaluation

This report documents the continuing efforts to evaluate the operational state of a high pressure PEM based electrolyzer located at the NASA Glenn Research Center. This electrolyzer is a prototype system built by General Electric and refurbished by Hamilton Standard (now named Hamilton Sunstrand). It is capable of producing hydrogen and oxygen at an output pressure of 3000 psi. The electrolyzer has been in storage for a number of years. Evaluation and testing was performed to determine the state of the electrolyzer and provide an estimate of the cost for refurbishment. Pressure testing was performed using nitrogen gas through the oxygen ports to ascertain the status of the internal membranes and seals. It was determined that the integrity of the electrolyzer stack was good as there were no appreciable leaks in the membranes or seals within the stack. In addition to the integrity testing, an itemized list and part cost estimate was produced for the components of the electrolyzer system. An evaluation of the system s present state and an estimate of the cost to bring it back to operational status was also produced.

Prokopius, Kevin↗

Operando X-ray tomography and sub-second radiography for characterizing transport in polymer electrolyte membrane electrolyzer

Utilizing hydrogen gas as an energy carrier and enabling a hydrogen economy is a promising step towards decarbonization. Water electrolysis is a key process in hydrogen generation, but electrolyzers face a couple technological hurdles before widespread integration could occur. Understanding morphology evolution and transport processes in an operating polymer electrolyte membrane (PEM) electrolyzer is key to reducing cost and increasing efficiency. In this study, combined operando X-ray computed tomography and radiography are used to study transport and degradation in PEM electrolyzers subject to applied current densities. Tomography enables three-dimensional steady-state imaging but does not capture transport subtleties. Radiography is limited to two-dimensions but does capture transient phenomena. The tomography results depict degradation of the catalyst layer on the anode side of the electrolyzer. The rate of degradation was observed to increase as the applied current density increased. The catalyst particle detachment is due to autonomous propulsion during the oxygen evolution reaction. Particles that mechanically rip off the membrane were observed to be redeposited into the porous transport layer. During radiography, sub-second exposure time is required to capture the transient behavior of oxygen evolution, even at the lower current densities (50-200 mAcm -2 ). Various flow regimes were observed in the channel ranging from bubbly to slug flow depending on current density. In conclusion, experimental observations agree with a model that an increase in current density increases oxygen bubble diameter and decreases bubble residence time within the electrolyzer channel.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving Distribution System Operations Using Fleet Control of Electrolyzers

The proliferation of electrolyzers presents an opportunity for grid operators. Fast response times and the use of hydrogen as storage can be leveraged in a symbiotic way to support increasing penetration levels of photovoltaics (PV) in the distribution grid. This work presents the grid integration of an electrolyzer fleet and its control applications to minimize the impact of increasing solar PV penetration in the distribution network. The study involves a feeder model of a real utility circuit from a utility partner with an operational model of a fleet of electrolyzers. The operational improvements are quantified with performance metrics. The metrics show that the fleet control application of the electrolyzers can aid in reducing overvoltages, voltage fluctuations, and control device operations induced by intermittent solar generation. The locational dependence of electrolyzers are also discussed in terms of performance metrics.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

Power Electronics for Electrolyzer Applications to Enable Grid Services

The Power Electronics for Electrolyzer Applications to Enable Grid Services project aims to develop smart converter for dedicated electrolyzer applications to enable grid services via standardization of control interfaces between hydrogen electrolyzer system low-level controls and power converter controls. The project provides additional revenue source for electrolyzer through participation in grid services and reduces the cost of deployment and controls integration through standardization and risk due to supply-chain issues. It also enables the adoption of green hydrogen via standardizing the integration of energy storage, renewables, and distributed energy resources. Furthermore, the work provides a controlled validation environment to evaluate scalable integration solution for hydrogen production technologies, improves overall reliability and maintainability of the electrolyzer system for grid applications, and directly contributes to DOE HFTO's "Hydrogen Shot" goal.

energy transitions↗

Using X-ray radiography to study oxygen flow in a proton exchange membrane electrolyzer operating under balanced pressure conditions

