Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrospray ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Investigation of the Solution Chemistry of Hybrid Organic–Inorganic Indium Halides for New Material Discovery

Recently, metal halide perovskites (MHPs) have emerged as a new class of materials for optical and electronic applications such as solar cells and ionizing radiation detectors. Although the solution-processability of MHPs is among their greatest advantages, the solution chemistries of most metal halide systems and their relationship with the observed structural and chemical diversity are poorly understood. In this work, we study the solution chemistry of a model indium halide system, methylammonium (MA)–In–Br, using a combination of the UV–vis spectroscopy, electrospray ionization mass spectrometry (ESI-MS) measurements, small-angle X-ray scattering (SAXS), and density functional theory (DFT) calculations. Our results show that indium could form either octahedral [InBr 6 3– ] or tetrahedral [InBr 4 – ] anions in solution or a combination of both, depending on the loading ratios of MABr and InBr 3 reactants. Understanding the solution chemistry of this system and recognizing the optical fingerprints of these polyanions allow for targeted crystallization of two novel compounds: MAInBr 4 featuring tetrahedral [InBr 4 – ] anions and MA 2 InBr 5 containing both octahedral [InBr 6 3– ] and tetrahedral [InBr 4 – ] anions. Further increase of the MABr content leads to the formation of previously reported MA 4 InBr 7 , containing only octahedral [InBr 6 3– ] anions separated by Br – anions. Furthermore, our results suggest that understanding the solution chemistry of multinary metal halide systems could be a valuable tool for discovering functional materials for practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Matrix-Assisted Ionization of Molecular Uranium Species

Matrix-assisted ionization (MAI) demonstrates high sensitivity for a variety of organic compounds; however, few studies have reported the application of MAI for the detection and characterization of inorganic analytes. Trace-level uranium analysis is important in the realms of nuclear forensics, nuclear safeguards, and environmental monitoring. Traditional mass spectrometry methods employed in these fields require combinations of extensive laboratory chemistry sample preparation and destructive ionization methods. There has been recent interest in exploring ambient mass spectrometry methods that enable timely sample analysis and higher sensitivity than what is attainable by field-portable radiation detectors. Rapid characterization of uranium at nanogram levels is demonstrated in this study using MAI techniques. Mass spectra were collected on an atmospheric pressure mass spectrometer for solutions of uranyl nitrate, uranyl chloride, uranyl acetate, and uranyl oxalate utilizing 3-nibrobenzonitrile as the ionization matrix. The uranyl complexes investigated were detectable, and the chemical speciation was preserved. Sample analysis was accomplished in a matter of seconds, and limits of detection of 5 ng of uranyl nitrate, 10 ng of uranyl oxalate, 100 ng of uranyl chloride, and 200 ng of uranyl acetate were achieved. The observed gas-phase speciation was similar to negative-ion electrospray ionization of uranyl compounds with notable differences. Six matrix-derived ions were detected in all negative-ion mass spectra, and some of these ions formed adducts with the uranyl analyte. Subsequent analysis of the matrix suggests that these molecules are not matrix contaminants and are instead created during the ionization process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid Droplet Sampling Interface for Low-Volume, High-Throughput Mass Spectrometry Analysis

Here, we present a rapid droplet sampling interface (RDSI) electrospray ionization mass spectrometry (ESI-MS) system as a high-throughput, low-volume, noncontact, and minimal-carryover approach for characterization of liquids. Liquid characterization was achieved by combining droplet ejection with an open-face microflow capillary with a 2.5 μL/min continuous flow of carrier solvent. Through this implementation, single 0.3 nL droplets containing the analyte effectively mix with 4–8 nL of carrier solvent and create a combined electrospray plume. The carrier solvent continuously cleaned the system, eliminating carryover. A sampling rate of 5 Hz was achieved for droplets containing 1 μM propranolol or 5 μM leu-enkephalin with each droplet fully baseline-resolved (138 ± 32 ms baseline-to-baseline). Using a SCIEX API4000 mass spectrometer, a lower limit of quantification (LLOQ) of propranolol was 15 nM, corresponding to 1.16 fg of propranolol in the droplet, and was linear across 3 orders of magnitude. Further, quantitation could be achieved by adding an isotopically labeled internal standard, as done in conventional ESI. Signal transients were faster than the acquisition speed of the mass spectrometer, resulting in artificially high reproducibility of 15–30% RSD droplet-to-droplet. Analyte–solvent mixing ratios could be controlled by adjusting droplet positioning along the open-face capillary with an optimal position about 0.4 mm from the tip end. The range of analyte coverage was exemplified by measures of peptides and drugs in methanol, water, and buffer solutions. In a comparison to the Open Port Sampling Interface (OPSI) implemented on the same system, the RDSI had 78× greater sensitivity, 6× greater throughput and used significantly less carrier solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selective Detection of Diglycolamide Diastereomers By Metal-Ligand Cluster Formation

