Search NASA⌕ Search

SEARCH · Search NASA

Results for “elution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Fractionation of Filamentous Algae from Mixed Biofilms

Filamentous algae, which grow in long, hair-like filaments within biofilms, play a crucial role in wastewater treatment due to their ability to produce significant biomass and their resistance to predation compared to traditional microalgal treatments. These algae can effectively uptake and utilize pollutants, particularly excessive nitrogen (ammonia, nitrate, nitrite) and phosphorus (phosphate), making filamentous algae valuable for wastewater treatment, as well as bioethanol and biodiesel production due to high lipid productions. However, each algal species possesses different capacities, necessitating a thorough genetic identification and understanding of each community. A major challenge in accurately assessing these communities is the lack of coverage in large sequencing databases which can lead to misrepresentation of the true composition and abundance of organisms and overall sequencing bias. To address this, I evaluated chemical and physical techniques for separating filamentous algae from mixed biofilms to achieve clean genetic sequencing results. I employed pH washing (0.001M HCl, 0.001M HCl, DiH2O, 0.0001M HCl, 0.001M HCl) for chemical treatment, followed by physical separation through centrifugation (5000rpm, 6500rpm) or filtration (2mm, 250um, 75um). The most successful method was deionized water washing, which yielded clear differences across stacked filters; the 2mm filtrate showed high levels of filamentous algae, with microalgae eluting in the 75um filtrate or remaining within agglutinations of algae larger filters. Base washing eluted the highest concentrations of microalgae, with larger filter sizes retaining more filamentous algae, indicating the breakdown of extracellular polymeric substances (EPS). Our downstream plans include sending the high-throughput next-generation sequencing to confirm the purity and ratios of filamentous and non-filamentous algae, as well as bacteria present, thereby validating the success of our treatments. Potential applications include creating community-based fractions for analysis, refining current sequencing data with clearer isolations, and generating designer biofilms to enhance our understanding of community interactions.

59 BASIC BIOLOGICAL SCIENCES↗

16s Amplicon Analysis of Soil Data for Interactive effects of depth and differential irrigation on soil microbiome composition and functioning

Genomic DNA was isolated from soil and rhizosphere samples using the Zymo Quick-DNA fecal/soil microbe miniprep kit (catalog no. D6010) according to the manufacturer’s instructions (Zymo Research; Irvine, CA) with the modification of eluting in 100 uL elution buffer. Sample concentrations were quantified using the Qubit dsDNA HS assay kit (Thermo Fisher). For rhizosphere samples only, DNA was subsequently purified using Zymo’s ZR-96 DNA Clean & Concentrator kit (catalog no. D4024) to account for low DNA concentrations of these samples. . In each replicate block, there were five drip irrigation treatments (T1 = 100% normal irrigation, T2 = 56.25%, T3 = 37.5%, T4 = 18.75% and T5=no irrigation. On July 20, the strength of the drought treatments was increased: T1 remained at 100%, whereas T2 changed from 75% to 56.25%, T2 changed from 50% to 37.5%, and T4 changed from 25% to 18.75%. Sequencing was performed as described previously (Naylor, Fansler, et al. 2020). Sequences were amplified on the MiSeq platform (Illumina, San Diego, CA) using 16S primers (515F and 806R) specific to the V4 region. Raw sequence data was processed with the pipeline Hundo for amplicon quality control and annotation. Downstream statistical analyses on 16S datasets were performed using the program R and the packages ‘phyloseq’ and ‘vegan’.

Soil microbiome, metatranscriptomics↗

Methods for separating isotopes from a sample of fission products

Systems and methods for efficient, effective, and safe separation and isolation of multiple isotopes (e.g., Mo, Zr, Ba, Sr, Te, and lanthanide isotopes) from fission products includes use of a plurality of chromatography columns, each containing a chromatographic resin formulated to target one or more particular isotopes. The system is operable in a “series” configuration to load the multiple columns by a single pass of the sample. Then, the system may be transitioned (e.g., using valves) to a “parallel” configuration in which multiple columns of the system may be operated simultaneously to elute targeted isotopes. Additional parallel operations of the columns, using different eluent compositions, may be used to elute different targeted isotopes. The system may be reconditioned in preparation for a subsequent sample.

