SEARCH · Search NASA
Results for “extraction chromatography”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Identification of novel microcystins in algal extracts by a liquid chromatography–high-resolution mass spectrometry data analysis pipeline
Not Available
The synergic effect of neutral organophosphorus ligands combined with acidic β-diketones for the extraction and separation of trivalent actinides
Investigating the extraction and separation behavior of americium and curium using synergic dual-ligand solvent extraction systems and their conversion to novel extraction chromatographic resins.
Chemical-Free Lithium Separation from High-Salinity Brines Using Model-Informed and Machine Learning-Optimized Multi-Column Zwitterionic Chromatography
Direct Lithium Extraction (DLE) technologies often struggle to produce high-purity lithium salts from high-salinity brines, as current approaches require chemical-based elution, regeneration, and precipitation steps, resulting in significant environmental footprints. A novel salt fractionation approach using carboxybetaine resin, known as zwitterionic chromatography (ZIC), has demonstrated that lithium ions can be separated from divalent cations under high-salinity conditions using only water as eluent, with no regeneration required. To enable continuous and scalable deployment of this approach, we developed a chemical-free Multi-column Zwitterionic Chromatography (MZC) process and its theoretical and process models. To predict and optimize this nontraditional separation system, we introduced a novel anti-Langmuir isotherm, and the isotherm parameters were estimated through a machine learning-driven optimization based on artificial neural network ensembles with numerical feasibility assessment. Using machine learning-driven optimization, the MZC process achieved 98.0% lithium recovery, 99.5 % Li/(Li + Mg + Ca) purity, a 31.3% productivity increase, and a 33% reduction in water use compared to batch operation. The proposed MZC process enables lithium separation at $0.6-1.2 kg-1 Li, with costs dominated by resin manufacturing, while offering lower separation costs and carbon footprint compared with conventional carbonation. Overall, these findings position the MZC process as an effective polishing step within scalable and sustainable lithium production pipelines.
Extraction of gold, mercury and lead on CL resin in HCl
The uptake behavior of 197 mHg, 194 Au and 212 Pb in HCl on CL resin (Triskem) was studied. The extraction of mercury and gold is high (D w > 5,000) at all concentrations of HCl, with a maximum extraction of gold at 4 M HCl (D w ~ 53,000) and maximum extraction of mercury at 0.01 M HCl (D w ~ 44,000). Lead has moderate uptake on CL resin (D w ~ 100) from lower concentrations of HCl (0.001 to 0.05 M) and no uptake on the resin in concentrations ≥ 0.4 M. The uptake kinetics are similar for all three isotopes with high weight distribution ratios (>1,000 for 197 mHg, 194 Au and > 100 for 212 Pb) in ~ 30 s and equilibrium established at ~ 5 min. A column study was performed to demonstrate that 197m Hg, 194 Au and 212 Pb could be retained on CL resin in dilute HCl and 212 Pb eluted in 1 M HCl with no detectable 197m Hg or 194 Au. Elution of 197 mHg and 194 Au was performed with concentrated HNO 3 , but with significant losses to the column, particularly for 194 Au.
Age determination of a 75 Se gamma radiography source for nuclear forensics
Here, two methods were used to evaluate the age of 75 Se sealed source material. Both methods utilized gamma spectroscopy to determine the quantity of parent 75 Se present, but they differed in the technique used to determine the quantity of daughter 75 As. In one method, 75 As was quantified using inductively coupled plasma-mass spectrometry (ICP-MS) after using chromatographic techniques to separate the parent and daughter isotopes. In the other method, total As was measured using optical emission spectroscopy (OES), which did not require separation prior to measurement. The OES method was faster and gave slightly lower uncertainties, but required more daughter material to be present because of higher concentration requirements, making it unsuitable for young material. Both methods are hampered by the monoisotopic nature of As, but still gave reasonable model ages that were in agreement with each other.
