Search NASA⌕ Search

SEARCH · Search NASA

Results for “fire test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Los Alamos National Laboratory Floodplain Assessment for Fire Risk Mitigations at the Lower Slobbovia Testing Site in (TA-36)

The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing to take fire pre-suppression actions at Los Alamos National Laboratory (LANL) Technical Area (TA) 36. Constructing a fire break and a fuel break surrounding the Lower Slobbovia explosives testing site in addition to the current vegetation mowing practices would establish a safety perimeter to help prevent fires from spreading away from the firing point. NNSA has prepared this floodplain assessment in accordance with 10 Code of Federal Regulations (CFR) Part 1022 Compliance with Floodplain and Wetland Environmental Review Requirements (10 CFR 1022), which was promulgated to implement DOE requirements under Executive Order 11988 Floodplain Management (EO 1977). A floodplain is defined in 10 CFR 1022 as “the lowlands adjoining inland and coastal waters and relatively flat areas and flood prone areas of offshore islands,” and a base floodplain as “the 100-year floodplain, that is, a floodplain with a 1.0 percent chance of flooding in any given year (CFR 2003).” This floodplain assessment evaluates potential impacts to floodplain values and functions from implementation of the proposed action, identifies alternatives to the Proposed Action, and allows for meaningful public comment.

54 ENVIRONMENTAL SCIENCES↗

Fire, insect and disease‐caused tree mortalities increased in forests of greater structural diversity during drought

Abstract Structural diversity is an emerging dimension of biodiversity that accounts for size variations in organs among individuals in a community. Previous studies show significant effects of structural diversity on forest growth, but its effects on forest mortality are not known, particularly at a large scale. To address this knowledge gap, we quantified structural diversity using stem structural diversity (SSD) based on both tree diameter and height. We obtained U.S. Forest Service Forest Inventory and Analysis (FIA) data from over 2400 plots across southcentral U.S. forests that have suffered a recent drought. Using data from multiple sampling times, we calculated SSD and compared the relative importance of SSD, species diversity, functional diversity and other stand attributes in determining tree mortalities caused by fire, insects and diseases. We also used FIRETEC, a physics‐based fire model, to test the effect of SSD on canopy consumption by fire. Our results showed that (1) SSD was positively associated with tree mortalities caused by all three disturbances; (2) species richness was negatively associated with insect‐ and disease‐caused mortalities; (3) functional diversity was negatively associated with fire‐ and disease‐caused mortalities and (4) more phylogenetically related species had more similar mortality rates by insect and disease but not fire. Moreover, the FIRETEC model showed increasing canopy consumption by fire in stands with greater SSD. Together, the different tree mortalities during drought associated with SSD more consistently than the other biodiversity metrics were evaluated. Synthesis . Our results suggest that SSD could be considered in modelling forest dynamics and planning management to sustain forest health under disturbances.

54 ENVIRONMENTAL SCIENCES↗

Development of a Nitrogen and Magnesium Oxide based Class A, B & D Suffocating Fire System (SFSS) for Gloveboxes

Testing related to the development and performance of a “Proof of Concept” Nitrogen/Magnesium Oxide Suffocating Fire System (SFSS) was conducted at Fire and Pump Service Group (FPSG) located in Rancho Dominguez, California. The SFSS Engineering Team (SFSSET), consisting of FPSG and Los Alamos National Laboratory (LANL) personnel researched, developed a prototype, and conducted testing to determine effective means to deliver magnesium oxide (MgO) sand into a glovebox (GB) in a class D fire event. The prototypes development also established the effective coverage area of a magnesium oxide suppression system as well as demonstrated that the GB inert atmosphere could be maintained during and after the release of the MgO sand to control Class A, B and D fires. Previous testing conducted on nitrogen based SFSS provided evidence that the nitrogen based SFSS controlled Class A and B fires (Ralph Clayton, Los Alamos National Laboratory, Brandon Troc and Frank Broidy, Fire and Pump Service Group 2020).Final testing was conducted within a mock GB capable of simulating an inert glovebox atmosphere. Testing demonstrated that the inert atmosphere can be maintained during and after discharge of the MgO sand over a coverage area.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Fire-Induced Pressure Response and Failure Characterization of PCV/SCV/3013 Containers - Phase 3

