Approaches for effective negative pressure isolation space control to minimize airborne transmission of contaminants in residential homes

Controlling airborne transmission of contaminants including respired viruses such as SARS-CoV-2 is necessary to protect occupants living in the same house with a contagious person. The effectiveness of interventions requiring minor efforts that create a negative pressure isolation zone (IZ) for a contagious person has yet to be systematically tested for residential homes. In this study, ASHRAE Standard 170, which offers guidance for negative pressure isolation space control in healthcare facilities, was used in developing practical and attainable recommendations for residential single-family homes. The relative effectiveness of several control strategies was evaluated through experimentally conducting 17 different test cases in a manufactured single-family house laboratory. These cases were designed based on various heating, ventilation and air-conditioning (HVAC) operating scenarios, intervention measures including closing the IZ door and/or sealing over supply and return air grilles in the IZ, and utilization of bathroom exhaust or portable window fans for pressure control. Four out of 17 test cases were identified as having the potential for strong containment with adequate depressurization in the IZ. The most effective IZ depressurization was achieved through continuously operating the exhaust fan in the bathroom attached to the IZ, by installing a portable window fan that extracted air out of the IZ, and a portable room air conditioner with the AC unit exhaust duct installed in one of the IZ windows.

Construction & Building Technology↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transients following the loss of detonation confinement

We present a theory for the evolution of a one-dimensional, steady-state detonation reaction zone to a two-dimensional reaction zone, when the explosive experiences a sudden loss of side-on confinement as a boundary of the explosive is impulsively withdrawn. Our focus is on condensed-phase explosives, which we describe as having a constant adiabatic gamma equation of state and an irreversible, state-independent reaction rate. We consider two detonation models: (i) the instantaneous reaction heat release Chapman–Jouguet (CJ)-limit and (ii) the spatially resolved reaction heat-release Zel’dovich–von Neumann–Döring (ZND) model, in the limit where only a small fraction of the energy release is resolved (the SRHR-limit). Two competing rarefaction waves are generated by this loss of confinement: (i) a smooth wave coming off the full length of the withdrawn boundary and (ii) a singular fan spreading out from the point where the detonation shock and the withdrawn boundary meet. For the CJ-limit, in all cases the singular rarefaction fan eventually dominates the competition to control the steady-state behaviour. For the SRHR-limit, the spatially resolved heat release moderates this competition. When the withdrawal speed is fast, the rarefaction fan dominates; when the withdrawal speed is slower, the smooth rarefaction eventually dominates, although the flow features a fan at early times. By examining the mathematical properties of the steady two-dimensional fan-based solution, we set down a mechanism for this transition in behaviours.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cybersecurity impact of the growth of data in sports

As the sporting industry continues to increase dependence on new and often massive data sets, they also risk exposing themselves, as well as the leagues, teams, venues, players, and fans, to risks posed by not protecting the confidentiality and integrity of this data. The industry, especially true for professional sports, demands an ever increasing supply of new forms of data to achieve their goals of enticing new fans; enhancing experience; expanding the fan experience from venues and television to the internet and mobile devices; measuring and evaluating the performance and safety of players; and increasing revenue. New methods have emerged to collect data about a variety of aspects of sports ranging from players to fans to teams to venues. Data collected during sporting events is combined with historical data to also help teams analyze and predict performance. To synthesize these predictive analytical and historical memories, sports teams and organizations mix a variety of computer technologies. System integration tends to focus on ensuring the availability of the data and reliability of the technologies but might introduce risks to the confidentiality (privacy) and integrity of the data. Recognizing the potential risks requires review and evaluation. Much of the data is collected for publicly providing information to the fans, so threats to confidentiality pose fewer risks. The greatest risk is violating the privacy of players, such a private performance test, or using technology to gain a competitive advantage.

Jenkins, Stephanie↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) HEPA Filtration System - 20165

