Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Using double pulse laser ablation in air to enhance the strength of laser-driven shocks

In the process of multi-pulse laser ablation, inter-pulse delay time, Δ t , is known to be an important parameter for maximizing ablation efficiency as well as impulse imparted to the target. In this work, using photon Doppler velocimetry, we show that for single pairs of colinear pulses (1064 nm, 8 ns, ∼ 60 J cm -2 per pulse) in air, the peak free surface velocity of the back surface of an aluminum target (125 µm thick) is increased, by a factor of nearly 3, when Δ t = 10 microseconds, compared with both pulses arriving simultaneously (Δ t = 0). Fast imaging of the ablation process suggests this enhancement is due to rarefaction of the contiguous air in the passage of the leading shock produced by ablation, which then in turn allows a larger fraction of the energy of the second pulse to reach the target surface. This interpretation is strengthened by additional experiments in which the two pulses do not overlap on the target surface, but the shock strength is nevertheless enhanced. Given a fixed energy budget this work suggests a prescription for maximizing laser-driven shock strength by judicious choice of inter-pulse delay.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Non-Equilibrium Plasma Interactions with Biomaterials, Biological Solutions and Tissues

Cold atmospheric pressure plasma discharges offer an abundant source of reactive oxygen and nitrogen species (RONS) at room temperature enabling unique interactions with biomaterials, biological solutions and tissues. These interactions particularly with living matter are presently an important intellectual frontier in plasma science with promising potential applications ranging from human health care to advanced biomaterial processing. Exciting case studies have been reported that illustrate the huge potential of cold atmospheric plasma technology in wound healing and cancer treatment. The interaction of plasma with conducting and dielectric biomaterials such as tissue strongly influences the plasma properties. In turn this changes the impact of the plasma on the biomaterial. Particularly in the case of living matter, liquid based solutions are ubiquitous which complicates interfacial processes. The lack of insight into the underlying mechanisms of the interaction of plasma with wounds and tumors is currently a bottleneck for the further development of the technology and gives rise to many interesting scientific questions. This project was focused on plasma properties and kinetics during plasma-biomaterial interactions. Both DC pulsed and RF driven atmospheric pressure plasma jets, extensively used by the plasma community were studied. The bio-interfaces included hydrogel as a tissue model, (saline) solutions, bacteria and virus. Plasma diagnostics used include Thomson scattering, Rayleigh scattering, Raman scattering, (two-photon absorption) laser induced fluorescence, optical emission spectroscopy, absorption spectroscopy, molecular beam mass spectrometry and fast imaging allowing to determine electron densities and temperatures, ionic species, reactive species including radicals, gas temperatures, gas composition, electric fields and solution components transferred to the gas phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D Tomography and Image Processing Using Fast Neutrons Final Report

This document is the final report for project OR16-ML-3DTomography-PD3Jb, “3D Tomography and Image Processing Using Fast Neutrons.” This project was motivated by the availability of three-dimensional (3D) tomographic neutron transmission and induced-reaction data following the development of associated-particle imaging (API) systems with two-dimensional (2D) or “area” neutron detectors such as the Advanced Portable Neutron Imaging System, which is capable of simultaneous measurement of transmission and induced-reaction neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Upgrade and characterization of the fast-channels of Imaging Neutral Particle Analyzers in the DIII-D tokamak

This publication presents the characterization of the recently upgraded fast (MHz) channels of the DIII-D Imaging Neutral Particle Analyzers. The new system allows for a phase space resolution of < 10 keV and < 10 cm. The main source of noise is due to the background radiation (neutrons and gammas) present in the diagnostic lab during experiments, which can hit the photomultipliers and generate large spikes in signal. Good linear correlations (r 2 > 0.9) are found between the average rate of noise spikes in the fast channels and the average neutron rate. Additional noise is caused by the scintillation of the optical fibers used to guide the signal to the acquisition system, which is induced by neutron and gamma impacts. A correlation factor r 2 > 0.6 between the baseline noise caused by this scintillation and the signals in the neutron diagnostic was found. Possible mitigation strategies, such as the use of shielding and filters, are discussed. These allow to reduce the noise spike rate by an order of magnitude and the noise baseline by a factor 4. Despite the noise, it is shown that the upgraded fast channels provide enough signal-to-noise ratio to observe coherent fluctuations of the energetic particle population.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multimodal photon and neutron imaging devices with fast event-by-event multisampling readout and optimized particle type discrimination

A particle imaging method for distinguishing between types of incident particles, such as neutrons, photons, and alphas, and improving the position resolution of particle imaging devices with matrix readout. The method includes high frequency multisampling readout electronics that provides the sequences of multiple measurements for each detected event, resulting in recorded detailed waveform information describing the signals. Such detailed information is used to approximate each signal waveform with a parameterized function in which the extracted parameter sets determine the type of the incident particle in an optimized fashion. The detailed event-by-event multisampling information for each signal readout channel in the matrix readout of the radiation imaging devices improves and optimizes the position resolution for variable shapes of the signals. Such devices can be used in mixed radiation fields, creating a new class of multimodal photon and neutron imagers.

