Search NASA⌕ Search

SEARCH · Search NASA

Results for “environmental chamber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The hygrothermal performance of continuous and cavity wood fiber insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Hygrothermal Performance of Continuous and Cavity Wood Fiber Insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Summary of Attached Inflatable Decelerator (AID) Development

Attached inflatable decelerators (AID) were tested in an environmental chamber, a spin tunnel, and a wind tunnel. Deployment tests were conducted in environmental chamber to examine guided and unguided water alcohol vapor inflation. Subsonic performance tests were conducted in the spin tunnel. The full-scale wind tunnel was used for AID gust and supersonic performance tests. The supersonic tests were conducted at Mach number 3.0 with 12 ounces of fluid and Mach number 2.2 with six ounces of fluid.

Source record↗

A Unique Facility For Metabolic and Thermoregulatory Studies

A unique exercise facility has been developed and used to perform tipper body ergometry tests for space applications. Originally designed to simulate the muscular, cardiovascular and thermoregulatory responses to working in zero gravity, this facility may be used to conduct basic thermoregulatory investigations applicable to multiple sclerosis patients. An environmental chamber houses the tipper body ergometer and permits control of temperature, air now and humidify. The chamber is a closed system and recirculate-s air after conditioning if. A Cybex Lipper body ergometer has been mounted horizontally on the wall of the environmental chamber. In this configuration, the subject lies underneath the arm crank on a supine seat in order to turn the crank. The supine seat can be removed in order to introduce other equipment into the chamber such as a stool to allow upright arm cranking, or a treadmill to allow walk-run experiments. Physiological and environmental signals are fed into a Strawberry Tree data acquisition system while being monitored and logged using the Workbench software program. Physiological monitoring capabilities include 3-lead EKG using an H-P patient monitor, 5 site skin temperature and core temperature using YSI thermistors, and O2 consumption and CO2 production using AMFTFK Applied Electrochemistry analyzers and sensors. This comprehensive data acquisition set tip allows for calculation of various thermoregulatory indices including heat storage, evaporative heat loss, latent heat loss, and metabolic rate. The current system is capable of adding more data acquisition channels if needed. Some potential studies that could be carried out using the facility include: 1) An investigation into the efficiency of cooling various segments of the body to lower Tc 1-2 F. 2) A series of heat and mass balance studies comparing various LCG configurations.

Williamson, Rebecca C.↗

Environmental fog/rain visual display system for aircraft simulators

An environmental fog/rain visual display system for aircraft simulators is described. The electronic elements of the system include a real time digital computer, a caligraphic color display which simulates landing lights of selective intensity, and a color television camera for producing a moving color display of the airport runway as depicted on a model terrain board. The mechanical simulation elements of the system include an environmental chamber which can produce natural fog, nonhomogeneous fog, rain and fog combined, or rain only. A pilot looking through the aircraft wind screen will look through the fog and/or rain generated in the environmental chamber onto a viewing screen with the simulated color image of the airport runway thereon, and observe a very real simulation of actual conditions of a runway as it would appear through actual fog and/or rain.

Chase, W. D.↗

Interpreting T-History Data on Supercooling and Phase Change Enthalpy of a Salt-Hydrogel Complex for Building Thermal Management

Phase change materials (PCMs) are promising materials for storing and discharging latent heat in buildings to regulate the thermal environment. Measurement of salt hydrate PCM thermal performance is often challenging because of supercooling and phase segregation. Though differential scanning calorimetry (DSC) has been widely used to measure thermal properties of various phase change materials, DSC uses milligrams of sample and is unrealistic for predicting large-scale materials performance. The T-history method [1], in contrast, handles higher volumes but the analysis typically requires a lumped capacitance assumption. Here, we report and analyze T-History data on a novel salt-hydrogel complex with high viscosity, that renders low Biot number sample preparation extremely challenging. We re-examine the standard T-history method and compared against DSC data in this complex material. We report details of an experimental setup, built with necessary additions to a controlled environmental chamber. We carefully examine the validity of the lumped capacitance assumption and suggest a modified analysis using a computational approach for reliable data. Experimental parameters such as ramp rate and temperature range of the environmental chamber are considered via computational modeling to understand the effect of ramp rate on supercooling [2]. Finally, we report thermal cycling experiments on the salt-hydrogel complex. Our modified approach to measuring supercooling and enthalpy of fusion at large scales is important in better understanding the performance of phase-change materials at scale for building thermal storage. References: [1] Marin, Jose M, Belen Zalba, Luisa F Cabeza, and Harald Mehling. “Determination of Enthalpy Temperature Curves of Phase Change Materials with the Temperature-History Method: Improvement to Temperature Dependent Properties.” Measurement Science and Technology 14, no. 2 (February 1, 2003): 184–89. https://doi.org/10.1088/0957-0233/14/2/305. [2] Safari, A., R. Saidur, F.A. Sulaiman, Yan Xu, and Joe Dong. “A Review on Supercooling of Phase Change Materials in Thermal Energy Storage Systems.” Renewable and Sustainable Energy Reviews 70 (April 2017): 905–19. https://doi.org/10.1016/j.rser.2016.11.272

