Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy efficiency measure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

University of Miami Industrial Assessment Center (Final Scientific/Technical Report)

The University of Miami Industrial Assessment Center (MIIAC) is located at the Department of Industrial & Systems Engineering in the College of Engineering at University of Miami. The Center has conducted 402 energy assessments with estimated Total Energy Savings over $\$57.3$ million, Total Non- Energy Cost Savings of $\$23.7$ million, and Total Energy Saving as a 26% of Energy Costs of $\$311$ million. A total of 6.01 TBtu of energy savings were recommended as a result of energy efficiency measures resulting in $\$81$ million in cost savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Assessment of High Efficiency Variable Speed Air-Source Heat Pump in Cold Climate Applications

This project was part of an effort by ComEd's emerging technology program to evaluate the energy saving potential of new energy efficiency technologies. The focus of this technology assessment was to determine energy and peak demand savings potentials of a high efficiency variable speed, air-source, split system heat pump designed for cold climate applications. The results of this technology assessment will be used by CLEAResult to develop a new energy efficiency measure for Commonwealth Edison Company's incentive programs. The project utilized the National Renewable Energy Laboratory's (NREL) Thermal Test Facility to experimentally characterize cooling and heating performance of a high efficiency heat pump split system under varying outdoor climate conditions. The selected climate conditions represented summer and low temperature winter conditions in ComEd's service territory. The laboratory experimentation results were used to develop equipment performance curves required by EnergyPlus hourly simulation engine. Using typical meteorological year 3 weather data for the Chicago O'Hare airport, hourly building simulations (using the EnergyPlus engine) was utilized to estimate the annual energy savings of the high efficiency heat pump in comparison to a standard efficiency unit in the following U.S. Department of Energy (DOE) building codes program energy prototypes: Single-family residence; Strip mall; and Low-rise office.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S.-China Clean Energy Research Center Building Energy Efficiency (CERC-BEE) Open-Source Retrofit Targeting Tool (CRADA FP00007338 Final Report)

To increase the cost-saving energy and carbon dioxide (CO 2 ) emissions reductions in buildings and portfolios at the scale and speed necessary to limit climate change, researchers at LBNL and Johnson Controls (JCI) developed the Building Efficiency Targeting Tool for Energy Retrofits (BETTER). BETTER is a software tool that consists of three components: (1) the BETTER analytical engine source code (which was developed with intellectual property provided by JCI under CRADA FP00007338); (2) the BETTER web application, developed by LBNL and McQuillen Interactive Pty. Ltd; and (3) the BETTER application programming interface (API), also developed by LBNL and McQuillen Interactive Pty. Ltd. BETTER enables building and portfolio owners, managers, and service providers worldwide to quickly, easily identify cost-saving energy efficiency retrofits in existing buildings and portfolios without expensive site visits or complex modeling. With minimal data input, the tool benchmarks a building’s electric and fossil energy usage against peers; quantifies energy, cost and greenhouse gas (GHG) emission reduction potentials at the building and portfolio levels; and recommends energy efficiency measures to decarbonize and electrify buildings and portfolios, targeting specific energy savings levels. No other tool so comprehensively analyzes buildings and portfolios with such ease. If fully implemented, it is estimated that BETTER could help reduce emissions equivalent to planting 1.3 billion trees globally by 2030. Moreover, an additional 50-75% of embodied GHG emissions could be avoided in each case where BETTER results in a building being retrofitted instead of demolished and replaced, providing substantial additional decarbonization benefits for the buildings sector. BETTER has garnered multiple awards and avid interest from investors. In 2020, it earned a R&D 100 Award for innovation and a LBNL Director’s Award for Technology Transfer. In 2021, BETTER was named an EarthX E-Capital Summit Climate Tech Prize semi-finalist

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NC State University Industrial Assessment Center. Final Report