Of the various water electrolyzer technologies, the proton exchange membrane electrolyzer (PEMWE) is one of the best solutions for producing clean hydrogen without releasing CO 2 . In order to allow for widespread use of clean hydrogen, it is necessary to decrease its cost, which is intrinsically related to system operation. Current PEMWE plants operate in differential mode, directly pressurizing hydrogen and benefiting from thermodynamic compression, which increases overall system efficiency. However, high differential pressure above 30 bar can cause membrane stress, resulting in membrane creeping and failure. Pressurizing the water and operating at balanced pressure allows hydrogen to be produced at higher pressures while preserving the integrity of the membrane and porous layers. Nevertheless, the impact of pressurizing water on PEMWE performance must be better understood to maximize performance under balanced pressure conditions. Here, this study examined the impact of water pressure on two-phase flow. A high-pressure electrolyzer setup was developed to perform operando X-ray radiography and examine oxygen transport with high temporal resolution. The imaging segmentation process, developed to capture bubble properties in the channel, was applied to a specific experiment. The results clearly showed that as pressure increased up to 30 bars, the initial bubbly flow transitioned to slug flow, which led to channel saturation with oxygen. This work demonstrates that two-phase flow in an electrolyzer can be studied using X-ray radiography, which has the advantages of fast measurements and the ability to probe dense materials, such as those required for pressurized electrolyzers.

Balanced high pressure operation↗

Performance degradation in proton-conducting ceramic fuel cell and electrolyzer stacks

Proton-conducting ceramics are emerging as enabling materials for efficient electrochemical electricity generation, energy storage, and fuels synthesis. In this work, we present longer-term degradation results for protonic-ceramic fuel cells and electrolyzers based on a BaCe 0.4 Zr 0.4 Y 0.1 Yb 0.1 O 3-δ (BCZYYb) electrolyte. The cells are packaged within unit-cell stacks, including metallic interconnects, current collectors, sealing glasses and gaskets. Durability is found to be superior in protonic-ceramic electrolyzers in comparison to fuel cells. Operating conditions have a large impact on degradation rates; better stability is found at fuel-cell operating temperatures above 600 °C, and electrolyzer steam feeds below 20%. Here, we find that both fuel-cell and electrolyzer degradation is greatly reduced via the introduction of a gadolinium-doped ceria interlayer between the electrolyte and the air–steam electrode. Fuel-cell degradation falls to 1.2% khr –1 under methane fuel at 600 °C; electrolyzer degradation is reduced to 1% khr –1 at 550 °C and 50% steam. Further analyses of electrochemical impedance spectroscopy and distribution of relaxation times provide insight to root processes and degradation phenomena in protonic electroceramics.

25 ENERGY STORAGE↗

A carbon-efficient bicarbonate electrolyzer

Carbon efficiency is one of the most pressing problems of carbon dioxide electroreduction today. While there have been studies on anion exchange membrane electrolyzers with carbon dioxide (gas) and bipolar membrane electrolyzers with bicarbonate (aqueous) feedstocks, both suffer from low carbon efficiency. In anion exchange membrane electrolyzers, this is due to carbonate anion crossover, whereas in bipolar membrane electrolyzers, the exsolution of carbon dioxide (gas) from the bicarbonate solution is the culprit. Here, we first elucidate the root cause of the low carbon efficiency of liquid bicarbonate electrolyzers with thermodynamic calculations and then achieve carbon-efficient carbon dioxide electroreduction by adopting a near-neutral-pH cation exchange membrane, a glass fiber intermediate layer, and carbon dioxide (gas) partial pressure management. We convert highly concentrated bicarbonate solution to solid formate fuel with a yield (carbon efficiency) of greater than 96%. A device test is demonstrated at 100 mA cm -2 with a full-cell voltage of 3.1 V for over 200 h.

