Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Experimental Setup of Apodization Techniques for Beam Diagnostics Performed at ELBE

The ELBE (Electron Linac for beams with high Brilliance and low Emittance) facility in Dresden, Germany is a multipurpose user facility, which is also used for accelerator R&D purposes. The beam line was set up for transverse beam profile measurements, where the imaging system includes a series of three apodizers and five circular apertures. During beam operations both of these were changed remotely through automated LabView routines. The bunch structure and charge were varied to collect a series of images that were acquired automatically, and then stored for later analysis. Over 12,000 images were captured and then analyzed using software written at Jefferson Lab that runs ImageJ as it's main image processing library.

Freeman, B.↗

Search for hybrid baryons with CLAS12 experimental setup

It is crucial to study the meson electroproduction in the kinematic region dominated by the formation of resonances. CLAS12 setup in Hall B at Jefferson Lab is particularly suitable for this task, since it is able to detect scattered electrons at low polar angles thanks to the Forward Tagger (FT) component. The process that we propose to study is ep → e'K + Λ, where the electron beam will be provided by the CEBAF accelerator with energies of 6.6, 8.8, and 11 GeV. This thesis work describes the setup and calibration of the FT calorimeter and the studies related to the search of hybrid baryons through the measurement of the K + Λ electroproduction cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Novel Experimental Setup for Rare Events Selection and Its Potential Application to Super-heavy Elements Search

The paper presents a novel instrumentation for rare events selection which was tested in our research of short lived super heavy elements production and detection. The instrumentation includes an active catcher multi elements system and dedicated electronics. The active catcher located in the forward hemisphere is composed of 63 scintillator detection modules. Reaction products of damped collisions between heavy ion projectiles and heavy target nuclei are implanted in the fast plastic scintillators of the active catcher modules. The acquisition system trigger delivered by logical branch of the electronics allows to record the reaction products which decay via the alpha particle emissions or spontaneous fission which take place between beam bursts. One microsecond wave form signal from FADCs contains information on heavy implanted nucleus as well as its decays.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation and thermal analysis of production solenoid for Mu2e experimental setup

The Muon-to-Electron (Mu2e) experiment at Fermilab, will seek the evidence of direct muon to electron conversion at the sensitivity level where it cannot be explained by the Standard Model. An 8-GeV 25-kW proton beam will be directed onto a tilted gold target inside a large-bore superconducting Production Solenoid (PS) with the peak field on the axis of {approx}5T. The negative muons resulting from the pion decay will be captured in the PS aperture and directed by an S-shaped Transport Solenoid towards the stopping target inside the Detector Solenoid. In order for the superconducting magnets to operate reliably and with a sufficient safety margin, the peak neutron flux entering the coils must be reduced by 3 orders of magnitude that is achieved by means of a sophisticated absorber placed in the magnet aperture. The proposed absorber, consisting of W- and Cu-based alloy parts, is optimized for the performance and cost. Results of MARS15 simulations of energy deposition and radiation are reported. The results of the PS magnet thermal analysis, coordinated with the coil cooling scheme, are reported as well for the selected absorber design.

43 PARTICLE ACCELERATORS↗

Implementation of an Experimental Setup Based on the Three-Omega Method for Thermal Conductivity Measurements of Molten Salts

Molten salt reactors (MSRs) are one of the most promising next-generation nuclear reactor designs which use molten salts as the fuel and coolant. To design, model, predict, license, and operate MSRs, the behavior of the fuel and coolant must be understood as a function of temperature and irradiation, i.e., burnup. Of particular importance and complexity is the reliable and reproducible measurement of thermal conductivity of molten salts at high temperatures (> 500 °C). Thermal conductivity provides information on the rate at which heat passes through a specified material and is dependent on chemical composition. Currently, in the national laboratory complex, several methods for measuring thermal conductivity on molten salt systems are under development, however, to date, consistent data have not been produced. Typically, thermal conductivity measurements of high-temperature melts have been conducted by using the Transient Hot Wire (THW) method where thermal conductivity is determined by the change in temperature over time at a certain distance from a heating wire. Another time-dependent technique is the laser flash method, commonly used for solid samples. Laser flash requires prior measurements of density and heat capacity to calculate the thermal conductivity of the sample, introducing additional measurement errors. Steady state and time-dependent measurements such as THW and laser flash have errors from convection and ambient temperature fluctuations (heat radiation). In order to produce high fidelity thermal conductivity data, a measurement technique needs to be developed that will reduce the effect of convection at high temperatures by measuring in a very fast time window. In addition, to measure on actinide and irradiated salts the sample size should be small. Therefore, this project aims to develop a frequency-domain technique based on the three-omega (3?) method, previously proven to work on solids, nanofluids and low temperature solar salts (25 to 250 °C). If the 3?-device can be designed with materials that can withstand high temperatures (>500 °C) and can be configured to reduce errors due to convection, then it would prove to be a valuable technique for ensuring thermal conductivity on molten salt systems needed for MSR development. For this proposal, the 3? instrument will be designed, assembled, and tested on non-radioactive salts before being used on actinide bearing salts. In addition, a thermal model will be developed to determine the thermal conductivity of the sample from the measured thermal oscillation of the sensor. Because 3? is a direct method that requires a small volume of sample and works in a very fast time window, it will aid in suppressing the interference due to convection which is ideal when working with high temperature liquid samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Practical Insights on Applying Simulation-Based Control Methods in Experimental Studies