This report documents work from the Industrial Assessment Center program at NC State University. The program is funded by the US Department of Energy Advanced Manufacturing Office. The IAC provides energy conservation assessments for small and medium sized manufacturers in NC, SC, and VA. Students are involved in all aspects of the assessment including the on-site visit, interacting with plant personnel, collecting data, performing engineering analyses on potential energy efficiency measures, and producing a technical report for the client.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Tool to Incorporate Non-Energy Impacts in Energy Efficiency Investment Decision Making for Firms

Energy efficiency is a key demand-side strategy for sustainability, recently identified by the United States Department of Energy as a pillar of industrial decarbonization. The increased focus on decarbonization and the requirement for efficiency to enable electrification, another decarbonization pillar, due to the spark spread between natural gas and electricity prices, make energy efficiency increasingly relevant. Still, industries face challenges in adopting energy efficiency measures. Researchers have long found a gap in adoption of even those measures with a profitable net present value, attributed to lack of strategic value among other barriers (see for rigorous exploration and taxonomy). One solution to facilitate energy efficiency projects is the inclusion of non-energy impacts, as this has been shown to double potential deployment of such projects at system level. Energy efficiency can provide valuable benefits outside of simple operating cost reductions, from decreased pollution to enhanced productivity. The inclusion of these benefits in decision making assessments faces hurdles due to inconsistency of ancillary benefits across projects, difficulties in quantifying impacts and the need for additional measurement to quantify them. The decision-making tools to support this have been designed primarily for the European context. We begin with a stakeholder engagement process to better characterize the U.S. decision making process surrounding adoption of energy efficiency investments. Characterization of non-energy impacts has developed substantially over recent decades. Cagno et al. provided a framework for studying the applicability of these impacts to energy efficiency projects, listing 120 key performance indicators focused mainly on reductions of costs/harms. Other researchers have included impacts on the strategic and revenue side that can be merged into this framework as well. We seek a tractable set of impacts that can be included in a decision-making tool in the US, and as such are well suited to US industry, management and decision making processes. We also seek to understand how to best quantify or characterize these impacts. This work will demonstrate the results of a survey conducted among US manufacturing industry decision makers to assess the decision making landscape of stakeholders as well as the most relevant performance indicators for energy efficiency projects.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Unlocking Energy Efficiency: Debunking Myths on the Road to Decarbonization

Energy efficiency is widely recognized as the foundational and most critical strategy for decarbonizing the manufacturing sector. Misconceptions surrounding energy efficiency measures often hinder their widespread adoption. This article aims to debunk five common myths and provides data and resources to help implement efficiency projects faster and more effectively to achieve greater decarbonization. First, the article challenges the myth that organizations have exhausted all possible energy efficiency opportunities by achieving voluntary energy intensity goals or energy performance certification. Second, it also addresses the misconceptions that efficiency projects are capital-intensive, require many qualified specialists, and have long investment return periods. By presenting real-world case studies and referencing commonly found efficiency opportunities, the article illustrates that energy-savings opportunities are ubiquitous. Organizations can use various contracting mechanisms as well as financial and technical resources from utility companies and government programs to lessen their burden. The notion that efficiency measures can be implemented solely in proprietorship facilities is dispelled. This article emphasizes the importance of green leases and explains that aligning decarbonization goals between the lessor and lessee can help drive savings for both parties. Finally, using unbundled renewable energy certificates as the sole pathway to decarbonization is strongly discouraged. By debunking these prevalent myths, this article aims to foster a deeper understanding of energy efficiency’s potential as a cornerstone of decarbonization efforts and to embrace it as a critical pathway toward a sustainable future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FINAL TECHINICAL REPORT THUNDERING BUFFALO HEALTH AND WELLNESS CENTER

This U.S. Department of Energy, Office of Indian Energy supported project consists of energy conservation measures (ECMs) and a solar photovoltaic (PV) system to reduce cost of utility bills in a newly constructed Fort Peck Wellness Center, for use by tribal members in improving their physical and mental wellness. Construction of the building was outside the scope of the DOE supported project. A new 2-story wellness center was designed and constructed in Poplar, Montana. The wellness center is comprised of fitness areas, gymnasium, pool and spa, offices, and BOH support areas. The building was completed and has been operational for more than a year. A final measurement and verification of energy savings was completed after one year of operation and the results are presented herein, showing an energy savings 20% higher than the originally models indicated.