42 ENGINEERING↗

Pure-Water-Fed Forward-Bias Bipolar Membrane CO 2 Electrolyzer

Coupling renewable electricity to reduce carbon dioxide (CO 2 ) electrochemically into carbon feedstocks offers a promising pathway to produce chemical fuels sustainably. While there has been success in developing materials and theory for CO 2 reduction, the widespread deployment of CO 2 electrolyzers has been hindered by challenges in the reactor design and operational stability due to CO 2 crossover and (bi)carbonate salt precipitation. Herein, we design asymmetrical bipolar membranes assembled into a zero-gap CO 2 electrolyzer fed with pure water, solving both challenges. By investigating and optimizing the anion-exchangelayer thickness, cathode differential pressure, and cell temperature, the forward-bias bipolar membrane CO 2 electrolyzer achieves a CO faradic efficiency over 80% with a partial current density over 200 mA cm –2 at less than 3.0 V with negligible CO 2 crossover. In addition, this electrolyzer achieves 0.61 and 2.1 mV h –1 decay rates at 150 and 300 mA cm –2 for 200 and 100 h, respectively. Postmortem analysis indicates that the deterioration of catalyst/polymer– electrolyte interfaces resulted from catalyst structural change, and ionomer degradation at reductive potential shows the decay mechanism. Furthermore, all these results point to the future research direction and show a promising pathway to deploy CO 2 electrolyzers at scale for industrial applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pioneering Microporous Layers for Proton-Exchange-Membrane Water Electrolyzers via Tape Casting

The imperative shift towards decarbonization necessitates the production of clean hydrogen through water electrolysis, powered by renewable energy sources. Among electrolyzer technologies, proton-exchange-membrane (PEM) systems emerge as a promising option for large-scale hydrogen generation due to their modular design and rapid response, aligning well with the intermittency of renewable energy. In this study, we employ a tape casting method to fabricate microporous layers (MPLs), both as a single layer and as a bilayer over commercial porous transport layers (PTLs), to further enhance performance of water electrolyzers. We demonstrate that microporous layers require adequate pore sizes to facilitate gas removal, preventing gas flooding and preserving electrolyzer performance. Our single layer microporous layers exhibit lower overpotentials compared to commercial sintered Ti PTLs by 142 mV at 4 A·cm ⁻2 . Moreover, we show that having an effective microporous layer enhances electrolyzer performance irrespective of the substrate used, offering avenues for cost reduction. We also investigate novel PTL structures with reduced tortuosity and integrated MPL fabricated via phase inversion tape casting, resulting in a performance enhancement of 92 mV. Our findings unravel the critical role of microporous layer structures and their impact on electrolyzer performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CO2 Electrolyzer to Produce Formic Acid at Industry Relevant Current Density

Electrochemical CO2 reduction reaction (CO2RR) to produce formic acid has attracted great interest recently since formic acid can be used as a feedstock for biorefineries. Over the past decade, much effort has been devoted to the prospects of electrochemical CO2 conversion to formic acid. However, issues including low current density, low selectivity, low energy efficiency, poor long-term stability, and production of formate salts instead of formic acid remain as the great challenges for the development and commercialization of this technology. Recently, Dioxide Materials (DM) has developed an electrolyzer technology that can directly convert CO2 to pure formic acid with a three-compartment CO2 electrolyzer. In this work, DM will present our recent effort on improving the electrolyzer performance operating at industry relevant current density (200 mA/cm2). We have demonstrated 200 mA/cm² with 80% Faradaic efficiency for 1000 hours of operation. The effects of CO2 concentration and impurities in the flue gas on the electrolyzer performance will be discussed, as will ongoing efforts to test the device at a coal fired power plant. The long-term (1000 h) performance of the electrolyzer will also be presented.

Yang, Hongzhou↗

Hydrogen-oxygen proton-exchange membrane fuel cells and electrolyzers

Hydrogen-oxygen solid polymer electrolyte (SPE) fuel cells and SPE electrolyzers (products of Hamilton Standard) both use a Proton-Exchange Membrane (PEM) as the sole electrolyte. These solid electrolyte devices have been under continuous development for over 30 years. This experience has resulted in a demonstrated ten-year SPE cell life capability under load conditions. Ultimate life of PEM fuel cells and electrolyzers is primarily related to the chemical stability of the membrane. For perfluorocarbon proton exchange membranes an accurate measure of the membrane stability is the fluoride loss rate. Millions of cell hours have contributed to establishing a relationship between fluoride loss rates and average expected ultimate cell life. This relationship is shown. Several features have been introduced into SPE fuel cells and SPE electrolyzers such that applications requiring greater than or equal to 100,000 hours of life can be considered. Equally important as the ultimate life is the voltage stability of hydrogen-oxygen fuel cells and electrolyzers. Here again the features of SPE fuel cells and SPE electrolyzers have shown a cell voltage stability in the order of 1 microvolt per hour. That level of stability has been demonstrated for tens of thousands of hours in SPE fuel cells at up to 500 amps per square foot (ASF) current density.

