At least 55 records · Page 3

Filling in the retinal image

The optics of the eye form an image on a surface at the back of the eyeball called the retina. The retina contains the photoreceptors that sample the image and convert it into a neural signal. The spacing of the photoreceptors in the retina is not uniform and varies with retinal locus. The central retinal field, called the macula, is densely packed with photoreceptors. The packing density falls off rapidly as a function of retinal eccentricity with respect to the macular region and there are regions in which there are no photoreceptors at all. The retinal regions without photoreceptors are called blind spots or scotomas. The neural transformations which convert retinal image signals into percepts fills in the gaps and regularizes the inhomogeneities of the retinal photoreceptor sampling mosaic. The filling-in mechamism plays an important role in understanding visual performance. The filling-in mechanism is not well understood. A systematic collaborative research program at the Ames Research Center and SRI in Menlo Park, California, was designed to explore this mechanism. It was shown that the perceived fields which are in fact different from the image on the retina due to filling-in, control some aspects of performance and not others. Researchers have linked these mechanisms to putative mechanisms of color coding and color constancy.

Larimer, James↗

Analytical modelling of no-vent fill process

An analytical model called FILL is presented which represents the first step in attaining the capability for no-vent fill of cryogens in space. The model's analytical structure is described, including the equations used to calculate transient thermodynamic behavior in different regions of the tank. The code predictions are compared with data from recent no-vent fill ground tests using Freon-114. The results are used to validate the FILL model to evaluate the viability of universal submerged jet theory in predicting system-level condensation effects.

Vaughan, David A.↗

Enhancement of the no-vent fill process

This paper presents an analytical and experimental evaluation of an enhanced techniques for no-vent fill. The method entails injecting liquid through the top of the receiver vessel, thereby increasing surface area and agitation of the ullage/liquid interface. Both of these factors promote condensation induced ullage collapse, and reduce compressive impedance to the incoming liquid. The enhanced process was analyzed by modifying the surface area algorithm of an existing tank thermodynamic code to model a downward-pointing, conical jet impringing on a steadily rising liquid surface. Transient pressure and temperature measurements from several tests with Freon-114 were input into the revised model to calculate condensation rate as a function of fill level. By expressing these rates in dimensionless form (i.e., in terms of Stanton number and Prandtl number), an empirical correlation similar to the submerged jet model of Brown and Sonin (1989) was derived. This provided a basis for developing an expression which relates top fill to bottom fill performance.

Vaughan, David A.↗

No-vent fill pressurization tests using a cryogen simulant

The results are described of an experimental program which studied the performance of various no-vent fill techniques for tank-to-tank liquid transfer. The tests were performed using a cryogen simulant (Freon-114) and a test bed consisting of a multiple tank/plumbing network that enabled studies of a variety of different inlet flow and active mixing regimes. Several results and conclusions were drawn from the 26 transfer experiments comprising the program. Most notable was the significant improvement in fill performance (i.e., minimized fill time and maximized fill fraction) with increased agitation of the liquid surface. Another was the close correlation between measured condensation rates and those predicted by recent theories which express condensation as a function of turbulent eddy effects on the liquid surface. In most cases, test data exhibited strong agreement with an analytical model which accounts for tank heat transfer and thermodynamics in a 1 g environment.

Schmidt, G. R.↗

Backscatter RCS for TE and TM excitations of dielectric-filled cavity-backed apertures in two-dimensional bodies

Transverse electric (TE) and transverse magnetic (TM) scattering from dielectric-filled, cavity-backed apertures in two-dimensional bodies are treated using the method of moments technique to solve a set of combined-field integral equations for the equivalent induced electric and magnetic currents on the exterior of the scattering body and on the associated aperture. Results are presented for the backscatter radar cross section (RCS) versus the electrical size of the scatterer for two different dielectric-filled cavity-backed geometries. The first geometry is a circular cylinder of infinite length which has an infinite length slot aperture along one side. The cavity inside the cylinder is dielectric filled and is also of circular cross section. The two cylinders (external and internal) are of different radii and their respective longitudinal axes are parallel but not collocated. The second is a square cylinder of infinite length which has an infinite length slot aperture along one side. The cavity inside the square cylinder is dielectric-filled and is also of square cross section.

