Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron charge device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Chromatic-free spatially resolved optical emission spectroscopy diagnostics for microplasma

A chromatic-free spatially resolved diagnostic system for microplasma measurement is proposed and demonstrated, which consists of an optical chromatic-free microscope mirror system, an electron multiplying charge coupled device (EMCCD), and bandpass filters. The diagnostic system free of chromatic aberrations with a spatial resolution of about 6 {mu}m is achieved. The factors that limit the resolution of this diagnostic system have been analyzed, which are optical diffraction, the pixel size of the EMCCD, and the thickness of the microplasma. In this paper, the optimal condition for achieving a maximum resolution power has been analyzed. With this diagnostic system, we revealed the spatial nonuniformity of a microwave atmospheric-pressure argon microplasma. Furthermore, the spatial distribution of the time-averaged effective electron temperature has been estimated from the intensity distributions of 750.4 and 415.8 nm emissions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of first hard X-ray pulse at Tsinghua Thomson Scattering X-ray Source

Tsinghua Thomson Scattering X-ray Source (TTX) is the first-of-its-kind dedicated hard X-ray source in China based on the Thomson scattering between a terawatt ultrashort laser and relativistic electron beams. In this paper, we report the experimental generation and characterization of the first hard X-ray pulses (51.7 keV) via head-on collision of an 800 nm laser and 46.7 MeV electron beams. The measured yield is 1.0 Multiplication-Sign 10{sup 6} per pulse with an electron bunch charge of 200 pC and laser pulse energy of 300 mJ. The angular intensity distribution and energy spectra of the X-ray pulse are measured with an electron-multiplying charge-coupled device using a CsI scintillator and silicon attenuators. These measurements agree well with theoretical and simulation predictions. An imaging test using the X-ray pulse at the TTX is also presented.

43 PARTICLE ACCELERATORS↗

Application of an EMCCD Camera for Calibration of Hard X-Ray Telescopes

Recent technological innovations now make it feasible to construct hard x-ray telescopes for space-based astronomical missions. Focusing optics are capable of improving the sensitivity in the energy range above 10 keV by orders of magnitude compared to previously used instruments. The last decade has seen focusing optics developed for balloon experiments and they will soon be implemented in approved space missions such as the Nuclear Spectroscopic Telescope Array (NuSTAR) and ASTRO-H. The full characterization of x-ray optics for astrophysical and solar imaging missions, including measurement of the point spread function (PSF) as well as scattering and reflectivity properties of substrate coatings, requires a very high spatial resolution, high sensitivity, photon counting and energy discriminating, large area detector. Novel back-thinned Electron Multiplying Charge-Coupled Devices (EMCCDs) are highly suitable detectors for ground-based calibrations. Their chip can be optically coupled to a microcolumnar CsI(Tl) scintillator via a fiberoptic taper. Not only does this device exhibit low noise and high spatial resolution inherent to CCDs, but the EMCCD is also able to handle high frame rates due to its controllable internal gain. Additionally, thick CsI(Tl) yields high detection efficiency for x-rays. This type of detector has already proven to be a unique device very suitable for calibrations in astrophysics: such a camera was used to support the characterization of the performance for all NuSTAR optics. Further optimization will enable similar cameras to be improved and used to calibrate x-ray telescopes for future space missions. In this paper, we discuss the advantages of using an EMCCD to calibrate hard x-ray optics. We will illustrate the promising features of this detector solution using examples of data obtained during the ground calibration of the NuSTAR telescopes performed at Columbia University during 2010/2011. Finally, we give an outlook on ongoing development and optimizations, such as the use of single photon counting mode to enhance spectral resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resistance drift in Ge 2 Sb 2 Te 5 phase change memory line cells at low temperatures and its response to photoexcitation

Resistance drift in amorphous Ge 2 Sb 2 Te 5 is experimentally characterized in melt-quenched line cells in the range of 300 K to 125 K and is observed to follow the previously reported power-law behavior with drift coefficients in the range of 0.07 to 0.11 in the dark, linearly decreasing with 1/kT. While these drift coefficients measured in the dark are similar to commonly observed drift coefficients (~0.1) at and above room temperature, measurements under light show a significantly lower drift coefficient (0.05 under illumination vs 0.09 in the dark at 150 K). Periodic on/off switching of light shows a sudden decrease/increase in resistance, attributed to photo-excited carriers, followed by a very slow response (~30 min at 150 K) attributed to contribution of electron traps and slow trap-to-trap charge exchanges. A device-level electronic model is used to relate these experimental findings to gradual charging of electron traps in amorphous Ge 2 Sb 2 Te 5 , which gives rise to growth of a potential barrier for holes in time and, hence, resistance drift.

