Observing strategy for the SDSS-IV/MaNGA IFU galaxy survey

Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) is an integral-field spectroscopic survey that is one of three core programs in the fourth-generation Sloan Digital Sky Survey (SDSS-IV). MaNGA’s 17 pluggable optical fiber-bundle integral field units (IFUs) will observe a sample of 10,000 nearby galaxies distributed throughout the SDSS imaging footprint (focusing particularly on the North Galactic Cap). In each pointing these IFUs are deployed across a 3° field; they yield spectral coverage 3600−10300 Å at a typical resolution R ∼ 2000, and sample the sky with 2″ diameter fiber apertures with a total bundle fill factor of 56%. Observing over such a large field and range of wavelengths is particularly challenging for obtaining uniform and integral spatial coverage and resolution at all wavelengths and across each entire fiber array. Data quality is affected by the IFU construction technique, chromatic and field differential refraction, the adopted dithering strategy, and many other effects. We use numerical simulations to constrain the hardware design and observing strategy for the survey with the aim of ensuring consistent data quality that meets the survey science requirements while permitting maximum observational flexibility. We find that MaNGA science goals are best achieved with IFUs composed of a regular hexagonal grid of optical fibers with rms displacement of 5 μm or less from their nominal packing position; this goal is met by the MaNGA hardware, which achieves 3 μm rms fiber placement. We further show that MaNGA observations are best obtained in sets of three 15 minute exposures dithered along the vertices of a 1.44 arcsec equilateral triangle; these sets form the minimum observational unit, and are repeated as needed to achieve a combined signal-to-noise ratio of 5 Å{sup −1} per fiber in the r-band continuum at a surface brightness of 23 AB arcsec{sup −2}. In order to ensure uniform coverage and delivered image quality, we require that the exposures in a given set be obtained within a 60 minute interval of each other in hour angle, and that all exposures be obtained at airmass ≲1.2 (i.e., within 1–3 hr of transit depending on the declination of a given field).

79 ASTRONOMY AND ASTROPHYSICS↗

Vacuum Nuller Testbed Performance, Characterization and Null Control

The Visible Nulling Coronagraph (VNC) can detect and characterize exoplanets with filled, segmented and sparse aperture telescopes, thereby spanning the choice of future internal coronagraph exoplanet missions. NASA/Goddard Space Flight Center (GSFC) has developed a Vacuum Nuller Testbed (VNT) to advance this approach, and assess and advance technologies needed to realize a VNC as a flight instrument. The VNT is an ultra-stable testbed operating at 15 Hz in vacuum. It consists of a MachZehnder nulling interferometer; modified with a "W" configuration to accommodate a hexpacked MEMS based deformable mirror (DM), coherent fiber bundle and achromatic phase shifters. The 2-output channels are imaged with a vacuum photon counting camera and conventional camera. Error-sensing and feedback to DM and delay line with control algorithms are implemented in a real-time architecture. The inherent advantage of the VNC is that it is its own interferometer and directly controls its errors by exploiting images from bright and dark channels simultaneously. Conservation of energy requires the sum total of the photon counts be conserved independent of the VNC state. Thus sensing and control bandwidth is limited by the target stars throughput, with the net effect that the higher bandwidth offloads stressing stability tolerances within the telescope. We report our recent progress with the VNT towards achieving an incremental sequence of contrast milestones of 10(exp 8) , 10(exp 9) and 10(exp 10) respectively at inner working angles approaching 2A/D. Discussed will be the optics, lab results, technologies, and null control. Shown will be evidence that the milestones have been achieved.

Lyon, R. G.↗

Advanced technology optical telescopes IV; Proceedings of the Meeting, Tucson, AZ, Feb. 12-16, 1990. Parts 1 & 2

The present conference on the current status of large, advanced-technology optical telescope development and construction projects discusses topics on such factors as their novel optical system designs, the use of phased arrays, seeing and site performance factors, mirror fabrication and testing, pointing and tracking techniques, mirror thermal control, structural design strategies, mirror supports and coatings, and the control of segmented mirrors. Attention is given to the proposed implementation of the VLT Interferometer, the first diffraction-limited astronomical images with adaptive optics, a fiber-optic telescope using a large cross-section image-transmitting bundle, the design of wide-field arrays, Hartmann test data reductions, liquid mirrors, inertial drives for telescope pointing, temperature control of large honeycomb mirrors, evaporative coatings for very large telescope mirrors, and the W. M. Keck telescope's primary mirror active control system software.

