Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron streaking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Simultaneous Spectral Temporal Adaptive Raman Spectrometer - SSTARS

Raman spectroscopy is a prime candidate for the next generation of planetary instruments, as it addresses the primary goal of mineralogical analysis, which is structure and composition. However, large fluorescence return from many mineral samples under visible light excitation can render Raman spectra unattainable. Using the described approach, Raman and fluorescence, which occur on different time scales, can be simultaneously obtained from mineral samples using a compact instrument in a planetary environment. This new approach is taken based on the use of time-resolved spectroscopy for removing the fluorescence background from Raman spectra in the laboratory. In the SSTARS instrument, a visible excitation source (a green, pulsed laser) is used to generate Raman and fluorescence signals in a mineral sample. A spectral notch filter eliminates the directly reflected beam. A grating then disperses the signal spectrally, and a streak camera provides temporal resolution. The output of the streak camera is imaged on the CCD (charge-coupled device), and the data are read out electronically. By adjusting the sweep speed of the streak camera, anywhere from picoseconds to milliseconds, it is possible to resolve Raman spectra from numerous fluorescence spectra in the same sample. The key features of SSTARS include a compact streak tube capable of picosecond time resolution for collection of simultaneous spectral and temporal information, adaptive streak tube electronics that can rapidly change from one sweep rate to another over ranges of picoseconds to milliseconds, enabling collection of both Raman and fluorescence signatures versus time and wavelength, and Synchroscan integration that allows for a compact, low-power laser without compromising ultimate sensitivity.

Blacksberg, Jordana↗

Improving accuracy of electron density measurement in the presence of metallic implants using orthovoltage computed tomography

The goal of this study was to evaluate the improvement in electron density measurement and metal artifact reduction using orthovoltage computed tomography (OVCT) imaging compared with conventional kilovoltage CT (KVCT). For this study, a bench-top system was constructed with adjustable x-ray tube voltage up to 320 kVp. A commercial tissue-characterization phantom loaded with inserts of various human tissue substitutes was imaged using 125 kVp (KVCT) and 320 kVp (OVCT) x rays. Stoichiometric calibration was performed for both KVCT and OVCT imaging using the Schneider method. The metal inserts--titanium rods and aluminum rods--were used to study the impact of metal artifacts on the electron-density measurements both inside and outside the metal inserts. It was found that the relationships between Hounsfield units and relative electron densities (to water) were more predictable for OVCT than KVCT. Unlike KVCT, the stoichiometric calibration for OVCT was insensitive to the use of tissue substitutes for direct electron density calibration. OVCT was found to significantly reduce metal streak artifacts. Errors in electron-density measurements within uniform tissue substitutes were reduced from 42% (maximum) and 18% (root-mean-square) in KVCT to 12% and 2% in OVCT, respectively. Improvements were also observed inside the metal implants. For the detectors optimized for KVCT, the imaging dose is almost doubled for OVCT for the image quality comparable to KVCT. OVCT may be a good option for high-precision radiotherapy treatment planning, especially for patients with metal implants and especially for charged particle therapy, such as proton therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atomic-Scale Structure and Non-Stoichiometry of Meteoritic Hibonite: A Transmission Electron Microscope Study

