Cleanroom Garment Silicone Contamination

The slide presentation reviews actions taken at Goddard Space Flight Center (GSFC) to eliminate contamination by silicone in clean rooms. Background information includes facilities and hardware affected by silicon contamination, a discussion of the negative aspects of silicone contamination, clean room garments, and how the problem was identified at GSFC. Actions taken by the GSFC Contamination Engineering Group and lessons learned are detailed. Results include: awareness of the silicone issue in laundry, increase in infrastructure and support of the testing lab, establishment of protocols for garment verification, closer relationship established with laundry and converter, specifications for laundry services and garments were strengthened, all consumables are tested before use in clean rooms, and established procedures were used to identify and treat silicone found on face masks.

Geer, Wayne↗

Pressure Sensitive Tape in the Manufacture of Reusable Solid Rocket Motors

ATK Launch Systems Inc. manufactures the reusable solid rocket motor (RSRM) for NASA's Space Shuttle program. They are used in pairs to launch the Space Shuttle. Pressure sensitive tape (PST) is used throughout the RSRM manufacturing process. A few PST functions are: 1) Secure labels; 2) Provide security seals; and 3) Protect tooling and flight hardware during various inert and live operations. Some of the PSTs used are: Cloth, Paper, Reinforced Teflon, Double face, Masking, and Vinyl. Factors given consideration for determining the type of tape to be used are: 1) Ability to hold fast; 2) Ability to release easily; 3) Ability to endure abuse; 4) Strength; and 5) Absence of adhesive residue after removal.

Champneys, Jeff↗

Phase change thermal control materials, method and apparatus

An apparatus and method for metabolic cooling and insulation of a user in a cold environment. In its preferred embodiment the apparatus is a highly flexible composite material having a flexible matrix containing a phase change thermal storage material. The apparatus can be made to heat or cool the body or to act as a thermal buffer to protect the wearer from changing environmental conditions. The apparatus may also include an external thermal insulation layer and/or an internal thermal control layer to regulate the rate of heat exchange between the composite and the skin of the wearer. Other embodiments of the apparatus also provide 1) a path for evaporation or direct absorption of perspiration from the skin of the wearer for improved comfort and thermal control, 2) heat conductive pathways within the material for thermal equalization, 3) surface treatments for improved absorption or rejection of heat by the material, and 4) means for quickly regenerating the thermal storage capacity for reuse of the material. Applications of the composite materials are also described which take advantage of the composite's thermal characteristics. The examples described include a diver's wet suit, ski boot liners, thermal socks, gloves and a face mask for cold weather activities, and a metabolic heating or cooling blanket useful for treating hypothermia or fever patients in a medical setting and therapeutic heating or cooling orthopedic joint supports.

Buckley, Theresa M.↗

Flexible composite material with phase change thermal storage

A highly flexible composite material having a flexible matrix containing a phase change thermal storage material. The composite material can be made to heat or cool the body or to act as a thermal buffer to protect the wearer from changing environmental conditions. The composite may also include an external thermal insulation layer and/or an internal thermal control layer to regulate the rate of heat exchange between the composite and the skin of the wearer. Other embodiments of the PCM composite also provide 1) a path for evaporation or direct absorption of perspiration from the skin of the wearer for improved comfort and thermal control, 2) heat conductive pathways within the material for thermal equalization, 3) surface treatments for improved absorption or rejection of heat by the material, and 4) means for quickly regenerating the thermal storage capacity for reuse of the material. Applications of the composite materials are also described which take advantage of the composite's thermal characteristics. The examples described include a diver's wet suit, ski boot liners, thermal socks, gloves and a face mask for cold weather activities, and a metabolic heating or cooling blanket useful for treating hypothermia or fever patients in a medical setting and therapeutic heating or cooling orthopedic joint supports.