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous High Efficiency Particulate Air (HEPA) filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The integrated system design provides for reducing the salt, clay and diesel particulates from the exhaust airflow from the mine, prior to full filtration using Nuclear Safety Significant HEPA filters. The SSCVS design and equipment provides for continuous HEPA filtration over a wide range of operating and environmental conditions. The new exhaust system connects to the existing underground exhaust shaft, and the exhaust air flows from the underground through Salt Reduction Units (SRUs) to protect the final filter banks from excessive moisture and rapid salt/dust buildup. Each of the six (6) SRUs consists of a demister to remove entrained moisture, a dry salt remover unit to filter approximately 90% of the entrained salt/dust, and an automated water treatment system to periodically clean the demisters and to remove salt from the SRU filters. At the maximum expected exhaust flowrate of 540,000 Cubic Feet per Minute (CFM) / 255 Cubic Meters per Second (m{sup 3}/s), five (5) salt removal units will be in operation with one unit in standby or maintenance. An in-line variable frequency drive booster fan will offset pressure losses through each SRU and reduce the relative humidity of the air exiting the SRUs. In the event of a high radiation alarm from the underground Continuous Air Monitors (CAMs), the SRUs will be automatically bypassed, which places the SRS and building outside of the Safety Significant confinement boundary. From the SRUs, the exhaust is directed to the HEPA filter banks located in the New Filter Building. The exhaust system is designed to provide continuous HEPA filtration prior to release to the exhaust stack. There are 22 HEPA filter banks rated at 27,000 CFM / 12.75 m{sup 3}/s each. Each filter bank has two stages of pre-filters and two stages of HEPA filters. The filtered air from each of the 22 filter banks discharges into a common concrete plenum, which is maintained under a negative pressure by the main exhaust fans. Six 1,000 HP variable frequency drive exhaust fans are provided on the south side of the plenum. At the maximum expected exhaust flow of 540,000 CFM, four exhaust fans and twenty filter banks will be in operation. The fans discharge vertically to a separate concrete exhaust plenum. The filtered exhaust is routed from the exhaust plenum to a 125-foot-tall exhaust stack via a 13-foot diameter duct. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tracking Aerosol Convection Interactions Experiment (TRACER) Field Campaign Report

Convective clouds serve a critical role in the Earth’s energy and water cycles through their transport of heat, moisture, momentum, and chemical species through the troposphere driving the global circulation (e.g., Hartmann et al. 1984, Del Genio et al. 2012, Su et al. 2014). On more local scales, convective clouds impact the atmospheric heating profile through diabatic heating effects, removal of water from the atmospheric column through precipitation, and conditioning of the local environment impacting further development of clouds (e.g., Sullivan and Voigt 2021). These critical roles underscore the importance of realistic representation of convective processes across scales of models from large-eddy simulation (LES), to convection-permitting models (CPM; e.g., Kendon et al. 2020, Marinescu et al. 2021), to numerical weather prediction (NWP) models used for operational weather forecasting, to Earth system models used to predict climate sensitivity (Sanderson et al. 2011, Sherwood et al. 2014, Tomassini et al. 2014, Zhao et al. 2016, Cronin et al. 2017). A key component of improving model representation of convective clouds is better quantification and parameterization of updraft microphysics and dynamics, including their interactions with the surrounding environment and storm organization (Bony et al. 2015, Hagos and Houze 2016, Donner et al. 2016, Morrison et al. 2020). Aerosol is an important environmental factor that could affect convective clouds and precipitation since cloud droplet and ice formation processes are initiated by it. Andrae et al. (2004) hypothesized that aerosols associated with increased biomass burning particles acting as cloud condensation nuclei (CCN) result in smaller and more monodisperse cloud droplets leading to suppression of warm rain formation, ultimately leading to more cloud water being lofted above the freezing level based on observations in the Amazon region. The subsequent increase in latent heat release increases the buoyancy of rising convective parcels invigorating the deep convection. This work was followed by a description of the theoretical basis for this “cold-phase invigoration” by Rosenfeld et al. (2008), who argued that it could have a significant effect for deep convective clouds with warm cloud-bases. Several modeling studies (e.g., Khain et al. 2005, 2009, van den Heever et al. 2006, Fan et al. 2007, 2009, 2012, Lee et al. 2008, Storer et al. 2010, Lebo et al. 2012, Storer and van den Heever 2013, Chen et al. 2020, Dagan et al. 2022) have investigated these aerosol-convection interactions and the environmental factors that influence their relative importance and magnitude. More recently, several studies have indicated that “warm-phase invigoration”, the enhancement of convection through condensational heating, also appears to play a role in enhancing both shallow cumuli (Seiki and Nakajima 2014, Saleeby et al 2015) and deeper tropical convection (Lebo and Seinfeld 2011, Khain et al. 2012, Sheffield et al 2015, Fan et al. 2018, Igel and van den Heever 2021), as well as Houston thunderstorms (Fan et al. 2007, 2020). However, still other studies have provided additional evidence of systematic biases in simulated convective outflow ice size distribution properties, which are consistent with a lack of poorly understood secondary ice production within convective updrafts (e.g., Fridlind et al. 2017). To help address these critical gaps in our understanding of cloud processes, aerosol processes and aerosol-cloud interactions, the Tracking Aerosol Convection Interactions Experiment was designed building upon efforts by the Aerosol, Cloud, Precipitation and Climate (ACPC) Initiative (http://acpcintiative.org/), a joint effort of the International Geosphere-Biosphere Programme (IGBP) and the World Climate Research Program (WCRP) that focused on resolving uncertainties in the interactions between aerosol and clouds towards better understanding the role that these interactions play in the climate system. The TRACER campaign was motivated by recommendations from a number of pilot studies undertaken by ACPC (van den Heever et al. 2017, Fridlind et al. 2019, Hu et al. 2019, Fan et al. 2020, Marinescu et al. 2021, Hernandez-Deckers et al. 2022) that pointed towards the southeastern Texas region as a locale where aerosol-convection interactions could be studied owing to the copious occurrence of isolated convection during the summer months accompanied by diverse and significant sources of aerosols from both anthropogenic and natural sources. The TRACER campaign began on 01 October 2021 and extended through 30 September 2022 with an intensive operational period (IOP) during June-September 2022. Three main sites (Table 1) were managed by the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of nonlinear control performance of air handling units under variable operation conditions using root distribution approach

