Atomic Beam Laser Spectrometer for In-field Isotopic Analysis

This is a powerpoint presentation for the DTRA quarterly program review that goes into detail about the atomic beam laser spectrometer for in-field isotopic analysis. The project goals are the following: analysis of post-detonation debris, determination of U and Pu isotopic composition, and fieldable prototype: < 2ft 3 , < 1000W.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Possible Nuclear Safeguards Applications: Workshop on Next-Generation Laser Compton Gamma Source

These are a set of slides for the development of a next-generation photon source white paper. The following topics are covered in these slides: Nuclear Safeguards; The Nuclear Fuel Cycle; Precise isotopic determination via NRF; UF 6 Enrichment Assay; and Non-Destructive Assay of Spent Nuclear Fuel. In summary: A way to non-destructively measure precise isotopics of ~kg and larger samples has multiple uses in nuclear safeguards; Ideally this is a compact, fieldable device that can be used by international inspectors. Must be rugged and reliable; A next-generation source can be used as a testing ground for these techniques as technology develops.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Analyses of Field Test Data at the Atucha-1 Spent Fuel Pools

A field test was conducted at the Atucha-1 spent nuclear fuel pools to validate a software package for gross defect detection that is used in conjunction with the inspection tool, Spent Fuel Neutron Counter (SFNC). A set of measurements was taken with the SFNC and the software predictions were compared with these data and analyzed. The data spanned a wide range of cooling times and a set of burnup levels leading to count rates from the several hundreds to around twenty per second. The current calibration in the software using linear fitting required the use of multiple calibration factors to cover the entire range of count rates recorded. The solution to this was to use power regression data fitting to normalize the predicted response and derive one calibration factor that can be applied to the entire set of data. The resulting comparisons between the predicted and measured responses were generally good and provided a quantitative method of detecting missing fuel in virtually all situations. Since the current version of the software uses the linear calibration method, it would need to be updated with the new power regression method to make it more user-friendly for real time verification and fieldable for the range of responses that will be encountered.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Scoping study to expedite development of a field deployable and portable instrument for UF6 enrichment assay

The primary objective of the present study is to identity the most promising, viable technologies that are likely to culminate in an expedited development of the next-generation, field-deployable instrument for providing rapid, accurate, and precise enrichment assay of uranium hexafluoride (UF6). UF6 is typically involved, and is arguably the most important uranium compound, in uranium enrichment processes. As the first line of defense against proliferation, accurate analytical techniques to determine the uranium isotopic distribution in UF6 are critical for materials verification, accounting, and safeguards at enrichment plants. As nuclear fuel cycle technology becomes more prevalent around the world, international nuclear safeguards and interest in UF6 enrichment assay has been growing. At present, laboratory-based mass spectrometry (MS), which offers the highest attainable analytical accuracy and precision, is the technique of choice for the analysis of stable and long-lived isotopes. Currently, the International Atomic Energy Agency (IAEA) monitors the production of enriched UF6 at declared facilities by collecting a small amount (between 1 to 10 g) of gaseous UF6 into a sample bottle, which is then shipped under chain of custody to a central laboratory (IAEA’s Nuclear Materials Analysis Laboratory) for high-precision isotopic assay by MS. The logistics are cumbersome and new shipping regulations are making it more difficult to transport UF6. Furthermore, the analysis is costly, and results are not available for some time after sample collection. Hence, the IAEA is challenged to develop effective safeguards approaches at enrichment plants. In-field isotopic analysis of UF6 has the potential to substantially reduce the time, logistics and expense of sample handling. However, current laboratory-based MS techniques require too much infrastructure and operator expertise for field deployment and operation. As outlined in the IAEA Department of Safeguards Long-Term R&D Plan, 2012–2023, one of the IAEA long-term R&D needs is to “develop tools and techniques to enable timely, potentially real-time, detection of HEU (Highly Enriched Uranium) production in LEU (Lowly Enriched Uranium) enrichment facilities” (Milestone 5.2). Because it is common that the next generation of analytical instruments is driven by technologies that are either currently available or just now emerging, one reasonable and practical approach to project the next generation of chemical instrumentation is to track the recent trends and to extrapolate them. This study adopted a similar approach, and an extensive literature review on existing and emerging technologies for UF6 enrichment assay was performed. The competitive advantages and current limitations of different analytical techniques for in-field UF6 enrichment assay were then compared, and the main gaps between needs and capabilities for their field use were examined. Subsequently, based on these results, technologies for the next-generation field-deployable instrument for UF6 enrichment assay were recommended. The study was organized in a way that a suite of assessment metric was first identified. Criteria used in this evaluation are presented in Section 1 of this report, and the most important ones are described briefly in the next few paragraphs. Because one driving force for in-field UF6 enrichment assay is related to the demanding transportation regulation for gaseous UF6, Section 2 contains a review of solid sorbents that convert and immobilized gaseous UF6 to a solid state, which is regarded as more transportation friendly and is less regulated. Furthermore, candidate solid sorbents, which show promise in mating with existing and emerging assay technologies, also factor into technology recommendations. Extensive literature reviews on existing and emerging technologies for UF6 enrichment assay, covering their scientific principles, instrument options, and current limitations are detailed in Sections 3 and 4, respectively. In Section 5, the technological gaps as well as start-of-the-art and commercial off-the-shelf components that can be adopted to expedite the development of a fieldable or portable UF6 enrichment-assay instrument are identified and discussed. Finally, based on the results of the review, requirements and recommendations for developing the next-generation field-deployable instrument for UF6 enrichment assay are presented in Section 6.

