Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Probabilistic Analysis of Long-Term Degradation of Microwave Cavity Flow Sensor

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. We have performed a proof-of-concept experiment of flow sensing with the transducer in liquid sodium at 340°C in impinging liquid jet geometry. The transducer remained in liquid sodium for 70 days. After removal, no structural damage was observed, and the expected transducer response was verified in a water test. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance. Since a yellowish residue was observed on the transducer surface after 70 days of immersion in liquid sodium, we have investigated possible evidence of corrosion. Chromium depletion is a typical indicator of the corrosion process in stainless steel. Scraping off a residue from the transducer and performing scanning electron microscopy (SEM) with energy dispersive analysis (EDS) did not find any chromium in the residue. Approximately 60% of the residue consisted of copper, which can be attributed to contamination of sodium due to powder residue from machining of copper and brass components of the transducer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimization of In-Field Alpha Spectrometry for Uranium Enrichment Determination in Uranium Hexafluoride

In response to needs identified by the International Atomic Energy Agency (IAEA) research is underway to develop In-Field Alpha Spectrometry (IFAS) as a method to allow IAEA safeguards inspectors to collect samples of uranium hexafluoride (UF6) at processing facilities to assess and verify uranium enrichment. For sample collection, the IFAS method uses Single-Use Destructive Assay (SUDA) samplers, which contain thin zeolite coatings that trap UF6 gas and convert it to the safer, more stable form uranyl fluoride (UO2F2). For alpha spectrometry, the IFAS instrument employs a large area silicon semiconductor transducer to detect and record alpha particle energy-deposition events. Over the past year optimization work has significantly increased the diameter of useful SUDA samples (from 12.7 mm to 48 mm), improved the manufacturability and reproducibility of SUDA samples, increased the area of the IFAS alpha spectrometer sensor from 1.2 cm to 3.1 cm, and improved source positioning within the IFAS. This paper will report on this optimization work, its impacts on IFAS performance, and future plans for IFAS miniaturization, improvements, and testing.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Optimization Of In-field Alpha Spectrometry For Uranium Enrichment Determination In Uranium Hexafluoride

In response to needs identified by the International Atomic Energy Agency (IAEA) research is underway to develop In-Field Alpha Spectrometry (IFAS) as a method to allow IAEA safeguards inspectors to collect samples of uranium hexafluoride (UF6) at processing facilities to assess and verify uranium enrichment. For sample collection, the IFAS method uses Single-Use Destructive Assay (SUDA) samplers, which contain thin zeolite coatings that trap UF6 gas and convert it to the safer, more stable form uranyl fluoride (as a dihydrate, UO2F2·2H2O). For alpha spectrometry, the IFAS instrument employs a large area silicon semiconductor transducer to detect and record alpha particle energy-deposition events. Over the past year optimization work has significantly increased the diameter of useful SUDA samples (from 12.7 mm to 48 mm), improved the manufacturability and reproducibility of SUDA samples, increased the area of the IFAS alpha spectrometer sensor from 1.2 cm to 3.1 cm, and improved source positioning within the IFAS. This paper will report on this optimization work, its impacts on IFAS performance, and future plans for IFAS miniaturization, improvements, and testing.

Chichester, David↗

In-Field Alpha Spectrometer Development FY2022 Mid-Year Report

In response to needs identified by the International Atomic Energy Agency (IAEA), Idaho National Laboratory (INL) has developed an In-Field Alpha Spectrometer (IFAS) to allow IAEA safeguards inspectors to collect samples of uranium hexafluoride (UF 6 ) at processing facilities, to perform field assessments to verify uranium enrichment. For sample collection, the IFAS method uses Single-Use Destructive Assay (SUDA) samplers, developed at Pacific Northwest National Laboratory (PNNL), which contain thin zeolite coatings that trap UF6 gas and convert it to the safer, more stable form uranyl fluoride (as a dihydrate, UO 2 F 2 ·2H 2 O). For alpha spectrometry, the IFAS instrument employs a large area silicon semiconductor transducer to detect and record alpha particle energy-deposition events. Over the course of this project INL, PNNL, Oak Ridge National Laboratory worked to optimize the SUDA sample design for alpha spectrometry, to optimize processes for manufacturing, loading, and shipping SUDA samples, and to allow the measurement of loaded SUDA samples. In fiscal year (FY) 2022 INL has bene investigating the reproducibility and measurement precision of IFAS measurements and the associated determination of uranium enrichment.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Optimization and Commercialization of the Juvenile Eel/Lamprey Acoustic Transmitter and Micro-battery (CRADA 477)