Snow, Mathew S.↗

System and method for collecting and isolating radiosotopes

A method for obtaining 225 AC from 225 Ra having the steps of assembling a column having an inorganic stationary phase; priming the column to immobilize 226 Ra 225 Ra and natural decay products therefrom; immobilizing the 226 Ra, 225 Ra, 224 Ra, and natural decay products therefrom onto a stationary phase within the column; and eluting the column containing the 225 Ra with an aqueous sulfate solution to obtain a milking effluent that contains 225 AC. Also provided is a method for obtaining pure 225 AC from its isotope parents, the method comprising assembling a column having a stationary phase comprising an inorganic material; priming the column with the isotope parents to immobilize 225 Ac, and natural decay products of 225 AC; immobilizing the 225 Ac, and natural decay products therefrom onto the stationary phase within the column 226 Ra, 225 Ra, 224 Ra; and eluting the column containing the 225 AC to obtain an effluent that contains the isotope parents.

Brown, Michael A.↗

Systems for separating isotopes from a sample of fission products

Systems and methods for efficient, effective, and safe separation and isolation of multiple isotopes (e.g., Mo, Zr, Ba, Sr, Te, and lanthanide isotopes) from fission products includes use of a plurality of chromatography columns, each containing a chromatographic resin formulated to target one or more particular isotopes. The system is operable in a “series” configuration to load the multiple columns by a single pass of the sample. Then, the system may be transitioned (e.g., using valves) to a “parallel” configuration in which multiple columns of the system may be operated simultaneously to elute targeted isotopes. Additional parallel operations of the columns, using different eluent compositions, may be used to elute different targeted isotopes. The system may be reconditioned in preparation for a subsequent sample.

Snow, Mathew S.↗

Testing of Crystalline Silicotitanate to Support Tank-Side Cesium Removal System Operations - 20458

The direct feed of waste from the Hanford tank farms to the Low-Activity Waste Facility at the Hanford Waste Treatment and Immobilization Plant requires an intermediate treatment step that prepares the waste for vitrification. Washington River Protection Solutions (WRPS) selected a near-tank treatment system known as the Tank-Side Cesium Removal (TSCR) system to perform the required intermediate treatment functions. The approach in the TSCR system is to filter waste supernatant with a sintered metal dead-end filter and then use a series of ion exchange columns to remove cesium; this system has several similarities to the Tank Closure Cesium Removal system that has been deployed on the Savannah River Site. The ion exchange media proposed for use is crystalline silicotitanate (CST), which is a non-elutable media with a high affinity for cesium. Because the media is non-elutable, loaded columns will be blown down with compressed air, moved into interim storage, and replaced with new columns when cesium capacity is reached. The assumed extent and rate of drying that could be achieved in the TSCR column geometry lacked confirmation by experimental data. In addition, once the columns are loaded with cesium, they generate flammable gases (primarily hydrogen) via radiolysis acting on any resident liquids, i.e., moisture, remaining in the media bed. An assessment of available information on CST concluded that gas generation data that bounds expected operational conditions were needed to support the TSCR system safety basis and planned operations. Working with WRPS, Pacific Northwest National Laboratory (PNNL) designed and conducted testing with CST media to address the need for (a) representative in-column drying data, and (b) bounding flammable gas generation data. Drying testing was performed using a full-height column with a diameter of approximately 2 inches with injected air at temperatures of 18 deg. C and 30 deg. C. Gas generation testing was conducted in an engineered bunker that allowed simultaneous irradiation of up to eight samples at a time. These two experimental approaches used at PNNL for the CST testing are summarized and the major outcomes are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adaptable SEC‐SAXS data collection for higher quality structure analysis in solution

Abstract The two major challenges in synchrotron size‐exclusion chromatography coupled in‐line with small‐angle x‐ray scattering (SEC‐SAXS) experiments are the overlapping peaks in the elution profile and the fouling of radiation‐damaged materials on the walls of the sample cell. In recent years, many post‐experimental analyses techniques have been developed and applied to extract scattering profiles from these problematic SEC‐SAXS data. Here, we present three modes of data collection at the BioSAXS Beamline 4–2 of the Stanford Synchrotron Radiation Lightsource (SSRL BL4‐2). The first mode, the High‐Resolution mode, enables SEC‐SAXS data collection with excellent sample separation and virtually no additional peak broadening from the UHPLC UV detector to the x‐ray position by taking advantage of the low system dispersion of the UHPLC. The small bed volume of the analytical SEC column minimizes sample dilution in the column and facilitates data collection at higher sample concentrations with excellent sample economy equal to or even less than that of the conventional equilibrium SAXS method. Radiation damage problems during SEC‐SAXS data collection are evaded by additional cleaning of the sample cell after buffer data collection and avoidance of unnecessary exposures through the use of the x‐ray shutter control options, allowing sample data collection with a clean sample cell. Therefore, accurate background subtraction can be performed at a level equivalent to the conventional equilibrium SAXS method without requiring baseline correction, thereby leading to more reliable downstream structural analysis and quicker access to new science. The two other data collection modes, the High‐Throughput mode and the Co‐Flow mode, add agility to the planning and execution of experiments to efficiently achieve the user's scientific objectives at the SSRL BL4‐2.