Goggans, Paul M.↗

No-vent fill pressurization tests using a cryogen simulant

The results are described of an experimental program which studied the performance of various no-vent fill techniques for tank-to-tank liquid transfer. The tests were performed using a cryogen simulant (Freon-114) and a test bed consisting of a multiple tank/plumbing network that enabled studies of a variety of different inlet flow and active mixing regimes. Several results and conclusions were drawn from the 26 transfer experiments comprising the program. Most notable was the significant improvement in fill performance (i.e., minimized fill time and maximized fill fraction) with increased agitation of the liquid surface. Another was the close correlation between measured condensation rates and those predicted by recent theories which express condensation as a function of turbulent eddy effects on the liquid surface. In most cases, test data exhibited strong agreement with an analytical model which accounts for tank heat transfer and thermodynamics in a 1 g environment.

Schmidt, G.↗

Nonvented Filling Of A Cryogenic Tank

Chilling before filling reduces ullage. Report describes experiments on nonvented filling of tank designed to store cryogenic liquids. Experiments showed if tank first chilled and evacuated, it can then be filled to more than 90 percent of its capacity without venting, provided conditions of chilling, initial tank pressure, and filling chosen properly. Developed for space applications, also useful in ground-based operations where venting impractical or hazardous.

Chato, David J.↗

Ground testing for the no-vent fill of cryogenic tanks: Results of tests for a 71 cubic foot tank

NASA Lewis Research has been investigating the no-vent fill method, since it is a promising approach to transfer liquid while handling the problems of low-g venting. This paper reports the results of a test series for filling a 71 cu ft tank with liquid hydrogen without venting. 22 tests were conducted, 10 with a bottom orifice as the inlet and 12 with a spray bar. Parameters investigated included inlet saturation pressures of approximately 5, 15, and 25 psia, transfer pressures of 20, 30, and 45 psia, and various starting wall temperatures. Of the tests, only the one run at the highest wall temperature (238 R) failed to fill the tank. Test results are compared to a thermodynamic equilibrium model. Overall model-data agreement was good except for the tendency of the model to overshoot during the initial wall cool down of the higher starting wall temperature fills.

Chato, David J.↗

Thermocryogenic buckling and stress analyses of a partially filled cryogenic tank subjected to cylindrical strip heating

Thermocryogenic buckling and stress analyses were conducted on a horizontally oriented cryogenic tank using the finite element method. The tank is a finite-length circular cylindrical shell with its two ends capped with hemispherical shells. The tank is subjected to cylindrical strip heating in the region above the liquid-cryogen fill level and to cryogenic cooling below the fill level (i.e., under thermocryogenic loading). The effects of cryogen fill level on the buckling temperature and thermocryogenic stress field were investigated in detail. Both the buckling temperature and stress magnitudes were relatively insensitive to the cryogen fill level. The buckling temperature, however, was quite sensitive to the radius-to-thickness ratio. A mechanical stress analysis of the tank also was conducted when the tank was under: (1) cryogen liquid pressure loading; (2) internal pressure loading; and (3) tank-wall inertia loading. Deformed shapes of the cryogenic tanks under different loading conditions were shown, and high-stress domains were mapped on the tank wall for the strain-gage installations. The accuracies of solutions from different finite element models were compared.

Ko, William L.↗

Investigation of an Aberrant Cell Voltage During the Filling of a Large Lithium Thionyl Chloride Cell

The investigation of an aberrant cell voltage during the filling of a large lithium thionyl chloride cell summary is at: an aberrant voltage trace was noted during the review of cell filling data; incident was traced to an interruption during filling; experimentation suggested oxidizable sites within the carbon electrode were responsible for the drop in voltage; the voltage anomaly could be reproduced by interrupting the filling of similar cells; and anomalous voltage dip was not due to a short.

