Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy storage system model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Optimal Coordination of Distributed Energy Resources Using Deep Deterministic Policy Gradient

Recent studies showed that reinforcement learning (RL) is a promising approach for coordination and control of distributed energy resources (DER) under uncertainties. Many existing RL approaches, including Q-learning and approximate dynamic programming, are based on lookup table methods, which become inefficient when the problem size is large and infeasible when continuous states and actions are involved. In addition, when modeling battery energy storage system (BESS), the loss of life is not reasonably considered into the decision-making process. This paper proposes an innovative deep RL method for DER coordination considering BESS degradation. The proposed deep RL is designed based on an adaptive actor-critic architecture and employs an off-policy deterministic policy gradient method for determining the dispatch operation that minimizes the operation cost and BESS life loss. Case studies were performed to validate the proposed method and demonstrate the effects of incorporating degradation models into control design.

Das, Avijit↗

A Learning-based Supervisory Control Architecture for Electric Vehicle Charging System Paired with Energy Storages

A Machine Learning-based predictive model is developed for optimal dispatching energy storage system integrated with Electric Vehicle battery charger. The model is effectively trained using transfer learning algorithm and successfully validated via measurement data to achieve high fidelity and accuracy. The study findings provide possibilities for future development of the presented approach to implement computational heavy predictive algorithms with multi-step predictions in emerging modular bidirectional charger topologies to realize vehicle-to-grid (V2G) technology. The online tuning can be explored using the new measurements obtained during the operation, henceforth, enhancing the controller performance for integrating multiple DERs into distribution power networks that shows huge interest for the utilities and regulatory agencies. Multiple operation scenatios have been evaluated and simulation results are discussed to verify intended performance of the proposed control solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mean-field control for efficient mixing of energy loads

In this work, we pose an engineering challenge of controlling an ensemble of energy devices via coordinated, implementation-light, and randomized on/off switching as a problem in nonequilibrium statistical mechanics. We show that mean-field control with nonlinear feedback on the cumulative consumption, assumed available to the aggregator via direct physical measurements of the energy flow, allows the ensemble to recover from its use in the demand response regime, i.e., transition to a statistical steady state, significantly faster than in the case of the fixed feedback. Moreover when the nonlinearity is sufficiently strong, one observes the phenomenon of “super-relaxation,” where the total instantaneous energy consumption of the ensemble transitions to the steady state much faster than the underlying probability distribution of the devices over their state space, while also leaving almost no devices outside of the comfort zone.

25 ENERGY STORAGE↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Real-time Simulation Model of a Vanadium Redox Flow Battery Energy Storage System with Power Electronics Integration

This paper presents a real-time (RT) model of a 20 kW multi-stack vanadium redox flow battery (VRFB) system including power electronics converters in a single real-time framework. Implemented on a Typhoon HIL 604 device, this model is designed to simulate the operation of the flow battery with system-level controls. To provide a realistic overview of a VRFB system, the model incorporates a closed-loop control system for managing the speeds of two centrifugal pumps and an electro-thermal model of the battery stacks, enabling realtime temperature estimation. Furthermore, a two-stage power electronics topology and associated control solution are presented, operating with distinct strategies for interfacing the battery model with the main grid and a local load. Results from simulations demonstrate that the VRFB model is well suited for RT environment, and system can manage power during both charging and discharging cycles, while a SCADA monitor is used to display critical variables for safe, efficient, and reliable operation of the VRFB systems.

Rezende Da Costa Reis Kimpara, Renata [ORNL] (ORCI↗

The Importance of Modeling Carbon Dioxide Transportation and Geologic Storage in Energy System Planning Tools

Energy system planning tools suggest that the cost and feasibility of climate-stabilizing energy transitions are sensitive to the cost of CO 2 capture and storage processes (CCS), but the representation of CO 2 transportation and geologic storage in these tools is often simple or non-existent. We develop the capability of producing dynamic-reservoir-simulation-based geologic CO 2 storage supply curves with the Sequestration of CO 2 Tool (SCO 2 T) and use it with the ReEDS electric sector planning model to investigate the effects of CO 2 transportation and geologic storage representation on energy system planning tool results. We use a locational case study of the Electric Reliability Council of Texas (ERCOT) region. Our results suggest that the cost of geologic CO 2 storage may be as low as $3/tCO 2 and that site-level assumptions may affect this cost by several dollars per tonne. At the grid level, the cost of geologic CO 2 storage has generally smaller effects compared to other assumptions (e.g., natural gas price), but small variations in this cost can change results (e.g., capacity deployment decisions) when policy renders CCS marginally competitive. The cost of CO 2 transportation generally affects the location of geologic CO 2 storage investment more than the quantity of CO 2 captured or the location of electricity generation investment. We conclude with a few recommendations for future energy system researchers when modeling CCS. For example, assuming a cost for geologic CO 2 storage (e.g., $5/tCO 2 ) may be less consequential compared to assuming free storage by excluding it from the model.