The control systems at Air handling units (AHUs) have nonlinear nature, resulting potentially in sluggish, aggressive, or oscillatory responses under variable operation conditions. This paper is to develop an approach for evaluating the nonlinear control performance of AHUs under variable operation conditions and for identifying the impact of varying multiple operation parameters which guides controller design. To do so, an operation parameter-based root distribution technique, intended to sketch the paths traced by closed-loop poles as multiple operation parameters are varied, is first introduced. The technique—which may be viewed as an extension of conventional, single-variable root locus—is then applied to a fan speed control system that includes a motor with a variable frequency drive and a supply fan with an air duct under variable fan speed and duct static pressure. Using the technique, the system’s stability region is graphically identified. The system is also found to be aggressive and gradually lose its stability as the fan speed decreases and the duct static pressure increases, which is validated by the field tests. Here, the root distribution approach is an effective tool to evaluate the performance of any nonlinear control systems at AHUs with multiple variable operation parameters without requiring time-domain simulations.

42 ENGINEERING↗

Performance trade-offs in reconfigurable networks for HPC

Designing efficient interconnects to support high-bandwidth and low-latency communication is critical toward realizing high performance computing (HPC) and data center (DC) systems in the exascale era. At extreme computing scales, providing the requisite bandwidth through overprovisioning becomes impractical. These challenges have motivated studies exploring reconfigurable network architectures that can adapt to traffic patterns at runtime using optical circuit switching. Despite the plethora of proposed architectures, surprisingly little is known about the relative performances and trade-offs among different reconfigurable network designs. We aim to bridge this gap by tackling two key issues in reconfigurable network design. First, we study how cost, power consumption, network performance, and scalability vary based on optical circuit switch (OCS) placement in the physical topology. Specifically, we consider two classes of reconfigurable architectures: one that places OCSs between top-of-rack (ToR) switches—ToR-reconfigurable networks (TRNs)—and one that places OCSs between pods of racks—pod-reconfigurable networks (PRNs). Second, we tackle the effects of reconfiguration frequency on network performance. Our results, based on network simulations driven by real HPC and DC workloads, show that while TRNs are optimized for low fan-out communication patterns, they are less suited for carrying high fan-out workloads. PRNs exhibit better overall trade-off, capable of performing comparably to a fully non-blocking fat tree for low fan-out workloads, and significantly outperform TRNs for high fan-out communication patterns.

Teh, Min Yee↗

Quaternary slip rates and most recent surface rupture of the Bitterroot fault, western Montana