42 ENGINEERING↗

Trends in solid state electronics, part 2

Developments in the fields of semiconductors and magnetics are surveyed. Materials, devices, theory, and fabrication technology are discussed. Important events up until the present time are reported, and events are interpreted through historical perspective. A brief analysis of forces which have driven the development of today's electronic technology and some projections of present trends are given. More detailed discussions are presented for four areas of contemporary interest: amorphous semiconductors, bubble domain devices, charge-coupled devices, and electron and ion beam techniques. Beam addressed magnetic memories are reviewed to a lesser extent.

Gassaway, J. D.↗

Probing single electron scattering through a non-Fermi-liquid charge-Kondo device

Among the exotic and yet unobserved features of multichannel Kondo impurity models is their subunitary single electron scattering. In the two-channel Kondo model, for example, an incoming electron is fully scattered into a many-body excitation such that the single particle Green's function vanishes. Here, we propose to directly observe these features in a charge-Kondo device encapsulated in a Mach-Zehnder interferometer, within a device already studied by Duprez et al. [Science 366, 1243 (2019)]. Finally, we provide detailed predictions for the visibility and phase of the Aharonov-Bohm oscillations depending on the number of coupled channels and the asymmetry of their couplings.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Luminescence evolution from alumina ceramic surface before flashover under direct and alternating current voltage in vacuum

The luminescence evolution phenomena from alumina ceramic surface in vacuum under high voltage of direct and alternating current are reported, with the voltage covering a large range from far below to close to the flashover voltage. Its time resolved and spatial distributed behaviors are examined by a photon counting system and an electron-multiplying charge-coupled device (EMCCD) together with a digital camera, respectively. The luminescence before flashover exhibits two stages as voltage increasing, i.e., under a relative low voltage (Stage A), the luminescence is ascribed to radiative recombination of hetero-charges injected into the sample surface layer by Schottky effect; under a higher voltage (Stage B), a stable secondary electron emission process, resulting from the Fowler-Nordheim emission at the cathode triple junction (CTJ), is responsible for the luminescence. Spectrum analysis implies that inner secondary electrons within the surface layer of alumina generated during the SSEE process also participate in the luminescence of Stage B. A comprehensive interpretation of the flashover process is formulated, which might promote a better understanding of flashover issue in vacuum.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron-bombarded CCD detectors for ultraviolet atmospheric remote sensing

Electronic image sensors based on charge coupled devices operated in electron-bombarded mode, yielding real-time, remote-readout, photon-limited UV imaging capability are being developed. The sensors also incorporate fast-focal-ratio Schmidt optics and opaque photocathodes, giving nearly the ultimate possible diffuse-source sensitivity. They can be used for direct imagery of atmospheric emission phenomena, and for imaging spectrography with moderate spatial and spectral resolution. The current state of instrument development, laboratory results, planned future developments and proposed applications of the sensors in space flight instrumentation is described.

Carruthers, G. R.↗

Gamma-ray momentum reconstruction from Compton electron trajectories by filtered back-projection

Gamma-ray imaging utilizing Compton scattering has traditionally relied on measuring coincident gamma-ray interactions to map directional information of the source distribution. This coincidence requirement makes it an inherently inefficient process. We present an approach to gamma-ray reconstruction from Compton scattering that requires only a single electron tracking detector, thus removing the coincidence requirement. From the Compton scattered electron momentum distribution, our algorithm analytically computes the incident photon's correlated direction and energy distributions. Because this method maps the source energy and location, it is useful in applications, where prior information about the source distribution is unknown. We demonstrate this method with electron tracks measured in a scientific Si charge coupled device. While this method was demonstrated with electron tracks in a Si-based detector, it is applicable to any detector that can measure electron direction and energy, or equivalently the electron momentum. For example, it can increase the sensitivity to obtain energy and direction in gas-based systems that suffer from limited efficiency.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging Fluorescence-Correlation Spectroscopy for Measuring Fast Surface Diffusion at Liquid/Solid Interfaces

The development of techniques to probe interfacial molecular transport is important for understanding and optimizing surface-based analytical methods including surface-enhanced spectroscopies, biological assays, and chemical separations. Single-molecule-fluorescence imaging and tracking has been used to measure lateral diffusion rates of fluorescent molecules at surfaces, but the technique is limited to the study of slower diffusion, where molecules must remain relatively stationary during acquisition of an image in order to build up sufficient intensity in a spot to detect and localize the molecule. Although faster time resolution can be achieved by fluorescence-correlation spectroscopy (FCS), where intensity fluctuations in a small spot are related to the motions of molecules on the surface, long-lived adsorption events arising from surface inhomogeneity can overwhelm the correlation measurement and mask the surface diffusion of the moving population. Here, we exploit a combination of these two techniques, imaging-FCS, for measurement of fast interfacial transport at a model chromatographic surface. This is accomplished by rapid imaging of the surface using an electron-multiplied-charged-coupled-device (CCD) camera, while limiting the acquisition to a small area on the camera to allow fast framing rates. The total intensity from the sampled region is autocorrelated to determine surface diffusion rates of molecules with millisecond time resolution. Here, the technique allows electronic control over the acquisition region, which can be used to avoid strong adsorption sites and thus minimize their contribution to the measured autocorrelation decay and to vary the acquisition area to resolve surface diffusion from adsorption and desorption kinetics. As proof of concept, imaging-FCS was used to measure surface diffusion rates, interfacial populations, and adsorption–desorption rates of 1,1'-dioctadecyl-3,3,3'3'-tetramethylindocarbocyanine (DiI) on planar C18- and C1-modified surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of atomic and molecular mega-electron-volt projectiles using an x-ray charged coupled device camera

