Search NASA⌕ Search

SEARCH · Search NASA

Results for “end effector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Vision-based end-effector position error compensation

This paper describes a computationally efficient algorithm that provides the ability to accurately place an arm end-effector on a target designated in an image using low speed feed back from a fixed stero camera.

error vector↗

Handheld Controller For Robotic End Effector

Controller provides both position and force feedback. Hand grip houses controller. End-effector force and position fed back to operator's hand through rotation of trigger and rocking of trigger guard.

Jau, Bruno M.↗

The design and development of an end effector for the shuttle remote manipulator system

The design requirements, the design, and qualification and development test problems encountered on the Remote Manipulator End Effector are described. The constraints and interfaces with the arm, the Orbiter, and the payload are identified. The design solution to meet the requirements is a unique device that provides a soft-docking feature termed capture and a hard-docking feature termed rigidization.

Daniell, R. G.↗

Autonomous dexterous end-effectors for space robotics

The development of a knowledge-based controller is summarized for the Belgrade/USC robot hand, a five-fingered end effector, designed for maximum autonomy. The biological principles of the hand and its architecture are presented. The conceptual and software aspects of the grasp selection system are discussed, including both the effects of the geometry of the target object and the task to be performed. Some current research issues are presented.

Bekey, George A.↗

End-effector microprocessor

The topics are presented in viewgraph form and include: automated structures assembly facility current control hierarchy; automated structures assembly facility purposed control hierarchy; end-effector software state transition diagram; block diagram for ideal install composite; and conclusions.

William R Doggett↗

Robotic end effector system with surface tracking and methods for use

A non-destructive inspection system is presented. The non-destructive inspection system comprises a robotic end effector having an extendable actuator and a flange-mounted roller containing an ultrasonic sensor, the flange-mounted roller connected to the extendable actuator by a pivot connection, the extendable actuator configured to extend the flange-mounted roller until the flange-mounted roller contacts an inspection surface.

Troy, James J.↗

Space Station racks weight and CG measurement using the rack insertion end-effector

The objective was to design a method to measure weight and center of gravity (C.G.) location for Space Station Modules by adding sensors to the existing Rack Insertion End Effector (RIEE). Accomplishments included alternative sensor placement schemes organized into categories. Vendors were queried for suitable sensor equipment recommendations. Inverse mathematical models for each category determine expected maximum sensor loads. Sensors are selected using these computations, yielding cost and accuracy data. Accuracy data for individual sensors are inserted into forward mathematical models to estimate the accuracy of an overall sensor scheme. Cost of the schemes can be estimated. Ease of implementation and operation are discussed.

Brewer, William V.↗

Rack Insertion End Effector (RIEE) automation

NASA is developing a mechanism to manipulate and insert Racks into the Space Station Logistic modules. The mechanism consists of the following: a base with three motorized degrees of freedom, a 3 section motorized boom that goes from 15 to 44 feet in length, and a Rack Insertion End Effector (RIEE) with 5 hand wheels for precise alignment. The robotics section was tasked with the automation of the RIEE unit. In this report, for the automation of the RIEE unit, application of the Perceptics Vision System was conceptually developed to determine the position and orientation of the RIEE relative to the logistic module, and a MathCad program is written to display the needed displacements for precise alignment and final insertion of the Rack. The uniqueness of this report is that the whole report is in fact a MathCad program including text, derivations, and executable equations with example inputs and outputs.

Malladi, Narasimha↗

Rack Insertion End Effector (RIEE) guidance

NASA-KSC has developed a mechanism to handle and insert Racks into the Space Station Logistic Modules. This mechanism consists of a Base with 3 motorized degrees of freedom, a 3 section motorized Boom that goes from 15 to 44 feet in length, and a Rack Insertion End Effector (RIEE) with 5 hand wheels for precise alignment. During the 1993 NASA-ASEE Summer Faculty Fellowship Program at KSC, I designed an Active Vision (Camera) Arrangement and developed an algorithm to determine (1) the displacements required by the Room for its initial positioning and (2) the rotations required at the five hand-wheels of the RIEE, for the insertion of the Rack, using the centroids fo the Camera Images of the Location Targets in the Logistic Module. Presently, during the summer of '94, I completed the preliminary design of an easily portable measuring instrument using encoders to obtain the 3-Dimensional Coordinates of Location Targets in the Logistics Module relative to the RIEE mechanism frame. The algorithm developed in '93 can use the output of this instrument also. Simplification of the '93 work and suggestions for the future work are discussed.

