Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Fluctuation theorem for a double quantum dot coupled to a point-contact electrometer

Motivated by recent experiments on the real-time single-electron counting through a semiconductor GaAs double quantum dot (DQD) by a nearby quantum point contact (QPC), we develop the full-counting statistics of coupled DQD and QPC system. By utilizing the time-scale separation between the dynamics of DQD and QPC, we derive the modified master equation with tunneling rates depending on the counting fields, which fulfill the detailed fluctuation theorem. Furthermore, we derive universal relations between the non-linear corrections to the current and noise, which can be verified in experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrostatic Regolith Interaction Experiment (ERIE) Electrometer Instrument Development

The Electrostatic Regolith Interaction Experiment (ERIE) is a joint venture between the University of Central Florida (UCF) Center for Microgravity Research (CMR) and the NASA Kennedy Space Center (KSC) Electrostatics and Surface Physics Laboratory (ESPL) seeking to examine charged dust grain behavior in a microgravity environment. Two separate systems have been combined for this suborbital flight experiment: the COLLisions Into Dust Experiment (COLLIDE) developed by the UCF CMR and the Wheel Electrostatic Spectrometer (WES) developed by the NASA KSC ESPL. This combination will advance the understanding of the natural and induced charged grain behavior on the Moon, asteroids, and other low gravity bodies comprised of charged dust particles.

Electrostatics↗

Miniature electrometer preamplifier effectively compensates for input capacitance

Negative capacitance preamplifier using a dual MOS /Metal Oxide Silicon/ transistor in conjunction with bipolar transistors is used with intracellular microelectrodes in recording bioelectric potentials. Applications would include use as a pickup plate video amplifier in storage tube tests and for pH and ionization chamber measurements.

Burrous, C. N.↗

Advances in electrometer vacuum tube design

Single-ended, miniature-cathode tube with a relatively low grid current level is constructed. Adequate cathode temperature at relatively low heater power drain is provided by designing the supporting spacers to provide a square cathode hole. Method of assembling the mount and bonding the elements is discussed.

Source record↗

Electrometer Amplifier With Overload Protection

Circuit features low noise, input offset, and high linearity. Input preamplifier includes input-overload protection and nulling circuit to subtract dc offset from output. Prototype dc amplifier designed for use with ion detector has features desirable in general laboratory and field instrumentation.

Woeller, F. H.↗

A Wheel Electrometer to Measure Electrostatic Fields on the Martian Surface

A system of embedded sensors that can be incorporated into the wheel of any future mission rover would provide for a simple and fairly unobtrusive way to measure the distribution of electrostatic fields on the Martian surface and to measure variations in soil electrostatic response. This technology could perhaps be applied to different types of sensors that require the mobility provided by a rover s wheel.

C.I. Calle↗

Multi-sensor electrometer

An array of triboelectric sensors is used for testing the electrostatic properties of a remote environment. The sensors may be mounted in the heel of a robot arm scoop. To determine the triboelectric properties of a planet surface, the robot arm scoop may be rubbed on the soil of the planet and the triboelectrically developed charge measured. By having an array of sensors, different insulating materials may be measured simultaneously. The insulating materials may be selected so their triboelectric properties cover a desired range. By mounting the sensor on a robot arm scoop, the measurements can be obtained during an unmanned mission.

Gompf, Raymond↗

MECA/Electrometer

The commercially available electrometers are typically used to survey for ESD (Electrostatic Discharge) prone materials in electronic component assembly areas. These instruments operate using either DC (direct current) or AC (alternating current). This description is concerned with a DC electrometer. The critical components are the detecting electrode, the input capacitance, operation amplifier (op amp), a shorting switch used to zero the instrument, and the charged surface. DC Instruments are used to measure the change in charge placed in front of the instruments detecting electrode after instrument is zeroed. These instruments -have the feature that the input voltage will drift with time. This drift is typically hours in duration and depends on the op amp input current. The conventional ESD survey instrument. During a measurement, the conventional electrometer is held at a known distance from a charged surface. The now DC electrometer, is used in a different manner than ESD survey instrument. In the new instrument, triboelectric materials are placed in contact with the surface to be measured, rubbed against the surface, removed from the surface, and the triboelectrically-induced charge measured. Thus, the distance between the charged surface and the detecting electrode is a known distance leading to a direct measure of the electric field and deposited charge.