Introduction (120 words): Differentiation of isomers using mass spectrometry is a challenge, as these species tend to produce ions of identical mass-to-charge ratio. Therefore, separation with mass spectrometry must rely on chemical differences between isomeric species. Separation of stereoisomers is especially challenging, as these species often have very similar chemistry. However, recent investigations of the solvent extraction behavior of diastereomers of diglycolamide molecules have shown that different stereoisomers can have significantly different lanthanide extraction efficiencies. These studies showed that the R,S stereoisomer of 2,2'-oxybis(N,N-dioctylpropanamide efficiently extracts lanthanides, while the S,S stereoisomer does not. Thus, gas-phase metal complexation may provide a pathway for differentiating these species using mass spectrometry. Methods (120 words): Europium, samarium, and holmium clusters with the R,S, and the S,S diastereomers of 2,2'-oxybis(N,N-didecylpropanamide (trivially tetradecyl diglycolamide, or mTDDGA) were generated in gas-phase using the electrospray ionization source of a Bruker (Billerica, MA, USA) micrOTOF-Q II quadrupole time-of-flight mass spectrometer. Solutions of aqueous lanthanide nitrate and diglycolamide ligands in 2-propanol were added to 50%:50% by volume acetonitrile:2-propanol to generate the spray solutions. Ligand concentration was maintained at approximately 6 µM, while lanthanide concentration was maintained at either 6 µM or 30 µM . High resolution, high mass accuracy spectra were recorded using the time-of-flight. Mass accuracy was ensured using external calibration with Agilent (Santa Clara, CA, USA) ESI-L Low Concentration tuning mix. Preliminary data (300 words): Electrospray of solutions containing only R,S-mTDDGA or S,S-m-TDDGA yield abundant peaks at m/z= 721.7, corresponding to [mTDDGA+H]+1, m/z = 743.7, corresponding to [mTDDGA+Na]+1, and m/z = 1464.4, corresponding to the sodium-bound dimer, [Na(mTDDGA)2]+1. Spray of solutions containing 6 µM europium (Eu) with 3 µM R,S-mTDDGA produced an abundant cluster ion with an isotopic envelope centered at m/z=772.0, corresponding to [Eu(R,S-mTDDGA)3]3+. Europium-containing cluster ions with isotopic envelopes apexing at m/z = 1012.3 and 1189.0 correspond to the [Eu(R,S-mTDDGA)4]3+ and [Eu(R,S-mTDDGA)5]3+ cluster ions, respectively. Protonated and sodiated R,S-mTDDGA are present as well, along with the sodium-bound dimer. In contrast, spray of solutions containing 6 µM europium (Eu) with 3 µM S,S-mTDDGA diastereomer yielded only protonated and sodiated ligand ions; no Eu- S,S-mTDDGA ions were present. This mirrors the solution-phase behavior, where the S,S diestereomer extracts lanthanides with significantly less efficiency than the R,S diestereomer. Experiments with holmium and samarium yielded the same results. Increasing the lanthanide concentration to 30 µM resulted in limited formation of lanthanide-S,S-mTDDGA clusters. However, the abundance of the [Ln(S,S-mTDDGA)3]3+ clusters remained low compared to the abundance of the protonated and sodiated ligand. Additionally, the abundance of the [Ln(R,S-mTDDGA)3]3+ cluster ion was significantly higher than that of the protonated and sodiated ligand in experiments with spray solutions containing 30 µM lanthanide with R,S-mTDDA, supporting the hypothesis that R,S-mTDDGA has a higher intrinsic affinity for the lanthanides than S,S-mTDDGA. Thus, the intrinsic complexation with lanthanides appears to offer a route to differentiate diglycolamide diestereomers in the gas-phase. Novelty (20): Stereoisomers can be differentiated in the gas phase by exploitation of differences in metal complexation chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational Methods for Modeling Electrospray Microdroplet Chemistry for Improved Quantitative Mass Spectrometry