Malladi, Narasimha S.↗

Development of a Pre-Prototype Power Assisted Glove End Effector for Extravehicular Activity

The purpose of this program was to develop an EVA power tool which is capable of performing a variety of functions while at the same time increasing the EVA crewmember's effectiveness by reducing hand fatigue associated with gripping tools through a pressurized EMU glove. The Power Assisted Glove End Effector (PAGE) preprototype hardware met or exceeded all of its technical requirements and has incorporated acoustic feedback to allow the EVA crewmember to monitor motor loading and speed. If this tool is to be developed for flight use, several issues need to be addressed. These issues are listed.

Source record↗

Telepresence master glove controller for dexterous robotic end-effectors

This paper describes recent research in the Aerospace Human Factors Research Division at NASA's Ames Research Center to develop a glove-like, control and data-recording device (DataGlove) that records and transmits to a host computer in real time, and at appropriate resolution, a numeric data-record of a user's hand/finger shape and dynamics. System configuration and performance specifications are detailed, and current research is discussed investigating its applications in operator control of dexterous robotic end-effectors and for use as a human factors research tool in evaluation of operator hand function requirements and performance in other specialized task environments.

Fisher, Scott S.↗

End-effector-joint conjugates for robotic assembly of large truss structures in space: A second generation

Attachment of strut to node can be accomplished with a variety of mechanisms. All require extensive standoff elements (called scars) added to the nodes. These increase packaging volume for the nodes by as much as 300 percent. First generation designs also tend to be either heavy or expensive due to complex parts. Screws thread mechanisms are discussed simplest and most easily manufactured of alternatives. Torque and rotational motion must be transmitted across the strut to end-effector interface accomplishing the joining process and establishing a specific preload. Four drive mechanisms are considered: worm, helical, bevel, and differential gears.

Brewer, William V.↗

Manipulation based on sensor-directed control: An integrated end effector and touch sensing system

A hand/touch sensing system is described that, when mounted on a position-controlled manipulator, greatly expands the kinds of automated manipulation tasks that can be undertaken. Because of the variety of coordinate conversions, control equations, and completion criteria, control is necessarily dependent upon a small digital computer. The sensing system is designed both to be rugged and to sense the necessary touch and force information required to execute a wide range of manipulation tasks. The system consists of a six-axis wrist sensor, external touch sensors, and a pair of matrix jaw sensors. Details of the construction of the particular sensors, the integration of the end effector into the sensor system, and the control algorithms for using the sensor outputs to perform manipulation tasks automatically are discussed.

Hill, J. W.↗

Design and simulation of EVA tools and robot end effectors for servicing missions of the HST

The Hubble Space Telescope (HST) was launched into near-earth orbit by the Space Shuttle Discovery on April 24, 1990. The payload of two cameras, two spectrographs, and a high-speed photometer is supplemented by three fine-guidance sensors that can be used for astronomy as well as for star tracking. A widely reported spherical aberration in the primary mirror causes HST to produce images of much lower quality than intended. A Space Shuttle repair mission in January 1994 installed small corrective mirrors that restored the full intended optical capability of the HST. A Second Servicing Mission (SM2) scheduled in 1997 will involve considerable Extra Vehicular Activity (EVA). To reduce EVA time, the addition of robotic capability in the remaining servicing missions has been proposed. Toward that end, two concept designs for a general purpose end effector for robots are presented in this report.

Naik, Dipak↗

Interchangeable end effector tools utilized on the protoflight manipulator arm

A subset of teleoperator and effector tools was designed, fabricated, delivered and successfully demonstrated on the Marshall Space Flight Center (MSFC) protoflight manipulator arm (PFMA). The tools delivered included a rotary power tool with interchangeable collets and two fluid coupling mate/demate tools; one for a Fairchild coupling and the other for a Purolator coupling. An electrical interface connector was also provided for the rotary power tool. A tool set, from which the subset was selected, for performing on-orbit satellite maintenance was identified and conceptionally designed. Maintenance requirements were synthesized, evaluated and prioritized to develop design requirements for a set of end effector tools representative of those needed to provide on-orbit maintenance of satellites to be flown in the 1986 to 2000 timeframe.

Source record↗

End-effector - joint conjugates for robotic assembly of large truss structures in space: A second generation

Current designs, a first generation intended for robotic assembly, have given priority to the ease and certainty of the assembly process under less than ideal conditions with a minimum of sensory feedback. As a consequence they are either heavy or expensive and all exhibit a relatively low packaging density. Low packaging density is caused by extensive scars applied to the node, increasing its envelope diameter by as much as 150 percent. Strut envelopes are violated to a lessor extent with diameters increased by 25 percent or more. This smaller percentage is still a significant problem owing to a much higher fraction of the packaged volume represented by struts. As structures in space become larger, packaging density becomes an important consideration. The objective is to develop end-effector-joint conjugates that do not violate the envelopes of a 2.5 inch diameter node or a 1.0 inch diameter strut.

Brewer, W. V.↗