Several Department of Energy (DOE) facilities have materials stored in robust, welded, stainless - steel containers with presumed fire - induced pressure response behaviors. Lack of test data related to fire exposure requires conservative safety analysis assumptions for container response at these facilities. This conservatism can in turn result in the implementation of challenging operational restrictions with costly nuclear safety controls. To help address this issue for sites that store DOE 3013 stainless - steel containers, a series of ten tests were undertaken at Sandia National Laboratories. The goal of this test series was to obtain the response behavior for various configurations of DOE 3013 containers with various payload compositions when exposed to one of two ASTM fire conditions. Key parameters measured in the test series included identification of failure - specific characteristics such as pressure, temperature, and whether or not a vessel was breached during a test . Numerous failure - specific characteristics were identified from the ten tests. This report describes the implementation and execution of the test series performed to identify these failure - specific characteristics. Discussions on the test configurations, payload compositions, thermal insults, and experimental setups are presented. Test results in terms of pressurization and vessel breach (or no - breach) are presented along with corresponding discussions for each test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Linking habitat suitability with a longleaf pine-hardwood model: Building a species-predictive fire-land management framework

Active management of fire-dependent ecosystems for specific species leads to complex tradeoffs, which affect conservation outcomes to other species. Therefore a multi-species evaluation of management actions is required. Habitat Suitability Models (HSMs) can help in predicting the likelihood of species occurrence using corresponding environmental variables and empirical relationships that link occurrence with specific environmental conditions. Incorporating multiple species into HSMs and relating them to habitat dynamics is crucial for ecosystems that require active management with prescribed fire. To address this issue, we developed multi-species HSM driven within an existing population model of the longleaf pine-hardwood ecosystem to assess the suitability of an ecosystem given different fire management strategies and environmental conditions. The population model used in this study provides spatial and temporal changes of longleaf pine-hardwood habitat structure in response to fire. These habitat values are used by the HSM to calculate habitat suitability for three threatened and endangered faunal species of this ecosystem, which all thrive with frequent fire, but have unique habitat requirements. Transient habitat conditions are traced to predict longleaf pine ecosystem trajectories under various management strategies, thereby evaluating current land management actions, such as thinning or prescribed fire frequencies. We tested a suite of environmental conditions to emphasize the sensitivity of the species to different fire management actions. The results of our modeling suggest that maximum suitable habitat for all three species can be achieved with fire frequency occurring at approximately once every three years. The modeling results support current management actions and provide a new habitat assessment tool that incorporates ecological factors for multiple species, thus providing for habitat optimization.

54 ENVIRONMENTAL SCIENCES↗

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

Dynamic ecosystem assembly and escaping the “fire trap” in the tropics: insights from FATES_15.0.0

Abstract. Fire is a fundamental part of the Earth system, with impacts on vegetation structure, biomass, and community composition, the latter mediated in part via key fire-tolerance traits, such as bark thickness. Due to anthropogenic climate change and land use pressure, fire regimes are changing across the world, and fire risk has already increased across much of the tropics. Projecting the impacts of these changes at global scales requires that we capture the selective force of fire on vegetation distribution through vegetation functional traits and size structure. We have adapted the fire behavior and effects module, SPITFIRE (SPread and InTensity of FIRE), for use with the Functionally Assembled Terrestrial Ecosystem Simulator (FATES), a size-structured vegetation demographic model. We test how climate, fire regime, and fire-tolerance plant traits interact to determine the biogeography of tropical forests and grasslands. We assign different fire-tolerance strategies based on crown, leaf, and bark characteristics, which are key observed fire-tolerance traits across woody plants. For these simulations, three types of vegetation compete for resources: a fire-vulnerable tree with thin bark, a vulnerable deep crown, and fire-intolerant foliage; a fire-tolerant tree with thick bark, a thin crown, and fire-tolerant foliage; and a fire-promoting C4 grass. We explore the model sensitivity to a critical parameter governing fuel moisture and show that drier fuels promote increased burning, an expansion of area for grass and fire-tolerant trees, and a reduction of area for fire-vulnerable trees. This conversion to lower biomass or grass areas with increased fuel drying results in increased fire-burned area and its effects, which could feed back to local climate variables. Simulated size-based fire mortality for trees less than 20 cm in diameter and those with fire-vulnerable traits is higher than that for larger and/or fire-tolerant trees, in agreement with observations. Fire-disturbed forests demonstrate reasonable productivity and capture observed patterns of aboveground biomass in areas dominated by natural vegetation for the recent historical period but have a large bias in less disturbed areas. Though the model predicts a greater extent of burned fraction than observed in areas with grass dominance, the resulting biogeography of fire-tolerant, thick-bark trees and fire-vulnerable, thin-bark trees corresponds to observations across the tropics. In areas with more than 2500 mm of precipitation, simulated fire frequency and burned area are low, with fire intensities below 150 kW m−1, consistent with observed understory fire behavior across the Amazon. Areas drier than this demonstrate fire intensities consistent with those measured in savannas and grasslands, with high values up to 4000 kW m−1. The results support a positive grass–fire feedback across the region and suggest that forests which have existed without frequent burning may be vulnerable at higher fire intensities, which is of greater concern under intensifying climate and land use pressures. The ability of FATES to capture the connection between fire disturbance and plant fire-tolerance strategies in determining biogeography provides a useful tool for assessing the vulnerability and resilience of these critical carbon storage areas under changing conditions across the tropics.