Buehler, Martin↗

A Study of the Electrostatic Interaction Between Insulators and Martian/Lunar Soil Simulants

Using our previous experience with the Mars Environmental Compatibility Assessment (MECA) electrometer, we have designed a new type of aerodynamic electrometer. The goal of the research was to measure the buildup of electrostatic surface charge on a stationary cylindrical insulator after windborne granular particles have collided with the insulator surface in a simulated dust storm. The experiments are performed inside a vacuum chamber. This allows the atmospheric composition and pressure to be controlled in order to simulate the atmospheric conditions near the equator on the Martian surface. An impeller fan was used to propel the dust particles at a cylindrically shaped insulator under low vacuum conditions. We tested the new electrometer in a 10 mbar CO2 atmosphere by exposing two types of cylindrical insulators, Teflon (1.9 cm diameter) and Fiberglass (2.5 cm diameter), to a variety of windborne granular particulate materials. The granular materials tested were JSC Mars-1 simulant, which is a mixture of coarse and fine (<5microns diameter) particle sizes, and some of the major mineral constituents of the Martian soil. The minerals included Ottawa sand (SiO2), iron oxide (Fe2O3), aluminum oxide (Al2O3) and magnesium oxide (MgO). We also constructed a MECA-like electrometer that contained an insulator capped planar electrode for measuring the amount of electrostatic charge produced by rubbing an insulator surface over Martian and lunar soil simulants. The results of this study indicate that it is possible to detect triboelectric charging of insulator surfaces by windborne Martian soil simulant, and by individual mineral constituents of the soil simulant. We have also found that Teflon and Fiberglass insulator surfaces respond in different ways by developing opposite polarity surface charge, which decays at different rates after the particle impacts cease.

Mantovani, James G.↗

SU-E-T-451: Accuracy and Application of the Standard Imaging W1 Scintillator Dosimeter

Purpose: To evaluate the Standard Imaging W1 scintillator dosimeter in a range of clinical radiation beams to determine its range of possible applications. Methods: The W1 scintillator is a small perturbation-free dosimeter which is of interest in absolute and relative clinical dosimetry due to its small size and water equivalence. A single version of this detector was evaluated in Co-60 and linac photon and electron beams to investigate the following: linearity, sensitivity, precision, and dependence on electrometer type. In addition, depth-dose and cross-plane profiles were obtained in both photon and electron beams and compared with data obtained with wellbehaved ionization chambers. Results: In linac beams the precision and linearity was very impressive, with typical values of 0.3% and 0.1% respectively. Performance in a Co-60 beam was much poorer (approximately three times worse) and it is not clear whether this is due to the lower signal current or the effect of the continuous beam (rather than pulsed beam of the linac measurements). There was no significant difference in the detector reading when using either the recommended SI Supermax electrometer or two independent high-quality electrometers, except for low signal levels, where the Supermax exhibited an apparent threshold effect, preventing the measurement of the bremsstrahlung background in electron depth-dose curves. Comparisons with ion chamber measurements in linac beams were somewhat variable: good agreement was seen for cross-profiles (photon and electron beams) and electron beam depth-dose curves, generally within the 0.3% precision of the scintillator but systematic differences were observed as a function of measurement depth in photon beam depth-dose curves. Conclusion: A first look would suggest that the W1 scintillator has applications beyond small field dosimetry but performance appears to be limited to higher doserate and/or pulsed radiation beams. Further work is required to resolve discrepancies compared to ion chambers.

60 APPLIED LIFE SCIENCES↗

TH-C-19A-08: PDD Discrepancies at Opposite Biases From Very Small Volume Ion Chambers When Using Water Scanners

Purpose: As more so-called micro ion chambers become commercially available, medical physicists may be inclined to use them during the linear accelerator commissioning process, in an attempt to better characterize the beam in steep dose gradient areas. The purpose of this work is to inform the medical physics community of a non-trivial, anomalous behavior observed when very small chambers are used in certain beam scanning configurations. Methods: A total of six ion chambers (0.007cc to 0.6cc) were used to scan PDDs from a 10×10cm2 field at both +300V and −300V biases. PDDs were scanned using three different water tank scanning systems to determine whether different scanners exhibit the same abnormality. Finally, PDDs were sampled using an external electrometer to bypass the internal electrometer of the scanner to determine the potential contributions of the scanner electronics to the abnormality observed. Results: We observed a reproducible, significant difference (over-response with depth) in PDDs acquired when using very small ion chambers with certain bias and watertank combinations, on the order of 3–5% at a depth of 25 cm in water. This difference was not observed when the PDDs were sampled using the ion chambers in conjunction with an external electrometer. This suggests a contribution of interference produced by the controller box and scanning system, which becomes significant for the very small signals collected by very small ion chambers, especially at depth, as the signal level is reduced even further. Conclusion: Based on the results observed here, if currently available very small ion chambers are used with specific bias and scanning water-tank combinations, erroneous PDD data may be collected. If this data is used as input to the Treatment Planning System, systematic errors on the order of 3%–5% may be introduced into the treatment planning process.

07 ISOTOPE AND RADIATION SOURCES↗