This project aimed at enhancing the quantitative analysis capabilities of electrospray ionization mass spectrometry (ESI-MS) by developing advanced computational methods. The primary focus was to integrate continuum and molecular dynamics simulations to study the behavior of microdroplets in the ESI process, from formation to evaporation. Through this research, we sought to bridge significant length and time scales to provide a comprehensive understanding of how analyte concentrations evolve from bulk solutions into gas-phase ions. This understanding is crucial for addressing challenges such as ionization efficiency, solvent effects, and ion suppression, which currently limit the accuracy of quantitative ESI-MS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Are Phosphatidic Acids Ubiquitous in Mammalian Tissues or Overemphasized in Mass Spectrometry Imaging Applications?

Abstract Mass spectrometry imaging (MSI) is an invaluable tool for the spatial visualization of molecules in vivo. However, the question of whether observed annotations are endogenous or artificial (i. e., from in‐source fragmentation) is critical and has been largely unexplored in multimodal MSI. In matrix‐assisted laser desorption/ionization (MALDI)‐MSI datasets from researchers worldwide, PAs were found to represent up to 18 % of annotations in rat brain. Rat brain was additionally imaged here using nanospray desorption electrospray ionization (nano‐DESI), a softer ionization strategy. No PAs observed with MALDI were present in the nano‐DESI dataset. Further investigation strongly indicated lipid fragmentation to PAs for MALDI‐MSI, but not with nano‐DESI‐MSI. We finally extend this observation to the MALDI‐MSI analyses of human tissues, showing that PA annotations comprised up to 16 % of annotations. Therefore, this study shows that MSI annotations should be carefully interrogated, as in‐source fragmentation or modification of lipids may contribute substantially to false annotations and incorrect biological interpretations.

Vandergrift, Gregory W.↗

Pertechnetate/perrhenate–capped Zr/Hf–Dihydroxide Dimers: Elucidating Zr–TcO 4 Co–Mobility in the Nuclear Fuel Cycle

Spent nuclear fuel contains heavy element fission products that must be separated for effective reprocessing for a safe and sustainable nuclear fuel cycle. 93 Zr and 99 Tc are high-yield fission products that co-transport in liquid-liquid extraction processes. Here we seek atomic-level information of this co-extraction process, as well as fundamental knowledge about Zr IV (and Hf IV ) aqueous speciation in the presence of topology-directing ligands such as pertechnetate (TcO 4 – ) and non-radioactive surrogate perrhenate (ReO 4 – ). In this context, we show that the flat tetrameric oxyhydroxyl-cluster [M IV 4 (OH) 8 (H 2 O) 16 ] 8+ (and related polymers) is dissociated by perrhenate/pertechnetate to yield isostructural dimers, M 2 (OH) 2 (XO 4 – ) 6 (H 2 O) 6 • 3H 2 O (M=Zr/Hf IV ; X=Re/Tc VII ), elucidated by single-crystal X-ray diffraction. We used these model compounds to understand the pervasive 93 Zr- 99 Tc coextraction with further speciation studies in water, nitric acid, and tetrabutylphosphate (TBP) -kerosene; where the latter two media are relevant to nuclear fuel reprocessing. SAXS (small angle X-ray scattering), compositional evaluation, and where experimentally feasible, ESI-MS (electrospray ionization mass spectrometry) showed that perrhenate/pertechnetate influence Zr/Hf IV -speciation in water. Here, in Zr-XO 4 solvent extraction studies to simulate fuel reprocessing, we provide evidence that TcO 4 – enhances extraction of Zr IV , and compositional analysis of the extracted metal-complexes (Zr-ReO 4 study) is consistent with the crystallized Zr IV 2 (OH) 2 (Re VII O 4 – ) 6 (H 2 O) 6 •dimer.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Probing Noncovalent Interaction Strengths of Host-Guest Complexes Using Negative Ion Photoelectron Spectroscopy