54 ENVIRONMENTAL SCIENCES↗

Files and scripts to support manuscript Shuman et al 2023 FATES-SPITFIRE ecosystem assembly across tropics

The dataset includes the parameter and domain files, relevant output files, and scripts to generate simulations and perform analysis with Jupyter notebooks that support the manuscript Shuman, JK et al 2023 “Dynamic ecosystem assembly and escaping the “fire-trap” in the tropics: Insights from FATES_15.0.0”. We have adapted the fire-behavior and effects module, SPITFIRE, for use with the Functionally Assembled Terrestrial Ecosystem Simulator (FATES), a size-structured vegetation demographic model. We test how climate, fire regime and fire-tolerance plant traits interact to determine the biogeography of tropical forests and grasslands. We assign different fire-tolerance strategies based on crown, leaf and bark characteristics, which are key observed fire-tolerance traits across woody plants. For these simulations, three types of vegetation compete for resources: a fire-vulnerable tree with thin bark, a vulnerable deep crown and fire-intolerant foliage; a fire-tolerant tree with thick bark, a thin crown and fire-tolerant foliage; and a fire-promoting C4 grass. We explore the model sensitivity to a critical parameter governing fuel moisture, and show that drier fuels promote increased burning, an expansion of area for grass and fire-tolerant trees and a reduction of area for fire-vulnerable trees. This conversion to lower biomass or grass areas with increased fuel drying results in increased fire burned area and its effects, which could fee back to local climate variables. Simulated size-based fire mortality for trees less than 20 cm in diameter and those with fire-vulnerable traits is higher than that for larger and/or fire-tolerant trees, in agreement with observations. Fire-disturbed forests demonstrate reasonable productivity and capture observed patterns of aboveground biomass in areas dominated by natural vegetation for the recent historical period, but have a large bias in less disturbed areas. Though the model predicts a greater extent of burned fraction than observed in areas with grass dominance, the resulting biogeography of fire-tolerant, thick-bark trees and fire-vulnerable, thin-bark trees corresponds to observations across the tropics. In areas with more than 2500 mm of precipitation, simulated fire frequency and burned area are low, with fire intensities below 150 kW m-1, consistent with observed understory fire behavior across the Amazon. Areas drier than this demonstrate fire intensities consistent with those measured in savannas and grasslands, with high values up to 4000 kW m-1. The results support a positive grass-fire feedback across the region, and suggest that forests which have existed without frequent burning may be vulnerable at higher fire intensities, which is of greater concern under intensifying climate and land use pressures. The ability of FATES to capture the connection between fire disturbance and plant fire-tolerance strategies in determining biogeography provides a useful tool for assessing the vulnerability and resilience of these critical carbon storage areas under changing conditions across the tropics.