20 FOSSIL-FUELED POWER PLANTS↗

Reactive transport modeling of the Aquifer Thermal Energy Storage (ATES) system at Stockton University, New Jersey during seasonal operations

Hydrogeochemical processes associated with Aquifer Thermal Energy Storage (ATES) operations can often impact the system performance owing to mineral precipitation either at the wellbore or in the aquifer owing to changes in temperature and fluid disequilibria. Although failure of ATES systems due to mineral precipitation ("fouling") is common, predictive reactive-transport models have rarely been applied to plan their design and operation. Here, the objective of this study is to develop a reactive-transport model by coupling thermal, hydrological, and chemical (THC) processes to evaluate effects of introduced atmospheric oxygen on water chemistry, mineral precipitation/dissolution, porosity, and permeability changes associated with an ATES system at Stockton University (New Jersey, USA). The THC model builds on a Thermal-Hydrological-Mechanical (THM) model of the site that evaluated system failure owing to possible fracturing in the caprock or around the wellbore. The causes of the system failure are not known – potential causes include hydraulic fracturing owing to elevated pump pressures that took place, a flow pathway created by one of the boreholes, or a pre-existing natural hydrologic connection between the upper unconfined aquifer and the ATES aquifer, any of which could have led to oxygenated water entering the reservoir and causing the observed Fe-oxide fouling on well screens. The THC model is used to evaluate some of the hypotheses and observations regarding system failure owing to geochemical processes. The reactive-transport code TOUGHREACT V4 was used to model the THC processes during seasonal heating and cooling operations at the Stockton ATES site over 6 years of operation. In the THC simulations, the primary effects on geochemistry were observed when the injection water is saturated with atmospheric oxygen. Simulations show greater precipitation of goethite near the cold wells as compared to the warm wells. Although volume fractions of Fe-hydroxides were relatively small, the model was aimed at processes in the aquifer at the scale of meters and larger rather than at the scale of mm or cm (i.e., a well screen). Kaolinite is the dominant precipitating phase, also around the cold wells. Illite dissolves near the cold wells and precipitates near the warm wells. There is a net decrease in the porosity near the cold wells and increase near the warm wells, although a slight amount of thermal contraction near the cold wells and expansion near the warm wells is responsible for a significant proportion of the porosity change. Owing to the coarse discretization of the numerical grid near the wells (compared to the screen thickness) the magnitude of permeability changes at the wellbore are likely underestimated. The reactive transport model in this study can be used for characterization of aquifers, optimizing the operational parameters (temperature, pressure, pH etc.), and planning of mitigation strategies for ATES systems.

15 GEOTHERMAL ENERGY↗

Enhanced Inertial Support: Modeling Fast Frequency Response Controls for Energy Storage System Inverters

Reduction of power system inertia is a growing concern for grid operators given the transition under way from conventional fossil generators to inverter-based resources. One key concern is the rapid and severe dip in power system frequency following a large disturbance which could trigger remedial actions including operation of under frequency load shedding (UFLS) relays. A potential solution is to utilize battery energy storage systems (BESS) to provide fast frequency response(FFR) to mitigate the system frequency impact of low system inertia. In this work, we investigate different control parameters to achieve modeled FFR response from BESS in the simulated US Western Interconnection. First, a very low inertia model is developed from an existing positive sequence model of the Western Interconnection. Afterwards, we tune the BESS dynamic response parameters to eliminate any risks of reaching UFLS relay thresholds following the loss of large generators. Finally, we investigate the relative impact of having large BESS units in comparison of multiple smaller units in the same area. The results of the analyses indicate that 1 GW of transmission-connected BESS can help mitigate the frequency drop caused by large generators outages in the Western Interconnection, and significantly reduce the risk of under frequency load shedding.