Through collaboration with partners under this CRADA, we continued to optimize the Eel/Lamprey Acoustic Transmitter (ELAT) of the Juvenile Salmon Acoustic Telemetry System (JSATS) to enhance its capability to track sensitive species and early life stages of fish with 3D and sub-meter accuracy. The transmitter firmware was improved to offer new functionalities, and the circuit design was revised to provide significantly more accurate frequency transmission. The transmitter's transducer was replaced with a shorter, more energy-efficient model. Additionally, the manufacturing processes for the transmitter and the microbattery used in it were improved. The outcomes of this work help advance understanding of migration timing and behaviors, habitat use, and survival rates of these species, supporting more informed management decisions for new and existing hydroelectric facilities and better designs for new hydropower systems that minimize or avoid environmental impacts.

13 HYDRO ENERGY↗

Mutually Reinforced Polymer–Graphene Bilayer Membranes for Energy‐Efficient Acoustic Transduction

Abstract Graphene holds promise for thin, ultralightweight, and high‐performance nanoelectromechanical transducers. However, graphene‐only devices are limited in size due to fatigue and fracture of suspended graphene membranes. Here, a lightweight, flexible, transparent, and conductive bilayer composite of polyetherimide and single‐layer graphene is prepared and suspended on the centimeter scale with an unprecedentedly high aspect ratio of 10 5 . The coupling of the two components leads to mutual reinforcement and creates an ultrastrong membrane that supports 30 000 times its own weight. Upon electromechanical actuation, the membrane pushes a massive amount of air and generates high‐quality acoustic sound. The energy efficiency is ≈ 10–100 times better than state‐of‐the‐art electrodynamic speakers. The bilayer membrane's combined properties of electrical conductivity, mechanical strength, optical transparency, thermal stability, and chemical resistance will promote applications in electronics, mechanics, and optics.

Khan, Assad U.↗

Systems and methods for monitoring organisms within an aquatic environment

Systems and methods for monitoring organisms within an aquatic environment are described. According to one aspect, an injectable acoustic transmission device includes a body configured to be injected inside of an organism, a transducer within the body and configured to convert a plurality of electrical signals into a plurality of data transmissions which are transmitted externally of the body and the organism, a plurality of circuit components within the body and configured to use electrical energy from a power source to generate the electrical signals which are provided to the transducer, and wherein the transducer defines an internal volume and at least one of the circuit components is provided within the internal volume of the transducer.

Deng, Z. Daniel↗

Self-powered Through-wall communication for dry cask storage monitoring

Many nuclear facilities, such as spent fuel storage dry casks and nuclear reactor pressure vessels, are entirely sealed by metal layers to prevent harmful radiation. For safety and security operations, the temperature, pressure, radiation, and humidity inside the vessel needs to be closely monitored. However, no practical technology is currently available to realize the through-wall data communication and monitoring for these vessels due to the inside harsh environment of high temperature and nuclear radiation. In this paper, an innovative self-powered wireless through-wall data communication system for the nuclear environment is presented, which demonstrates a successful solution to such challenges. The presented system is composed of four modules, i.e., energy harvester with power management circuits, ultrasound wireless communication using high-temperature piezoelectric transducers, electronic circuits for sensing and data transmission, and radiation shielding for electronics. Here, constitutive functions of each module were firstly designed and followed by the system integration. Experiments were conducted subsequently to validate the designed functions and evaluate the performance of the integrated system. Results showed that the average power of over 40 mW was harvested from the thermal flow inside the nuclear spent fuel canisters which could provide enough energy to operate the sensing and data communication systems. The gamma radiation test results showed that the thermoelectric energy harvester and ultrasound transceivers can withstand radiation dosing over 100 Mrad. Furthermore, temperature shock tests demonstrated that the entire system including the shielded electronics can survive and maintain their functionalities at temperatures as high as 195°C. Under the in-lab mocked-up high temperature conditions and radiation shielding, the proposed system is foreseen to survive and operate stably for fifty years inside a nuclear spent fuel canister, and send the frequency modulated data out of the canister for 3 s in every 10 min.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electric field stimulates production of highly conductive microbial OmcZ nanowires

