Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrospray ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Influence of counterion substitution on the properties of imidazolium-based ionic liquid clusters

Due to their unique physiochemical properties that may be tailored for specific purposes, ionic liquids (ILs) have been investigated for various applications, including chemical separations, catalysis, energy storage, and space propulsion. The different cations and anions comprising ILs may be selected to optimize a range of desired properties, such as thermal stability, ionic conductivity, and volatility, leading to the designation of certain ILs as designer “green” solvents. The effect of counterions on the properties of ILs is of both fundamental scientific interest and technological importance. Herein, we report a systematic experimental and theoretical investigation of the size, charge, stability toward dissociation, and geometric/electronic structure of 1-ethyl-3-methyl imidazolium (EMIM)-based IL clusters containing two different atomic counterions (i.e., bromide [Br − ] and iodide [I − ]). This work extends our studies of EMIM + cations with atomic chloride (Cl − ) and molecular tetrafluoroborate (BF 4 − ) anions reported previously by Baxter et al. [Chem. Mater. 34, 2612 (2022)] and Zhang et al . [J. Phys. Chem. Lett. 11, 6844 (2020)], respectively. Distributions of anionic IL clusters were generated in the gas phase using electrospray ionization and characterized by high mass resolution mass spectrometry, energy-resolved collision-induced dissociation, and negative ion photoelectron spectroscopy experiments. The experimental results reveal anion-dependent trends in the size distribution, relative abundance, ionic charge state, stability toward dissociation, and electron binding energies of the IL clusters. Complementary global optimization theory provides molecular-level insights into the bonding and electronic structure of a selected subset of clusters, including their low energy structures and electrostatic potential maps, and how these fundamental characteristics are influenced by anion substitution. Collectively, our findings demonstrate how the fundamental properties of ILs, which determine their suitability for many applications, may be tuned by substituting counterions. These observations are critical in the sub-nanometer cluster size regime where phenomena do not scale predictably to the bulk phase, and each atom counts toward determining behavior.

cluster↗

Non-Targeted Direct Infusion Soluble Organic Analysis on a Tarda Meteorite Extract

The differences in chemistry, mineralogy, and structure of chondrites demonstrate thevariations in time/space of their forming regions in the solar nebula. In contrast, the variationof the organic reserves in the solar nebula is unclear. Furthermore, their subsequent evolutionof organic matter on the parent body is still under debate. In a previous study on Tagish Lake(C2 ungrouped) we showed that the primordial soluble organic matter (SOM) could bedistinguished from the parent body's secondary alteration threw mass distribution. This studywill show the Tarda meteorite SOM primordial distribution, using the model from ourprevious study. We discuss its organic reservoirs and secondary alteration effects. We alsocompare the character of the SOM with previously analysed Orgueil (CI). Sample and method: Tarda (fall, 2020) was classified as a C2 ungroup carbonaceouschondrite. Its bulk three oxygen isotope composition is distinct from other chondrite groupsbut similar to CI-chondrite-like and Yamato-type-like [1] values. We analysed themethanol/toluene extract using the high-resolution Orbitrap mass spectrometer at the Institutede Planétologie et d’Astrophysique Grenoble (IPAG) by directly injecting and ionizing theSOM and the solvent using the Heated Electrospray Ionization (HESI) source. After thespectra acquisition, the in-house developed post-processing data analysis tools, Attributor [2],was used. Preliminary Result: The SOM mass distribution of Tarda was well-fitted by the modelinterpreted as the primordial SOM distribution in Tagish lake. This common distributionpattern implies the presence of a common organic reservoir or SOM formation mechanism.Orgueil’s mass spectrum showed a more complex mass-distribution and seemed to be affectedby secondary processes. In contrast to the mass-distribution, SOM’s elemental abundance wasdistinct. The Tarda extract was enriched in S-bearing organic compounds which was incontrast to the Tagish Lake extract consisting of mostly CHNO elements. The presentationwill also discuss the application of our technique to Ryugu or Bennu samples. [1] Meteoriticalbulletin database [2] Orthous-Daunay, F. R. et al. (2019) Geochemical Journal, 53(1), 21-32