Matsui, Tsutomu↗

Separation of zirconium and hafnium from early actinides and rare earth elements with eichrom’s pb resin in HCl

The separation of zirconium and hafnium isotopes from the early actinides and rare earth elements (REE) with Eichrom’s Pb resin has been studied. Batch studies were performed to characterize the behavior of actinium, thorium, zirconium, hafnium, lutetium, and yttrium on Pb resin from HCl solutions (0.001 M to 11 M). The early actinides and REE had no affinity for the resin at any concentration of HCl, but zirconium and hafnium showed a moderate uptake at high concentrations of HCl with a maximum extraction at 11 M HCl. Several column separations were tested, including with only tracer isotopes and with mass. Rapid, simple separations of zirconium from actinium, thorium, protactinium, and the REE with high yields and low elution volumes are presented with applications for tracer isotope production and fission product separations. Furthermore, the resin is less suitable for hafnium separations as hafnium tends to bleed off the resin even at high concentrations of HCl.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Column separation of tetravalent cerium fission products from trivalent rare earth radio-isotopes

Rapid and efficient isolation of individual rare earth element (REE) radioisotopes from complex mixtures is necessary to support the fields of nuclear forensics, medical isotope production and nuclear physics measurements. The separations must be robust and generate sufficiently high purity samples for subsequent radiological analysis. Current methodologies utilize a laborious two step Ce(IV)-iodate precipitation followed by Ce(IV)-nitrate di-(2-ethylhexyl)phosphoric acid/n-heptane extraction. This work reports an alternative method to isolate Ce fission product isotopes equilibrated with milligrams of cold carrier, from the remaining REE’s using a Ce(IV)/LN-resin (Eichrom Technologies) based separation. Optimization of Ce(IV) loading, REE(III) elution volume and subsequent Ce(III) stripping step utilized 166m Ho tracer. Mixed fission product experiments provided a further test of this LN-resin method, with analysis of purified 141/144 Ce, 147 Nd and 91 Y. Overall, while decontamination factors were lower for the LN-resin method, (vs. the combined precipitation/extraction) the simplicity of the technique and the satisfactory fission product analysis results point to the efficacy of this method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Applications of a dual-column technique in actinide separations

Selective separation of an individual actinide of interest from other actinides and accompanying lanthanides is a challenging task in radiochemistry and radioanalytical chemistry. This paper illustrates a dual column technique (i.e., stacked columns of two appropriate resins) to separate an individual actinide of interest, where the selection of two resins and a common effluent running through the stacked columns are key parameters in design of an appropriate dual column. This paper describes the dual column design and practice with two examples, one for a heavy actinide 249Bk and the other for a light actinide 230U. In the former case, stacked columns of anion exchange (AX) resin and LN resin replaced the traditional CX-AHIB method used at Oak Ridge National Laboratory for 60 years. In the latter case, an elution process with an AX column followed with a stacked column of AX resin and a DGA resin was applied, instead of traditional methods, e.g., PUREX or U-TEVA methods. Application results of the dual column method to the two example actinides are displayed, while the considerations in method design and the required conditions are discussed.

Du, Miting↗

Extraction of selenium and arsenic with TOA-impregnated XAD-2 resin from HCl

Here the uptake of 75 Se and 73 As on trioctylamine-impregnated resin from HCl solutions was studied with batch uptake, kinetics, and column studies. Selenium-75 extracts well (D w ~ 900) at high HCl concentrations (≥ 10 M) with and no extraction of 73 As at any HCl concentration. The uptake kinetics were slow with low extraction (D w < 100) for time periods ≤ 15 min and no clear equilibrium achieved even after 24 h. Column studies were performed to characterize the separation of 75 Se and 73 As; 75Se is retained from conc. HCl while arsenic is eluted with high yields and high radiopurity.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Behavior of selenium and arsenic in $\mathrm{HCl}$ and $\mathrm{HNO}$ 3 on $\mathrm{TRU, TEVA, DGA,}$ and $\mathrm{Pb}$ extraction chromatography resins