thermodynamics↗

Evolvable Cryogenics (ECRYO) Pressure Transducer Calibration Test

This paper provides a summary of the findings of recent activities conducted by Marshall Space Flight Center's (MSFC) In-Space Propulsion Branch and MSFC's Metrology and Calibration Lab to assess the performance of current "state of the art" pressure transducers for use in long duration storage and transfer of cryogenic propellants. A brief historical narrative in this paper describes the Evolvable Cryogenics program and the relevance of these activities to the program. This paper also provides a review of three separate test activities performed throughout this effort, including: (1) the calibration of several pressure transducer designs in a liquid nitrogen cryogenic environmental chamber, (2) the calibration of a pressure transducer in a liquid helium Dewar, and (3) the calibration of several pressure transducers at temperatures ranging from 20 to 70 degrees Kelvin (K) using a "cryostat" environmental chamber. These three separate test activities allowed for study of the sensors along a temperature range from 4 to 300 K. The combined data shows that both the slope and intercept of the sensor's calibration curve vary as a function of temperature. This homogeneous function is contrary to the linearly decreasing relationship assumed at the start of this investigation. Consequently, the data demonstrates the need for lookup tables to change the slope and intercept used by any data acquisition system. This ultimately would allow for more accurate pressure measurements at the desired temperature range. This paper concludes with a review of a request for information (RFI) survey conducted amongst different suppliers to determine the availability of current "state of the art" flight-qualified pressure transducers. The survey identifies requirements that are most difficult for the suppliers to meet, most notably the capability to validate the sensor's performance at temperatures below 70 K.

Diaz, Carlos E., Jr.↗

Methods for In Situ Electroluminescence Imaging of Photovoltaic Modules Under Varying Environmental Conditions

Electroluminescence (EL) imaging is a powerful tool used to identify defects in photovoltaic solar cells. Typically, this type of characterization is performed in the dark using a current injection that equals short-circuit current measured at standard test conditions (STC). Restricting imaging to such a temperature range limits the information obtained about the module and cells. However, it is not trivial to develop a tool that would allow for EL imaging to be performed under a wider range of temperatures. Here we demonstrate an in situ EL imaging capability developed within an environmental chamber that allows for control of sample temperatures between –40 and 90 °C. Additionally, we demonstrate EL imaging of 4-cell mini-modules (MiMo) under front-side mechanical loading. A Raspberry Pi-connected camera with short-pass filter removed is used for EL imaging. The camera is low-cost with a small form-factor, appropriate for use in a harsh, enclosed environment. The camera is installed within a thermally isolating housing mounted within the environmental chamber. Three example cases are given for MiMos that exhibit various forms of degradation including solder fatigue and cell cracking. It is shown that by measuring at conditions above and below STC, different behaviors may be identified. In some cases, restricting characterization to STC may lead to a failure to detect damage existing in the sample.

14 SOLAR ENERGY↗

Long-term ultrasonic monitoring of concrete affected by alkali-silica reaction

This article presents continuous monitoring results of alkali-silica reaction (ASR) development in concrete specimens for over 400 days using ultrasonic testing and expansion measurements. Eight concrete specimens with nonreactive aggregate (Control), reactive coarse aggregate, and reactive fine aggregates were cast with two reinforced confinement conditions. The specimens were conditioned in an environmental chamber with high temperature and humidity (38°C and 90% relative humidity) to accelerate the ASR development. A multichannel ultrasonic monitoring system was developed to collect ultrasonic signals automatically, and the expansions in three directions were measured periodically. Results showed that the relative velocity change could detect the ASR initiation in all reactive specimens and show a correlation with expansion in the early stage. However, these correlations are inconsistent for different ASR specimens, and the velocity change becomes less sensitive to ASR damage in the late stage (after 300 days). Irrecoverable velocity drop was observed during every chamber shutdown period, especially in specimens with higher levels of ASR damage. This phenomenon suggests that the nonlinear ultrasonic response caused by the ambient temperature variation may indicate the ASR damage.