Noncovalent interactions (NCIs) are crucial for the formation and stability of host-guest complexes, which have wide-ranging implications across various fields, including biology, chemistry, materials science, pharmaceuticals, and environmental science. However, since NCIs are relatively weak and sensitive to bulk perturbation, direct and accurate measurement of their absolute strength has always been a significant challenge. This concept article aims to demonstrate the gas-phase electrospray ionization (ESI)-negative ion photoelectron spectroscopy (NIPES) as a direct and precise technique to measure the absolute interaction strength, probe nature of NCIs, and reveal the electronic structural information for host-guest complexes. Here, our recent studies in investigating various host-guest complexes that involve various types of NCIs such as anion–π, (di)hydrogen bonding, charge-separated ionic interactions, are overviewed. Finally, a summary and outlook are provided for this field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An international laboratory comparison of dissolved organic matter composition by high resolution mass spectrometry: Are we getting the same answer?

Since the first detailed compositional analysis of dissolved organic matter (DOM) in 1995, high resolution mass spectrometry (HRMS) has become a vital tool for DOM characterization. While the upward trend in HRMS for molecular level analysis of DOM continues, so do the challenges of data comparison and interpretation between laboratories operating instruments of differing performance and user operating conditions. It is therefore essential that the community establishes whether data and trends can be compared robustly between research groups. To this end, 4 identically prepared DOM samples were each studied by 16 laboratories, representing 17 commercially-purchased instruments located across 8 countries, using positive- and negative-mode electrospray ionization (ESI) HRMS analysis. Despite the widely reported sensitivity of ESI experiments to sample matrix, preparation, ion source operation and instrument tuning parameters, the instruments used in this study showed relatively low variability between results for the same samples, particularly H/C and AI metrics. The variation in O/C and m/z metrics was relatively higher, although z-score graphs and %BCD demonstrated that the relative difference in general chemical composition between samples was the same for each instrument included in the study. As such, these metrics can be used for fingerprinting of DOM samples and as a benchmark for quality control in participating laboratories, with future strides in environmental science building upon these efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid Chromatography Mass Spectrometry study of eutectic bis(2,2-dinitropropyl) acetal/formal

This study is the first attempt to document methodology development undergone using liquid chromatography tandem quadrupole time of flight mass spectrometry (LC-QTOF) to investigate degradation products of eutectic bis(2,2-dinitropropyl) acetal/formal nitroplasticizer (called NP here). Method properties investigated are: desolvation temperature (°C) and spray voltage (V) of the electrospray ionization source, and the development of an acetone system rinse to prevent any residual contamination between sample injections. Details are given on why it is essential to investigate method optimization with changes shown in MS/MS analysis in addition to MS results. Trends in MS/MS analytic results reveal important relationships between baseline and aged materials. In addition to verification of previously proposed fragments, insights offered by this newly developed methodology will also identify new degradation products and shed light on the complexity of NP degradation chemistry.