Advanced nuclear reactors are crucial to the future of energy both in the United States and around the globe. In contrast to the current operating fleet, they are characterized as being deployable in remote locations and able to operate in semi-autonomous or autonomous fashion. This leap forward necessitates a new reactor control paradigm. Because advanced nuclear reactors are still under development in the United States, the creation of new control methods to achieve autonomous operations has been based on systems modeling and simulation. However, an important factor in successfully deploying these new control methods is the ability to seamlessly transition from simulation environments to real-world settings. Control methods tested in both simulation and experimental settings need to be investigated in the context of advanced reactor applications. This work developed a series of simple controllers for Idaho National Laboratory (INL)’s Microreactor Applications Research Validation and Evaluation (MARVEL) microreactor operating in load-following scenarios. These controllers were tested in both simulation and experimental settings, and a comparative performance analysis was performed. The simulation tests leveraged the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software developed in a previous stage of the current effort, along with the MARVEL Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The experimental tests leveraged the COMMAND software, MARVEL models, and the U.S. Department of Energy Microreactor Program’s Microreactor Automated Control System (MACS). MACS was developed to serve as a control method testbed. It was customized to mirror the MARVEL microreactor, and COMMAND enabled MACS to emulate the physics of MARVEL. The load-following controller was developed using the simulation platform, with efforts to emulate real systems by introducing actuator saturation and noise. These factors were incrementally accounted for in the controller design. After finalizing the controller design, it was implemented with the experimental setup. The experimental conditions tested included an initial test under conditions similar to the final simulation test, and two additional scenarios. The first scenario introduced additional actuator saturation to account for equipment aging over time, which was unknown to the controller. The second scenario introduced sensor delay, a phenomenon anticipated with the use of remote operations or wireless communication in advanced reactors. These tests revealed several notable differences. While the controller performed well in simulation, it exhibited several limitations when transitioning to hardware. The main challenges involved maintaining the steady-state target power, as evidenced by larger error values between the true reactor power and setpoint power, as well as persistent oscillations in controlled reactor power. These issues could lead to unacceptable transient conditions in real reactor testing. Introducing actuator aging and stochastic delays in the experimental setup significantly impacted controller performance, resulting in increased overshoot and undershoot, and exacerbated error and oscillations previously mentioned. These findings underscore the importance of experimental testbeds for testing and validating control methods, as controllers developed using only theory and/or simulation may perform unexpectedly when applied to actual hardware. This research emphasizes the need for an experimental testbed for achieving such validation.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

New experimental methodology, setup and LabView program for accurate absolute thermoelectric power and electrical resistivity measurements between 25 and 1600 K: Application to pure copper, platinum, tungsten, and nickel at very high temperatures

In this paper we describe an experimental setup designed to measure simultaneously and very accurately the resistivity and the absolute thermoelectric power, also called absolute thermopower or absolute Seebeck coefficient, of solid and liquid conductors/semiconductors over a wide range of temperatures (room temperature to 1600 K in present work). A careful analysis of the existing experimental data allowed us to extend the absolute thermoelectric power scale of platinum to the range 0-1800 K with two new polynomial expressions. The experimental device is controlled by a LabView program. A detailed description of the accurate dynamic measurement methodology is given in this paper. We measure the absolute thermoelectric power and the electrical resistivity and deduce with a good accuracy the thermal conductivity using the relations between the three electronic transport coefficients, going beyond the classical Wiedemann-Franz law. We use this experimental setup and methodology to give new very accurate results for pure copper, platinum, and nickel especially at very high temperatures. But resistivity and absolute thermopower measurement can be more than an objective in itself. Resistivity characterizes the bulk of a material while absolute thermoelectric power characterizes the material at the point where the electrical contact is established with a couple of metallic elements (forming a thermocouple). In a forthcoming paper we will show that the measurement of resistivity and absolute thermoelectric power characterizes advantageously the (change of) phase, probably as well as DSC (if not better), since the change of phases can be easily followed during several hours/days at constant temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Modeling and Simulation Methods for Evaluation of Thermal Neutron Scattering Materials