54 ENVIRONMENTAL SCIENCES↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 1: Particulate and gaseous emissions

This study investigated how heat demand and fuel loading affect the emissions from outdoor wood-fired hydronic heaters by testing two such appliances using an integrated-duty cycle test method. This test included transient operating conditions, such as cold and hot-starts and modulation between 15 and 100% of maximum rated output. Emission values indicate transient operating conditions produce higher emissions than steady state operation. Cold starts resulted in elevated particulate matter emission factors for both appliances; in one case the particulate matter emission factor for this period was >3500 mg/MJ, which represented emissions 20 times the average value. Additionally, when heat demand was cycled—elevated CO emission factors were measured, with values >5000 mg/MJ for both appliances and more than 3 times the appliance averages, respectively. It follows that the appliance average particulate matter emission factors and CO emission factors were not representative of the actual EF values during these transient periods. In contrast, methane emission factors were relatively stable throughout all tested combustion conditions; however, they were much higher than oil-fired appliances are therefore should not be ignored. These findings demonstrate that wood-fired hydronic heater emissions during transient operating conditions can be significantly greater than emissions during steady-state test conditions, such as those used in typical certification tests. Consequently, certification test values for particulate matter and CO emission factors may significantly underestimate the actual emissions of these appliances when operated in a home. Use of integrated duty-cycle test protocols that capture cold-starts and reloading are better for representing in-use operations of wood-fired hydronic heaters and provide more realistic emissions and delivered efficiency measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adhesion Capabilities of Permanent Foaming Fixatives

DOE-EM have identified an operational requirement for a fixative that can immobilize and/or encapsulate residual contamination in 3D void volumes (pipes, gloveboxes, waste containers, etc.) during D and D activities. Failure to safely and effectively immobilize residual contamination can: Put workers at risk; Contaminate the public and environment; Drive up costs. Commercial-off-the-shelf (COTS) polyurethane (PU) foams is one possible solution and is currently being investigated by Savannah River National Lab (SRNL). Adhesion testing will dictate how well PU foams will adhere and immobilize residual contamination onto a substrate. Results can provide a performance criteria for Section 5 of ASTM E3191: Standard Specification for Permanent Foaming Fixatives Used to Mitigate Spread of Radioactive Contamination. Initial mechanical testing showed intumescent rigid PU foams were best in class (tensile, compression, TGA/DSC) Application of intumescent rigid PU foam in pipe scenario with 'contamination' showed excellent adhesion capabilities as long as foam had contact with pipe. The foam, however, was not able to penetrate 'contamination' but created pockets where the contamination interacted with the substrate. Pretreatment options of pipe were considered to produce better immobilization capabilities. Pretreatment options included COTS products like baking spray, rubber cement, and soap. Foam was still able to immobilize on a global sense, but not a local sense. Essentially acted as a mechanical plug. A tensile tester (MTS Criterion Series 43) was utilized to evaluate the tensile adhesion strength of 6 COTS PU foams. ASTM D1623: Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics. Procedures: PU foams were cured between two smooth 2'' x 2'' 304 stainless steel coupons with hinges glued on plates for gripping support. Parameters Used: Pull rate of 0.1 in/min. Calculations: Tensile adhesion strength, elongation, and ImageJ analysis of how PU foam is left on substrate. Outcome: The PU foam with the best adhesion capabilities would be downselected for further evaluation to be used as a permanent foaming fixative. The rigid PU foams had the best adhesion capabilities with the R1 foam having a max load of 236 N. One of the I-R2 samples reached almost 450 N and another sample reached 2500 N before slipping. The other intumescent foam, I-F4, had the most coverage on the stainless steel coupon's surface from the ImageJ results (61.43% surface coverage). The intumescent foam, I-R2, will be the foam of choice for future testing due its fire retardant and adhesion capabilities. Future directions: Conduct the following experiment in a pipe scenario with the down-selected PU foam. Procedures: PU foam will be cured between in a 304 stainless steel pipe (ID: 4'', OD: 4.5'', Height: 4''). Parameters Used: Compression testing results will be referenced to determine if foam's adhesion strength would be greater its compression strength as its being compressed. Calculations: Compression strength, shear stress, total time elapsed. Conduct further adhesion testing with the down-selected PU foam (I-R2) to be treated as a permanent foaming fixative (PFF). Determine the minimum contact the PFF should have with the substrate for adequate results. Evaluate if PFF's adhesion capabilities is time dependent (3.1.5 of ASTM E3911). Subject PFF to seismic stressors addressed in Safety Basis of Interim Operation documents (SBIO) to further evaluate adhesion capabilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LA-R43S6-L1 Postshot Report [Slides]