Multifunctional living materials are attractive due to their powerful ability to self-repair and replicate. However, most natural materials lack electronic functionality. Here we show that an electric field, applied to electricity-producing Geobacter sulfurreducens biofilms, stimulates production of cytochrome OmcZ nanowires with 1,000-fold higher conductivity (30 S cm -1 ) and threefold higher stiffness (1.5 GPa) than the cytochrome OmcS nanowires that are important in natural environments. Using chemical imaging-based multimodal nanospectroscopy, we correlate protein structure with function and observe pH-induced conformational switching to β-sheets in individual nanowires, which increases their stiffness and conductivity by 100-fold due to enhanced π-stacking of heme groups; this was further confirmed by computational modeling and bulk spectroscopic studies. These nanowires can transduce mechanical and chemical stimuli into electrical signals to perform sensing, synthesis and energy production. Overall, these findings of biologically produced, highly conductive protein nanowires may help to guide the development of seamless, bidirectional interfaces between biological and electronic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Out-of-Pile Testing and Instrumentation Transient Water Irradiation System

Current initiatives to increase the burnup of conventional nuclear fuels past the approximate 62 GWd/t limit have been spurred on by direct savings to refueling and waste storage. The technical justification for a new license limit requires extensive qualification through experimental testing. Unlike beginning-of-life fuels, high-burnup fuels are more susceptible to fuel fragmentation, relocation, and dispersal (FFRD), therefore more data is needed to characterize fuels under key accident scenarios. The Transient Reactor Test Facility (TREAT) located at the Idaho National Laboratory has developed a testing apparatus architecture to test fuels and claddings at prototypic conditions. The Transient Water Irradiation System (TWIST) is the latest iteration of a testing device capable of conducting loss of coolant accidents (LOCAs) in TREAT. The Out-of-Pile Testing and Instrumentation TWIST (OPTI-TWIST) is an electrically heated device that is analogous to TWIST. OPTI-TWIST allows for detailed instrumentation and thermal-hydraulic characterization. TWIST ultimately aims to conduct the most advanced in-situ diagnostics to evaluate FFRD in a prototypic LOCA. Moreover, it will explore the phenomenological bifurcation of a decay-energy heat up driven LOCA and a stored-energy heat up driven LOCA. The instrumentation suite includes conventional thermocouples and pressure transducers in addition to an electro impedance sensor, an acoustic emission sensor, an optical pressure sensor, and an optical pyrometer. Characterizing these instruments in OPTI-TWIST eliminates complications of irradiation effects while preserving extreme thermal-hydraulic conditions. Finally, benchmarking both devices to a thermal-hydraulic code like the Reactor Excursion and Leak Analysis Program (RELAP)5-3D provides a unique opportunity for iteration. Pre-test predictions and post-test interpretations inform the physical designs, operational procedures, test conditions, and instrumentation types and positions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Utah FORGE: Pump and Probe Test on an Intact Westerly Granite Sample

This dataset contains results from a pump and probe experiment conducted on an intact Westerly Granite sample with a diameter of 1 inch and a height of 1 3/8 inches. The experiment was performed within an aluminum triaxial pressure vessel (TEMCO) to investigate the non-linear acoustic parameters of the sample under varying axial pressures. The confining pressure was maintained at 4 MPa, while the axial pressure was incrementally increased from 1 MPa to 17 MPa before being reduced back to 1 MPa. 5 dynamic pressure oscillations of 0.5 MPa were applied over a 10 minute interval. The dataset includes pump controller data, linear variable differential transformer (LVDT) measurements, and acoustic data. The pump controller data tracks the confining and axial pressures, flow rates, and pump volumes. LVDT measurements provide detailed records of the axial displacement of the cell piston. Additionally, acoustic data captured by s-wave transducers is archived in a compressed file.