power system dynamic performance, Low Inertia, Fas↗

Status Report on FY2022 Model Development within the Integrated Energy Systems HYBRID Repository

This publication details newly created energy storage models developed within the HYBRID Modelica repository as part of the Department of Energy Office of Nuclear Energy (DOE-NE) Integrated Energy Systems (IES) program, led by Idaho National Laboratory (INL). Model development to-date includes creation of dynamic systems-level models of a pebble bed high temperature gas reactor (HTGR), liquid air energy storage (LAES), and compressed air energy storage (CAES) in the IES-based HYBRID repository. Models are developed using the latest publicly available data and incorporate the possibility of control strategy inclusion for use with the existing IES modeling, analysis, and optimization toolset. Simulations showcase the abilities of each technology to flexibly operate in ways consistent with IES operation expectations. When these models are available, they can be utilized within different integrated energy park concepts to understand optimal system operation, control, and dispatching. Moreover, given the generic nature of the models, industrial partner technologies can be quickly added to the repository using the existing models as a basis. Additional dynamic models for thermal energy storage concepts can be developed and added to the HYBRID repository as needed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Isothermal Versus Sensible Cold Storage: A Model-Based Performance Comparison for Pumped Thermal Electricity Storage

Pumped-thermal energy storage (PTES) systems consume and produce electrical energy using thermal storage media as an intermediate stage. PTES lends itself to long-duration energy storage to facilitate high penetration of intermittent electricity generation. This study presents a model-based comparison of two thermal storage types within a PTES system: a conventional, single-phase, stratified water-glycol sensible storage system (SGS), and an ideal isothermal, two-phase heat exchanger that freezes a water reservoir (isothermal heat exchanger (IHEX)). The SGS thermal storage capacity is based on the liquid’s sensible heat change with temperature, whereas the capacity of the IHEX is based on the latent heat of isothermally freezing and melting water. The idealized IHEX modeled here undergoes steady-state melting and freezing (in contrast to transient rates, as observed with ice-on-coil storage). A computational model of a complete PTES system is presented and used to evaluate the PTES system-level performance with each type of cold storage. Compared to SGS-based PTES, under nominal operating conditions, the IHEX-based PTES increased electrical round-trip efficiency from 61% to 82% and increased energy density from 1.13 to 8.09 kWh/m 3 In conclusion, the performance of the PTES configured with IHEX storage was also analyzed under varying operating parameters.

25 ENERGY STORAGE↗

Model predictive control for optimal dispatch of chillers and thermal energy storage tank in airports

Cost of energy consumption is one of the biggest operational cost for airports, and it is increasing from time to time as airports expand to support growing number of passengers. Various factors affect the energy consumption including efficiency of airport Heating Ventilation and Air conditioning (HVAC) systems, which in turn depends on the efficiency of individual subsystems. Here, in this paper, we present an optimal scheduling method for the central plant system at Dallas Fort Worth airport, involving chillers, pumps, and a thermal energy storage (TES) system. A model predictive control (MPC) problem is formulated to minimize both energy and demand charge costs while satisfying the cooling needs of the airport. The proposed Mixed-Integer Nonlinear Programming (MINLP) formulation includes performance curve based models for chillers and pumps and a simplified state of charge model for TES. The formulation also includes predictions of cooling load and chilled water return temperature. Simulation results for a month in summer show savings around 10% compared to the baseline. Initial recommendations based on insights from simulation results to the manual operation procedures resulted in significant savings. Field test results show a 7% chiller efficiency improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Economic Impact of Battery Degradation Modelling Uncertainty

Battery energy storage systems (BESS) are used for a variety of applications, with their economic benefit often being the decisive factor for deployment. A multitude of physico-chemical aging mechanisms lead to capacity fade over a BESS life cycle. The models that are used to describe this capacity fade are prone to inherent model errors. Through a holistic techno-economic modelling approach, we investigate the impact of battery degradation modelling uncertainty on the economic benefit of representative BESS applications. Here, it is shown how improved parameter fit quality can reduce the resulting economic uncertainty. Furthermore, we highlight that the consideration of degradation modelling uncertainty is especially crucial when: (i) the cash flow highly depends on the available battery capacity, (ii) a fixed, e.g. warranty mandated, state of health limit acts as the threshold for battery end-of-life, (iii) long evaluation periods and low discount rates are the focus of economic evaluation.

aging↗

Follow-On Status Report on FY2022 Model Development within the Integrated Energy Systems Hybrid Repository