J Isa↗

Exploring Approaches for Accelerated Mass Spectrometric Detection of Fluorochemicals from Aqueous Solutions Using Indirect, Adsorbent-Facilitated Desorption Ionization

There is a growing need for rapid, low-cost analytical tools to screen water supplies for persistent contaminants. Due to their ubiquitous presence in the environment and their detrimental effects on human health, there is a public interest in widespread testing for perfluoroalkyl substances (PFAS). However, the most common methods for PFAS analysis can be time-intensive, requiring a preconcentration step followed by liquid chromatography–mass spectrometry (LC–MS), and are cost-prohibitive for most members of the public. To address these challenges, this study explores a novel method for rapid analysis of aqueous analytes by concentrating analytes on solid adsorbents and detecting them using mass spectrometric analysis via desorption ionization directly from the adsorbent surface. We demonstrate this general approach of indirect solution analysis (ISA) with desorption electrospray ionization (ISA-DESI) and laser desorption ionization (ISA-LDI). Various adsorbent materials were screened, including commercial mesoporous carbons, alumina, and metal–organic frameworks (MOFs). Using ISA-DESI, we consistently detect concentrations as low as 5–100 parts per trillion (ppt) for perfluorooctanoic acid (PFOA) and 10–100 ppt for perfluoroundecanoic acid (PFUnDA). This approach enables rapid detection in under 5 min, making it suitable for applications requiring trace detection with fast response times. We further demonstrate the use of ISA-DESI on a range of environmentally relevant contaminants. Advantages of this indirect solution analysis approach include simplified sample preparation, accelerated analysis, and low cost with readily available materials, making it a promising tool to accelerate mass spectrometric PFAS detection for identifying contaminated sites, performing laboratory studies, and monitoring industrial waste streams.

Bays, Nathan Robert [Sandia National Laboratories ↗

Three Methods of Detection of Hydrazines

Three proposed methods for measuring trace quantities of hydrazines involve ionization and detection of hydrazine derivatives. These methods are intended to overcome the limitations of prior hydrazine- detection methods. Hydrazine (Hz), monomethylhydrazine (MMH), and unsymmetrical dimethylhydrazine (UDMH) are hypergolic fuels and are highly reactive, toxic, and corrosive. A capability to measure concentrations of hydrazines is desirable for detecting leaks and ensuring safety in aerospace settings and in some industrial settings in which these compounds are used. One of the properties (high reactivity) that make it desirable to detect trace amounts of hydrazines also makes it difficult to detect hydrazines and measure their concentrations accurately using prior methods: significant amounts are lost to thermal and catalytic decomposition prior to detection. Further complications arise from the sticky nature of hydrazines: Sample hydrazine molecules tend to become irreversibly adsorbed onto solid surfaces with which they come into contact during transport to detectors, giving rise to drift in detector responses. In each proposed method, the reactive, sticky nature of hydrazines would be turned to advantage by providing a suitably doped substrate surface with which the hydrazines would react. The resulting hydrazine derivatives would be sufficiently less sticky and sufficiently more stable so that fewer molecules would be lost to decomposition or adsorption during transport. Consequently, it would be possible to measure concentration with more sensitivity and less error than in prior techniques. The first proposed method calls for the use of a recently developed technique known as desorption electrospray ionization (DESI), in which a pneumatically assisted micro -electrospray at ambient pressure is directed at a surface of interest. In this case, the surface of interest would be that of a substrate described above.