The Bitterroot fault is a ~100-km-long Quaternary active normal fault that bounds the eastern margin of the north–south-trending Bitterroot Mountains and accommodates extension near the Intermountain Seismic Belt. Here, new detailed mapping using high-resolution topographic data derived from light detection and ranging (lidar) along the southern Bitterroot Range documents multiple generations of fault scarps in Holocene–Pleistocene deposits with vertical off sets that increase in magnitude with age. Fault mapping indicates a complex fault geometry characterized by an en echelon pattern of discontinuous segments of 41–78° east-dipping normal faults that appear to cut the older Eocene detachment fault, and locally 70–88° west-dipping antithetic normal faults. 10 Be cosmogenic exposure dating provides in situ age control for 32 surface boulders (>1 m) sampled in glacial deposits. Near Como Dam, two Pinedale-age glacial moraine sequences yield peak age distributions of 15.0 ± 0.4 ka and 16.4 ± 0.6 ka as apparent exposure ages (e = 0), and 15.4 ± 0.4 ka and 16.8 ± 0.6 ka based on the maximum allowed boulder surface erosion rate (e = 2 mm/ka). Vertical separation of 3.5 ± 0.2 m across the ~16–17 ka glacial moraine off set by the Bitterroot fault scarp yields a fault slip rate of 0.2–0.3 mm/yr. Glacial Lake Missoula highstand shorelines, inset into the ~15 ka glacial moraine and vertically off set 4.6 ± 1.6 m by an antithetic strand of the Bitterroot fault, yield fault slip rates of 0.2–0.5 mm/yr that overlap with fault slip rates on the main strand near Lake Como (0.2–0.3 mm/yr). At the Ward Creek fan located ~15 km to the north of Lake Como, two glacial debris fan sequences yield peak age distributions of 16.6 ± 0.4 ka and 62.8 ± 1.7 ka (e = 0), and 17.0 ± 0.4 ka and 69.9 ± 2.2 ka (e = 2 mm/ka). Vertical separations of 2.4 ± 0.3 m and 4.5 ± 0.2 m on the ~17 ka and ~63–70 ka fan surfaces off set by the Bitterroot fault yield fault slip rates of 0.2–0.3 mm/yr and 0.1 mm/yr, respectively. Our results indicate broadly consistent fault slip rates for the main fault segments at Lake Como (0.2–0.3 mm/yr) and the Ward Creek fan (0.1–0.3 mm/yr) with an along-strike range of 0.1–0.3 mm/yr for the southern Bitterroot fault. Fault scaling relations and evidence of multiple late Quaternary fault surface ruptures suggest the Bitterroot fault could produce a Mw ~7.2 earthquake. Structural model constraints and our slip rate results indicate both high-angle or low-angle fault geometries are possible at depth. A seismogenic low-angle fault model could generate a larger earthquake of Mw >7.2. Earthquake history is unknown for the Bitterroot fault, but fault scarps in young glacial deposits demonstrate its seismogenic potential. Data from this study suggest seismic hazards from the Bitterroot fault may pose a high level of risk to the Missoula metropolitan area, the State’s second most populous region, and major infrastructures across the Missoula and Bitterroot Valleys.

58 GEOSCIENCES↗

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

NLR HPC Eagle GPU Node Metrics

Ganglia node metrics and iLO (Integrated Lights Out) power data captured from six representative Eagle GPU nodes The Eagle HPC operated at NLR from 2019 through 2024. Eagle was a 2,000-node, 8-petaflop system. This dataset is a representative sample of metrics for 6 of the GPU nodes. Each GPU node contained 2 CPUs and 2 GPUs. Data provided in compressed CSV format. Ganglia and iLO Power Time Series Fields ts: Timestamp dv: Device / Node - Rack and Unit - r103u17 == r(ack)103u(nit)17 mt: Metric (only present for Ganglia) vl: Value - Value in watts for iLO power (instantaneous value at sampling time) or specified Ganglia metric below Ganglia Metrics Metric name -- Metric description -- Unit cpu_aidle -- Percent of time since boot idle CPU -- Percent cpu_idle -- Percent CPU idle -- Percent cpu_nice -- Percent CPU nice -- Percent cpu_speed -- Speed in MHz of CPU -- MHz cpu_user -- Percent CPU user -- Percent cpu_wio -- The percentage of CPU Wait I/O -- Percent gpu0_bar1_memory -- Used GPU bar1 memory -- MB gpu0_decoder_util -- GPU decoder utilization -- Percent gpu0_ecc_db_error -- Total ECC error counts for the GPU -- Number gpu0_encoder_util -- GPU encoder utilization -- Percent gpu0_fan -- Fan speed -- RPM gpu0_fb_memory -- Used GPU framebuffer memory -- MB gpu0_graphics_clock_report -- Current clock speeds for the device -- MHz gpu0_mem_total -- Memory total -- MB gpu0_mem_util -- Memory utilization -- Percent gpu0_power_usage_report -- Power usage report -- Watts gpu0_temp -- GPU 1 temperature -- Celsius gpu1_bar1_memory -- Used GPU bar1 memory -- MB gpu1_decoder_util -- GPU decoder utilization -- Percent gpu1_ecc_db_error -- Total ECC error counts for the GPU -- Number gpu1_encoder_util -- GPU encoder utilization -- Percent gpu1_fan -- Fan speed -- RPM gpu1_fb_memory -- Used GPU framebuffer memory -- MB gpu1_graphics_clock_report -- Current clock speeds for the GPU -- MHz gpu1_mem_total -- Memory total -- MB gpu1_mem_util -- Memory utilization -- MB gpu1_power_usage_report -- Power usage report -- Watts gpu1_temp -- GPU 1 temperature -- Celsius ipmi_cpu1_temp -- CPU 1 temperature -- Celsius ipmi_cpu2_temp -- CPU 2 temperature -- Celsius ipmi_inlet_ambient_temp -- Temperature measured at intake -- Celsius ipmi_vr_p1_temp -- CPU 1 voltage regulator temperature -- Celsius ipmi_vr_p2_temp -- CPU 2 voltage regulator temperature -- Celsius mem_buffers -- Amount of buffered memory -- Bytes mem_cached -- Amount of cached memory -- Bytes mem_free -- Amount of available memory -- Bytes mem_shared -- Amount of shared memory -- Bytes mem_total -- Amount of available memory -- Bytes