Barr, Lawrence D.↗

Analysis of SOFCAL calibration data

Ionization calorimeters determine the total energy of a particle by absorbing, within the mass of the calorimeter, the entire energy of the particle or a significant (and determinable) fraction of it. The JACEE group has used passive ionization calorimetery, which employs photographic emulsions as the detector medium, to measure the charge composition and energy spectrum of cosmic rays up to, and exceeding, 10(exp 14)eV. The SOFIC approach depends similarly on the use of three-dimensional nuclear-electromagnetic shower theory to relate the ionization deposits obtained during a shower to the energy of the particle causing the shower. Bundles of thousands of scintillating optical fibers are read out using image-intensified CCD's. Such an event may be triggered by a fast shower detector placed under the instrument or if only heavy particles are of interest, from a fast primary Cerention detector placed above the calorimeter. In the first study, fast Hammatsu photomultiplier tubes were purchased and tested for possible application for a triggering purpose. In the second study, some refinements have been made to the theoretical treatment of hadronic interactions in the central collision region. These will be helpful in improving the simulations necessary for observations of high energy cosmic ray nuclei with a SOFIC.

Gregory, John C.↗

Bundle Networks: Fiber Bundles, Local Trivializations, and a Generative Approach to Exploring Many-to-one Maps

Many-to-one maps are ubiquitous in machine learning, from the image recognition model that assigns a multitude of distinct images to the concept of ``cat'' to the time series forecasting model which assigns a range of distinct time-series to a single scalar regression value. While the primary use of such models is naturally to associate correct output to each input, in many problems it is also useful to be able to explore, understand, and sample from a model's fibers, which are the set of input values x such that f(x) = y, for fixed y in the output space. In this paper we show that popular generative architectures are ill-suited to such tasks. Motivated by this we introduce a novel generative architecture, a Bundle Network, based on the concept of a fiber bundle from (differential) topology. BundleNets exploit the idea of a local trivialization wherein a space can be locally decomposed into a product space that cleanly encodes the many-to-one nature of the map. By enforcing this decomposition in BundleNets and by utilizing state-of-the-art invertible components, investigating a network's fibers becomes natural.

Courts, Nicolas C.↗

Imaging divertor strike point splitting in RMP ELM suppression experiments in the DIII-D tokamak [Imaging divertor strike point splitting in RMP ELM suppression experiments]

Fast visible imaging of the lower divertor from above is used to study the structure and dynamics of lobes induced by resonant magnetic perturbations (RMPs) in Edge-Localized Mode (ELM) suppression experiments in DIII-D. The best compromise between the amount of light and sharp imaging was obtained using emission at 601 nm from Fulcher band molecular deuterium. Multiple spatially resolved peaks in the D 2 emission, taken as a proxy for the particle flux, are readily resolved during RMPs, in contrast to the heat flux measured by infrared cameras, which shows little spatial structure in ITER-like conditions. The 25 mm objective lens provides high spatial resolution (2–4 mm/pixel) from the centerpost to the outer shelf over 40° toroidally that overlaps the field of view of the IRTV that measures the divertor heat flux, allowing direct comparison in non-axisymmetric discharges. The image is coupled to a Phantom 7.3 camera using a Schott wound fiber bundle, providing high temporal resolution that allows the lobe dynamics to be resolved between ELMs and across ELM suppression onset. Furthermore, these measurements are used to study the heat and particle flux in 3D magnetic fields and to validate models for the plasma response to RMPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress on the Development of a Step Height Sensor for the BOLT Flight Vehicle

This presentation will summarize progress on the development of a step height sensor for the BOLT flight vehicle. Two methods have been proposed to measure the step size in this effort.The first method involves the application of miniaturized camera embedded in the flight vehicle that views the step through a rearward-facing port (shown in Fig. 1a inset). The second method involves the application of a linear fiber optic array bundle to measure the intensity of light reflected back from the aft body step (concept shown in Fig. 1b). Preliminary testing with the miniaturized camera has been performed in the lab and shows that displacements of ≤10 μm can be measured using this method. Final testing with both methods will be performed on the test stand shown in Fig. 1a. This test stand will include a fine adjustment vertical translation stage that will be used to adjust the step height in steps of 1-2 μm. A high-magnification imaging system will also be used to verify the step height. The miniaturized camera and linear fiber optic array bundle will be mounted in one of several port holes with varying degrees of inclination relative to the top surface in the opposing aft-section slab. BOLT flight vehicle details and information on the steps can be found in Ref. [1].