Engineering↗

Polarization Type Potential Induced Degradation under Positive Bias in a Commercial PERC Module: Preprint

Potential induced degradation of the polarization type (PID-p) can reduce module performance in a relatively short period of time. PID-p can occur at both voltage polarities, but most studies are focused on degradation under a negative bias. This paper uses commercial bifacial passivated emitter and rear contact (PERC) cells within a monofacial glass-backsheet module construction to evaluate the impact of PID-p under a positive bias on the front side. Using the aluminum-foil (Al-foil) method, the module was stressed for PID in an environmental chamber. After the stress, the maximum power (Pmax) showed a decline of 3.1% at 1000 W/m2 and 6.2% at 200 W/m2. Recovery under light was also investigated. Complete recovery was observed at high irradiance, while a partial recovery was seen at lower irradiance. The outcomes of this study can help in understanding PID-p degradation under a positive bias and its recovery under the light.

PERC↗

Dispersible Colloid Facilitated Release of Organic Carbon From Two Contrasting Riparian Sediments

In aqueous systems, including groundwater, nano-colloids (1–100 nm diameter) and small colloids (<450 nm diameter) provide a vast store of surfaces to which organic carbon (OC) can sorb, precluding its normal bioavailability. Because nanomaterials are ubiquitous and abundant throughout Earth systems, it is reasonable that they would play a significant role in biogeochemical cycles. As such, mineral nano-colloids (MNC) and small colloids, formed through mineral weathering and precipitation processes, are both an unaccounted-for reservoir and unquantified vector for transport of OC and nutrients and contaminants within watersheds. Water extractions and leaching experiments were conducted under (1) aerobic (ambient) and (2) anaerobic (environmental chamber) conditions for each of two contrasting riparian sediments from (1) Columbia River, Washington and (2) Tims Branch, South Carolina. Water dispersible colloid-adsorbed OC was as high as 48% of OC for Tims Branch anaerobic batch water extraction and as low as 0% for Columbia River aerobic batch water extractions. Anaerobic leaching from column experiments yielded higher colloid and OC release rates. Transmission electron microscopy with electron dispersive spectroscopy mapping revealed organic carbon associated with aggregations of nano-particulate silicate minerals and Mossbauer identified nano-particulate goethite. This exploratory study demonstrates that mineral facilitated release of OC in riparian sediments is both significant and variable between locations.

Rod, Kenton A.↗

An instrument for real time detection of contamination in space environmental tests chambers

An instrument for in situ vacuum detection of surface reflectance changes at 1216A was designed. Using successive reflections, this instrument is more sensitive as an indicator of reflectance changes than similar instruments having only a single reflection. The selection of each component of the instrument and its operational performance is discussed.

Richmond, R. G.↗

Environmental calibration chamber operations

Thermal vacuum capabilities are provided for the development, calibration, and functional operation checks of flight sensors, sources, and laboratory and field instruments. Two systems are available. The first is a 46 cm diameter diffusion pumped vacuum chambler of the bell jar variety. It has an internal thermal shroud, LN2 old trap, two viewing ports, and various electrical and fluid feedthroughs. The other, also an oil diffusion pumped system, consists of a 1.8 m diameter by 2.5 m long stainless steel vacuum tank, associated pumping and control equipment, a liquid nitrogen storage and transfer system and internal IR/visible calibration sources. This is a two story system with the chamber located on one floor and the pumping/cryogenic systems located on the floor below.

Lester, D. L.↗

Convert Ten Foot Environmental Test Chamber into an Ion Engine Test Chamber

The 10 Foot Space Simulator at the Jet Propulsion Laboratory has been used for the last 40 years to test numerous spacecraft, including the Ranger series, several Mariner class, among many others and finally, the Spirit and Opportunity Mars Rovers. The request was made to convert this facility to an Ion Engine test facility, with a possible long term life test. The Ion engine was to propel the Prometheus spacecraft to Jupiter's moons. This paper discusses the challenges that were met, both from a procedural and physical standpoint. The converted facility must operate unattended, support a 30 Kw Ion Engine, operate economically, and be easily converted back to former operation as a spacecraft test facility.

ion engines↗