The uptake behavior of 73 As and 75 Se was studied in HCl and HNO 3 -H 2 O 2 solutions on commercial extraction chromatography resins (TEVA, TRU, DGA, and Pb resin). There was no uptake of 73 As or 75 Se from HNO 3 media. From HCl, there was 75 Se uptake at high concentrations on all the resins and no uptake of 73 As. Separations of 75 Se and 73 As on these resins have high yields and high radiopurity for 73 As, but limited recovery of 75 Se. TRU and TEVA resin may have potential for use in isotope generators as 75 Se can be retained for at least 26 days with repeated elutions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Cation exchange separation of radium and actinium using lactic acid DTPA buffer

The separation of actinium ( 228 Ac) from radium ( 223,228 Ra) on cation exchange resin with a diethylenetriaminpentaacetic acid-lactate buffer solution is demonstrated with series of columns. High yield, high radiopurity (~ 100%) separations of Ac from Ra are feasible with small columns in biologically compatible conditions and pHs. As Ac is eluted before Ra on these columns, further studies were performed to determine if this separation system could be applied to Ra/Ac isotope generators, but these were not successful. In conclusion, the separations presented in this work may be relevant for radiopharmaceutical purifications of 225 Ac which is typically obtained from its 225 Ra parent isotope.

and nuclear chemistry↗

Evaluation of engineered sorbents for the sorption of mercury from contaminated bank soils: a column study

Abstract As a global environmental pollutant, mercury (Hg) threatens our water resources and presents a substantial risk to human health. The rate and extent of immobilization of Hg 2+ (hereafter, Hg) on engineered sorbents (Thiol-SAMMS®, pine biochar, SediMite™, Organoclay™ PM-199, and quartz sand as a control) was evaluated using flow-through column experiments. The effectiveness of the sorbents was based on (1) the percentage of Hg removed in relation to the total amount of Hg passing the sorbent column, and (2) the rate of Hg uptake compared to the nonreactive tracer bromide (Br − ). All sorbents removed Hg to a certain extent, but none of the sorbents removed all the Hg introduced to the columns. Thiol-SAMMS showed the highest mean percentage of Hg removed (87% ± 2.9%), followed by Organoclay PM-199 (71% ± 0.4%), pine biochar (57% ± 22.3%), SediMite (61% ± 0.8%), and the control quartz sand (11% ± 5.6%). Thiol-SAMMS was the only sorbent to exhibit retardation of Hg in comparison to the conservative tracer Br − . For the remaining sorbents, Br − along with low concentrations of Hg were eluted within the first 3 pore volumes, indicating limited retardation of Hg. Overall, removal of Hg by sorbents was substantial, suggesting that sorbents might be suitable for deployment in contaminated environments. High concentrations of DOM leaching from the soil columns likely influenced the speciation of Hg and inhibited sorption to the sorbents. Incomplete removal of Hg by any sorbent suggests that additional optimization is needed to increase efficiency.

54 ENVIRONMENTAL SCIENCES↗

Palladium/Zeolite Low Temperature Passive NOx Adsorbers (PNA): Structure-Adsorption Property Relationships for Hydrothermally Aged PNA Materials

Zeolites with different framework structures (SSZ-13, ZSM-5, BEA) but similar Si/Al ratios and Pd loading (~1 wr%) were synthesized and evaluated as low temperature passive NOx adsorbers (PNA). These materials exhibit high NOx adsorption efficiency with atomically dispersed Pd the active adsorption site. Hydrothermal aging at 750 ºC for 16 hours in the presence of 10% water vapor in air resulted in the formation of PdO nanoparticles in all three samples as evidenced by high energy XRD. Hydrothermal aging of the small-pore Pd/SSZ-13 (Si/Al = 6), which contain ~100-90% atomically dispersed palladium ions, decreases its PNA performance only by ~10-20%. High-field solid state 27Al NMR studies on the fresh and aged samples substantiate dealumination and significant changes in the distribution of Al (and thus, Bronsted acid) sites after hydrothermal aging. FTIR measurements with NO probe molecule and titration of Bronsted acid sites with nitrosyl (NO+) ions further corroborate the 27Al NMR data. Because framework aluminum atoms are the anchoring sites for atomically dispersed Pd ions, their elution from the framework causes the loss of active atomically dispersed Pd species. Furthermore, with the aid of HAADF-STEM imaging and synchrotron XRD studies, we further confirm and visualize the fate of these Pd species – they agglomerate into PdO nanoparticles on the external surface of zeolite. Consequently, these changes lead to the decrease in PNA performance of these materials after hydrothermal aging. The thus formed agglomerates cannot be re-dispersed back to their ionic state due to the loss of framework Al T-sites and/or inherent stability of such large PdO particles. Our study clearly demonstrates that, unlike in previous studies that found increased PNA performance upon HTA , high temperatures hydrothermal aging of PNA materials that contain atomically dispersed Pd initially, results in a decrease in NOx storage efficiency due mostly to the formation of PdO agglomerates. However, we also highlight the high hydrothermal stability of predominantly atomically dispersed 1-3 wt% Pd/SSZ-13 (Si/Al = 6), whose performance decreases only marginally after prolonged hydrothermal aging at 750 ºC. Overall, this study shows that hydrothermally stable passive NOx materials can be prepared using small-pore SSZ-13 zeolite.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separation of radium and actinium using zirconia