36 MATERIALS SCIENCE↗

Advanced Diagnostic and Sample Preparation Platform for Early Threat Surveillance

Emerging infectious diseases present a profound threat to global health, economic development, and political stability, and therefore represent a significant national security concern for the United States. The increased prevalence of international travel and globalized trade further amplify the threat of infectious disease outbreaks of catastrophic effect. The key to containing and eradicating an outbreak before it goes global is rapid identification of index cases and initial clusters of affected individuals. This depends upon establishment of a biosurveillance network that effectively reaches infectious disease hotspots in even the most remote regions of the world and provides a network-integrated, location-appropriate diagnostic capability. At present, there are two critical needs which must be addressed in order to extend biosurveillance activities beyond centralized laboratory facilities: 1) A simple, reliable, and safe method for immediate stabilization of clinical specimens in the field; and 2) A flexible sample processing platform that enables in-field preparation of clinical specimens for rapid, on-site analysis using a variety of diagnostic assay platforms. These needs are not necessarily mutually exclusive; in fact, we propose that they are most efficiently addressed by a deployable sample processing platform that immediately stabilizes the information content of clinical specimens through transformation of the inherently unstable analytes of interest into stable equivalents that are appropriately formatted for downstream analysis. In order to address this problem, we have developed a sample processing pipeline and microfluidics-based platform modules enabling: 1) Extraction of total RNA from finger-stick quantities of human whole blood; and 2) Microscale synthesis of appropriately-formatted cDNA products that capture the information content of blood RNA in a stable form that supports pathogen detection and/or characterization via PCR and/or Second Generation Sequencing (SGS). Through this research we have discovered new, effective solutions for problems that thus far have hindered use of digital microfluidics (DMF) in biomedical applications. Our work reveals a clear path forward to fieldable, automated sample processing systems that will enable rapid, on-site identification of usual-suspect and novel pathogens in clinical specimens for improved biosurveillance.

59 BASIC BIOLOGICAL SCIENCES↗

R200 Spectrometer with Frisch-grid Cadmium Zinc Telluride (CZT)

The goal of this project is to demonstrate an engineering prototype of a gamma ray spectrometer that uses Cadmium Zinc Telluride (CZT) in a configuration comprised of an array of position-sensitive virtual Frisch grid (PSVFG) detectors and show its capability to perform functions that would be useful to the IAEA. The detectors should achieve energy resolution of 2-3% at 200 keV and <1% at > 662 keV (at temperature <30°C), thereby outperforming all hand-held instruments currently in use other than cryogenically cooled germanium. BNL is working to transfer the technology to an industrial partner so that robust, fieldable instruments can be manufactured.