This publication details newly created energy storage and reactor models developed within the HYBRID modeling repository as part of the Department of Energy Office of Nuclear Energy (DOE-NE) Integrated Energy Systems (IES) program, led by Idaho National Laboratory (INL). Model development to-date includes creation of dynamic systems-level models of a pebble bed high temperature gas reactor (HTGR), compressed air energy storage (CAES), and Modelica standard library based two-tank sensible heat storage (SHS) in the IES-based HYBRID repository. Models are developed using the latest publicly available data and incorporate the possibility of control strategy inclusion for use with the existing IES modeling, analysis, and optimization toolset. Simulations showcase the abilities of each technology to flexibly operate in ways consistent with IES operation expectations. When these models are available, they can be utilized within different integrated energy park concepts to understand optimal system operation, control, and dispatching. Moreover, given the generic nature of the models, industrial partner technologies can be quickly added to the repository using the existing models as a basis. Additional dynamic models for thermal energy storage concepts can be developed and added to the HYBRID repository as needed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks: Q1 2021

NREL has been modeling U.S. solar photovoltaic (PV) system costs since 2009. This year, our report benchmarks costs of U.S. PV for residential, commercial, and utility-scale systems, with and without storage, built in the first quarter of 2021 (Q1 2021). The methodology includes bottom-up accounting for all system and project-development costs incurred when installing residential, commercial, and utility-scale systems and it models the capital costs and levelized cost of energy for such systems.

14 SOLAR ENERGY↗

Sparse chronology strategy for integrating seasonal energy storage in capacity expansion models

Here, this study develops the sparse chronology method to enhance the representative period framework in capacity expansion models, enabling the effective integration of long-duration energy storage modeling. Traditional representative period methods cannot capture the state of charge of seasonal energy storage systems because they do not establish effective inter-day linkages to connect the state of charge between periods. The sparse chronology approach addresses this limitation by establishing inter-day linkages that allow state of charge to shift inter-seasonally. At the same time, it groups identical representative days into partitions, applying constraints sparsely and implicitly to reduce computational load further. Validation results demonstrate that this method successfully simulates long-duration energy storage patterns, achieving close alignment with a continuous yearly benchmark model, with seasonal trends and state of charge cycles clearly represented. The computational load analysis reveals that the sparse chronology method efficiently applies constraints on maximum and minimum state of charge limits within the representative day framework, eliminating the need for detailed constraints on each individual day. By partitioning representative days and constraining only the start and end of each partition, the method significantly decreases computational requirements. Simulation results show that sparse chronology closely approximates the continuous yearly method's accuracy, even with as few as 20 representative days, achieving correlation values with the benchmark of nearly 0.9 in state of charge plots. Furthermore, it maintains computational efficiency, requiring only 4 % of the solver time compared to the continuous yearly method with 20 representative days. This approach allows capacity expansion models to incorporate long-duration energy storage with high temporal, spatial, and technological resolution, enabling more detailed modeling for large-scale power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

One System, Many Models: Designing a Surrogate Model for Sulfur Thermal Energy Storage: Preprint

Industrial process heating (IPH) relies primarily on thermal energy generated by fossil fuel combustion to produce, treat, and alter manufactured goods. Thermal energy storage (TES) helps reduce the carbon footprint of IPH systems by facilitating the utilization of renewable and waste heat sources. A promising new TES technology uses elemental sulfur as the heat-storage medium. The design of sulfur TES systems can be evaluated with the aid of computational fluid dynamics (CFD). However, the computational cost of such CFD efforts is prohibitive to comprehensive optimizations over design parameters. To reduce this computational cost, machine learning (ML) models can be developed to act as surrogates for CFD. In this paper, we describe the process of building and evaluating surrogate ML models for facilitating optimization of sulfur TES systems for IPH. To enforce the thermodynamic relationship between the two modeled quantities, we develop a hybrid model for sulfur temperature using both direct predictions of temperature and calculations of temperature from predictions of the heat transfer coefficient. The hybrid model enforces this constraint at the expense of the slightly reduced accuracy compared to two disjoint models. The overall high accuracy observed in our model evaluation demonstrates the usefulness of such surrogate modeling for studying TES systems. This work contributes to the field of TES surrogate modeling by offering a novel accurate hybrid approach to predicting simultaneously the heat transfer coefficient and temperature of the heat storage medium.

computational fluid dynamics↗