BOLT↗

Pedestal fluctuation measurements with charge exchange imaging at the DIII-D tokamak

A new high radial resolution 2D multichannel Charge eXchange Imaging (CXI) diagnostic is under development for deployment at DIII-D. Here, the diagnostic system will measure low-to-intermediate radial wavenumber carbon density fluctuations by observing the n = 8 – 7 (λ = 529.06 nm) C-VI emission line, resulting from charge exchange collisions between heating neutral beam atoms and the intrinsic carbon ion density. The new CXI diagnostic will provide measurements with ΔR ~ 0.4 cm to access higher k r instabilities (k r < 8 cm –1 ) predicted to arise in the steep-gradient region of the H-mode pedestal. The CXI system will feature 60 fiber bundles in a 12 × 5 arrangement, with each bundle consisting of four 1 mm fibers. A custom optical system has been designed to filter and image incoming signals onto an 8 × 8 avalanche photodiode array. Additionally, a novel electronics suite has been designed and commissioned to amplify and digitize the relatively low-intensity carbon signal at a 2 MHz bandwidth. Forward modeling results of the active C-VI emission suggest sufficient signal to noise ratios to resolve turbulent fluctuations. Prototype measurements demonstrate the ability to perform high frequency pedestal measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Side-Looking Viewer for Crevices

Side-looking optical viewer inserted into gap 1 mm wide to depth of 10 cm. Instrument allows human observer to inspect small crevices from comfortable viewing angle. Small mirror atop pair of thin, flat legs inserted into gap. Mirror reflects image of gap wall or other object into microscope, which magnifies image 20 times. Quartz/halogen lamp in separate unit provides light to illuminate gap via optical-fiber bundle. Observer looks directly through microscope or attaches photographic or video camera without disturbing setup.

Hagen, G. R.↗

Robotic Vision for Welding

Vision system for robotic welder looks at weld along axis of welding electrode. Gives robot view of most of weld area, including yet-unwelded joint, weld pool, and completed weld bead. Protected within welding-torch body, lens and fiber bundle give robot closeup view of weld in progress. Relayed to video camera on robot manipulator frame, weld image provides data for automatic control of robot motion and welding parameters.

Richardson, R. W.↗

Design and initial performance evaluation of a portable short wave infrared spectroradiometer

The design, initial calibration, and performance evaluations of a portable short wave infrared (SWIR) spectroradiometer are described. The spectroradiometer covers the range from 1.1 to 2.5 microns with a spectral resolution that may be varied from less than 10 nm to more than 100 nm. A single spectrum is acquired in about 2 sec. The SNR is about 230 at a wavelength of 2.2 microns for a Lambertian surface of 90-percent reflectance illuminated by the sun at normal incidence with 14.8-nm resolution, a 25 C background temperature, and no atmospheric attenuation. FOV-defining optics are coupled by a flexible fiber-optics bundle to the spectroradiometer, which consists of a concave holographic diffraction grating with a flat focal field imaged onto a 1024-element platinum silicide linear-array detector.

Smith, Mark W.↗

Performance Comparison of Object Detection Networks for Shrapnel Identification in Ultrasound Images

Ultrasound imaging is a critical tool for triaging and diagnosing subjects but only if images can be properly interpreted. Unfortunately, in remote or military medicine situations, the expertise to interpret images can be lacking. Machine-learning image interpretation models that are explainable to the end user and deployable in real time with ultrasound equipment have the potential to solve this problem. We have previously shown how a YOLOv3 (You Only Look Once) object detection algorithm can be used for tracking shrapnel, artery, vein, and nerve fiber bundle features in a tissue phantom. However, real-time implementation of an object detection model requires optimizing model inference time. Here, we compare the performance of five different object detection deep-learning models with varying architectures and trainable parameters to determine which model is most suitable for this shrapnel-tracking ultrasound image application. We used a dataset of more than 16,000 ultrasound images from gelatin tissue phantoms containing artery, vein, nerve fiber, and shrapnel features for training and evaluating each model. Every object detection model surpassed 0.85 mean average precision except for the detection transformer model. Overall, the YOLOv7tiny model had the higher mean average precision and quickest inference time, making it the obvious model choice for this ultrasound imaging application. Other object detection models were overfitting the data as was determined by lower testing performance compared with higher training performance. In summary, the YOLOv7tiny object detection model had the best mean average precision and inference time and was selected as optimal for this application. Next steps will implement this object detection algorithm for real-time applications, an important next step in translating AI models for emergency and military medicine.