14 SOLAR ENERGY↗

Senior Housing Complex Energy Efficiency and Solar Energy Project

As part of a longer-term energy efficiency and solar development program on the Coeur d'Alene reservation, the Coeur d'Alene Tribe completed energy efficiency measures and deployed a solar photovoltaic system at its Senior Housing Complex. The project generated nearly 68,000 kWh of solar energy in its first year, and reduced energy used at the senior housing complex by 95,192 kWh, saving $7,144.56 in energy costs, and saving 48.1 metric tons of carbon dioxide.

14 SOLAR ENERGY↗

South Africa: Framework for Energy Efficiency Demand Side Management

In July 2022, President Cyril Ramaphosa announced an emergency response plan to address the growing electricity crisis in South Africa, which included the necessity for customers of Eskom, South Africa’s primary electricity supplier, to implement demand-side energy efficiency measures. This report is the second of two reports that provides the foundation for a strategic Demand-Side Management (DSM) approach to reduce load shedding and maximize energy savings in South Africa, though inter-governmental collaboration and increased coordination of energy efficiency activities. The first report focuses on the experience of Eskom’s rate-funded Integrated Demand Management (IDM) programme, from its beginning in 2004 to today, highlighting the factors that led to failed support for the programme. This second report focuses on addressing the challenges identified in the first report and describes the elements of a policy framework to develop a sustained DSM program to meet the government’s energy efficiency goals in terms of greenhouse gas emissions reduction and social equity and inclusion to achieve a just transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scaling Up Energy Efficiency Investment in Emerging Markets - Private Sector Perspectives

Since 2000, electricity demand has flattened and decoupled from Gross Domestic Product (GDP) growth in the Organization for Economic Cooperation and Development (OECD) countries. This trend is anticipated to continue for the next several decades and is largely attributed to the implementation of energy efficiency measures. However, non-OECD countries (emerging markets) have experienced, and are projected to continue experiencing, increasing electricity demands. If the world is to meet the requirements of the Paris Agreement, annual investments in clean energy and energy efficiency need to increase by a factor of six by 2050, compared to 2015. Information presented in this paper is based on qualitative and quantitative data collection and analysis methods to provide an empirical understanding of barriers to private sector clean energy investment including microgrid development, energy efficiency, smart grid development, and utility-scale wind and solar in emerging markets. Through literature review, a survey, and a series of webinar dialogues, USAID and the U.S. Department of Energy National Renewable Energy Laboratory (NREL) solicited input from private sector actors, including developers, project financiers, manufacturers and technical assistance service providers, on the challenges they face to market entry in emerging markets, and their suggestions for improving market competitiveness.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EVALUATING FACILITY ENERGY EFFICIENCY AND RESILIENCE OPPORTUNITIES WITH FEDS AND MCOR

Energy resilience has become increasingly important for critical building infrastructure, in response to concerns over potential disruptions to the electrical grid from threats both natural and man-made. Energy efficiency can provide a valuable resource for reducing critical loads and therefore lowering the cost of supplying alternative power. This paper highlights two tools that are well-suited for analyzing building energy efficiency and resilience opportunities and presents a case study for their combined application. The Facility Energy Decision System (FEDS) and Microgrid Component Optimization for Resilience (MCOR) tools can be used together to simulate building systems, identify energy efficiency measures, and evaluate resilience options for powering a site during an outage.