36 MATERIALS SCIENCE↗

Magnetic Detection of Chemical Threats

Los Alamos researchers have developed a technology to quickly detect chemical threats using a fieldable detector that provides real-time detection to ensure safety for warfighters, agricultural workers, and the general public. Traditional laboratory-based detection does not allow for agile response to threats on the battlefield or to our food supply chain. Our portable detector brings the laboratory to the field for real-time detection of chemical agents in samples without needing to send the samples to a remote location for analysis. This technology fits a market need in public safety, military sensor design, and pesticide detection. We have proven that this technology works on the benchtop, and are working to miniaturize the system to enable deployment. We are seeking qualified licensing or CRADA partners to finalize development of this system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predicting Ionizing Radiation Exposure (LDRD Final Report)

Rapid, low-cost, easy-to-use devices are needed for screening large populations potentially exposed to ionizing radiation following accidental or intentional release of radioactive materials. Measurements of radiation responsive messenger RNA (mRNA) biomarkers using fieldable devices could provide such a tool. mRNA expression level changes may be useful for discriminating between exposed individuals and the worried well and estimating the radiation dose received even days after exposure. Loop mediated isothermal amplification, or LAMP, is an established nucleic acid amplification technique that provides key advantages for use in low cost, portable instruments. We proposed to use LAMP to determine if the expression level of one or a small number of radiation responsive biomarkers can be used to discriminate unexposed cells from ionizing radiation (IR)-exposed cells. If successful, this methodology could potentially be transitioned to portable detection technology for use in population screening after large-scale events. Our approach involved designing quantitative, real-time, reverse transcriptase loop-mediated isothermal amplification (RTLAMP) assays for a panel of published IR-responsive mRNA biomarkers and control genes. This assay panel was then tested on mRNA isolated from white blood cells, lymphocyte cell lines and samples from internally dosed individuals. We used standard curves to quantify mRNA copy number along with the comparative Ct method to measure relative mRNA expression changes. We were able to generate quantitative and comparative gene expression changes for many of the samples evaluated. Although promising in its potential to measure gene expression, the technique suffered when attempting to amplify target genes with very low background RNA expression levels, in particular, FDXR in controls samples. Future work should focus on optimizing the RT-LAMP reaction for low RNA expression level targets allowing for the generation of validated assay panels.

59 BASIC BIOLOGICAL SCIENCES↗

Narrow-linewidth laser cooling for rapid production of low-temperature atoms for high data-rate quantum sensing

We present a proof-of-concept demonstration of a narrow linewidth $^{87}$Rb magneto-optical trap (MOT) operating on the narrow linewidth $5S_{1/2}$ → $6P_{3/2}$ transition at 420 nm. We stabilized the absolute frequency of the 420 nm laser to an atomic transition in $^{87}$Rb and demonstrate a MOT using 420 nm light driving the $5S_{1/2}$, $F = 2$ → $6P_{3/2}, F' = 3$ transition. We then use tome-of-flight measurements to characterize the 420 nm MOT temperature, observing a minimum temperature of about $T^{(420)}_{horizontal}$ = 150μK and $T^{(420)}_{vertical}$ = 250μK before the opportunity to perform significant characterization and optimization. Although this temperature is significantly higher then the expected 420 nm Doppler cooling limit ($T_D^{(420)}$ ≈ 34 μK), these are already approaching the Doppler limit of a standard 780 nm MOT ($T_D^{(780)}$ ≈ 146 μK). We believe that with further optimization the Doppler cooling limit of ≈ 34 μK can be achieved. This initial result answers our key research question and demonstrates the viability of applying narrow linewidth laser cooling as a robust technique for future fieldable quantum sensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SEDONA and ERDE: Portable Detection of Chemical Agents by Low Magnetic Field Nuclear Magnetic Resonance [Slides]

Two spectrometer systems have been developed at LANL for hazardous and/or toxic chemical agent detection and forensic analysis: SpEctroscopic Detection Of Nerve Agents (SEDONA) is a portable bottle scanner; and Earth’s field Resonance Detection and Evaluation (ERDE) Devices are fieldable J-coupled Earth’s Field - NMR (EF-NMR) spectrometers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid Fabrication of High Frame Rate Multichannel FTIR Spectrometers