With the rise of interest in thermal neutron scattering data for advanced reactor, criticality safety, and shielding applications, new experimental data are required for evaluation of new materials or for re-evaluation (or validations) of previously evaluated materials. New experimental data are evaluated in a three-step process: (1) computing the phonon characteristics, (2) computing the dynamic structure factor (DSF) from the data, and (3) using the experimental setup to simulate the experimental data. All three steps have challenges, ranging from the need for a sufficiently general material simulation code—a processing code that can compute the corresponding DSF—to having a detailed layout of the instrument/beamline/facility where the data were measured. Whereas phonon characteristics of materials can be computed using various methods (molecular dynamics, density functional theory, etc.), a high-fidelity computation of the DSF and the simulation of the experiment based on the DSF is vital to the accuracy of the evaluation. The latter two steps can be achieved by using the two corresponding code systems developed by instrument scientists at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory: (1) OCLIMAX, a program that calculates the dynamic structure factor from DFT and MD simulation results, and (2) MCViNE, a Monte Carlo neutron ray-tracing program designed to simulate neutron scattering experiments. Recently, polyethylene and yttrium hydride were measured at the Wide Angular-Range Chopper (ARCS) and SEQUOIA instrument stations of the SNS. These experiments are simulated using the density functional theory code, the Cambridge Serial Total Energy Package (CASTEP), to compute its phonon characteristics (eigenvalues/vectors and PDOS), which is then processed using OCLIMAX to yield the DSF, and finally the data at each instrument station are simulated by the MCViNE for comparison to the measured data for evaluation. For comparison to conventional evaluation methods, the scattering data processed from OCLIMAX are compared against those processed from the LEAPR module of NJOY, and the results from MCViNE simulations are compared against previously used simplified beamline models implemented in the Monte Carlo N-Particle (MCNP) code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Drive-pressure optimization in ramp-wave compression experiments through differential evolution

Ramp-wave dynamic-compression experiments are used to examine quasi-isentropic loading paths in materials. The gradual and continuous increase in pressure created by ramp waves make these types of experiments ideal for studying nonequilibrium material behavior, such as solidification kinetics. In ramp-wave compression experiments, the input drive pressure to the experimental setup may be exerted through one of a number of different mechanisms (e.g., magnetic fields, gas-gun-driven impactors, or high-energy lasers) and is generally required for simulating such experiments. Yet, regardless of the specific mechanism, this drive pressure cannot be measured directly (measurements are generally taken at a location near the back of the experimental setup through a transparent window), leading to an inverse problem where one must determine the drive pressure at the front of the experimental setup (i.e., the input) that corresponds to the particle velocity (the output) measured near the back of the experimental setup. Furthermore, we solve this inverse problem using a heuristic optimization algorithm, known as differential evolution, coupled with a multiphysics, hydrodynamics code that simulates the compression of the experimental setup. By running many rounds of forward simulations of the experimental setup, our optimization process iteratively searches for a drive pressure that is optimized to closely reproduce the experimentally measured particle velocity near the back of the experimental setup. While our optimization methodology requires a significant number of hydrodynamics simulations to be conducted, many of these can be performed in parallel, which greatly reduces the time cost of our methodology. One novel aspect of our method for determining the drive pressure is that it does not require physical modeling of the drive mechanism and can thus be broadly applied to many types of ramp-compression experiments, regardless of the drive mechanism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Recommendations for Linear Measurement Techniques on the Measurements of Nonlinear System Parameters of a Joint.

In the study of the dynamics of nonlinear systems, experimental measurements often convolute the response of the nonlinearity of interest and the effects of the experimental setup. To reduce the influence of the experimental setup on the deduction of the parameters of the nonlinearity, the response of a mechanical joint is investigated under various experimental setups. These experiments first focus on quantifying how support structures and measurement techniques affect the natural frequency and damping of a linear system. The results indicate that support structures created from bungees have negligible influence on the system in terms of frequency and damping ratio variations. The study then focuses on the effects of the excitation technique on the response for a linear system. The findings suggest that thinner stingers should not be used, because under the high force requirements the stinger bending modes are excited adding unwanted torsional coupling. The optimal configuration for testing the linear system is then applied to a nonlinear system in order to assess the robustness of the test configuration. Finally, recommendations are made for conducting experiments on nonlinear systems using conventional/linear testing techniques.