Baldwin, R.↗

Electrolyzer Exergy Analysis for an Environmental Control and Life Support System

An exergy based analysis of the Environmental Control and Life Support System (ECLSS) aboard the International Space Station (ISS) is conducted to assess its overall performance. Exergy is chosen as a measure of performance because it accounts for both the first and second laws of thermodynamics. The exergy efficiency of a system is first defined as the total exergy destroyed by the system relative to the total exergy input to the system. To determine the ECLSS exergy efficiency, the system is divided into constituent subsystems which in turn are divided into assemblies and components. Based on this system decomposition, exergy balances are derived for each assembly or component. Exergy balances and supporting calculations are implemented in MATLAB® code. The major subsystems of the ECLSS considered in this analysis include the Atmosphere Revitalization Subsystem (ARS), Atmosphere Control and Supply Subsystem (ACS), Temperature and Humidity Control Subsystem (THC), Water Recovery and Management Subsystem (WRM), and Waste Management Subsystem (WM). This paper focuses on the ARS and its constituent assemblies and components. Exergy efficiency of the ARS and its constituent assemblies and components is first presented. The Oxygen Generation Assembly (OGA), an assembly within the ARS, is then highlighted because the exergy destruction by the OGA is a large magnitude contributor to the overall exergy destruction of the ECLSS. The OGA produces oxygen to meet the crew's metabolic demand via water electrolysis in a proton exchange membrane (PEM) electrolyzer. The exergy destruction of the OGA's PEM electrolyzer is a function of the amount of oxygen produced, which determines the necessary current density and voltage drop across the PEM electrolyzer. In addition, oxygen production in the PEM electrolyzer requires deviation from the Nernst potential, presenting trade-offs between the exergy efficiency and critical life support functions. The results of parametric studies of PEM electrolyzer performance are presented with an emphasis on the impacts of polarization and operational conditions on exergy efficiency.

Chow, Raymond↗

Life-cycle analysis of hydrogen production from water electrolyzers

The United States' focus on decarbonization has spawned interest among policymakers in deploying water electrolysis technology for clean hydrogen production. However, water electrolyzers also raise concerns regarding their substantial use of carbon-intensive materials. Here, we conduct a comprehensive life-cycle analysis (LCA) of three prominent water electrolyzer technologies to investigate the environmental implications of their manufacturing and life cycles under different energy sources. All electrolyzer technologies employing low-carbon energy (nuclear, solar, or wind) exhibit life-cycle greenhouse gas (GHG) emissions of 0.3-2.4 kg-CO 2-eq /kg-H 2 . This is significantly lower than the corresponding GHG emissions for hydrogen production via both conventional steam methane reforming and alternative autothermal reforming with carbon capture and storage (by > 50%). The well-to-gate GHG emissions of low-carbon electrolyzers (0-0.36 kg-CO 2-eq / kg-H 2 ) qualify for Tier I of the production tax credit in the U.S.' Inflation Reduction Act of 2022, indicating their suitability for producing decarbonized hydrogen under this program.

08 HYDROGEN↗

CRADA Final Report For CRADA NO. CR-12-006 [Operation and Testing of an SO 2 -depolarized Electrolyzer (SDE) for the Purpose of Hydrogen and Sulfuric Acid Production]