15 GEOTHERMAL ENERGY↗

Compact and efficient elastocaloric heat pumps—Is there a path forward?

Elastocaloric cooling holds promise for energy-efficient heat pumping near room temperature with low environmental impact. Its adoption is, however, impeded by disproportionally large sizes of actuators compared with the active material volume. Taking magnetocaloric cooling as the baseline, the value of no more than 10:1 actuator volume to active material volume should lead to both size- and cost-effective solutions that may potentially be competitive with vapor-compression devices. With the goal to establish performance metrics that can lead to informed actuator selection for specific regenerator requirements, we analyze a wide range of elastocaloric materials and actuator technologies to find the best matches. We find that actuation with magnetic shape memory alloys meets all requirements; however, this technology is currently in early developmental stages and such actuators are not widely commercially available. Another promising and easily accessible option is standard rotary electric motors in combination with rotary-to-linear transduction mechanisms. A theoretical analysis of two case studies of elastocaloric systems using rotary electric motors with a Scotch yoke mechanism demonstrates the usefulness of our approach. Actuator requirements are based on two different regenerator configurations: one starting from zero strain without any mechanical energy recovery and another with 2% pre-strain and mechanical energy recovery to reduce the power and torque required from the motor. Our results indicate that the 10:1 target actuator to active material volume ratio can be met and feasibly lowered further, demonstrating that the proposed method for selecting actuators makes compact and efficient elastocaloric systems possible.

42 ENGINEERING↗

Utah FORGE: Pump and Probe Test on a Mated Fracture Westerly Granite Sample

This dataset contains results from a pump and probe experiment conducted on a mated fracture Westerly Granite sample with a diameter of 1 inch and a height of 2 7/8 inches. The experiment was performed within an aluminum triaxial pressure vessel (TEMCO) to investigate the non-linear acoustic parameters of the sample under varying axial pressures. The confining pressure was maintained at 4 MPa, while the axial pressure was incrementally reduced from 17 MPa to 1 MPa in 1 MPa steps. 5 dynamic pressure oscillations of 0.5 MPa were applied over a 10 minute interval. The dataset includes pump controller data, linear variable differential transformer (LVDT) measurements, and acoustic data. The pump controller data tracks the confining and axial pressures, flow rates, and pump volumes. LVDT measurements provide detailed records of the axial displacement of the cell piston. Additionally, acoustic data captured by s-wave transducers is archived in a compressed file.

15 GEOTHERMAL ENERGY↗

Ultrasonic Transducer Irradiation Test Results

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 . A multi-National Laboratory collaboration funded by the Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET ASI) program also provided initial support for this effort. This irradiation, which started in February 2014, is an instrumented lead test and real-time transducer performance data are collected along with temperature and neutron and gamma flux data. The irradiation is ongoing and will continue to approximately mid-2015. To date, very encouraging results have been attained as several transducers continue to operate under irradiation.

Daw, Joshua↗

Effect of sintering temperature on adhesion of spray-on piezoelectric transducers

Conventionally sol-gel spray-on transducers require a high-temperature (> 700 ◦C) sintering process; however, this process can affect the microstructure of the substrate material. For mechanical elbows and valves utilized for fluid transport in the energy sector, the components are designed to have a specific microstructure, and deviations from these specifications can create weak points in the system. For this reason it is important to investigate how the temperature of the deposition process affects the substrate. This paper investigates the effect of high-temperature and low-temperature (< 150 ◦C) processing conditions on the surface composition of the substrate. Furthermore, the resultant transducers from high- and low-temperature fabrication processes are compared to determine if a low-temperature processing method is feasible. For these studies a sol-gel spray-on process is employed to deposit piezoelectric ceramics onto a stainless-steel 316L substrate. Energy-dispersive X-ray spectroscopy is utilized to determine the composition of the substrate surface before and after transducer deposition. Results indicate that the high-temperature processing conditions may alter the surface composition of the metal due to a diffusion of the metal into the ceramic, which results in a metal surface that is bonded to the ceramic. Furthermore, it is shown that low-temperature processing of spray-on transducers is a viable method for transducer fabrication where the resultant transducers meet the industry minimum requirement of 30 dB signalto-noise ratio. In parallel simulation calculations, finite-element method (FEM) studies were performed to model the adhesive strength of the low-temperature processed transducer to the substrate surface. Comparisons between the simulations and experiments suggest that the bond strength is much greater than the commercial gel bonds and closer to hardened epoxy glue bonds. These results indicate that spray-on transducers fabricated under lowtemperature processing conditions are a viable solution for leave-in-place monitoring of structures.