Buckley, Theresa M.↗

Flexible composite material with phase change thermal storage

A highly flexible composite material having a flexible matrix containing a phase change thermal storage material. The composite material can be made to heat or cool the body or to act as a thermal buffer to protect the wearer from changing environmental conditions. The composite may also include an external thermal insulation layer and/or an internal thermal control layer to regulate the rate of heat exchange between the composite and the skin of the wearer. Other embodiments of the PCM composite also provide 1) a path for evaporation or direct absorption of perspiration from the skin of the wearer for improved comfort and thermal control, 2) heat conductive pathways within the material for thermal equalization, 3) surface treatments for improved absorption or rejection of heat by the material, and 4) means for quickly regenerating the thermal storage capacity for reuse of the material. Applications of the composite materials are also described which take advantage of the composite's thermal characteristics. The examples described include a diver's wet suit, ski boot liners, thermal socks, ,gloves and a face mask for cold weather activities, and a metabolic heating or cooling blanket useful for treating hypothermia or fever patients in a medical setting and therapeutic heating or cooling orthopedic joint supports.

Buckley, Theresa M.↗

Phase change material thermal capacitor clothing

An apparatus and method for metabolic cooling and insulation of a user in a cold environment. In its preferred embodiment the apparatus is a highly flexible composite material having a flexible matrix containing a phase change thermal storage material. The apparatus can be made to heat or cool the body or to act as a thermal buffer to protect the wearer from changing environmental conditions. The apparatus may also include an external thermal insulation layer and/or an internal thermal control layer to regulate the rate of heat exchange between the composite and the skin of the wearer. Other embodiments of the apparatus also provide 1) a path for evaporation or direct absorption of perspiration from the skin of the wearer for improved comfort and thermal control, 2) heat conductive pathways within the material for thermal equalization, 3) surface treatments for improved absorption or rejection of heat by the material, and 4) means for quickly regenerating the thermal storage capacity for reuse of the material. Applications of the composite materials are also described which take advantage of the composite's thermal characteristics. The examples described include a diver's wet suit, ski boot liners, thermal socks, gloves and a face mask for cold weather activities, and a metabolic heating or cooling blanket useful for treating hypothermia or fever patients in a medical setting and therapeutic heating or cooling orthopedic joint supports.

Buckley, Theresa M.↗

A physician’s working group guides COVID-19 prevention in a mission critical environment

Background A team was assembled at the National Aeronautics and Space Administration’s (NASA) Johnson Space Center (JSC) to help navigate the shifting COVID-19 pandemic. Their goal was to mitigate the impact of COVID on astronauts, other essential personnel, and the human spaceflight program. This team supplemented the JSC Pandemic Incident Response Group, whose function is to set policy for the overall management of JSC’s COVID-19 mitigations for all onsite mission-essential and mission-critical activities, including health policy. Context The first mission to return to Earth from the International Space Station at the start of the pandemic returned when there was limited information about the transmission and prevention of COVID-19. The medical leadership at JSC determined that a dedicated team was required to navigate the uncharted waters of the pandemic. Description of Activities Issues tackled by this panel included: prevention of COVID-19 transmission during altitude, dive, and spacecraft training – activities that require prolonged close contact between multiple individuals who often cannot safely wear face masks; mitigating the risks of domestic and international travel for essential personnel; securing COVID-19 testing from local and foreign hospital systems; acquiring antigen and PCR analyzers for in-house testing; and the development of quarantine policies for crewed spacecraft launches and landings in Kazakhstan and the United States. The panel also provides clinical return-to-work guidance for cases of COVID-19 in essential personnel.

covid↗

Evaluation of an Additively Manufactured Respirator for Personnel Protection from Particulates

Additively manufactured respirators (AMRs) made using rigid plastic can be fitted with repurposed filter media to yield a wearable mask capable of passing a quantitative fit test with criteria set for commercial, N95 health care particulate respirators. This has been verified through an evaluation study assessing AMR masks fabricated using open-source design files and a commercial fused-filament fabrication machine, using N95 filter cloth and a P100 respirator cartridge. A few examples of filter media not designed for human respiratory protection were also evaluated in an AMR mask but did not demonstrate filtering sufficient to pass the N95 test criteria. All attributes of an AMR mask system must be considered during design and when testing performance, including the mask frame, gasket, and the cord used to secure the mask to the face. AMR masks are not the same as commercially available respiratory masks. If AMR masks are used as personal protective equipment (PPE) during a crisis when there is a shortage of regular PPE it is important that wearers are fully informed of the differences, tradeoffs, and risks associated with their use. Quantitative fit testing and proper training on how to don and doff the AMR mask are important to help achieve the best possible outcome when they are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reinforced Masks for Ion Plating of Solar Cells

Proposed mask for ion plating of surface electrodes on silicon solar cells reinforced to hold shape better during handling. Fabrication process for improved mask similar to conventional mask. Additional cuts and bends made in wide diametral strip to form bridges between pairs of mask fingers facing each other across this strip. Bridges high enough not to act as masks so entire strip area plated.