Griffin, Timothy↗

Efficient and Selective Chemical Transformations in Highly Charged and Confined Nanodroplets

The acceleration of chemical reaction rates and the increased product selectivity in microdroplets compared to that in bulk solutions has become a topic of increasing interest that has been extensively characterized by electrospray ionization mass spectrometry (ESI-MS). However, the sources of this acceleration and the detailed relationships between droplet properties and resulting reaction rate acceleration are still under debate. Moreover, droplet properties are governed by multiple interrelated experimental parameters, i.e., electrospray voltage, solution flow rate, etc., which makes it difficult and time-consuming to explore this diverse parameter space using traditional manual experimental or computational approaches. In this work, we developed an automated experimental platform integrating reactions in controlled charged microdroplet environments with ESI-MS characterization and sequential hybrid Bayesian modeling, as well as an optimal experimental design framework, to achieve multidimensional parameter optimization for higher reaction turnover rates, based on a model reaction of tetraethylenepentamine (TEPA) with carbon dioxide. With the current platform, we have achieved automated scans with a range of electrospray voltages and solution flow rates, and determined and optimized parameter settings to achieve increased reaction turnovers. We have also linked this platform to the underlying properties of droplets via a hybrid model incorporating physics, high-level theoretical calculations, and machine learning (ML) approaches. The autonomous platform is broadly applicable to a range of chemical reactions relevant to DOE’s mission in chemical separations, catalysis, and materials synthesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revealing Hidden Quinones Through Diagnostic MS² Fragmentation of Peptide–Quinone Adducts

Quinones are redox-active components of natural organic matter that mediate electron transfer and influence biogeochemical processes, but many quinones in pyrogenic organic matter (PyOM) remain unresolved because they ionize poorly by mass spectrometry. Here, we present a peptide-tagging approach to improve detection of cysteine-reactive electrophiles in PyOM, with quinones expected to be a dominant subset based on reaction chemistry and selectivity experiments. A cysteine-containing peptide was used to form Michael-addition adducts, enhancing electrospray ionization and enabling untargeted screening by high-performance liquid chromatography-high-resolution tandem mass spectrometry. The method was benchmarked with five quinone standards and applied to extracts from charred plant material as a discovery-level screen for cysteine-reactive targets. We identified 98 quinone-candidate adducts (mean neutral mass ~603 Da), of which more than 70% were not detectable in native MS1 data. Among formula-assigned features, hidden quinone candidates had median (O+N)/C of 0.391 and normalized oxidation state of carbon of -0.281, consistent with relatively low polarity and low oxidation state. These results reveal a previously inaccessible pool of hidden redox-active compounds in PyOM and provide a framework for prioritizing quinone-like electrophiles for confirmation and incorporation into models of fire-driven biogeochemical cycling.

LC-MS/MS↗

Investigation of the Solution Chemistry of Hybrid Organic–Inorganic Indium Halides for New Material Discovery

Recently, metal halide perovskites (MHPs) have emerged as a new class of materials for optical and electronic applications such as solar cells and ionizing radiation detectors. Although the solution-processability of MHPs is among their greatest advantages, the solution chemistries of most metal halide systems and their relationship with the observed structural and chemical diversity are poorly understood. In this work, we study the solution chemistry of a model indium halide system, methylammonium (MA)–In–Br, using a combination of the UV–vis spectroscopy, electrospray ionization mass spectrometry (ESI-MS) measurements, small-angle X-ray scattering (SAXS), and density functional theory (DFT) calculations. Our results show that indium could form either octahedral [InBr 6 3– ] or tetrahedral [InBr 4 – ] anions in solution or a combination of both, depending on the loading ratios of MABr and InBr 3 reactants. Understanding the solution chemistry of this system and recognizing the optical fingerprints of these polyanions allow for targeted crystallization of two novel compounds: MAInBr 4 featuring tetrahedral [InBr 4 – ] anions and MA 2 InBr 5 containing both octahedral [InBr 6 3– ] and tetrahedral [InBr 4 – ] anions. Further increase of the MABr content leads to the formation of previously reported MA 4 InBr 7 , containing only octahedral [InBr 6 3– ] anions separated by Br – anions. Furthermore, our results suggest that understanding the solution chemistry of multinary metal halide systems could be a valuable tool for discovering functional materials for practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Matrix-Assisted Ionization of Molecular Uranium Species