M. Sinding, Kyle↗

Localizing Low-Grade Heat Using Hybrid Photonic-Phononic Materials

Creating next-generation devices capable of transducing waste heat into useful work will require building blocks designed to direct low-grade thermal energy at length scales well below the diffraction limit. Characterizing thermally induced energy transfer at the nanoscale, however, is a formidable task due to the simultaneous demand of high spatial and spectral resolution at infrared energies. Leveraging recent advancements in electron energy loss (EEL) and gain (EEG) spectroscopy, we reveal that individual nanostructures can concentrate energy by the resonant thermal excitation of their photonic Fabry–Pérot modes. Specifically, we show that the spatially localized gain signal increases upon in situ heating. Finally, theoretical modeling elucidates the mechanism for these observations by showing that a Purcell enhancement in the local photonic density of states drives the increased rate of infrared energy transfer from the ambient environment to each nanostructure.

36 MATERIALS SCIENCE↗

Studying light–matter interactions and energy transfer at the nanoscale with a trapped–ion quantum computer

A grand challenge in materials sciences is to control energy transduction, transfer and dissipation at the nanoscale. Meeting this challenge requires progress in nanoscale fabrication and synthesis, but equally importantly, also progress in our understanding of how nanoscale structure influences these phenomena. Although detailed quantum mechanical models exist that capture the structure and physics of materials and molecular species, solving these models to calculate the relevant emergent phenomena, which often occur over vastly different time and energy scales, has so far proven difficult. In this project, we studied how to model energy transfer and light-matter interactions using trapped-ion quantum computers. Our studies focused on emulation of critical processes in natural systems, such as the well-known photosynthetic pigment-protein complexes responsible for capturing and transducing light to electrons. In addition, we implemented proof-of-principle experiments demonstrating that such calculations are possible on trapped-ion quantum computing hardware. These studies and experiments pave the way to investigate energy transport and transduction in a detail not accessible with classical computing technologies. We expect that our studies will allow to extract important guiding principles on how to improve the efficiency of nano-scale light-harvesting and transduction devices.

36 MATERIALS SCIENCE↗

Flexible CO 2 Sensor Architecture with Selective Nitrogen Functionalities by One‐Step Laser‐Induced Conversion of Versatile Organic Ink

Abstract Nitrogen‐containing carbons (NC) are a class of sustainable materials for selective CO 2 adsorption. A versatile concept is introduced to fabricate flexible NC‐based sensor architectures for room‐temperature sensing of CO 2 in a one‐step laser conversion of primary films cast from abundant precursors. By the unidirectional energy impact in conjunction with depth‐dependent attenuation of the laser beam, a layered sensor heterostructure with a porous transducer and active sensor layer is formed. Comprehensive microscopic and spectroscopic cross‐sectional analyses confirm the preservation of the high content of imidazolic nitrogen in the sensor. The performance is optimized in terms of material morphology, chemical composition, and surface chemistry to achieve a linear relative resistive response of up to Δ R / R 0 = −14.3% (10% of CO 2 ). Thermodynamic analysis yields Δ ads H values of −35.6 and 34.1 kJ·mol −1 for H 2 O and CO 2 , respectively. The sensor is operable even in humid environments (e.g., ∆ R / R 0,RH = 80% = 0.53%) and shows good performance upon strong mechanical deformation.

flexible gas sensors↗