The Ranchero LA-R43S6-L1 test (formerly referred to as LA-43S-L1. The R specifically designates it is a Ranchero device and the 6 indicates a 6” high explosive charge diameter in anticipation of using larger diameters in the future.) was conducted on 3/8/17 with good success. The experiment was the first test of a “Swooped” Ranchero flux compression generator (FCG), and the load for the test was an aluminum imploding liner. In addition to the swoop, the stator was anodized to provide an insulating layer instead of one or more layers of polyethylene as had been the case for all earlier Ranchero tests. Using the Firing point TA-39-88 capacitor bank, 3.5 MA was delivered to the FCG for the initial magnetic field, and 36.4 MA were delivered to the load having an initial inductance of 2.5 nH. Implosion speeds over 1.1 cm/us were recorded, which exceeds previous LANL solid liner experimental results. The test was diagnosed with 18 PDV channels, 12 of which recorded liner implosion data, and the other 6 of which tracked the FCG armature during flux compression. These armature expansion data recorded during flux compression are the first of their kind, and it was previously unknown, due to unknown effects of the SF 6 in the flux compression volume, whether or not the expansion could be recorded using the PDV technique. Post shot 2D MHD calculations employed a complete external circuit model, and an improved flux diffusion model not available prior to the test. Results from these simulations show very good agreement with the experimental result. Four PDV channels recorded the liner implosion viewed radially outward from the center of the liner. All four of these probes recorded implosion velocities greater that 1 cm/µs, with the cylindrical center displaced by ~2 mm from actual center. Four PDV channels looked at +10° angles from the CMU wall, and four looked at -10° angles. A glide plane interaction is shown moving toward the center of the liner in MHD calculations, and PDV probes provide confirmation. The high explosive (HE) in the LA-R43S6-L1 test was PBX 9501 which had to be glued together in many pieces, and the test was preceded by a camera test to verify that the PBX 9501 could be assembled with acceptable tolerance in glue joints to prevent severing the armature during expansion. The camera test verified an acceptable armature performance, and results are given in complete detail in a post shot report LA-UR-19-20124, and summarized here. This report provides complete detail of the considerable body of data obtained on the test and in the post shot calculations. It is prepared in Power Point for ease of preparation and future review. Shot documentation available in the LANL on-line library are included as references, and non-referenceable documents will be cited and stored in an LA- R43S6-L1 post shot folder stored on an M-6 shared drive. Fabrication drawings are also maintained in an M-6 shared drive and paper files are available from M-6 personnel. This report will be maintained as a PowerPoint document on the shared drive, as well, since included movies will play and graphs from Excel files retain information in the PowerPoint versions. PDF versions are required for clearance and are not to large to send by e-mail.

42 ENGINEERING↗

Stellar Mass Calibrations for Local Low-mass Galaxies

The stellar masses of galaxies are measured from integrated light via several methods—however, few of these methods were designed for low-mass (M ⋆ ≲ 10 8 M ⊙ ) “dwarf” galaxies, whose properties (e.g., stochastic star formation, low metallicity) pose unique challenges for estimating stellar masses. In this work, we quantify the precision and accuracy at which stellar masses of low-mass galaxies can be recovered using UV/optical/IR photometry. We use mock observations of 469 low-mass galaxies from a variety of models, including both semi-empirical models (GRUMPY and UniverseMachine-SAGA) and cosmological baryonic zoom-in simulations (MARVELous Dwarfs and FIRE-2), to test literature color–M ⋆ /L relations and multiwavelength spectral energy distribution (SED) mass estimators. We identify a list of “best practices” for measuring stellar masses of low-mass galaxies from integrated photometry. We find that literature color–M ⋆ /L relations are often unable to capture the bursty star formation histories (SFHs) of low-mass galaxies, and we develop an updated prescription for stellar mass based on g − r color that is better able to recover stellar masses for the bursty low-mass galaxies in our sample (with ∼0.1 dex precision). SED fitting can also precisely recover stellar masses of low-mass galaxies, but this requires thoughtful choices about the form of the assumed SFH: Parametric SFHs can underestimate stellar mass by as much as ∼0.4 dex, while nonparametric SFHs recover true stellar masses with insignificant offset (−0.03 ± 0.11 dex). Finally, we also caution that noninformative (wide) dust attenuation priors may introduce M ⋆ uncertainties of up to ∼0.6 dex.