Matrix-assisted ionization (MAI) demonstrates high sensitivity for a variety of organic compounds; however, few studies have reported the application of MAI for the detection and characterization of inorganic analytes. Trace-level uranium analysis is important in the realms of nuclear forensics, nuclear safeguards, and environmental monitoring. Traditional mass spectrometry methods employed in these fields require combinations of extensive laboratory chemistry sample preparation and destructive ionization methods. There has been recent interest in exploring ambient mass spectrometry methods that enable timely sample analysis and higher sensitivity than what is attainable by field-portable radiation detectors. Rapid characterization of uranium at nanogram levels is demonstrated in this study using MAI techniques. Mass spectra were collected on an atmospheric pressure mass spectrometer for solutions of uranyl nitrate, uranyl chloride, uranyl acetate, and uranyl oxalate utilizing 3-nibrobenzonitrile as the ionization matrix. The uranyl complexes investigated were detectable, and the chemical speciation was preserved. Sample analysis was accomplished in a matter of seconds, and limits of detection of 5 ng of uranyl nitrate, 10 ng of uranyl oxalate, 100 ng of uranyl chloride, and 200 ng of uranyl acetate were achieved. The observed gas-phase speciation was similar to negative-ion electrospray ionization of uranyl compounds with notable differences. Six matrix-derived ions were detected in all negative-ion mass spectra, and some of these ions formed adducts with the uranyl analyte. Subsequent analysis of the matrix suggests that these molecules are not matrix contaminants and are instead created during the ionization process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid Droplet Sampling Interface for Low-Volume, High-Throughput Mass Spectrometry Analysis

Here, we present a rapid droplet sampling interface (RDSI) electrospray ionization mass spectrometry (ESI-MS) system as a high-throughput, low-volume, noncontact, and minimal-carryover approach for characterization of liquids. Liquid characterization was achieved by combining droplet ejection with an open-face microflow capillary with a 2.5 μL/min continuous flow of carrier solvent. Through this implementation, single 0.3 nL droplets containing the analyte effectively mix with 4–8 nL of carrier solvent and create a combined electrospray plume. The carrier solvent continuously cleaned the system, eliminating carryover. A sampling rate of 5 Hz was achieved for droplets containing 1 μM propranolol or 5 μM leu-enkephalin with each droplet fully baseline-resolved (138 ± 32 ms baseline-to-baseline). Using a SCIEX API4000 mass spectrometer, a lower limit of quantification (LLOQ) of propranolol was 15 nM, corresponding to 1.16 fg of propranolol in the droplet, and was linear across 3 orders of magnitude. Further, quantitation could be achieved by adding an isotopically labeled internal standard, as done in conventional ESI. Signal transients were faster than the acquisition speed of the mass spectrometer, resulting in artificially high reproducibility of 15–30% RSD droplet-to-droplet. Analyte–solvent mixing ratios could be controlled by adjusting droplet positioning along the open-face capillary with an optimal position about 0.4 mm from the tip end. The range of analyte coverage was exemplified by measures of peptides and drugs in methanol, water, and buffer solutions. In a comparison to the Open Port Sampling Interface (OPSI) implemented on the same system, the RDSI had 78× greater sensitivity, 6× greater throughput and used significantly less carrier solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selective Detection of Diglycolamide Diastereomers By Metal-Ligand Cluster Formation