36 MATERIALS SCIENCE↗

A Novel Experimental Method for Measuring Coefficients of Restitution

A novel, experimental method is presented for measuring the coefficient of restitution during impact events. These measurements are used to indirectly validate a new model of elastic-plastic contact. The experimental setup consists of a stainless steel sphere that is attached at the bottom of a 2.2 m long pendulum. The test materials are of the form of 1 inch diameter pucks that the sphere strikes over a range of velocities. Digital image correlation is used to measure the displacement and velocity of the ball. From this data the coefficient of restitution is calculated as a function of velocity. This report details the experimental setup, experimental process, the results acquired, as well as the future work.

42 ENGINEERING↗

Robust COTS objective for diffraction-limited, high-NA, long front working distance imaging

We present a robust objective lens optimized for applications requiring both high numerical aperture (NA) and long front working distance imaging, comprised of all commercial-off-the-shelf (COTS) spherical singlet lenses. Unlike traditional designs that require separate collimation and refocusing stages, our approach directly converges imaged light to the back focal plane using a single lens group. Our configuration corrects spherical aberrations and efficiently collects light to achieve diffraction-limited performance across a wide range of wavelengths while simplifying alignment and assembly. Using this approach, we design and construct an example objective lens that features a long front working distance of 61 mm and a clipped NA of 0.30 (limited by an aperture in our experimental setup). We experimentally verify that it achieves monochromatic diffraction-limited resolution at wavelengths from 375 nm to 866 nm without requiring replacement of the lenses or changing the inter-lens spacings, and its performance remains robust across a 46 mm range variation in total length (by adjusting mainly the back working distance). Additionally, we develop a quantitative method to measure the field of view (FOV) using an experimentally calibrated pinhole target. Under 397 nm illumination (i.e., from 40 Ca + ion fluorescence), the objective achieves a resolution of 0.87 μm with a 540 μm FOV. This robust, all-COTS, and versatile design is well-suited for a broad range of experiments, supporting high-precision measurements and exploring quantum phenomena.

Cui, Jiafeng [Oak Ridge National Laboratory (ORNL)↗

Niowave Neutron Source Converter: Lead-Bismuth-Eutectic (LBE) Windowless Target Design and Evaluation

Los Alamos National Laboratory (LANL) is working with Niowave on the design and evaluation of their lead-bismuth-eutectic (LBE) windowless target (i.e., neutron source converter). Niowave plans to use 200 kW electron beam at 40 MeV beam energy to produce neutrons by photonuclear reaction with LBE. Then, the neutrons undergo fission at the surrounding uranium target assembly (UTA) to produce Molybdenum 99 (Mo-99) as a fission product, which eventually decays to Technetium-99 (Tc-99m). Tc-99m is one of important radioisotopes that is used for medical diagnostics. LANL conducted 3D multiphysics analysis for the Niowave neutron converter design and provided design assessment in thermohydraulic aspects. LANL conducted radiation transport calculations using Monte-Carlo N-Particle (MCNP) code with unstructured meshing scheme. The 3D volumetric heating profiles in the LBE and Stainless-Steel (SS) housing were imported into multiphase computational fluid dynamics (CFD) to obtain 3D temperature profiles of LBE and SS through conjugate heat transfer (CHT) analysis. The key findings are: LBE film thickness at the center of the beam is approximately 1.6 cm with a maximum LBE velocity of approximately 1.8 m/s, which is below a 2 m/s limit to avoid erosion issues on supporting structures; Heat deposition in the LBE peaks at ~1 cm depth from the LBE free-surface because of the forward interactions of electron, photon, and neutron with LBE; LBE maximum temperature is ~360 °C, which is below LBE evaporation initiative temperature, ~450 °C; LBE-SS interface temperature is ~350 °C, which is below the safety thermal limit to prevent severe corrosion on SS. The results indicate that Niowave’s neutron converter design satisfies both hydraulic and thermal criteria for safe operation. By virtue of such computational analysis, Niowave can move toward establishing an experimental setup to experimentally test their LBE neutron converter. The following sections describe the detailed work done by LANL.

43 PARTICLE ACCELERATORS↗