Spectrally resolved signals in the short- to mid-wave infrared (SWIR/MWIR) bands at high-temporal resolution are critical for many national security remote sensing missions. Currently available off the shelf technology can achieve either high temporal resolution or high spectral resolution, but rugged instruments that can achieve both simultaneously remain mostly in the realm of one-off R&D projects. This report documents efforts to demonstrate a new technique for designing and building high resolution, high framerate multichannel FTIR (MC-FTIR) spectrometers that operate in the SWIR/MWIR bands. The core optical element in a MC-FTIR spectrometer is an array of statically-tuned lamellar grating interferometers (LGI). In the original MC-FTIR work these arrays were fabricated using a synchrotron x-ray lithography method. We proposed to instead fabricate these LGI arrays using multiphoton lithography (MPL), a 3D printing technique that can fabricate meso-scale structures with sub-micron precision. Although we were able to fabricate LGI arrays of sufficient size using MPL, the realized optical surfaces had unsuitably high optical form errors, precluding their use in a fieldable instrument. Further advancement in MPL technology may eventually enable fabrication of interferometer-grade LGI arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Infrared Database of n/k Optical Constants for Calculating Aerosol Spectra for the PICARD Program

The objective of the PICARD Program is to develop fieldable sensing platforms for the rapid chemical identification of aerosol particles in plumes. Standoff detection involves interrogating the aerosol cloud from a distance using optical methods and probing the signal returned from direct backscattering from the aerosol particles or transmitted through the plume after reflection from a retroreflector or surface of opportunity (SOO). The identification of chemical species, however, in aerosols is complicated by their complex compositions and morphologies, chemical interferants, and non-uniform particle sizes. To advance standoff detection of aerosols, modelling the infrared transmittance, reflectance and scattering spectra of aerosolized liquid and solid chemical compounds is required, and then testing that model experimentally via laboratory and field experiments. To perform accurate modeling, the infrared optical constants (n/k), i.e., the complex refractive index, of the compounds of interest are required. Thus, PNNL was tasked to provide the optical constants for a set of analytes relevant to the PICARD program. This report describes the experimental techniques used to derive the optical constants of both liquid and solid compounds using established “gold-standard” protocols, how the experimental data are processed to produce the wavenumber dependent optical constant vectors, and how the data are used in the aerosol absorption spectra modeling.

complex refractive index↗

Abiotic and Biotic Damage of Microalgae Generate Different Volatile Organic Compounds (VOCs) for Early Diagnosis of Algal Cultures for Biofuel Production

Open microalgal ponds used in industrial biomass production are susceptible to a number of biotic and abiotic environmental stressors (e.g., grazers, pathogens, pH, temperature, etc.) resulting in pond crashes with high economic costs. Identification of signature chemicals to aid in rapid, non-invasive, and accurate identification of the stressors would facilitate targeted and effective treatment to save the algal crop from a catastrophic crash. Specifically, we were interested in identifying volatile organic compounds (VOCs) that can be used to as an early diagnostic for algal crop damage. Cultures of Microchloropsis gaditana were subjected to two forms of algal crop damage: (1) active grazing by the marine rotifer, Brachionus plicatilis, or (2) repeated freeze–thaw cycles. VOCs emitted above the headspace of these algal cultures were collected using fieldable solid phase microextraction (SPME) fibers. An untargeted analysis and identification of VOCs was conducted using gas chromatography-mass spectrometry (GC-MS). Diagnostic VOCs unique to each algal crop damage mechanism were identified. Active rotifer grazing of M. gaditana was characterized by the appearance of carotenoid degradation products, including β-cyclocitral and various alkenes. Freeze–thaw algae produced a different set of VOCs, including palmitoleic acid. Both rotifer grazing and freeze–thawed algae produced β-ionone as a VOC, possibly suggesting a common stress-induced cellular mechanism. Importantly, these identified VOCs were all absent from healthy algal cultures of M. gaditana. Early detection of biotic or abiotic environmental stressors will facilitate early diagnosis and application of targeted treatments to prevent algal pond crashes. Thus, our work further supports the use of VOCs for monitoring the health of algal ponds to ultimately enhance algal crop yields for production of biofuel.