Introduction (120 words): Differentiation of isomers using mass spectrometry is a challenge, as these species tend to produce ions of identical mass-to-charge ratio. Therefore, separation with mass spectrometry must rely on chemical differences between isomeric species. Separation of stereoisomers is especially challenging, as these species often have very similar chemistry. However, recent investigations of the solvent extraction behavior of diastereomers of diglycolamide molecules have shown that different stereoisomers can have significantly different lanthanide extraction efficiencies. These studies showed that the R,S stereoisomer of 2,2'-oxybis(N,N-dioctylpropanamide efficiently extracts lanthanides, while the S,S stereoisomer does not. Thus, gas-phase metal complexation may provide a pathway for differentiating these species using mass spectrometry. Methods (120 words): Europium, samarium, and holmium clusters with the R,S, and the S,S diastereomers of 2,2'-oxybis(N,N-didecylpropanamide (trivially tetradecyl diglycolamide, or mTDDGA) were generated in gas-phase using the electrospray ionization source of a Bruker (Billerica, MA, USA) micrOTOF-Q II quadrupole time-of-flight mass spectrometer. Solutions of aqueous lanthanide nitrate and diglycolamide ligands in 2-propanol were added to 50%:50% by volume acetonitrile:2-propanol to generate the spray solutions. Ligand concentration was maintained at approximately 6 µM, while lanthanide concentration was maintained at either 6 µM or 30 µM . High resolution, high mass accuracy spectra were recorded using the time-of-flight. Mass accuracy was ensured using external calibration with Agilent (Santa Clara, CA, USA) ESI-L Low Concentration tuning mix. Preliminary data (300 words): Electrospray of solutions containing only R,S-mTDDGA or S,S-m-TDDGA yield abundant peaks at m/z= 721.7, corresponding to [mTDDGA+H]+1, m/z = 743.7, corresponding to [mTDDGA+Na]+1, and m/z = 1464.4, corresponding to the sodium-bound dimer, [Na(mTDDGA)2]+1. Spray of solutions containing 6 µM europium (Eu) with 3 µM R,S-mTDDGA produced an abundant cluster ion with an isotopic envelope centered at m/z=772.0, corresponding to [Eu(R,S-mTDDGA)3]3+. Europium-containing cluster ions with isotopic envelopes apexing at m/z = 1012.3 and 1189.0 correspond to the [Eu(R,S-mTDDGA)4]3+ and [Eu(R,S-mTDDGA)5]3+ cluster ions, respectively. Protonated and sodiated R,S-mTDDGA are present as well, along with the sodium-bound dimer. In contrast, spray of solutions containing 6 µM europium (Eu) with 3 µM S,S-mTDDGA diastereomer yielded only protonated and sodiated ligand ions; no Eu- S,S-mTDDGA ions were present. This mirrors the solution-phase behavior, where the S,S diestereomer extracts lanthanides with significantly less efficiency than the R,S diestereomer. Experiments with holmium and samarium yielded the same results. Increasing the lanthanide concentration to 30 µM resulted in limited formation of lanthanide-S,S-mTDDGA clusters. However, the abundance of the [Ln(S,S-mTDDGA)3]3+ clusters remained low compared to the abundance of the protonated and sodiated ligand. Additionally, the abundance of the [Ln(R,S-mTDDGA)3]3+ cluster ion was significantly higher than that of the protonated and sodiated ligand in experiments with spray solutions containing 30 µM lanthanide with R,S-mTDDA, supporting the hypothesis that R,S-mTDDGA has a higher intrinsic affinity for the lanthanides than S,S-mTDDGA. Thus, the intrinsic complexation with lanthanides appears to offer a route to differentiate diglycolamide diestereomers in the gas-phase. Novelty (20): Stereoisomers can be differentiated in the gas phase by exploitation of differences in metal complexation chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational Methods for Modeling Electrospray Microdroplet Chemistry for Improved Quantitative Mass Spectrometry

This project aimed at enhancing the quantitative analysis capabilities of electrospray ionization mass spectrometry (ESI-MS) by developing advanced computational methods. The primary focus was to integrate continuum and molecular dynamics simulations to study the behavior of microdroplets in the ESI process, from formation to evaporation. Through this research, we sought to bridge significant length and time scales to provide a comprehensive understanding of how analyte concentrations evolve from bulk solutions into gas-phase ions. This understanding is crucial for addressing challenges such as ionization efficiency, solvent effects, and ion suppression, which currently limit the accuracy of quantitative ESI-MS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

HPLC/ESI-quadrupole ion trap mass spectrometry for characterization and direct quantification of amphoteric and nonionic surfactants in aqueous samples