Hibonite (CaAl_12O_19) is a common refractory mineral in Ca-Al-rich inclusions (CAIs) in primitive meteorites. Transmission electron microscope (TEM) studies have identified enigmatic planar defects in different occurrences of hibonite in the Allende meteorite that give rise to strong streaking along c* in electron diffraction patterns. Atomic resolution high-angle annular dark-field (HAADF) imaging and energy-dispersive X-ray (EDX) analyses were used to determine the nature and origin of these planar features. HAADF images of hibonite grains reveal lamellar intergrowths of common 1.6 nm spacing, and less commonly 2.0 and 2.5 nm spacings, interspersed in stoichiometric hibonite showing 1.1 nm (002) spacing. Stoichiometric hibonite consists of alternating Ca-containing (“R”) and spinel-structured (“S”) blocks stacked in a sequence RS. In contrast, the 1.6 nm layers result from a doubled S block such that the stacking sequence is RSS, while in the widest defect observed, the stacking sequence is RSSSS. These intergrowths are epitaxial and have coherent, low-strain boundaries with the host hibonite Meteoritic hibonite shows common Ti and Mg substitution for Al in its structure. Atomic-resolution EDX maps of hibonite grains in the Allende CAI confirm the preferred site occupancy of Mg on tetragonal M3 sites in S blocks and of Ti on trigonal bipyramidal M2 and octahedral M4 sites in R blocks. Mg is highly concentrated, but Ti is absent in the planar defects where wider S blocks show Al-rich compositions compared to stoichiometric MgAl_2O_4 spinel. Therefore, Mg likely played the major role in the formation and metastability of planar defects in hibonite. Electron energy loss spectroscopy data from the Ti L_2,3 edge show the presence of mixed Ti oxidation states with ~ 15–20% of Ti as Ti^(3+) in hibonite, suggesting a direct substitution of Ti^(3+) ↔ Al^(3+) in hibonite. The remaining ~ 80–85% of Ti is present as Ti^(4+) and corresponding EDX analyses are consistent with the well-known coupled substitution 2Al^(3+) ↔ Ti^(4+) + Mg^(2+) being the major mechanism for Ti and Mg substitution in hibonite. The formation of planar defects in hibonite occurred during high-temperature nebular condensation or melting/crystallization processes. The occurrence of non-stoichiometric hibonite in the Allende CAI deviates from the mineral formation sequence predicted from equilibrium condensation models. Overall, our atomic resolution TEM observations signify non-equilibrium, kinetic-controlled crystal growth during the high-temperature formation of refractory solids in the early solar nebula.

hibonite↗

Picosecond-resolved X-ray absorption spectroscopy at low signal contrast using a hard X-ray streak camera

A picosecond-resolving hard-X-ray streak camera has been in operation for several years at Sector 7 of the Advanced Photon Source (APS). Several upgrades have been implemented over the past few years to optimize integration into the beamline, reduce the timing jitter, and improve the signal-to-noise ratio. These include the development of X-ray optics for focusing the X-rays into the sample and the entrance slit of the streak camera, and measures to minimize the amount of laser light needed to generate the deflection-voltage ramp. For the latter, the photoconductive switch generating the deflection ramp was replaced with microwave power electronics. With these, the streak camera operates routinely at 88 MHz repetition rate, thus making it compatible with all of the APS fill patterns including use of all the X-rays in the 324-bunch mode. Sample data are shown to demonstrate the performance.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Laser acceleration and deflection of 963 keV electrons with a silicon dielectric structure

Radio frequency particle accelerators are ubiquitous in ultrasmall and ultrafast science, but their size and cost have prompted exploration of compact and scalable alternatives such as the dielectric laser accelerator. We present the first demonstration, to the best of our knowledge, of high gradient laser acceleration and deflection of electrons with a silicon structure. Driven by a 5 nJ, 130 fs mode-locked Ti:sapphire laser at 907 nm wavelength, our devices achieve accelerating gradients in excess of 200 MeV/m and suboptical cycle streaking of 96.30 keV electrons. Lastly, these results pave the way for high gradient silicon dielectric laser accelerators using commercial lasers and subfemtosecond electron beam experiments.

43 PARTICLE ACCELERATORS↗

Reliable and Repeatable Characterization of Optical Streak Cameras

Optical streak cameras are used as primary diagnostics for a wide range of physics and laser performance verification experiments at the National Ignition Facility (NIF). To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electronic components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases the characterization data is used to “correct” data images, to remove some of the nonlinearities. In order to obtain these camera characterizations, a specific data set is collected where the response to specific known inputs is recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, temporal resolution, etc., from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of single-shot attosecond pulses with angular streaking photoelectron spectra