Thaller, Lawrence H.↗

Rapid Chill and Fill of a Liquid Hydrogen Tank Demonstrated

The NASA Lewis Research Center, in conjunction with Boeing North American, has been supporting the High Energy Upper Stage (HEUS) program by performing feasibility studies at Lewis Supplemental Multilayer Insulation Research Facility (SMIRF). These tests were performed to demonstrate the feasibility of chilling and filling a tank with liquid hydrogen in under 5 minutes. The goal of the HEUS program is to release a satellite from the shuttle cargo bay and then use a cryogenic (high-energy) upper stage to allow the satellite to achieve final orbit. Because of safety considerations, the propellant tanks for the upper stage will be launched warm and dry. They will be filled from the shuttle's external tank during the mission phase after the solid rocket boosters have jettisoned and prior to jettison of the external tank. Data from previous shuttle missions have been analyzed to ensure that sufficient propellant would be available in the external tank to fill the propellant tank of the proposed vehicle upper stage. Because of mission time-line considerations, the propellant tanks for the upper stage will have to be chilled down and filled in approximately 5 minutes. An existing uninsulated flight weight test tank was installed inside the vacuum chamber at SMIRF, and the chamber was evacuated to the 10(exp -5) torr range to simulate space vacuum conditions in the cargo bay with the doors open. During prerun operations, the facility liquid hydrogen (LH2) supply piping was prechilled with the vent gas bypassing the test article. The liquid hydrogen supply dewar was saturated at local ambient pressure and then pressurized with ambient temperature gaseous helium to the test pressure. A control system was used to ensure that the liquid hydrogen supply pressure was maintained at the test pressure.

Kudlac, Maureen T.↗

Oxygen Compatibility of Brass-Filled PTFE Compared to Commonly Used Fluorinated Polymers for Oxygen Systems

Safe and reliable seal materials for high-pressure oxygen systems sometimes appear to be extinct species when sought out by oxygen systems designers. Materials that seal well are easy to find, but these materials are typically incompatible with oxygen, especially in cryogenic liquid form. This incompatibility can result in seals that leak, or much worse, seals that easily ignite and burn during use. Materials that are compatible with oxygen are easy to find, such as the long list of compatible metals, but these metallic materials are limiting as seal materials. A material that seals well and is oxygen compatible has been the big game in the designer's safari. Scientists at the Materials Combustion Research Facility (MCRF), part of NASA/Marshall Space Flight Center (MSFC), are constantly searching for better materials and processes to improve the safety of oxygen systems. One focus of this effort is improving the characteristics of polymers used in the presence of an oxygen enriched environment. Very few systems can be built which contain no polymeric materials; therefore, materials which have good impact resistance, low heat of combustion, high auto-ignition temperature and that maintain good mechanical properties are essential. The scientists and engineers at the Materials Combustion Research Facility, in cooperation with seal suppliers, are currently testing a new formulation of polytetrafluoroethylene (PTFE) with Brass filler. This Brass-filled PTFE is showing great promise as a seal and seat material for high pressure oxygen systems. Early research has demonstrated very encouraging results, which could rank this material as one of the best fluorinated polymers ever tested. This paper will compare the data obtained for Brass-filled PTFE with other fluorinated polymers, such as TFE-Teflon (PTFE) , Kel-F 81, Viton A, Viton A-500, Fluorel , and Algoflon . A similar metal filled fluorinated polymer, Salox-M , was tested in comparison to Brass-filled PTFE to demonstrate the importance of the metal chosen and relative percentage of filler. General conclusions on the oxygen compatibility of this formulation are drawn, with an emphasis on comparing and contrasting the materials performance to the performance of the current state-of-the-art oxygen compatible polymers.