FEDS, MCOR, Energy Efficiency, Resilience, Simulat↗

Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates

Energy efficiency measures, such as cool roofs, radiant barriers, interior radiative control coatings, and buried ducts are increasing in popularity and are promoted by energy codes because of their energy-saving potential. However, these strategies can also pose moisture risks in attics by lowering surface temperatures and increasing condensation potential and moisture accumulation. Of particular concern in hot-humid climates is dripping condensation on cold air-conditioning ductwork in the summer - commonly referred to as duct "sweating" - which threatens the attic floor with conditions conducive to mold growth and rot. One strategy to mitigate these moisture issues is to wrap ductwork in thicker duct-wrap insulation with an integrated exterior vapor barrier, but thick duct wrap can be difficult to come by, expensive, and unwieldy to work with. This study explores an alternative strategy of reducing moisture issues while embracing energy efficiency by using unvented attics with vapor diffusion ports and buried ductwork in hot-humid climates. Vapor diffusion ports have been studied so far in a wide range of U.S. climates, mostly in the context of conditioned attics. In this study, the strategy is implemented in the novel context of hot-humid climates with ductwork sitting atop blown-in attic floor insulation in unconditioned attics. Using a combination of field experiments and hygrothermal modeling, the findings of this project indicate that an unvented attic with vapor diffusion ports and buried ducts may be a key part of a successful low-cost method for reducing the attic moisture load by venting excess moisture out of the attic, keeping duct-jacket surfaces above dew point temperature, and keeping the roof deck safe from winter moisture accumulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Supply Chain Energy and Greenhouse Gas Analysis Using the Materials Flows Through Industry (MFI) Tool: Examination of Alternative Technology Scenarios for the U.S. Chemical Sector

Chemical manufacturing is a large and diverse sector of the U.S. economy, with products, fuels, and a wide assortment of materials used daily by both the public and businesses. Currently, several of the largest volume chemicals produced in the United States rely on fossil fuels as a feedstock, energy source, or both. The list of chemicals includes steam cracking products such as ethylene, propylene, benzene, and xylenes as well as products such as ammonia and methanol. The focus for this work is on platform chemicals that are both produced in the largest volume and have a high potential for subsequent processing into more specialized products. In this study, we explore several new pathways that reduce the overall energy consumption and greenhouse gas (GHG) emissions for each product. These pathways include energy efficiency measures applied to existing production methods, the use of bio‐based fuels and/or feedstocks as new production methods, and electrification of high‐energy‐input stages within current production methods. Scenarios for energy demand and GHG reduction were conducted with the National Renewable Energy Laboratory's Materials Flows through Industry tool. Projections of the energy demand and GHG emissions in 2030 and 2050 are included, using grid composition projections from the NREL ReEDS model. The alternative scenarios selected showcase the effect of realistic changes the industry could make, focusing on technologies with a high level of technical readiness.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Nexus of thermal resilience and energy efficiency in buildings: A case study of a nursing home

Extreme weather events become more frequent and severe due to climate change. Although energy efficiency technologies can influence thermal resilience of buildings, they are traditionally studied separately, and their interconnections are rarely quantified. This study developed a methodology of modeling and analysis to provide insights into the nexus of thermal resilience and energy efficiency of buildings. In this work, we conducted a case study of a real nursing home in Florida, where 12 patients died during Hurricane Irma in 2017 due to HVAC system power loss, to understand and quantify how passive and active energy efficiency measures (EEMs) can improve thermal resilience to reduce heat-exposure risk of patients. Results show that passive measures of opening windows and doors for natural ventilation, as well as miscellaneous load reduction, are very effective in eliminating the extreme dangerous occasions. However, to maintain safe conditions, active measures such as on-site power generators and thermal storage are also needed. The nursing home was further studied by changing its location to two other cities: San Francisco (mild climate) and Chicago (cold winter and hot summer). Results revealed that the EEMs' impacts on thermal resilience vary significantly by climate and building characteristics. The study also estimated the costs of EEMs to help stakeholders prioritize the measures. Passive measures that may not save energy may greatly improve thermal resilience, and thus should be considered in building design or retrofit. Findings from this study indicate energy efficiency technologies should be evaluated not only by their energy savings performance but also by their influence on a building's resilience to extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