Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy monitor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Monitoring the Low-Energy Gamma-Ray Sky Using Earth Occultation with GLAST GBM

Long term all-sky monitoring of the 20 keV - 2 MeV gamma-ray sky using the Earth occultation technique was demonstrated by the BATSE instrument on the Compton Gamma Ray Observatory. The principles and techniques used for the development of an end-to-end earth occultation data analysis system for BATSE can be extended to the GLAST Gamma-ray Burst Monitor (GBM), resulting in multiband light curves and time-resolved spectra in the energy range 8 keV to above 1 MeV for known gamma-ray sources and transient outbursts, as well as the discovery of new sources of gamma-ray emission. In this paper we describe the application of the technique to the GBM. We also present the expected sensitivity for the GBM.

Case, G.↗

Future monitoring of charged particle energy deposition into the upper atmosphere and comments on possible relationships between atmospheric phenomena and solar and/or geomagnetic activity

The charged particle observations proposed for the new low altitude weather satellites, TIROS-N, are described that will provide the capability of routine monitoring of the instantaneous total energy deposition into the upper atmosphere by the precipitation of charged particles from higher altitudes. Estimates are given to assess the potential importance of this type of energy deposition. Discussion and examples are presented illustrating the importance in distinguishing between solar and geomagnetic activity as possible causative sources.

Williams, D. J.↗

Improvements in a calorimeter for high-power CW lasers

A technique for improving the measurement certainty with the BB series (Smith et al., 1972) of electrically calibrated calorimeters used in high-energy lasers is described. The technique is based on monitoring the energy which is backscattered from the meter and monitoring the overspill radiation impinging on the calorimeter at the entrance aperture. The design and performance of a second generation BB meter is discussed and compared to that of the original device in terms of number of electrical calibrations, the residual standard deviation of electrical calibration, the calibration constant for laser energy, the correcting factor for systematics, inaccuracy, imprecision, and uncertainty.

Chamberlain, G. E.↗

Energy and Nutrient Intake Monitoring

A passive system to determine the in-flight intake of nutrients is developed. Nonabsorbed markers placed in all foods in proportion to the nutrients selected for study are analyzed by neutron activation analysis. Fecal analysis for each market indicates how much of the nutrients were eaten and apparent digestibility. Results of feasibility tests in rats, mice, and monkeys indicate the diurnal variation of several markers, the transit time for markers in the alimentary tract, the recovery of several markers, and satisfactory use of selected markers to provide indirect measurement of apparent digestibility. Recommendations are provided for human feasibility studies.

Luckey, T. D.↗

(abstract) Low Energy Flux and Spectral Monitoring of Cen A and NGC 4151

We present available BATSE Earth-occultation observations of Cen A (the brightest extragalactic hard X-ray source) and NGC 4151 (the archetypical Seyfert I) from 1991 May through 1992 February, in the 20 keV to 1.5 MeV range. We compare the results with those obtained by OSSE during viewing periods 4 (NGC 4151) and 12 (Cen A). In general Earth-occultation sensitivities achieved by BATSE are a few times poorer than those attainable by OSSE, but sources are observable almost continuously, during all CGRO viewing periods. Data from the two instrumants are thus nicely complementary.

Cen A NGC 4151 X-ray spectra Earth-occultation↗

TPSAS-NF1676L-33912-DND

The agricultural, renewable energy management, and science communities need global surface and top-of-atmosphere (TOA) radiative fluxes on a near real-time basis for uses such as building energy performance monitoring and seasonal crop yield modeling. The Clouds and Earth's Radiant Energy System (CERES) FLASHFlux (Fast Longwave and SHortwave radiative Flux) data products address this need by enhancing the speed of CERES processing using simplified calibration, averaging techniques and fast radiation parameterizations to produce global fluxes within a week of satellite observations. The CERES FLASHFlux provides two data products: 1) an hourly Level 2 Single Scanner Footprint (SSF) data separately for Aqua and Terra observations, and 2) a daily Level 3 Time Interpolated and Spatially Averaged (TISA) 1degree x 1degree gridded data that combines Aqua and Terra observations. The CERES FLASHFlux Version4A includes an update to process MODIS Collection 6.1 in an improved cloud retrieval algorithm, and an update to the CERES Edition 4 angular distribution models. We inter-compared FLASHFlux Version4A, FLASHFlux Version3C, and CERES EBAF (Energy Balanced and Filled) Top-of-Atmosphere fluxes to evaluate these improvements. We also compare both SSF overpass and TISA radiative flux products to a set of surface measurement sites that are globally distributed and assess agreement. FLASHFlux TISA and CERES EBAF are used in the analysis of TOA anomalies for the annual State of Climate report. This also poster highlights the methodology use to merge the two data products by correcting the bias in FLASHFlux TISA and inter-calibrate to CERES EBAF.

Parnchai K Sawaengphokhai↗

Detecting Tooth Damage in Geared Drive Trains

This paper describes a method that was developed to detect gear tooth damage that does not require a priori knowledge of the frequency characteristic of the fault. The basic idea of the method is that a few damaged teeth will cause transient load fluctuations unlike the normal tooth load fluctuations. The method attempts to measure the energy in the lower side bands of the modulated signal caused by the transient load fluctuations. The method monitors the energy in the frequency interval which excludes the frequency of the lowest dominant normal tooth load fluctuation and all frequencies above it. The method reacted significantly to the tooth fracture damage results documented in the Lewis data sets which were obtained from tests of the OH-58A transmission and tests of high contact ratio spiral bevel gears. The method detected gear tooth fractures in all four of the high contact ratio spiral bevel gear runs. Published results indicate other detection methods were only able to detect faults for three out of four runs.