Herald, Stephen D.↗

Hematite-Rich Fracture Fill at Meridiani Planum, Mars: Implications for Fluid Chemistry

The Mars Exploration Rover Opportunity has been operating at the surface of Mars for over 2100 sols and has driven a distance of approximately 20 km. Throughout the traverse, outcrop rocks with margins and fracture fill resistant to erosion have been imaged and analyzed in detail by the Moessbauer (MB) spectrometer and the Alpha Particle X-ray Spectrometer (APXS). A recent APXS analysis of an outcrop block excavated by a young impact crater shows a coating with the highest concentration of iron measured by either rover, not including the iron-nickel meteorites. Texturally, this sample (referred to as "Chocolate Hills -Aloya") appears as a cemented collection of partially fragmented \blueberries." With the exception of an elevated sulfur content, the elemental chemistry of this particular sample is entirely consistent with other analyses of hematite spherules at Merdiani Planum. As a result, it is difficult to determine whether this coating, which may have been filling a fracture in outcrop rocks prior to disruption by the impact, was simply an agglomeration of spherules or a result of a more complicated aqueous process. In contrast, a number of other fracture-filling exposures and erosion-resistant rinds have been analyzed by the APXS and MB instruments showing significant concentrations of iron in the form of hematite without the texture of spherule fragments. In one of these samples, a broken piece of fracture fill within Victoria crater referred to as "Dorsal," showed over 50% of the iron in hematite, the highest Mn concentration of any sample measured by the rovers, and elevated levels of Cl and Br. While the Fe:Mn ratio of the Dorsal analyses are comparable to that of Gusev and Meridiani basalts, it is clear that chemistry of this sample cannot be completely explained by a simple mixing of outcrop and blueberry compositions

Yen, Albert↗

Filling-in of Near-infrared Solar Lines by Terrestrial Fluorescence and Other Geophysical Effects: Simulations and Space-based Observations from SCIAMACHY and GOSAT

Global mapping of terrestrial vegetation fluorescence from space has recently been accomplished with high spectral resolution (nu/nu greater than 35 000) measurements from the Japanese Greenhouse gases Observing SAellite (GOSAT). These data are of interest because they can potentially provide global information on the functional status of vegetation including light-use efficiency and global primary productivity that can be used for global carbon cycle modeling. Quantifying the impact of fluorescence on the O2-A band is important as this band is used for photon pathlength characterization in cloud- and aerosol-contaminated pixels for trace-gas retrievals including CO2. Here, we examine whether fluorescence information can be derived from space using potentially lower-cost hyperspectral instrumentation, i.e., more than an order of magnitude less spectral resolution (nu/nu approximately 1600) than GOSAT, with a relatively simple algorithm. We discuss laboratory measurements of fluorescence near one of the few wide and deep solar Fraunhofer lines in the long-wave tail of the fluorescence emission region, the calcium (Ca) II line at 866 nm that is observable with a spectral resolution of approximately 0.5 nm. The filling-in of the Ca II line due to additive signals from various atmospheric and terrestrial effects, including fluorescence, is simulated. We then examine filling-in of this line using the SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY) satellite instrument. In order to interpret the satellite measurements, we developed a general approach to correct for various instrumental artifacts that produce false filling-in of solar lines in satellite measurements. The approach is applied to SCIAMACHY at the 866 nm Ca II line and to GOSAT at 758 and 770 nm on the shoulders of the O2-A feature where there are several strong solar Fraunhofer lines that are filled in primarily by vegetation fluorescence. Finally, we compare temporal and spatial variations of SCIAMACHY additive signals with those of GOSAT and the Enhanced Vegetation Index (EVI) from the MODerate-resolution Imaging Spectroradiometer (MODIS). Although the derived additive signals from SCIAMACHY are extremely weak at 866 nm, their spatial and temporal variations are consistent with chlorophyll a fluorescence or another vegetation-related source. We also show that fillingin occurs at 866 nm over some barren areas, possibly originating from luminescent minerals in rock and soil.