Degtiarenko, Pavel V.↗

Fast Neutron Scintillator Screens for Neutron Imaging Using a Layered Polymer-Phosphor Architecture

Fast neutrons enable a nondestructive examination of dense, large, and highly attenuating samples due to their lower interaction probability compared to thermal neutrons. However, this also creates a challenge in fast neutron imaging, as the thicker sensors necessary to detect fast neutrons degrade an image’s spatial resolution due to scattering within the sensor and the indeterminate depth of interaction in the sensor. This work explores the advantages of a fast neutron imaging screen with a layered polymer-phosphor screen approach as opposed to a mixed polymer-phosphor screen typically used in fast neutron imaging. Proton recoil is the primary conversion mechanism for fast neutron imaging. Simulations showed that the recoil proton range of typical fast neutrons is approximately 200 µm, however, tests at Idaho National Laboratory revealed that the light output of these screens increased at much greater polymer thicknesses. The NECTAR fast neutron beamline at FRM II was used to test the imaging performance of layered fast neutron imaging screens. Distinguishing between the fast-neutron and γ-ray signals is a major challenge in fast neutron imaging because all fast neutron sources also produce γ-rays. A relative comparison between a control plate and the fast neutron screen was made to distinguish between a γ-ray and fast neutron signals. MCNP modeling quantified the γ-ray and fast neutron contributions to the images measured at NECTAR, which were approximately a 75% γ-ray image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗

The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. Here, the spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Deeper, Wider, Faster programme: exploring stellar flare activity with deep, fast cadenced DECam imaging via machine learning

ABSTRACT We present our 500 pc distance-limited study of stellar flares using the Dark Energy Camera as part of the Deeper, Wider, Faster programme. The data were collected via continuous 20-s cadence g-band imaging and we identify 19 914 sources with precise distances from Gaia DR2 within 12, ∼3 deg2, fields over a range of Galactic latitudes. An average of ∼74 min is spent on each field per visit. All light curves were accessed through a novel unsupervised machine learning techniques designed for anomaly detection. We identify 96 flare events occurring across 80 stars, the majority of which are M dwarfs. Integrated flare energies range from ∼1031–1037 erg, with a proportional relationship existing between increased flare energy with increased distance from the Galactic plane, representative of stellar age leading to declining yet more energetic flare events. In agreement with previous studies we observe an increase in flaring fraction from M0 to M6 spectral types. Furthermore, we find a decrease in the flaring fraction of stars as vertical distance from the galactic plane is increased, with a steep decline present around ∼100 pc. We find that $\sim 70{{\ \rm per\ cent}}$ of identified flares occur on short time-scales of <8 min. Finally, we present our associated flare rates, finding a volumetric rate of 2.9 ± 0.3 × 10−6 flares pc−3 h−1.

Webb, S.↗

Fast quantum ghost imaging with a single-photon-sensitive time-stamping camera

Quantum ghost imaging (QGI) leverages correlations between entangled photon pairs to reconstruct an image using light that has never physically interacted with an object. Despite extensive research interest, this technique has long been hindered by slow acquisition speeds, due to the use of raster-scanned detectors or the slow response of intensified cameras. Here, we utilize a single-photon-sensitive time-stamping camera to perform QGI at ultra-low-light levels with rapid data acquisition and processing times, achieving high-resolution and high-contrast images in under 1 min. Our work addresses the trade-off between image quality, optical power, data acquisition time, and data processing time in QGI, paving the way for practical applications in biomedical and quantum-secured imaging.