An amphoteric (cocamidopropylbetaine, CAPB) and a nonionic (alcohol polyethoxylate, AE) surfactant were characterized by electrospray ionization quadrupole ion trap mass spectrometry (ESI-MS) as to their homologue distribution and ionization/fragmentation chemistry. Quantitative methods involving reversed-phase gradient HPLC and (+)ESI-MSn were developed to directly determine these surfactants in hydroponic plant growth medium that received simulated graywater. The predominant homologues, 12 C alkyl CAPB and 9 EO AE, were monitored to represent the total amount of the respective surfactants. The methods demonstrated dynamic linear ranges of 0.5-250 ng (r2 > 0.996) for CAPB and 8-560 ng (r2 > 0.998) for AE homologue mixture, corresponding to minimum quantification limits of 25 ppb CAPB and 0.4 ppm AE with 20-microL injections. This translated into an even lower limit for individual components due to the polydispersive nature of the surfactants. The procedure was successfully employed for the assessment of CAPB and AE biodegradation in a hydroponic plant growth system used as a graywater bioreactor.

NASA Discipline Life Support Systems↗

Soluble Organic Matter (SOM) analysis of the Hayabusa2 samples: The first results

The Hayabusa2 spacecraft successfully collected the surface and possible sub-surface materials of the asteroid 162173 Ryugu. Ryugu is a C-type asteroid characterized by a low-albedo surface probably consisting of hydrous minerals and carbonaceous materials. [1] The direct optical and spectral analysis of the returned samples indicates that Ryugu material is dominated by hydrous carbonaceous chondrite-like matter (similar to CI chondrites) [2]. Since carbonaceous chondrites have generally yielded various types of organic matter, the collected Ryugu grains are expected to contain diverse types of organic compounds including bio-related molecules. The occurrence of organic compounds in the Ryugu surface will provide clues to the evolution of prebiotic molecules and their preservations associated with aqueous alteration of the primitive asteroid. The initial analysis of soluble organic matter (SOM) of the Hayabusa2-returned samples has been performed by an international team consisting of 32 members. Because the sample amount available for comprehensive SOM analyses is limited, and because the SOM is expected to be present as a complex mixture of various types of organic compounds with very small concentrations of each compound, high-sensitivity and high-resolution analytical techniques have been developed using carbonaceous meteorites [e.g. 3]. Two aggregate samples of the Ryugu grains (A106 and C107) were allocated for the solvent extractions and bulk carbon (C), hydrogen (H), nitrogen (N), sulfur (S) and oxygen (O) measurements. The A106 sample was collected during the 1st sampling in February 2019 and the C107 sample was collected during the 2nd sampling in July 2019 after the Small Carry Impactor (SCI) operation. They consist mainly of particles smaller than 1 mm in diameter, and each sample mass was 38-39 mg. They were firstly investigated spectroscopically in the near infrared wavelength range by the Stone Team prior to the solvent extractions. Other small grains (A0080 and C0057) were also allocated for this study to investigate the spatial distribution of organic compounds on the sample surface. The extraction and analytical measurements implemented by the SOM Team are summarized in Figure 1. Each powder sample was extracted sequentially with non-polar to polar solvents, i.e., hexane, dichloromethane (DCM), methanol (MeOH) and H2O, for non-targeted analysis to reveal the compound composition. Each solvent extract was analyzed by solution state nuclear magnetic resonance (NMR) spectroscopy [4], Fourier transform- ion cyclotron resonance/mass spectrometry (FT-ICR/MS) with ESI and APPI ionization [5] and by high-resolution mass spectroscopy using Orbitrap MS coupled with nano-liquid chromatography (nanoLC/Orbitrap MS) [6], and using two dimensional gas chromatography/mass spectrometry (GC×GC/MS). The extracted residues were passed to the Chemistry Team for further inorganic element analysis. The other powder sample was subjected to the hot water extraction for amino acid analyses including chiral isomer separation, which was performed by three-dimensional (3D) high-performance liquid chromatography (HPLC) with high-sensitivity fluorescence detection (FD) [7] and by HPLC/FD coupled with quadrupole-time of flight/mass spectrometry (QToF/MS) [8]. After the hot water extraction, the residue was split into two halves. One half was further extracted with hydrochloric acid (HCl) to analyze for amino acids in bound-form. The other half was sequentially extracted with DCM/MeOH (1/1) to analyze semi-polar compounds such as polycyclic aromatic hydrocarbons (PAHs) by GC/MS, followed by further extraction with formic acid to analyze polar heterocyclic compounds, and subsequent extraction with HCl to detect bound-form polar compounds. The extracted residues were passed to the IOM Team for the analysis of insoluble organic matter (IOM). Compound-specific stable isotope analyses will be performed using GC/combustion/isotope ratio mass spectrometry (GC/C/IRMS) if the compound concentration is high enough to enable such an isotopic measurement. All extraction procedures were performed on an ISO 6 (Class 100) clean bench inside an ISO 5 (Class 1000) clean room. Baked serpentine powder was also analyzed as a procedural blank. In situ organic compound analysis with the molecular imaging was performed using desorption electrospray ionization (DESI) equipped with Orbitrap MS [9, 10], followed by spatial imaging of organic compounds using ToF/secondary ion mass spectrometry (ToF/SIMS) [11]. The bulk chemical and isotopic compositions of CNS and HO were determined using nano-elemental analysis/isotope ratio mass spectrometry (nanoEA/IRMS) [12] and EA/pyrolysis/IRMS, respectively. We have identified a variety of indigenous organic compounds in the extracts of both A106 and C107 samples. The Ryugu grains host organic molecules under the high-vacuum and cosmic-ray irradiation environment of the asteroid surface. The analysis of extracted molecules is in progress, and the first results will be presented at the symposium.