Most of the traditional attosecond pulse retrieval algorithms are based on a so-called attosecond streak camera technique, in which the momentum of the electron is shifted by an amount depending on the relative time delay between the attosecond pulse and the streaking infrared pulse. Thus, temporal information of the attosecond pulse is encoded in the amount of momentum shift in the streaked photoelectron momentum spectrogram S(p,τ), where p is the momentum of the electron along the polarization direction and τ is the time delay. An iterative algorithm is then employed to reconstruct the attosecond pulse from the streaking spectrogram. This method, however, cannot be applied to attosecond pulses generated from free-electron x-ray lasers where each single shot is different and stochastic in time. However, using a circularly polarized infrared laser as the streaking field, a two (or three)-dimensional angular streaking electron spectrum can be used to retrieve attosecond pulses for each shot, as well as the time delay with respect to the circularly polarized IR field. Here we show that a retrieval algorithm previously developed for the traditional streaking spectrogram can be modified to efficiently characterize single-shot attosecond pulses. The methods have been applied to retrieve 188 single shots from recent experiments. We analyze the statistical behavior of these 188 pulses in terms of pulse duration, bandwidth, pulse peak energy, and time delay with respect to the IR field. Furthermore, the retrieval algorithm is efficient and can be easily used to characterize a large number of shots in future experiments for attosecond pulses at free-electron x-ray laser facilities.

74 ATOMIC AND MOLECULAR PHYSICS↗

Performance of a hardened x-ray streak camera at Lawrence Livermore National Laboratory’s National Ignition Facility

Electron tubes continue to provide the highest speeds possible for recording dynamics of hot high-energy density plasmas. Standard streak camera drive electronics and CCD readout are not compatible with the radiation environment associated with high DT fusion yield inertial confinement fusion experiments >10 13 14 MeV DT neutrons or >10 9 n cm -2 ns -1 . Here, we describe a hardened x-ray streak camera developed for the National Ignition Facility and present preliminary results from the first experiment on which it has participated, recording the time-resolved bremsstrahlung spectrum from the core of an inertial confinement fusion implosion at more than 40× the operational neutron yield limit of the previous National Ignition Facility x-ray streak cameras.

47 OTHER INSTRUMENTATION↗

Streamers at the Subnanosecond Breakdown of Argon and Nitrogen in Nonuniform Electric Field at Both Polarities

An ICCD camera was used to study plasma glow at the stage of the streamer (ionization wave) formation in the tip–plane gap with a length of 3 mm filled with argon or nitrogen at a pressure of 12.5–400 kPa. Positive and negative nanosecond voltage pulses were applied across the gap. Images of streamer were obtained at different time at its propagation along the gap. A streak-camera equipped with a spectrometer was used to measure time evolution of the radiation intensity of nitrogen molecules at a wavelength of 337.1 nm in several regions along the gap at the negative polarity. Average streamer velocity (1.8 cm/ns) was estimated from experimental data at atmospheric pressure of nitrogen. Amplitude–time characteristics of voltage, discharge current and the current of runaway electron beam behind the aluminum-foil anode with a thickness of 10 μm were measured. Reasons for a diffuse discharge under the given experimental conditions were discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultra fast x-ray streak camera for ten inch manipulator based platforms

Ultra fast x-ray streak cameras are a staple for time resolved x-ray measurements. There is a need for a ten inch manipulator (TIM) based streak camera that can be fielded in a newer large scale laser facility. The Lawrence Livermore National Laboratory ultra fast streak camera's drive electronics have been upgraded and redesigned to fit inside a TIM tube. The camera also has a new user interface that allows for remote control and data acquisition. The system has been outfitted with a new sensor package that gives the user more operational awareness and control.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra Fast X-ray Streak Camera for TIM Based Platforms

Ultra fast x-ray streak cameras are a staple for time resolved x-ray measurements. There is a need for a ten inch manipulator (TIM) based streak camera that can be fielded in a newer large scale laser facility. The LLNL ultra fast streak camera's drive electronics have been upgraded and redesigned to fit inside a TIM tube. The camera also has a new user interface that allows for remote control and data acquisition. The system has been outfitted with a new sensor package that gives the user more operational awareness and control.