de los Reyes, Mithi A. C. [Amherst College, MA (Un↗

Testing- and Model- Based Optimization of Coal-fired Primary Heater Design for Indirect Supercritical CO 2 Power Cycles (Final Scientific and Technical Report)

The overall objective of this project was to perform the R&D necessary to mitigate the risk associated with the design of a primary heat exchanger for a solid-fired combustion system coupled with an indirect-fired closed-loop Brayton Cycle utilizing supercritical CO 2 . The key technological hurdle was the coupling of a solid-fuel firing system with the primary heater, which poses a singular challenge, which is the management of burner performance and operational conditions in a way to manage heat exchanger tube metal temperatures and temperature ramp rates in the absence of fluid phase change on the inside of the tubes. We designed and built the first ever pseudo power system employing a simple recuperated supercritical CO 2 closed-loop Brayton Cycle coupled to a solid-fuel fired system. Advanced coupled CFD and process modeling were used to design the primary heat exchanger (PHX), which consisted of both radiative and convective sections, to limit tube metal temperatures resulting from the heat release profile of the solid fuel flame near the radiative tubes. The heat exchanger was designed to produce finished CO 2 temperatures of 600 °C a pressure of 20.7 MPa and CO 2 flow of 5.5 kg/s. The constructed PHX was capable of 1.2 MWth heat uptake. During design of the PHX, the modeling showed that most variables influencing flame shape (burner stoichiometric ratio and register velocities and swirl) were not suitable to manage heat flux to the metal surfaces. This is because they substantially increased adiabatic flame temperature through the influence of localized stoichiometric ratio. Excess air and firing rate were the two most powerful variables that could be used to control tube surface temperatures. The coupled system was operated for a total of 407 hours, with the longest continuous run of 248 hours. For 62% of the operational time, the unit was unmanned and in automatic control. The fuels used for the testing included natural gas, two Utah Bituminous coals, woody biomass, and bagasse. During the testing we were able to verify the 1.2 MWth heat uptake and we operated at a finished CO 2 temperature of 607 °C and a pressure of 20.3 MPa simultaneously. The real-time corrosion rate of the Super 304H tube CO 2 surface in the region of the radiative section of the PHX were measured, at an approximate temperature of 550 °C. The two key variables related to corrosion rate are the pressure and flow rate of the CO 2 . A technoeconomic analysis was performed at a scale of 120 MWE. The updated analysis showed that the efficiency of an sCO 2 power producing plant will be related to the pressure drop of the PHX.

01 COAL, LIGNITE, AND PEAT↗

NFPA Distributed Energy Resources Safety Training (DERST) For Emergency Responders

The National Fire Protection Association, with support from the Department of Energy, executed a multi-year initiative to develop, enhance, and disseminate Distributed Energy Resources Safety Training (DERST) tools for U.S. emergency responders. As Distributed Energy Resources (DER)—such as solar photovoltaics, battery energy storage systems (ESS), electric vehicles (EVs), and associated infrastructure—become increasingly prevalent, the NFPA identified a critical need for up-to-date standardized, accessible, and effective safety training tailored for the fire service and related public safety professionals. The project delivered a comprehensive suite of educational resources to improve responders’ abilities to safely manage DER-related incidents. This included: • Revised Modular Training Courses: Updated classroom-based DER safety courses, now modular and accessible nationwide through fire academies and the North American Fire Training Directors (NAFTD) network. • Live Burn Testing & Research: A full-scale controlled burn of a DER-equipped residential structure provided real-world data and insights, forming the basis for updated best practices. • A Gamified Simulation Tool – Firefighters Incident Response Simulation Tool (FIRST): A first-of-its-kind, multiplayer, scenario-based simulation using the Unreal Engine 5.0 to train responders in a realistic virtual, multi-DER incident environment. • Field Familiarization Software Tools & Prop Guide: Digital DER field familiarization evolutions software guide and a prop development manual to support field-based DER training exercises, enhancing responders' hands-on familiarity with DER infrastructure and collaboration on virtual incident responses. • National Dissemination Strategy: Strategic partnerships with NAFTD, Vector Solutions, and others enabled wide-scale distribution, with over 5,000 departments accessing resources and 1,100+ departments adopting the simulator in the first seven months. Also provided a web portal for easy access to all training and simulation programs developed under this grant for the U.S. responder community. Key findings from the project—particularly from the burn test—led to paradigm shifts in fire response tactics. For example, traditional approaches to garage fires may be hazardous if DERs are present, due to explosive off gassing and thermal runaway risks. The new training emphasizes scene assessment, stand-off approaches, thermal imaging verification, and careful post-incident cooling of DER components to prevent reignition. This initiative has had a significant national impact, raising awareness, enhancing preparedness, and supporting safer DER incident response practices. Significant engagement from the media, public safety organizations, and PBS coverage has further amplified the reach and adoption of NFPA’s DER safety training, tools, and simulations.