Herein, zirconia was investigated as a radiation-resistant support for radium and actinium aqueous ion separations. Acetate and total metal ion concentrations were experimentally evaluated as factors that could affect retention using La and Ba surrogates. Pseudo-second order rate constants were derived and the uptake of La was determined to be endothermic. Elution profiles containing Ba, La, 228 Ra, 228 Ac, and 212 Pb are presented and discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of hydroxamate-based resins towards a more clinically viable 44 Ti/ 44 Sc radionuclide generator

For this research, several hydroxamate-based resins were synthesized and tested for use in 44 Ti/ 44 Sc generator systems in small scale experiments (740 kBq 44 Ti). The most promising resin was tested further in larger scale generator studies (37 MBq). This resin displayed impressive retention of 44 Ti over several elutions, and high quantities of 44 Sc were obtained in small volumes of dilute HCl eluents. Initial radiolabeling experiments were conducted and demonstrated the possibility of direct radiolabeling of the generator produced 44 Sc with DOTA.

07 ISOTOPE AND RADIATION SOURCES↗

Determination of transition metal ions in fossil fuel associated wastewaters using chelation ion chromatography

Here, this study outlines the development and subsequent validation of a method using chelation ion chromatography (CIC) pretreatment followed by traditional ion chromatography (IC) and post column UV/vis detection to measure transition metals in fossil fuel wastewaters, such as oil &amp; gas (O&G) brines and coal mine drainage (CMD) waters. Measurement of transition metals is often an important characterization step in the research of environmental and energy systems. IC represents one way to measure these metals with the advantages of being versatile, simple and relatively low cost compared to other analytical methods. However, high concentrations of alkali and alkaline earth metals present in fossil fuel wastewaters will decrease IC detectability of transition metals in these waters. In this study, a CIC method was developed for the analysis of transition metal ions (Fe 3+ , Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , Mn 2+ , and Fe 2+ ) in fossil fuel associated wastewaters such as Appalachian CMD and O&G wastewaters from the Permian and Bakken shale basins in the United States. CIC system incorporated an on-line chelator column (e.g., the MetPac CC-1) with high selectivity for transition metals over alkali and alkaline earth metals for salt matrix removal prior to transition metal separation and detection. Additional method developments also included acidifying all samples to 2% v/v HCl and using gradient elution rather than isocratic. The recoverability of transition metals in simple salt solutions commonly found in CMD and brine samples (e.g. NaCl, Na 2 SO 4 , CaCl 2 ) using CIC was evaluated and compared to that using traditional IC. Our results found that the CIC system significantly improved transition metal recoveries for samples in 10,000 mg/L CaCl 2 matrix, reaching 87%-108% recovery for all analytes, as opposed to 2-323% recovery in traditional IC. The limits of detection in this study achieved 10.09 – 161.2 μg/L, comparable to reported values in similar IC studies. The developed method was also verified with certified water samples, resulting in 89% - 111% recoveries in samples with higher analyte concentrations (i.e. >4x the LoDs). The developed method achieved 87% -112% recoveries for most analytes in CMD samples and 72%-138% recoveries for Bakken shale samples, relative to ICP-MS values. Overall, the current IC method can be a very good screening tool for fast and cheap analysis for transition metals at mg/L level, to facilitate selection of samples for more detailed ICP-MS analysis.

01 COAL, LIGNITE, AND PEAT↗