Mavian, Alex (ORCID:0000000279448830)↗

Neutron Transmission Imaging with a Portable D-T Neutron Generator

Fast-neutron transmission imaging provides complementary information to x-ray transmission imaging. While fast neutron imaging resolution is generally below x-ray imaging, 14-MeV neutrons have an advantage over portable x-ray systems. Neutrons have higher transmission through high-Z materials due to a more uniform attenuation as a function of material atomic number Z compared to X-rays, and can therefore image low-Z materials inside high-Z materials. As a result, portable neutron transmission imaging has many applications, including inspection of concrete and welds for corrosion in vehicles, bridges, and other infrastructure, measurement of material levels in containers, and inspection of suspicious packages. Fast-neutron imaging is also more practical for field use than thermal-neutron imaging due to the size and shielding requirements typical of thermal-imaging systems compared to the availability of small 14.1 MeV D-T neutron generators. However, there are limitations in portable fast-neutron imaging systems, including limited neutron output, limited light produced by neutron scintillators, and lower resolution due to neutron source spot size and 2-3 mm scintillator thickness. In addition, digital-panel dark-noise is roughly 100x higher than neutron scintillator light, and variations in noise across the panel and in time is comparable to the imaging signal. Here we discuss recent efforts in developing a portable fast-neutron radiography system, including an improved neutron scintillator, mitigation of panel noise, and new commercial portable D-T neutron generators. We also present MCNP efforts to model neutron imaging, including scintillator resolution and the effects of neutron scattering from the object and surrounding materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging high jitter, very fast phenomena: A remedy for shutter lag

Dielectric breakdown is an example of a natural phenomenon that occurs on very short time scales, making it incredibly difficult to capture optical images of the process. Event initiation jitter is one of the primary challenges, as even a microsecond of jitter time can cause the imaging attempt to fail. Initial attempts to capture images of dielectric breakdown using a gigahertz frame rate camera and an exploding bridge wire initiation were stymied by high initiation jitter. Subsequently, a novel optical delay line apparatus was developed in order to effectively circumvent the jitter and reliably image dielectric breakdown. Here, the design and performance of the optical delay line apparatus are presented. The optical delay line increased the image capture success rate from 25% to 94% while also permitting enhanced temporal resolution and has application in imaging other high-jitter, extremely fast phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolving the fast ion distribution from imaging neutral particle analyzer measurements

A recently developed imaging neutral particle analyzer (INPA) on the DIII-D tokamak (Du 2018 Nucl. Fusion 58 082006) enables fast ion velocity-space tomography of high fidelity at the interrogated phase space. To accomplish this, the spatial and energy depending fast ( E < 80 keV) neutral flux towards the INPA stripping foils is calculated with FIDASIM and a newly developed code INPASIM simulates the INPA instrumental response to this neutral flux. Included in INPASIM is the neutral-foil interaction, the Larmor orbit tracing between the foil and the phosphor, the phosphor response to the incident ion flux as well as camera focusing. Benefiting from heavy, localized velocity-space weights and excellent signal to noise, computed tomography using the Ridge regression method is able to successfully reconstruct fine-scale velocity-space structures produced by multiple neutral beams separated by as small as ~3 keV in tests. Applying the inversion method to a sawtooth crash event reveals a significant profile flattening of confined passing particles across q = 1 flux surface, as well as a redistribution of fast ions into the trapped orbits at the plasma edge close to the last closed flux surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel imaging technique for thermal neutrons using a fast optical camera

A novel imaging technique for thermal neutrons using a fast optical camera is presented. Thermal neutrons are reacted with 6 Lithium to produce a pair of 2.73 MeV tritium and 2.05 MeV alpha particles, which in turn interact in a thin layer of LYSO crystal scintillator to produce a localized flash of light. These photons are directed by a pair of lenses to a micro-channel plate intensifier, and its output is connected to the optical camera, TPX3CAM. The results from the camera are reconstructed through a custom algorithm. Various cutting parameters were found through data analysis to eliminate the background, and they were shown effective in matching the simulated rate of the neutron source. The system is fast with 40 ns decay time and allows free-space light collection, both vastly enhances flexibility of neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast time-resolved 2D imaging of laser-driven fast electron transport in solid density matter using an x-ray free electron laser

High-power, short-pulse laser-driven fast electrons can rapidly heat and ionize a high-density target before it hydrodynamically expands. The transport of such electrons within a solid target has been studied using two-dimensional (2D) imaging of electron-induced Kα radiation. However, it is currently limited to no or picosecond scale temporal resolutions. Here, we demonstrate femtosecond time-resolved 2D imaging of fast electron transport in a solid copper foil using the SACLA x-ray free electron laser (XFEL). An unfocused collimated x-ray beam produced transmission images with sub-micron and ~10 fs resolutions. The XFEL beam, tuned to its photon energy slightly above the Cu K-edge, enabled 2D imaging of transmission changes induced by electron isochoric heating. Time-resolved measurements obtained by varying the time delay between the x-ray probe and the optical laser show that the signature of the electron-heated region expands at ~25% of the speed of light in a picosecond duration. Time-integrated Cu Kα images support the electron energy and propagation distance observed with the transmission imaging. The x-ray near-edge transmission imaging with a tunable XFEL beam could be broadly applicable for imaging isochorically heated targets by laser-driven relativistic electrons, energetic protons, or an intense x-ray beam.

47 OTHER INSTRUMENTATION↗