60 APPLIED LIFE SCIENCES↗

Fiber-coupled high resolution infrared array spectrometer for the Kuiper Airborne Observatory

A novel cryogenic grating spectrometer (FCAS) is being designed for observations of volatiles in cometary and planetary atmospheres, and in newly forming planetary systems. The instrument features two-dimensional detector arrays coupled to a high-dispersion echelle by infrared fibers, and will achieve a spectral resolving power of about 40,000. The primary observational platform for this instrument will be the Kuiper Airborne Observatory, but it will also be configured for use at ground-based observatories. Initially, the spectrometer will use a 58 x 62, 1- to 5-micron InSb array. Larger-format IR arrays and arrays of different composition, will later be incorporated as they become available. The instrument will be used in two modes. The first uses a large format IR array in the spectral image plane for the customary one-dimensional spectral-one-dimensional spatial coverage. In the second mode, a massive, coherent bundle of infrared transmitting ZrF4 fibers will be installed after the dispersive element, to reformat the two-dimensional array into an elongated one-dimensional array for wide spectral coverage, allowing multiple lines to be measured in a single integration with high sensitivity. The overall instrument design is discussed, and the system sensitivity is estimated.

Glenar, D. A.↗

High Resolution Multimode Fiber Image Recovery

The research emphasis is on developing a cost-effective method of recovering image information from small, closely confined spaces using multimode fibers. The state-of-the-art good quality-viewing fiber, which can currently be used for performing this function, is a 0.5 mm diameter bundle containing 6000 pixels at a cost of $10,000 per fiber bundle. However, these fiber bundles are very fragile and can easily break during surgical use, thereby making instrument reliability and replacement cost,a major impediment to their routine use in many applications. The advantage of working with a single multimode fiber is that it is significantly less expensive and mechanically more robust. In addition, careful choice of numerical aperture allows a higher image resolution (roughly 750,000 pixels) with a 0.5 mm diameter multimode fiber.

Jackson, Deborah↗

The Solar Neutron TRACking (SONTRAC) Instrument for the Detection of Fast Neutrons

Fast neutrons (energies >0.5 MeV) contribute to the radiation exposure of space hardware and astronaut crew, enable greater understanding of planetary atmospheric and surface compositions and allow unique measurements of solar particle acceleration. Neutrons are challenging to detect and measurements of them typically suffer from high background rates. High energy neutrons (>50 MeV) pose even more challenges, because the traditional double-scatter technique based on a time-of-flight (ToF) measurement. These measurements are challenging due to size constraints on satellites, particularly newer small satellites. The SOlar Neutron TRACking instrument (SONTRAC) is a small satellite neutron detector that utilizes fine-grained scintillating fiber bundles with 1-mm pitch silicon photomultiplier (SiPM) array readout. Signal processing is accomplished with multichannel ASICs. SONTRAC is able to image fast neutron (between 20-200 MeV) scatters in a compact scalable package. We discuss below the numerous applications of this technology and recent progress on the development and performance characteristics of the prototype instrument.

Georgia A de Nolfo↗

Photofield electron emission from an optical fiber nanotip

In this work, we demonstrate a nanotip electron source based on a graded index multimode silica optical fiber, tapered at one end to a radius of curvature r ~50 nm and coated with a thin film of gold. We report observation of laser-induced electron photoemission at tip bias potentials below the onset of dark field emission. Single-photon photofield emission is identified as the emission mechanism that exhibits fast switching times with an upper limit on the order of 1 μ s. The explored fiber optic nanotips are flexible back-illuminated emitters, which can be operated in continuous wave and pulsed modes using lasers with photon energies in the visible range or higher. The mechanical flexibility of the source can facilitate externally controlled positioning. Multiple, individually addressable, nanotips may be assembled into a bundle for applications such as computational electron ghost imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-resolution fiber imaging for pulsed power experiments

This work presents a novel approach for imaging the visible emissions from plasmas in pulsed power experiments using high-resolution plastic optical fibers. The diagnostic consists of a 2 mm diameter core commercial cable constructed of 13 000 individual acrylic fibers. The fibers are fused together to create a single high-resolution bundle. Different designs were investigated to cover a wide range of resolutions and fields of view (3–700 µm and 0.05–45 mm, respectively). The system was tested on the 1-MA Mykonos accelerator at Sandia National Laboratories and successfully imaged visible emission from a hybrid x-pinch target. Diagnostic development and preliminary results are presented.

Fulford, K. W. (ORCID:0000000309691832)↗

Imaging The Leading Edge Of A Weld

Proposed optical system integrated into plasma arc welding torch provides image of leading edge of weld pool and welding-arc-initiation point. Welding torch aligned better with joint. System includes coherent bundle of optical fibers and transparent cup.

Mcgee, William F.↗