14 SOLAR ENERGY↗

Acoustics Examination of Kappa West Firing ARMAG for Personnel Occupancy

In April of 2023, LANL conducted a series of explosive tests at the Kappa West firing mound at BEEF, NNSS, to examine noise levels within the diagnostics ARMAG next to the firing mound. The intent was to establish an explosive mass that could be detonated on the mound without generating blast noise inside the ARMAG which would be unsafe for personnel. The blast noise threshold for personnel safety during intentional firing operations is 140 dB. Based on data collected during prior experiments, it was anticipated that the noise levels inside the ARMAG would be 20-30 dB lower than noise levels outside the ARMAG. However, data from prior experiments were collected from charges that were not consistent geometries and test layouts, so it was unknown what quantity of explosive would generate the threshold noise level. A prediction was made using the BEC-O standard blast calculator from the DDESB, from which it was estimated that a single, consolidated 60-pound charge at 180 feet would generate blast noise levels of about 170 dB, with noise levels falling to a predicted 166 dB at 250 feet.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Pilot Testing of Amine-Based Solvent at Low-Rank Coal Fired Power System

Conference presentation for the 2023 International Freiberg Conference on Circular Carbon Technologies, Rotterdam, Netherlands, September 24–29, 2023. This presentation describes pilot testing of an amine-based CO₂ capture system at Coal Creek Station, examining solvent performance, system design, and operating conditions for a low-rank coal-fired power plant. The Mitsubishi Heavy Industries KM CDR (KS-1) process is assessed using pilot-scale data to inform capture efficiency, solvent condition, and integration considerations.

01 COAL, LIGNITE, AND PEAT↗

Mitigation for roof alterations to building 06-cp-65 at the area 6 control point, nevada national security site, nye county, nevada

Building 06-CP-65 has been determined to be a contributing element to the Area 6 Control Point Historic District (O’Neill et al. 2021; Reed 2022). It contributes to the significance of the historic district under Criterion A as one of the principal buildings that supported timing and firing operations for nuclear testing on the NNSS from 1966 to 1992. As such, the building served as a major warehouse with office space within the district. It was used by both REECo, a long-time general contractor at the NNSS, as well as EG&G, which provided technical support to the national laboratories and the DOD. The building served as an important staging area and electrical power supply point for the NNSS diagnostic trailer fleet and its unique location immediately along Mercury Highway allowed easy accessibility to the forward areas of the NNSS. The building also contributes to the historic district under Criterion C as it is one of the large, unadorned, precast concrete buildings at the Control Point. These types of buildings were the prominent elements of the compound that convey the district’s overall utilitarian, military-industrial character. Building 06-CP-65 retains all aspects of integrity to a high degree and easily conveys its significance as a warehouse that supported Control Point operations. Building 06-CP-65 is not recommended eligible for listing in the NRHP as an individual resource. While it served an important support function as part of the Control Point Historic District, an archival and literature review did not reveal information linking it to any specific test, series of tests, programs, or for any specific role on the NNSS other than as a warehouse (Criterion A). It has no direct association with any important individual (Criterion B). It also is not architecturally significant in its own right beyond reflecting the overall aesthetic of the Control Point Historic District (Criterion C), and it does not have potential to yield information important to the history of nuclear testing beyond what can be learned from historic texts, drawings, and other documents (Criterion D).

54 ENVIRONMENTAL SCIENCES↗