We show that an x-ray charge coupled device (CCD) may be used as a particle detector for atomic and molecular mega-electron-volt (MeV) projectiles of around a few hundred keV per atomic mass unit. For atomic species, spectroscopic properties in kinetic energy measurements (i.e., linearity and energy resolution) are found to be close to those currently obtained with implanted or surface barrier silicon particle detectors. For molecular species, in order to increase the maximum kinetic energy detection limit, we propose to put a thin foil in front of the CCD. This foil breaks up the molecules into atoms and spreads the charges over many CCD pixels and therefore avoiding saturation effects. This opens new perspectives in high velocity molecular dissociation studies with accelerator facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomically Thin Mesoporous Co 3 O 4 Layers Strongly Coupled with N-rGO Nanosheets as High-Performance Bifunctional Catalysts for 1D Knittable Zinc-Air Batteries [Atomically Thin Mesoporous Co 3 O 4 /N-rGO Nanosheets as the Bifunctional Catalysts for One-Dimensional Knittable Zinc-Air Batteries]

Here, under development for next–generation wearable electronics are flexible, knittable, and wearable energy–storage devices with high energy density that can be integrated into textiles. Herein, knittable fiber–shaped zinc–air batteries with high volumetric energy density (36.1 mWh cm –3 ) are fabricated via a facile and continuous method with low–cost materials. Furthermore, a high–yield method is developed to prepare the key component of the fiber–shaped zinc–air battery, i.e., a bifunctional catalyst composed of atomically thin layer–by–layer mesoporous Co 3 O 4 /nitrogen–doped reduced graphene oxide (N–rGO) nanosheets. Benefiting from the high surface area, mesoporous structure, and strong synergetic effect between the Co 3 O 4 and N–rGO nanosheets, the bifunctional catalyst exhibits high activity and superior durability for oxygen reduction and evolution reactions. Compared to a fiber–shaped zinc–air battery using state–of–the–art Pt/C + RuO 2 catalysts, the battery based on these Co 3 O 4 /N–rGO nanosheets demonstrates enhanced and stable electrochemical performance, even under severe deformation. Such batteries, for the first time, can be successfully knitted into clothes without short circuits under external forces and can power various electronic devices and even charge a cellphone.

36 MATERIALS SCIENCE↗

Analysis of the EMCCD point-source response using x-rays

Electron Multiplying Charge Coupled Devices, EMCCD are used as x-ray detectors. The NSLS-II Soft Inelastic x-ray Scattering (SIX) beam line has two EMCCDs for x-ray detection in the spectrometer arm. The spectrometer with high resolving power disperses x-rays vertically. The x-ray vertical position on the sensor plane is related to its energy. This allows for very accurate x-ray energy measurements through x-ray coordinates. X-rays interact with silicon and create a number of electron-hole pairs proportional to the x-ray energy. Electrons drift and diffuse toward pixel gates and are collected there. The diffused electrons form a charge cloud distributed over several neighboring pixels. This charge sharing enables coordinate measurements with accuracy better than the pixel pitch. The charge distribution shape has to be taken into account to achieve ultimate accuracy in coordinate measurements. In this paper, we present a method of the charge distribution shape analysis and demonstrate its applications. The drift and diffusion of electrons ftom the point of generation to pixel gates results in the bell-shaped electron cloud usually approximated by Gaussian shape. The number of electrons collected under a pixel is proportional to the shape function integral. These electron packets get transferred to the sense node of the output amplifier. The transfer process could introduce distortions to the original charge distribution. For example, during transfers, electrons in the packet could be exposed to traps if they are present in the sensor. The trapping and later the release processes distort the apparent shape of the charge distribution. Therefore, deviations of the charge distribution shape ftom the originally symmetrical form can indicate the presence of trap centers in the sensor and can be used for sensor diagnostics.