vegetation↗

Vented Chill / No-Vent Fill of Cryogenic Propellant Tanks

Architectures for extended duration missions often include an on-orbit replenishment of the space vehicle's cryogenic liquid propellants. Such a replenishment could be accomplished via a tank-to-tank transfer from a dedicated tanker or a more permanent propellant depot storage tank. Minimizing the propellant loss associated with transfer line and receiver propellant tank thermal conditioning is essential for mass savings. A new methodology for conducting tank-to-tank transfer while minimizing such losses has been demonstrated. Charge-Hold-Vent is the traditional methodology for conducting a tank-to-tank propellant transfer. A small amount of cryogenic liquid is introduced to chill the transfer line and propellant tank. As the propellant absorbs heat and undergoes a phase change, the tank internal pressure increases. The tank is then vented to relieve pressure prior to another charge of cryogenic liquid being introduced. This cycle is repeated until the transfer lines and tank are sufficiently chilled and the replenishment of the propellant tank is complete. This method suffers inefficiencies due to multiple chill and vent cycles within the transfer lines and associated feed system components. Additionally, this system requires precise measuring of cryogenic fluid delivery for each transfer, multiple valve cycling events, and other complexities associated with cycled operations. To minimize propellant loss and greatly simplify on-orbit operations, an alternate methodology has been designed and demonstrated. The Vented Chill / No Vent Fill method is a simpler, constant flow approach in which the propellant tank and transfer lines are only chilled once. The receiver tank is continuously vented as cryogenic liquid chills the transfer lines, tank mass and ullage space. Once chilled sufficiently, the receiver tank valve is closed and the tank is completely filled. Interestingly, the vent valve can be closed prior to receiver tank components reaching liquid saturation temperature. An incomplete fill results if insufficient energy is removed from the tank's thermal mass and ullage space. The key to successfully conducting the no vent fill is to assure that sufficient energy is removed from the system prior to closing the receiver tank vent valve. This paper will provide a description of the transfer methodology and test article, and will provide a discussion of test results.

Rhys, Noah O.↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank

This paper presents a multi-node finite volume model of the chilling and filling of a cryogenic tank using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. Vented Chill and No Vent Fill (VCNVF) tests were conducted at Marshall Space Flight Center where a flight-like tank was filled with liquid nitrogen from a supply tank. In the VCNVF tests, the tank was partially chilled while the vent valve was open. After the partial chilling, the vent valve was closed and the tank was filled without any venting. An integrated numerical model of the test set up was developed. The model included the transfer line from the supply tank, the target tank with the spray nozzle and solid walls, and the discharge line with the vent valve. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor in the tank when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall and ullage temperature in the tank were compared with the test data.

Alok Majumdar↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank

This paper presents a multi-node finite volume model of the chilling and filling of a cryogenic tank using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. Vented Chill and No Vent Fill (VCNVF) tests were conducted at Marshall Space Flight Center where a flight-like tank was filled with liquid nitrogen from a supply tank. In the VCNVF tests, the tank was partially chilled while the vent valve was open. After the partial chilling, the vent valve was closed and the tank was filled without any venting. An integrated numerical model of the test set up was developed. The model included the transfer line from the supply tank, the target tank with the spray nozzle and solid walls, and the discharge line with the vent valve. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor in the tank when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall and ullage temperature in the tank were compared with the test data.

Alok Majumdar↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank with Thermo-dynamic Vent System Assisted Injector

This paper presents a multi-node finite volume model of No Vent Filling (NVF) of a cryogenic tank with Thermo-dynamic Vent System (TVS) assisted injector, using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. NVF tests were conducted in a CRYOgenic Orbital Testbed (CRYOTE) tank which was filled by liquid nitrogen using a TVS assisted injector with vent valve closed during the entire filling process. In TVS assisted injector, the liquid flow splits into two streams: one stream is routed to a Joule-Thomson (J-T) orifice where the flow immediately flashes from liquid to vapor or two phase mixture because the downstream to J-T leg is maintained at vacuum level.; the other stream is injected into the tank after being cooled by cold vapor of J-T leg in a heat exchanger. The flow through J-T leg is also used to cool the outer metal matrix of the injector which in turn cools the vapor in the tank ullage. The cooling of vapor in the ullage by cold injector surface reduces ullage pressure that allows liquid to enter and fill the tank. An integrated numerical model of the test set up was developed. The model included the dual lines of TVS assisted injector, tank and tank wall. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor at ullage-injector interface and when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall temperature in the tank were compared with the test data.