09 BIOMASS FUELS↗

Smartphone-Based Device for Colorimetric Detection of MicroRNA Biomarkers Using Nanoparticle-Based Assay

The detection of microRNAs (miRNAs) is emerging as a clinically important tool for the non-invasive detection of a wide variety of diseases ranging from cancers and cardiovascular illnesses to infectious diseases. Over the years, miRNA detection schemes have become accessible to clinicians, but they still require sophisticated and bulky laboratory equipment and trained personnel to operate. The exceptional computing ability and ease of use of modern smartphones coupled with fieldable optical detection technologies can provide a useful and portable alternative to these laboratory systems. Herein, we present the development of a smartphone-based device called Krometriks, which is capable of simple and rapid colorimetric detection of microRNA (miRNAs) using a nanoparticle-based assay. The device consists of a smartphone, a 3D printed accessory, and a custom-built dedicated mobile app. We illustrate the utility of Krometriks for the detection of an important miRNA disease biomarker, miR-21, using a nanoplasmonics-based assay developed by our group. We show that Krometriks can detect miRNA down to nanomolar concentrations with detection results comparable to a laboratory-based benchtop spectrophotometer. With slight changes to the accessory design, Krometriks can be made compatible with different types of smartphone models and specifications. Thus, the Krometriks device offers a practical colorimetric platform that has the potential to provide accessible and affordable miRNA diagnostics for point-of-care and field applications in low-resource settings.

Krishnan, Tushar (ORCID:0000000342610336)↗

The Evolution of Medical Countermeasures for Ebola Virus Disease: Lessons Learned and Next Steps

The Ebola virus disease outbreak that occurred in Western Africa from 2013–2016, and subsequent smaller but increasingly frequent outbreaks of Ebola virus disease in recent years, spurred an unprecedented effort to develop and deploy effective vaccines, therapeutics, and diagnostics. This effort led to the U.S. regulatory approval of a diagnostic test, two vaccines, and two therapeutics for Ebola virus disease indications. Moreover, the establishment of fieldable diagnostic tests improved the speed with which patients can be diagnosed and public health resources mobilized. The United States government has played and continues to play a key role in funding and coordinating these medical countermeasure efforts. Here, we describe the coordinated U.S. government response to develop medical countermeasures for Ebola virus disease and we identify lessons learned that may improve future efforts to develop and deploy effective countermeasures against other filoviruses, such as Sudan virus and Marburg virus.

59 BASIC BIOLOGICAL SCIENCES↗

A high resolution, adjustable, lockable laser mirror mount

A prototype high resolution, adjustable, lockable mirror mount is described, suitable for use as a resonator end mirror mount in fieldable lasers. The prototype was vibrated to 15g levels, 10-2000 Hz, and was shown to be stable to within 1 arc second and settable to an accuracy of 10 arc seconds. Improvements to be made to the prototype are outlined which will significantly improve the accuracy without sacrificing the other attributes of the prototype.

Chadwick, C. H.↗

Ultra-stable Hg(+) trapped ion frequency standard

A fieldable trapped ion frequency standard based on Hg-199(+) ions confined in a hybrid rf/dc linear ion trap is developed. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the rf confining fields. In preliminary measurements a stability of 2 to 3 x 10(exp -15) was obtained for 10000 second averaging times. These measurements were carried out with a 120 mHz wide atomic resonance line for the 40.5 GHz clock transition with a second order Doppler shift from the rf trapping field of 6 x 10(exp -13).

Prestage, John D.↗

Linear ion trap based atomic frequency standard

In order to develop a trapped ion-based fieldable frequency standard with stability 1 x 10 to the -13th/sq rt tau for averaging times tau greater than 10,000 s, a hybrid RF/DC linear ion trap was developed which permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. The authors have confined Hg-199(+) ions in this trap and have measured very high Q transitions with good SNRs. In preliminary measurements they obtained stabilities of 1.6 x 10 to the -13th/sq rt tau (tau between 50 and 800 s) with a 160-mHz wide atomic resonance linewidth and a signal-to-noise ratio of 40 for each measurement cycle. Atomic resonance lines as narrow as 30 mHz on the 40.5-GHz clock transition have been measured with no appreciable reduction in the ion signal. A stability of 7 x 10 to the -14th/sq rt tau is made possible by the signal-to-noise and line Q of this measured transition. Analysis of fundamental sources of frequency instability indicates that a long-term stability of 2 x 10 to the -16th is feasible for this device with existing technology for tau = 10 to the 6th s or more.

Prestage, John D.↗