Extraction of gold, mercury, and lead with TEVA resin from HCl and HNO 3
The extraction behavior of 212 Pb, 197m Hg, and 194 Au on TEVA resin in HCl and HNO 3 solutions was studied with batch uptake, kinetics, and column studies. The uptake of mercury and gold was extremely high from HCl solutions, with maximum k’ >80,000 for both elements. The uptake of mercury was lower in HNO3 than HCl with a maximum k’ of ~ 8,000 in 0.02 M HNO 3 and decreasing uptake at higher concentrations of HNO3, which agrees well with previous work. The batch uptake of gold in HNO 3 was not measured, as it had been reported previously. The uptake of lead on TEVA resin in HCl was low with a maximum k’ of only ~ 90 in 1 M HCl. The uptake of lead in HNO 3 was negligible. The uptake kinetics of gold and mercury were characterized in HCl and HNO 3 solutions and high uptake was seen after ~ 60 s for both elements. Column separations of 212 Pb, 197m Hg, and 194 Au on TEVA resin from HCl and HNO 3 solutions are reported with high yields of mercury and lead, but with high losses of gold, which is retained on the resin. A rapid, high yield separation of 197m Hg from irradiated gold foils is presented with yields of ~ 100% for both elements and a total separation time of < 2 h.
Extraction of radium and actinium with dibenzo-21-crown-7 resin and Rose Bengal
The extraction of 224 Ra and 228 Ac with dibenzo-21-crown-7 resin was studied in solutions with Rose Bengal and identical solutions without Rose Bengal (blanks) from pH 3 to 12. Batch studies demonstrated that actinium is extracted at high pH (> 10) from both solutions but with a significantly higher extraction from the Rose Bengal solutions (maximum extraction ~ 60,000) than the blank solutions (maximum extraction ~ 2,000). In the Rose Bengal solutions, there was a weak extraction of actinium at lower pH (4–10) as well. There was no uptake of radium from the blank solutions, and a weak extraction at all pH levels from the Rose Bengal solutions. Kinetics studies were performed for actinium only, as radium had no significant extraction. Two column studies are demonstrated for the separation of radium from actinium. These separations are moderately effective with ~ 78% of the actinium recovered with no detectable radium.
Radiochronometric analysis of an historic Cs-137 activity standard
In this work, a 137 Cs activity standard discovered during routine inventory was analyzed to determine its model age using radiochronometry. The aqueous activity standard was separated using an established separation method that employs commercially available Sr resin. The method was also tested against a nuclear forensics reference material developed specifically for benchmarking 137 Cs radiochronometry methods. Results of the analyses showed good agreement between the results and the certified values of the reference material. Analysis of the discovered activity standard were also in good agreement with the activity certification date, though uncertainty was higher due to natural Ba contaminating the sample and the stable 133 Cs used as a carrier during the standard’s production.
Extraction of selenium and arsenic with TOA-impregnated XAD-2 resin from HCl
Here the uptake of 75 Se and 73 As on trioctylamine-impregnated resin from HCl solutions was studied with batch uptake, kinetics, and column studies. Selenium-75 extracts well (D w ~ 900) at high HCl concentrations (≥ 10 M) with and no extraction of 73 As at any HCl concentration. The uptake kinetics were slow with low extraction (D w < 100) for time periods ≤ 15 min and no clear equilibrium achieved even after 24 h. Column studies were performed to characterize the separation of 75 Se and 73 As; 75Se is retained from conc. HCl while arsenic is eluted with high yields and high radiopurity.
Synergistic extraction of rare earth elements, actinium, americium, and barium with TTA and Pb resin from acetate buffer solutions
The uptake behavior of 88 Y, 140 Ba, 140 La, 141 Ce, 152 Eu, 228 Ac, and 241 Am was studied with batch uptake, kinetics and column studies in a synergistic extraction system with Pb resin and 2-thenoyltrifuoroacetone in acetate-ethanol solutions. The k' values are very high (>10,000) at near neutral pH (~5 to 6) for all of the radioisotopes studied. The kinetics are reasonably fast for column separations, though the uptake rate is dependent on the concentration of 2-thenoyltrifuoroacetone. Column studies were performed to demonstrate the separation of the trivalent actinides and lanthanides from barium and common fssion products ( 99 Mo, 103 Ru).