Nachtsheim, Philip R.↗

Laser-induced fluorescence of CN/X2 Sigma +/ produced by photolysis of C2N2 at 160 nm

The paper reports laser-induced fluorescence measurements of the initial product state distributions of CN(X2 Sigma +) produced during the photolysis of C2N2 at a wavelength of 160 nm. The parent molecules were photodissociated by an argon flash lamp, and saturated solutions of BBD in p-dioxane were used as a laser dye to produce radiation that excited CN radicals in the (upsilon-double-prime, N-prime) vibrational-rotational sublevels of the X state to the B-state sublevels. Spectral-line identification is discussed along with the observed rotational, electronic, and vibrational energy partitionings. The effect of added buffer gas (N2 or He) on the observed product state distributions is examined in order to monitor collisional energy transfer from CN(A2 Pi, upsilon = 0) to CN(X2 Sigma +, upsilon-double-prime = 4). It is found that both buffer gases produce population inversion between the upsilon-double-prime = 4 and upsilon-double-prime = 3 levels of the X state.

Cody, R. J.↗

LANDSAT TM image data quality analysis for energy-related applications

This project represents a no-cost agreement between National Aeronautic Space Administration Goddard Space Flight Center (NASA GSFC) and the Pacific Northwest Laboratory (PNL). PNL is a Department of Energy (DOE) national laboratory operted by Battelle Memorial Institute at its Pacific Northwest Laboratories in Richland, Washington. The objective of this investigation is to evaluate LANDSAT's thematic mapper (TM) data quality and utility characteristics from an energy research and technological perspective. Of main interest is the extent to which repetitive TM data might support DOE efforts relating to siting, developing, and monitoring energy-related facilities, and to basic geoscientific research. The investigation utilizes existing staff and facility capabilities, and ongoing programmatic activities at PNL and other DOE national laboratories to cooperatively assess the potential usefulness of the improved experimental TM data. The investigation involves: (1) both LANDSAT 4 and 5 TM data, (2) qualitative and quantitative use consideration, and 3) NASA P (corrected) and A (uncorrected) CCT analysis for a variety of sites of DOE interest. Initial results were presented at the LANDSAT Investigator's Workshops and at specialized LANDSAT TM sessions at various conferences.

Wukelic, G. E.↗

Development of environmental charging effect monitors for operational satellites

An instrumentation package to monitor the effects of the environmental charging of spacecraft surfaces on the systems of operational spacecraft was developed. This package performs two functions: first, the local charged particle flux and the particle characteristic energy is monitored; and second, transients in the spacecraft electrical harness is counted as a function of amplitude, with time. It is used to determine the duration and effect of any environmental charging of the spacecraft surfaces. Thus, it will be possible to determine the relationship between the occurrence of any anomalies and the charging phenomenon. Design details and design goals of this package are presented.

Stevens, N. J.↗

A compact spectroradiometer for solar simulator measurements

Compact spectral irradiance probe has been designed and built which uses wedge filter in conjunction with silicon cell and operational amplifier. Probe is used to monitor spectral energy distribution of solar simulators and other high intensity sources.

Seward, H. H.↗

Prediction of the occurrence and intensity of magnetospheric substorms

The solar wind and IMF data obtained by the Venus probe Mariner 5 (at a distance of 460 earth radii) and by the earthbound Explorer 34 satellite, on June 24, 25, and 26, 1967 were examined. It is demonstrated that the occurrence and intensity of magnetospheric substorms can be predicted about 1-3 hours prior to their onsets by monitoring the energy coupling function at a distance of a few hundred earth radii upstream of the solar wind. It appears that the 'epsilon signal' propagates with different speeds, perhaps depending on the propagation time of disturbances which increase epsilon.

Akasofu, S.-I.↗

Laser remote sensing of atmospheric temperature by observing resonant absorption of oxygen

A dual-frequency system is used to demonstrate the measurement of atmospheric temperature, through laser energy absorption monitoring at the center of an O2 resonant absorption line near 770 nm. It is shown that the average temperature of a 1 km path can be determined within 1.0 C, with a noise level of 0.3 C. An iterative algebraic expression for this method was developed, and is shown to be applicable in the troposphere; the effects of pressure and humidity on temperature determination were made clear by the algorithm and found to be small near the earth's surface.

Kalshoven, J. E., Jr.↗

Nighttime observations of 0.2- to 26-keV electrons in the South Atlantic anomaly made by Atmosphere Explorer C

Atmosphere Explorer C satellite observations have determined that the flux of low energy ions in the South Atlantic Anomaly is much smaller than that of electrons, allowing the satellite's low-energy ion detector to monitor the high-energy background and correct the low-energy electron detector accordingly. It is shown that the electron spectra can be represented by a power law in the range 0.2-26.0 keV, with the spectral index close to -1.0, and that the mean energy flux carried by electrons in the middle of the anomaly is about 0.003 erg/sq cm/sec and may reach 5 times this value. Maps of the downward energy flux are included.

Gledhill, J. A.↗

Resonant power processors. II - Methods of control

The nature of resonant converter control is discussed. Employing the state-portrait, different control methods for series resonant converter are identified and their performance evaluated based on their stability, response to control and load changes and range of operation. A new control method, optimal-trajectory control, is proposed which, by utilizing the state trajectories as control laws, continuously monitors the energy level of the resonant tank. The method is shown to have superior control properties especially under transient operation.

Oruganti, R.↗