Hiroshi Naraoka↗

Are Phosphatidic Acids Ubiquitous in Mammalian Tissues or Overemphasized in Mass Spectrometry Imaging Applications?

Abstract Mass spectrometry imaging (MSI) is an invaluable tool for the spatial visualization of molecules in vivo. However, the question of whether observed annotations are endogenous or artificial (i. e., from in‐source fragmentation) is critical and has been largely unexplored in multimodal MSI. In matrix‐assisted laser desorption/ionization (MALDI)‐MSI datasets from researchers worldwide, PAs were found to represent up to 18 % of annotations in rat brain. Rat brain was additionally imaged here using nanospray desorption electrospray ionization (nano‐DESI), a softer ionization strategy. No PAs observed with MALDI were present in the nano‐DESI dataset. Further investigation strongly indicated lipid fragmentation to PAs for MALDI‐MSI, but not with nano‐DESI‐MSI. We finally extend this observation to the MALDI‐MSI analyses of human tissues, showing that PA annotations comprised up to 16 % of annotations. Therefore, this study shows that MSI annotations should be carefully interrogated, as in‐source fragmentation or modification of lipids may contribute substantially to false annotations and incorrect biological interpretations.

Vandergrift, Gregory W.↗

Pertechnetate/perrhenate–capped Zr/Hf–Dihydroxide Dimers: Elucidating Zr–TcO 4 Co–Mobility in the Nuclear Fuel Cycle