47 OTHER INSTRUMENTATION↗

Megahertz-compatible angular streaking with few-femtosecond resolution at x-ray free-electron lasers

Highly brilliant, coherent, femtosecond x-ray pulses delivered by free-electron lasers (FELs) constitute one of the pillars of modern ultrafast science. Next generation FEL facilities provide up to megahertz repetition rates and pulse durations down to the attosecond regime utilizing self-amplification of spontaneous emission. However, the stochastic nature of this generation mechanism demands single-shot pulse characterization to perform meaningful experiments. Here we demonstrate a fast yet robust online analysis technique capable of megahertz-rate mapping of the temporal intensity structure and arrival time of x-ray FEL pulses with few-femtosecond resolution. We performed angular streaking measurements of both neon photo- and Auger electrons and show their applicability for a direct time-domain feedback system during ongoing experiments. Here, the fidelity of the real-time pulse characterization algorithm is corroborated by resolving isolated x-ray pulses and double pulse trains with few-femtosecond substructure, thus paving the way for x-ray-pump–x-ray-probe FEL science at repetition rates compatible with the demands of LCLS-II and European XFEL.

74 ATOMIC AND MOLECULAR PHYSICS↗

Temporal profile measurements of relativistic electron bunch based on wakefield generation

A complete characterization of the time-resolved longitudinal beam phase space is important to optimize the final performances of an accelerator, and in particular this is crucial for Free Electron Laser (FEL) facilities. In this study we propose a novel method to characterize the profile of a relativistic electron bunch by passively streaking the beam using its self-interaction with the transverse wakefield excited by the bunch itself passing off-axis through a dielectric-lined or a corrugated waveguide. Results of a proof-of-principle experiment at the SwissFEL Injector Test Facility are discussed.

43 PARTICLE ACCELERATORS↗

Conjugate echoes of artificially injected electron beams detected optically by means of new image processing

Artificial auroral streaks were detected following two upward injections of energetic electrons (38 keV and 26 keV) from the Echo 4 rocket-borne electron accelerator. Newly developed image processing techniques are used to detect and describe the streaks. It is found that the potential of the payload remained below 1 kV during 45 mA injections at an altitude of 210 km. The echo streaks show little dispersion in time or space, suggesting that the portion of the beam returning to the northern hemisphere loss cone remained collimated and nearly monoenergetic. There was, however, a 70 percent loss in the return flux. The causes of this loss are discussed.

Hallinan, Thomas J.↗

Following the dynamics of matter with femtosecond precision using the X-ray streaking method

X-ray Free Electron Lasers (FELs) can produce extremely intense and very short pulses, down to below 10 femtoseconds (fs). Among the key applications are ultrafast time-resolved studies of dynamics of matter by observing responses to fast excitation pulses in a pump-probe manner. Detectors with sufficient time resolution for observing these processes are not available. Therefore, such experiments typically measure a sample's full dynamics by repeating multiple pump-probe cycles at different delay times. This conventional method assumes that the sample returns to an identical or very similar state after each cycle. Here we describe a novel approach that can provide a time trace of responses following a single excitation pulse, jitter-free, with fs timing precision. We demonstrate, in an X-ray diffraction experiment, how it can be applied to the investigation of ultrafast irreversible processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Faraday rotation study of plasma bubbles in GeV wakefield accelerators

We visualize plasma bubbles driven by 0.67 PW laser pulses in a plasma of density ne≈5×1017cm−3 by imaging Faraday rotation patterns imprinted on linearly polarized probe pulses of wavelength λpr=1.05 μm and duration τpr=2 or 1 ps that cross the bubble's path at right angles. When the bubble captures and accelerates tens to hundreds of pC of electron charges, we observe two parallel streaks of length cτpr straddling the drive pulse propagation axis, separated by ∼45 μm, in which probe polarization rotates by 0.3° to more than 5° in opposite directions. Accompanying simulations show that they result from Faraday rotation within portions of dense bubble side walls that are pervaded by the azimuthal magnetic field of accelerating electrons during the probe transit across the bubble. Analysis of the width of the streaks shows that quasi-monoenergetic high-energy electrons and trailing lower energy electrons inside the bubble contribute distinguishable portions of the observed signals, and relativistic flow of sheath electrons suppresses Faraday rotation from the rear of the bubble. The results demonstrate favorable scaling of Faraday rotation diagnostics to 40× lower plasma density than previously demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