Conley, W. R.↗

Domestic Supply Chain of Medical Consumables Needed During COVID-19 Pandemic

This report is an assessment of the availability, demand, and production capability of medical consumables needed to combat the COVID-19 pandemic. We focus here on the ability of the supply chain to increase production to meet demand during peak pandemic conditions. In addition, we report on domestic production efforts and supply chain issues, as well as the propensity of other countries to limit export of needed medical supplies to the United States. In brief, the domestic supply chain and production capability vary greatly depending on the consumable. Some consumables, such as N95 masks or face shields, can likely be nearly fully supplied by domestic production, while other consumables, such as gloves or surgical masks, have little domestic production and thus will depend on imports to meet demand. The assessment pulls primarily from published news sources and company press releases. As such, the demand and production numbers are not precisely known, and some degree of uncertainty exists in them. The total production capability is also often difficult to ascertain from these reports especially as other industries have begun to supplement existing supply chains. In addition, local conditions (including company financial decisions, local public health issues, and political aspects) can vary throughout the pandemic which will affect future production. The report also pulls from estimates of demand and domestic production of some consumables compiled by the White House COVID-19 Supply Chain Taskforce (SCTF) presented by Rear Admiral John Polowczyk before a June 9, 2020 hearing of the Senate Homeland Security and Governmental Affairs Committee. These numbers, where applicable, are likely to be more accurate than those found in public news sources since they are more directly tied to private companies’ actual orders and actual production estimates, as opposed to publicly released estimates. Finally, we note that other issues with the supply chain, including the production of raw materials, increase demand due to industries that have not previously used PPE now using it, and increased domestic production from non-traditional suppliers, make complete picture of a rapidly changing supply chain difficult to obtain. This report attempts to produce an accurate image of the supply and estimated demand, as understood by the authors who are not experts in the medical supply chain.

42 ENGINEERING↗

Characterization of Materials Used as Face Coverings for Respiratory Protection

Use of masks is a primary tool to prevent the spread of the novel COVID-19 virus resulting from unintentional close contact with infected individuals. However, detailed characterization of the chemical properties and physical structure of common mask materials is lacking in the current literature. In this study, a series of commercial masks and potential mask materials, including 3M Particulate Respirator 8210 N95, a material provided by Oak Ridge National Laboratory Carbon Fiber Technology Facility (ORNL/CFTF), and a Filti Face Mask Material, were characterized by a suite of techniques, including scanning electron microscopy, X-ray diffraction, Raman spectroscopy, and X-ray photoelectron spectroscopy. Wetting properties of the mask materials were quantified by measurements of contact angle with a saliva substitute. Mask pass-through experiments were performed using a dispersed metal oxide nanoparticle suspension to model the SARS-CoV-2 virus, with quantification via spatially resolved X-ray fluorescence mapping. Notably, all mask materials tested provided a strong barrier against respiratory droplet breakthrough. The comparisons and characterizations provided in this study provide useful information when evaluating mask materials for respiratory protection.

36 MATERIALS SCIENCE↗

Underwater Virtual Reality System for Neutral Buoyancy Training: Development and Evaluation

During terrestrial activities, sensation of pressure on the skin and tension in muscles and joints provides information about how the body is oriented relative to gravity and how the body is moving relative to the surrounding environment. In contrast, in aquatic environments when suspended in a state of neutral buoyancy, the weight of the body and limbs is offloaded, rendering these cues uninformative. It is not yet known how this altered sensory environment impacts virtual reality experiences. To investigate this question, we converted a full-face SCUBA mask into an underwater head-mounted display and developed software to simulate jetpack locomotion outside the International Space Station. Our goal was to emulate conditions experienced by astronauts during training at NASA's Neutral Buoyancy Lab. A user study was conducted to evaluate both sickness and presence when using virtual reality in this altered sensory environment. We observed an increase in nausea related symptoms underwater, but we cannot conclude that this is due to VR use. Other measures of sickness and presence underwater were comparable to measures taken above water. We conclude with suggestions for improved underwater VR systems and improved methods for evaluation of these systems based on our experience.