Spent nuclear fuel contains heavy element fission products that must be separated for effective reprocessing for a safe and sustainable nuclear fuel cycle. 93 Zr and 99 Tc are high-yield fission products that co-transport in liquid-liquid extraction processes. Here we seek atomic-level information of this co-extraction process, as well as fundamental knowledge about Zr IV (and Hf IV ) aqueous speciation in the presence of topology-directing ligands such as pertechnetate (TcO 4 – ) and non-radioactive surrogate perrhenate (ReO 4 – ). In this context, we show that the flat tetrameric oxyhydroxyl-cluster [M IV 4 (OH) 8 (H 2 O) 16 ] 8+ (and related polymers) is dissociated by perrhenate/pertechnetate to yield isostructural dimers, M 2 (OH) 2 (XO 4 – ) 6 (H 2 O) 6 • 3H 2 O (M=Zr/Hf IV ; X=Re/Tc VII ), elucidated by single-crystal X-ray diffraction. We used these model compounds to understand the pervasive 93 Zr- 99 Tc coextraction with further speciation studies in water, nitric acid, and tetrabutylphosphate (TBP) -kerosene; where the latter two media are relevant to nuclear fuel reprocessing. SAXS (small angle X-ray scattering), compositional evaluation, and where experimentally feasible, ESI-MS (electrospray ionization mass spectrometry) showed that perrhenate/pertechnetate influence Zr/Hf IV -speciation in water. Here, in Zr-XO 4 solvent extraction studies to simulate fuel reprocessing, we provide evidence that TcO 4 – enhances extraction of Zr IV , and compositional analysis of the extracted metal-complexes (Zr-ReO 4 study) is consistent with the crystallized Zr IV 2 (OH) 2 (Re VII O 4 – ) 6 (H 2 O) 6 •dimer.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Probing Noncovalent Interaction Strengths of Host-Guest Complexes Using Negative Ion Photoelectron Spectroscopy

Noncovalent interactions (NCIs) are crucial for the formation and stability of host-guest complexes, which have wide-ranging implications across various fields, including biology, chemistry, materials science, pharmaceuticals, and environmental science. However, since NCIs are relatively weak and sensitive to bulk perturbation, direct and accurate measurement of their absolute strength has always been a significant challenge. This concept article aims to demonstrate the gas-phase electrospray ionization (ESI)-negative ion photoelectron spectroscopy (NIPES) as a direct and precise technique to measure the absolute interaction strength, probe nature of NCIs, and reveal the electronic structural information for host-guest complexes. Here, our recent studies in investigating various host-guest complexes that involve various types of NCIs such as anion–π, (di)hydrogen bonding, charge-separated ionic interactions, are overviewed. Finally, a summary and outlook are provided for this field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An international laboratory comparison of dissolved organic matter composition by high resolution mass spectrometry: Are we getting the same answer?

Since the first detailed compositional analysis of dissolved organic matter (DOM) in 1995, high resolution mass spectrometry (HRMS) has become a vital tool for DOM characterization. While the upward trend in HRMS for molecular level analysis of DOM continues, so do the challenges of data comparison and interpretation between laboratories operating instruments of differing performance and user operating conditions. It is therefore essential that the community establishes whether data and trends can be compared robustly between research groups. To this end, 4 identically prepared DOM samples were each studied by 16 laboratories, representing 17 commercially-purchased instruments located across 8 countries, using positive- and negative-mode electrospray ionization (ESI) HRMS analysis. Despite the widely reported sensitivity of ESI experiments to sample matrix, preparation, ion source operation and instrument tuning parameters, the instruments used in this study showed relatively low variability between results for the same samples, particularly H/C and AI metrics. The variation in O/C and m/z metrics was relatively higher, although z-score graphs and %BCD demonstrated that the relative difference in general chemical composition between samples was the same for each instrument included in the study. As such, these metrics can be used for fingerprinting of DOM samples and as a benchmark for quality control in participating laboratories, with future strides in environmental science building upon these efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid Chromatography Mass Spectrometry study of eutectic bis(2,2-dinitropropyl) acetal/formal

This study is the first attempt to document methodology development undergone using liquid chromatography tandem quadrupole time of flight mass spectrometry (LC-QTOF) to investigate degradation products of eutectic bis(2,2-dinitropropyl) acetal/formal nitroplasticizer (called NP here). Method properties investigated are: desolvation temperature (°C) and spray voltage (V) of the electrospray ionization source, and the development of an acetone system rinse to prevent any residual contamination between sample injections. Details are given on why it is essential to investigate method optimization with changes shown in MS/MS analysis in addition to MS results. Trends in MS/MS analytic results reveal important relationships between baseline and aged materials. In addition to verification of previously proposed fragments, insights offered by this newly developed methodology will also identify new degradation products and shed light on the complexity of NP degradation chemistry.

36 MATERIALS SCIENCE↗