97 MATHEMATICS AND COMPUTING↗

Motor and drive arrangement for refrigeration system

A heat exchanger system includes a heat exchanger coil circulating a first heat transfer fluid therethrough, and a fan at least partially surrounded by the heat exchanger coil to urge a flow of air through the heat exchanger coil to dissipate thermal energy from the first heat transfer fluid. A brushless direct current fan motor is located the fan to urge rotation of the fan and an ancillary electrical component operably connected to the heat exchanger system and electrically isolated from the first heat transfer fluid.

Feng, Yinshan↗

Performance Assessment of High-Efficiency Refrigerated Display Cases With Low Global Warming Potential Refrigerants

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison, was to assess the energy performance of two high-efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290, GWP = 3), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513A (GWP = 573). Performance of these display cases was compared to a baseline fixture using HFC (R-134A, GWP = 1301) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores and small supermarkets. The high-efficiency cases were equipped with energy-efficient lighting, improved panel insulation, high-efficiency evaporator and condenser fan motors, and high-effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions (ASHRAE 2018). However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining equivalent target product temperature, the energy-efficient fixtures A (containing R-290, improved insulation, heat exchangers with a higher overall heat transfer coefficient (higher UA), and more efficient lighting and fan motors) and B (containing R-513A, improved fans, and higher UA-heat exchangers, and more efficient lighting and fan motors) consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134A refrigerant. The daily energy consumption of the R-290, R-513A, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗

Smart indoor air venting system

A venting system in accordance with the present disclosure includes a ventilation fan and one or more sensors coupled to the ventilation fan. The ventilation fan is positioned to vent air from an indoor environment. The sensors are positioned to monitor conditions in the indoor environment and selectively operate the ventilation fan to condition air in the indoor environment.

Moore, Mike↗

Refractory-based thermal energy storage for industrial process heat: one-dimensional modeling, control, and optimization

The variable and weather-dependent output of wind and solar power plants present a substantial challenge for planning and operating electricity-systems, particularly in the absence of cost-effective and dispatchable energy storage technologies. This study investigates a high-temperature, electrically heated, refractory-based thermal energy storage (RTES) system that stores electrical energy as sensible heat in dense ceramic bricks over the 950–1800 °C range. The stored heat can be discharged as a controlled hot-gas stream for industrial heating, fuel substitution in high-temperature processes, or electricity generation. The main novelty is a comprehensive modelling, control, mapping, and optimization framework that integrates one-dimensional transient gas–solid heat transfer, fan-assisted discharge, bypass-flow regulation, reheating logic, fan-power evaluation, insulation-loss assessment, and genetic-algorithm-based design optimization. The model uses feedback from outlet temperature and delivered power to regulate discharge, while a two-stage genetic algorithm optimizes brick-channel geometry, gas-flow operation, and multilayer insulation thicknesses. Storage capacities below 50 MWh and discharge powers of 5–30 MW are analyzed to evaluate hold time, thermal delivery, fan-power penalty, heat loss, state-of-charge evolution, and indicative capital cost. Results demonstrate that optimized and well-insulated refractory-based thermal energy storage units can provide stable, efficient, and repeatable heat delivery over multiple discharge cycles. The generated performance and cost maps support modular refractory thermal energy storage as a practical option for large-scale integration of wind and solar generation and for high-temperature industrial process heat.

25 ENERGY STORAGE↗