Simulation↗

Shadow masks predictions in SPARC tokamak plasma-facing components using HEAT code and machine learning methods

Here, this work uses machine learning (ML) to complement HEAT (Heat flux Engineering Analysis Toolkit) by developing 3-D footprint surrogate models for fast and accurate heat load calculations in the divertor of the SPARC tokamak. The focus is on shadowed regions, or magnetic shadows, caused by the 3-D geometry of plasma-facing components (PFCs). ML classifiers are employed to create a surrogate model for HEAT generated shadow masks, predicting these shadow masks and divertor heat flux profiles based on a diverse range of equilibria and only the plasma current, safety factor(q95) at the edge, and magnetic flux angles as input parameters. The ultimate goal is to integrate the model for real-time control and future operational decisions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Uncertainty analysis of Resource Demand Model for Covid-19

As part of the Department of Energy response to the novel coronavirus pandemic of 2020, a modeling effort was sponsored by the DOE Office of Science. One task of this modeling effort at Sandia was to develop a model to predict medical resource needs given various patient arrival scenarios. Resources needed include personnel resources (nurses, ICU nurses, physicians, respiratory therapists), fixed resources (regular or ICU beds and ventilators), and consumable resources (masks, gowns, gloves, face shields, sedatives). This report documents the uncertainty analysis that was performed on the resource model. The uncertainty analysis involved sampling 26 input parameters to the model. The sampling was performed conditional on the patient arrival streams that also were inputs to the model. These patient arrival streams were derived from various epidemiology models and had a significant effect on the projected resource needs. In this report, we document the sampling approach, the parameter ranges used, and the computational workflow necessary to perform large-scale uncertainty studies for every county and state in the United States.

59 BASIC BIOLOGICAL SCIENCES↗

Applicability for MELCOR Accident Code System (MACCS) to Model the Atmospheric Transport of Biological Contaminants

Characterization of airborne transmission behavior for biological contaminants is a critical aspect in developing public health guidelines in the event of an outbreak. Guidelines such as safe separation distances and physical protections (mask and face-shields) are heavily influenced by the particular biological airborne transmission risk, which depends on a multitude of factors and is not easily or readily determined, therefore potentially lagging behind the time sensitive need to inform effective public health guidelines. Herein is proposed a means to leverage the substantial investment over the last three decades of the Nuclear Regulatory Commission in the MACCS code suite developed at Sandia National Laboratories. This work includes augmenting the MACCS code to represent biological rather than radioactive contaminants in the atmosphere, therefore characterizing the airborne transmission risk for such contaminants and helping to inform critical and time sensitive public health guidelines.

54 ENVIRONMENTAL SCIENCES↗

Simplified deflection-coil linearity testing

Mask placed over face of image-dissecting photomultiplier tube has precision array of pinholes that permit light to impinge on tube at known points. Signals are fed to deflection coil which sweeps beam across each point without complex operator procedures.

Kramer, G. P.↗

International Space Station (ISS) Emergency Mask (EM) Development

The Emergency Mask (EM) is considered a secondary response emergency Personal Protective Equipment (PPE) designed to provide respiratory protection to the International Space Station (ISS) crewmembers in response to a post-fire event or ammonia leak. The EM is planned to be delivered to ISS in 2012 to replace the current air purifying respirator (APR) onboard ISS called the Ammonia Respirator (AR). The EM is a one ]size ]fits ]all model designed to fit any size crewmember, unlike the APR on ISS, and uses either two Fire Cartridges (FCs) or two Commercial Off-the-Shelf (COTS) 3M(Trademark). Ammonia Cartridges (ACs) to provide the crew with a minimum of 8 hours of respiratory protection with appropriate cartridge swap ]out. The EM is designed for a single exposure event, for either post ]fire or ammonia, and is a passive device that cannot help crewmembers who cannot breathe on their own. The EM fs primary and only seal is around the wearer fs neck to prevent a crewmember from inhaling contaminants. During the development of the ISS Emergency Mask, several design challenges were faced that focused around manufacturing a leak free mask. The description of those challenges are broadly discussed but focuses on one key design challenge area: bonding EPDM gasket material to Gore(Registered Trademark) fabric hood.

Toon, Katherine P.↗