36 MATERIALS SCIENCE↗

Absolute quantitation of propranolol from 200-μm regions of mouse brain and liver thin tissues using laser ablation-dropletProbe-mass spectrometry

Rationale: The ability to quantify drugs and metabolites in tissue with sub-mm resolution is a challenging but much needed capability in pharmaceutical research. To fill this void, a novel surface sampling approach combining laser ablation with the commercial dropletProbe automated liquid surface sampling system (LA-dropletProbe) was developed and presented here.Methods: Parylene C-coated 200 × 200 μm tissue regions of mouse brain and kidney thin tissue sections were analyzed for propranolol by laser ablation of tissue directly into a preformed liquid junction. Propranolol was detected by high performance liquid chromatography with positive ion mode electrospray ionization tandem mass spectrometry. Quantitation was achieved via application of a stable isotope-labeled internal standard and an external calibration curve.Results: Absolute concentration of propranolol determined from 200 × 200 µm tissue regions were compared to propranolol concentrations obtained from 2.3-mm-diameter tissue punches of adjacent, non-coated sections using standard bulk tissue extraction protocols followed by regular HPLC-MS/MS analysis. Average concentration of propranolol in both organs determined by the two employed methods agreed within ±12%. Furthermore, the relative abundance of phase II hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous results.Conclusions: This work illustrates that depositing a thin parylene C layer onto thin tissue prior to analysis, which seals the surface and prevents direct liquid extraction of the drug from the tissue, coupled to the novel LA-dropletProbe surface sampling system is a viable approach for sub-mm resolution quantitative drug distribution analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Integrated laser ablation-dropletProbe-mass spectrometry for absolute drug quantitation, metabolite detection, and distribution in tissue

Rationale: Spatially resolved and accurate quantitation of drug-related compounds in tissue is a much-needed capability in drug discovery research. In this work, application of an integrated laser ablation-dropletProbe-mass spectrometry surface sampling system (LADP-MS) is reported, which achieved absolute quantitation of propranolol measured from <500 × 500 μm thin tissue samples. Methods: Mouse liver and kidney thin tissue sections were coated with parylene C and analyzed for propranolol by a laser ablation/liquid extraction workflow. Non-coated adjacent sections were microdissected for validation and processed using standard bulk tissue extraction protocols. High-performance liquid chromatography with positive ion mode electrospray ionization tandem mass spectrometry was applied to detect the drug and its metabolites. Results: Absolute propranolol concentration in ~500 × 500 μm tissue regions measured by the two methods agreed within ±8% and had a relative standard deviation within ±17%. Quantitation down to ~400 × 400 μm tissue regions was shown, and this resolution was also used for automated mapping of propranolol and phase II hydroxypropranolol glucuronide metabolites in kidney tissue. Conclusions: This study exemplifies the capabilities of integrated laser ablation-dropletProbe-mass spectrometry (LADP-MS) for high resolution absolute drug quantitation analysis of thin tissue sections. This capability will be valuable for applications needing to quantitatively understand the spatial distribution of small molecules in tissue.

47 OTHER INSTRUMENTATION↗

High-throughput mass spectrometry analysis using immediate drop-on-demand technology coupled with an open port sampling interface

Rationale: The sampling throughput of immediate drop-on-demand technology (I.DOT) coupled with an open port sampling interface (OPSI) is limited by software communication. To enable much-needed high-throughput mass spectrometry (MS) analysis capabilities, a novel software was developed that allows for flexible sample selection from a 96-well plate and for maximized analysis throughput using I.DOT/OPSI-MS coupling. Methods: Wells of a 96-well I.DOT plate were filled with propranolol solution and were used to test maximum sampling throughput strategies to minimize analysis time. Demonstration of chemical reaction monitoring was done using acid-catalyzed ring closure of 2,3-diaminonaphthalene (DAN) with nitrite to form 2,3-naphthotriazole (NAT). Analytes were detected in positive electrospray ionization mode using selected reaction monitoring. Results: A maximum throughput of 1.54 s/sample (7.41 min/96-well plate with three technical replicates) was achieved, and it was limited by the peak width of the MS signal resulting in an occasional slight overlap between the peaks. Further, relative standard deviation was 10 ± 1% with all tested sampling strategies. Chemical reaction monitoring of DAN to NAT using nitrite was successfully accomplished with 2 s/sample throughout showing almost complete transformation in 10 min with no signal overlap. Conclusions: This work illustrates the development of a noncontact, automated I.DOT/OPSI-MS system with improved throughput achieved through an optimized software interface. Its achievable analysis time and precision make it a viable approach for drug discovery and in situ reaction monitoring studies.