Over the past several years, Savannah River National Laboratory (SRNL) has led a team of collaborators under the Department of Energy’s (DOE) nuclear hydrogen production program to develop the Hybrid Sulfur (HyS) Process. HyS is a 2-step water-splitting process consisting of high temperature decomposition of sulfuric acid to generate SO 2 , followed by the electrolysis of aqueous SO 2 to generate hydrogen and sulfuric acid. The latter is fed back into the high temperature reactor. SRNL designed and built an SO 2 -depolarized electrolyzer (SDE) and a test facility. Over 40 SDE’s were tested using different catalysts, membranes and other components. SRNL demonstrated that an SDE could be operated continuously for approximately 200 hours under certain conditions without buildup of sulfur at the SDE’s cathode, thus solving a key technical problem with SDE technology. Air Products and Chemicals, Inc. (APCI) is a major supplier of hydrogen production systems, and they have proprietary technology that could benefit from the SDE developed by SRNS, or some improved version thereof. However, to demonstrate that SRNL’s SDE is a truly viable approach to the electrolyzer design, continuous operation for far greater periods of time than 200 hours must be demonstrated, and the electrolyzer must be scaled up to greater hydrogen production capacities. SRNL and Air Products entered into a Cooperative Research and Development Agreement with the objective of demonstrating the effectiveness of the SDE for hydrogen and sulfuric acid production and to demonstrate long-term continuous operation so as to dramatically increase the confidence in the SDE design for commercial operation. SRNL prepared a detailed technical report documenting previous SDE development, including the current SDE design and operating conditions that led to the 200-hour sulfurfree testing. SRNL refurbished its single cell SDE test facility and qualified the equipment for continuous operation. A new membrane electrode assembly (MEA) was fabricated and installed in the single cell electrolyzer (60 cm 2 active cell area). Shakedown testing was conducted, and several modifications were made to the test facility equipment. Seven different MEAs were used during testing. Beginning on May 20, 2013, SRNL was able to test the SDE continuously for 1200 hours, including 1000 hours under power to generate hydrogen at an average rate of 10.8 liters per hour. The SDE was not removed or repaired during the 50-day test and was successfully restarted after each shutdown. The test was intentionally stopped after 1200 hours (1000 hours of hydrogen production) due to funding constraints. Post-test examination of the MEA using Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray Microanalysis (EDAX) showed no elemental sulfur deposits or sulfur layer inside the cell, thus successfully achieving the test goals. The results demonstrated that the SDE could be operated for extended periods without major performance degradation or the buildup of sulfur inside the MEA. Air Products conducted an assessment of the economic viability of the SDE based on the “as tested” design. The results indicated that the SDE faces significant economic obstacles in its current state. Further development and scale-up are necessary before the SDE is ready for commercialization.

08 HYDROGEN↗

Vapor–Fed Electrolyzers for Carbon Dioxide Reduction Using Tandem Electrocatalysts: Cuprous Oxide Coupled with Nickel–Coordinated Nitrogen–Doped Carbon

We report ethylene is particularly attractive due to its major importance as a feedstock for various applications including the polymer industry. As such, catalyst and electrolyzer developments are crucial to achieve industrially relevant ethylene production and efficiency levels. In this work, a tandem electrocatalyst composed of copper nanocubes and nickel-coordinated nitrogen-doped carbon (NiNC) is presented, which is integrated into gas diffusion electrodes (GDEs) for direct conversion of vapor-fed CO 2 into ethylene. Evaluation of tandem GDEs in the vapor-fed flow electrolyzer shows significantly increased ethylene selectivity in terms of faradaic efficiency and C 2 H 4 /CO ratio compared to a non-tandem copper GDE. The enhancements are attributed to the increased local CO availability near the copper surface via effective CO 2 to CO conversion on neighboring NiNC. The experimental results are validated by 3D resolved continuum simulations, which show increased flux of higher-order prod-ucts with the added CO flux from NiNC. The practical viability of Cu/NiNC catalyst is further evaluated in a membrane electrode assembly electrolyzer, achieving 40% FE toward ethylene at 150 mA cm -2 and 3.2 V. These find-ings highlight the high selectivity and formation rate of ethylene achieved by successful device integration of the Cu/NiNC catalyst, demonstrating the potential for implementation in large-scale sustainable CO 2 electrolyzers.

36 MATERIALS SCIENCE↗

In-situ and in-operando analysis of voltage losses using sense wires for proton exchange membrane water electrolyzers

Proton exchange membrane water electrolyzer development requires understanding processes at the materials and interface levels to reach the required performance and lifetime targets for increasing market penetration. To achieve the required progress, it is critical to develop advanced in-situ diagnostics that allow observation of the changes that come with the reduction of catalyst loading combined with long-term intermittent operation. This work presents an internal voltage sensing method that enables observing internal voltage drops in an operating electrolyzer cell. It allows the total cell resistance to be separated into anode, CCM, and cathode resistance. The method is demonstrated by operating cells with different anode porous transport layers (PTLs). The changing properties of the PTLs result in significant variations of the resistances. Enhancing the PTL properties with a protective coating reduces the anode resistance significantly. In addition to these observations, the method enables a real-time monitoring of resistance related values that impact performance in water electrolyzers. Long-term experiments with the method allow us to gain insights into processes that occur during operation such as conditioning or degradation. The internal voltage sensing method presented in this study is a novel technique for diagnosing, analyzing, and optimizing water electrolyzers and other energy conversion devices.

42 ENGINEERING↗