47 OTHER INSTRUMENTATION↗

Angular distribution of atoms emitted from a SrZrO{sub 3} target by laser ablation under different laser fluences and oxygen pressures

Angular distributions of atoms emitted by laser ablation of perovskite-type oxide SrZrO{sub 3} have been investigated using electron probe microanalysis with wavelength-dispersive spectroscopy and charge-coupled device photography with an interference filter. Each constituent element has been analyzed as a two-modal distribution composed of a broad cos{sup m} {theta} distribution and a narrow cos{sup n} {theta} distribution. The exponent n characterizes the component of laser ablation while the exponent m characterizes that of thermal evaporation, where a larger n or m means a narrower angular distribution. In vacuum, O (n=6) showed a broader distribution than those of Sr (n=16) and Zr (n=17), and Sr{sup +} exhibited a spatial distribution similar to that of Sr. As the laser fluence was increased from 1.1 to 4.4 J/cm{sup 2}, the angular distribution of Sr became narrower. In the laser fluence range of 1.1-4.4 J/cm{sup 2}, broadening of the angular distribution of Sr was observed only at the fluence of 1.1 J/cm{sup 2} under the oxygen pressure of 10 Pa. Monte Carlo simulations were performed to estimate approximately the energy of emitted atoms, focusing on the broadening of the angular distribution under the oxygen pressure of 10 Pa. The energies of emitted atoms were estimated to be 1-20 eV for the laser fluence of 1.1 J/cm{sup 2}, and more than 100 eV for 2.2 and 4.4 J/cm{sup 2}.

36 MATERIALS SCIENCE↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

Measurement of low energy ionization signals from Compton scattering in a charge-coupled device dark matter detector [Measurement of low energy ionization signals from Compton scattering in a CCD dark matter detector]

In this paper, an important source of background in direct searches for low-mass dark matter particles are the energy deposits by small-angle scattering of environmental γ rays. We report detailed measurements of low-energy spectra from Compton scattering of γ rays in the bulk silicon of a charge-coupled device (CCD). Electron recoils produced by γ rays from 57 Co and 241 Am radioactive sources are measured between 60 eV and 4 keV. The observed spectra agree qualitatively with theoretical predictions, and characteristic spectral features associated with the atomic structure of the silicon target are accurately measured for the first time. A theoretically motivated parametrization of the data that describes the Compton spectrum at low energies for any incident γ-ray flux is derived. The result is directly applicable to background estimations for low-mass dark matter direct-detection experiments based on silicon detectors, in particular for the DAMIC experiment down to its current energy threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Smart Readout of Nondestructive Image Sensors with Single Photon-Electron Sensitivity

Image sensors with nondestructive charge readout provide single-photon or single-electron sensitivity, but at the cost of long readout times. We present a smart readout technique to allow the use of these sensors in visible light and other applications that require faster readout times. The method optimizes the readout noise and time by changing the number of times pixels are read out either statically, by defining an arbitrary number of regions of interest in the array, or dynamically, depending on the charge or energy of interest in the pixel. This technique is tested in a Skipper CCD showing that it is possible to obtain deep subelectron noise, and therefore, high resolution of quantized charge, while dynamically changing the readout noise of the sensor. These faster, low noise readout techniques show that the skipper CCD is a competitive technology even where other technologies such as electron multiplier charge coupled devices, silicon photo multipliers, etc. are currently used. This technique could allow skipper CCDs to benefit new astronomical instruments, quantum imaging, exoplanet search and study, and quantum metrology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-CAMPUS-I-05: Investigation of An EMCCD Detector with Variable Gain in a Micro-CT System

Purpose: To investigate the performance of a newly built Electron Multiplying Charged Coupled Device (EMCCD) based Micro-CT system, with variable detector gain, using a phantom containing contrast agent of different concentrations. Methods: We built a micro- CT system with an EMCCD having 8 microns pixels and on-chip variable gain. We tested the system using a phantom containing five tubes filled with different iodine contrast solutions (30% to 70%). First, we scanned the phantom using various x-ray exposures values at 40 kVp and constant detector gain. Next, for the same tube currents, the detector gain was increased to maintain the air value of the projection image constant. A standard FDK algorithm was used to reconstruct the data. Performance was analyzed by comparing the signal-to-noise ratio (SNR) measurements for increased gain with those for the low constant gain at each exposure. Results: The high detector gain reconstructed data SNR was always greater than the low gain data SNR for all x-ray settings and for all iodine features. The largest increases were observed for low contrast features, 30% iodine concentration, where the SNR improvement approached 2. Conclusion: One of the first implementations of an EMCCD based micro- CT system was presented and used to image a phantom with various iodine solution concentrations. The analysis of the reconstructed volumes showed a significant improvement of the SNR especially for low contrast features. The unique on-chip gain feature is a substantial benefit allowing the use of the system at very low x-ray exposures per frame.Partial support: NIH grant R01EB002873 and Toshiba Medical Systems Corp. Partial support: NIH grant R01EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