47 OTHER INSTRUMENTATION↗

Single-Cell Metabolomics with Rapid Determination of Chemical Formulas from Isotopic Fine Structures

Metabolomic measurements can provide functional readouts of cellular states and phenotypes. Here, we present a protocol for single-cell metabolomics that permits direct untargeted detection of a broad number of metabolites under ambient conditions, without the need for sample processing, and with high confidence in the discovery and identification of the molecular formulas for detected metabolites. This protocol describes combining fiber-based laser ablation electrospray ionization (f-LAESI) with a 21 Tesla Fourier transform ion cyclotron resonance mass spectrometer (21T-FTICR-MS) to obtain high confidence molecular formula information about detected metabolites. The f-LAESI source utilizes mid-infrared laser ablation through a sharp optical fiber tip, affording direct ambient analysis of cells without the need for sample processing. Using the 21T-FTICR-MS as a mass analyzer enabled measurement of the isotopic fine structure (IFS) for numerous metabolites simultaneously from single cells, and the IFSs were in turn computationally processed to rapidly determine the corresponding elemental compositions. This metabolomics technique complements other single cell omics measurement methods, helping to resolve complex molecular interactions that take place within cells unattainable from single cell transcriptomic and proteomics methods.

mass spectrometry, FTICR, FTMS, ultrahigh mass res↗

Dehydration of gas-phase benzyl amine alcohols studied at atmospheric pressure

Gas-phase ion chemistry is a useful approach for the investigation of physical organic chemistry and the study of reactivity, structure, and thermochemical properties of ionic and neutral organic substrates. Herein, one-step dehydration of gas-phase benzyl amine alcohols to give benzazetidines was discovered without the use of catalysts. Mechanistic investigations of the gas-phase dehydration reactions were explored to study the possible influence of charged microdroplet acceleration during electrospray ionization (ESI) and collisions occurring during ion transfer through the atmospheric pressure interface (API) of the mass spectrometer. The product ion distribution was observed to be less sensitive to droplet effects (spray distance and voltage), and temperature of transfer capillary in the API. However, the product ion distribution exhibit high sensitivity to different S-lens radio frequency (RF) voltage of the API, providing evidence that the dehydration reaction is driven by collisions during ion transfer in the API. With this insight, we developed atmospheric pressure thermal dissociation platform that allowed thermal-induced collisions outside of the mass spectrometer when the benzyl amine alcohols are carried through a heated coiled tube. Up to 98% dissociation efficiency was achieved with the coiled tube heated to a temperature of 200 °C, yielding only the desired benzazetidine product. Finally, by performing the atmospheric pressure thermal dissociation experiment outside of the mass spectrometer, we believe it will be straightforward to collect the dehydration product.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗

Toward sustainable production of N-containing products via nonthermal plasma-enhanced conversion of natural gas resources

Nonthermal plasmas can directly activate and cleave the strong chemical bonds in molecular nitrogen and methane to facilitate the transformation of these inherently stable molecules through the application of electrical energy. Here, we report a low temperature, atmospheric pressure, nonthermal plasma for the “one-pot” synthesis of olefins, alkynes, higher molecular weight hydrocarbons, ammonia, and nitrogen-containing liquids from a representative shale gas feed enriched with nitrogen. Furthermore, we reproducibly observe a wide range of valuable and synthetically challenging gas-phase and liquid-phase products containing C-N, C-C, and N-H bonding by controlling the N 2 concentration in the inlet feed stream. In nitrogen-lean regimes, hydrocarbon products dominate (e.g., ethylene, acetylene, etc.), while nitrogen-rich regimes promote incorporation of nitrogen into the products, leading to the formation of ammonia and liquid products containing a variety of functionalities (e.g., nitriles, amines, heterocycles). High resolution electrospray ionization mass spectrometry was used to measure molecular weights and identify the chemical formulas of the liquid products. Van Krevelen diagrams were created and showed many products with compositions around H/C = 2 and N/C = 0.5, indicating the potential importance of intermediate species with these ratios for liquid formation (e.g., CH 3 CN + H).

03 NATURAL GAS↗