Uptake of arsenic and selenium on iron-doped Pb resin
We report the uptake of the radioisotopes 73 As and 75 Se was characterized on Fe 3+ -doped Pb resin (Eichrom Technologies) from pH 1 to 12. There is good uptake of arsenic and selenium over a wide pH range (~ 1 to 10) with a decrease only at high pH (~ 12). Column experiments were performed to demonstrate the separations of these elements from solutions with near neutral pH values (~ 6 to 8) with high yields and high radiopurity. These separations may be relevant for a wide variety of applications especially isotope harvesting research.
Extraction of 88 Y, 152 Eu, 228 Ac, 241 Am, and 244 Cm with 2-thenoyltrifluoroacetone (TTA) resin
In this report the behavior of 88 Y, 152 Eu, 228 Ac, 241 Am, and 244 Cm was studied with 2-thenoyltrifluoroacetone resin with batch uptake, kinetics and column studies. Studies were performed in acetate buffer solutions (pH ~ 2 to ~ 6) and there was high uptake of all isotopes, except 228 Ac, at pH > 4.5. The kinetics of uptake were reasonable, although slower for the actinides, and sufficient for column studies. The retention of 88 Y, 152 Eu, and 241 Am on the resin in column studies was demonstrated as well as a reasonable separation of these isotopes from 228 Ac.
Extraction and separation of rare earth elements using LN resins in hydrochloric acid
The separation of the rare earth elements is essential for numerous scientific applications but remains a significant challenge due to the nearly identical chemical properties of the adjacent lanthanide elements. Eichrom’s LN series of extraction chromatographic resins feature organophosphorus extractants and are widely used to achieve adjacent lanthanide separations. While extensive characterization of these resins has been completed for nitric acid matrices, the use of hydrochloric acid is preferred for a variety of applications. Further, the extraction of the rare earth elements, La–Lu and Y, has been characterized on LN and LN2 resins in hydrochloric acid via batch uptake and column chromatographic studies.
Extraction of americium, curium, and californium with LN resin from HCl and HNO 3
The uptake of 241 Am, 244 Cm and 249 Cf with LN resin was studied in HCl and HNO3 solutions with concentrations ranging from 0.02 to 2.5 M. There is high uptake at concentrations < 0.1 M in both acids for all three isotopes with decreasing uptake at higher concentrations and negligible extraction at ≥ 0.6 M. Californium has a higher extraction than americium and curium, which are extremely similar. Kinetics studies showed rapid uptake of all three isotopes. Here, column studies were performed to demonstrate the separation of 241 Am and 249 Cf, and a bulk separation including nine stable lanthanides along with 241 Am, 249 Cf, and 88 Y.
TALSPEAK-based separation of the trivalent actinides from rare earth elements using LN resin
The separation of 241 Am, 244 Cm and 249 Cf from rare earth elements using LN resin and lactate buffer solutions with diethylenetriaminepentaacetic acid is described with numerous columns studies. The elutions are based on TALSPEAK liquid–liquid extraction chemistry, and provide high yield (> 90%), rapid, simple separations of the trivalent actinides from the lanthanides, which is often challenging due to similarities in chemical behavior among the trivalent f-block elements. Further, all three actinides can be separated from rare earth elements, including from massless fission product samples and samples with small amounts (~ 1–5 mg) of stable lanthanides. Separations with no detectable overlap between the actinide and lanthanide elutions is possible with massless samples, and in samples with mass high separation factors can be achieved (Am/Eu: 171; Am/La: 10 6 ).
Separation of radium and actinium in acetic acid/acetate solutions using TK101 resin
Here, the uptake and elution behavior of Ra and Ac was studied on TK101 resin using acetic acid and acetate buffer (acetic acid/lithium acetate) solutions. There is high extraction of Ra (>10 3 ) over a wide range of acetic acid concentrations (0.02 to 4 M) with slightly lower extraction (>10 2 ) in the acetate buffer solutions (pH 3.9 to 5.6). The Ac extraction is considerably lower with a maximum D w of ∼100, and negligible extraction at high acetic acid concentrations (> 1 M) and in the acetate buffer solutions. The difference in D w can be leveraged for highly efficient separations of Ac from Ra, with no detectable Ra in the Ac fractions and high Ac yields (∼100%). These separations may be useful for radiopharmaceutical applications as the Ac purity is extremely high and the elution conditions can be optimized to be biologically safe and appropriate for chelation to molecules relevant to targeted alpha therapy.