Search NASA⌕ Search

SEARCH · Search NASA

Results for “fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Approach to fitting parameters and clustering for characterising measured voltage dips based on two-dimensional polarisation ellipses

An alternative approach to characterise real voltage dips is proposed and evaluated in this study. The proposed methodology is based on voltage-space vector solutions, identifying parameters for ellipses trajectories by using the least-squares algorithm applied on a sliding window along the disturbance. The most likely patterns are then estimated through a clustering process based on the k-means algorithm. The objective is to offer an efficient and easily implemented alternative to characterise faults and visualise the most likely instantaneous phase-voltage evolution during events through their corresponding voltage-space vector trajectories. This novel solution minimises the data to be stored but maintains extensive information about the dips including starting and ending transients. The proposed methodology has been applied satisfactorily to real voltage dips obtained from intensive field-measurement campaigns carried out in a Spanish wind power plant up to a time period of several years. A comparison to traditional minimum root mean square-voltage and time-duration classifications is also included in this study.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automated Resonance Fitting for Nuclear Data Evaluation

Global and national efforts to deliver high-quality nuclear data to users have a wide-ranging impact, affecting applications in national security, reactor operations, basic science, medicine, and more. Cross section evaluation is a major part of this effort, combining theory and experimentation to produce recommended values and uncertainties for reaction probabilities. Resonance region evaluation is a specialized type of nuclear data evaluation that can require significant manual effort and months of time from expert scientists. In this article, non-convex non-linear optimization methods are combined with concepts of inferential statistics to infer a resonance model from experimental data in an automated manner that is not dependent on prior evaluation(s). This methodology aims to enhance the workflow of a resonance evaluator by minimizing time, effort, and the potential for bias from prior assumptions, while enhancing reproducibility and documentation, thereby addressing well-known challenges in the field.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Practical applications of the sigma factor alarm method within alpha CAMs utilizing either ROI, tail-fitting, or peak-fitting algorithms

Some test must be applied to the low-level count data from alpha continuous air monitors (CAMs) to determine if the count is statistically significant (i.e., significantly above background). The test should also automatically account for different levels of background (i.e., different ambient radon progeny concentrations). In other words, the method should be as sensitive as possible, automatically desensitizing when required, yet in such a manner as to not exceed some previously-chosen acceptable false-alarm rate. The test that has been historically utilized within many alpha CAMs to accomplish these goals is the so-called sigma factor approach.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Combined Effect of Cigarette Smoking and Fitness on Injury Risk in Men and Women

Abstract Background Prior studies have identified cigarette smoking and low fitness as independent risk factors for injury; however, no studies have evaluated the combined effect of cigarette smoking and fitness on injury risk. Objective To evaluate the combined effect of cigarette smoking and fitness on injury risk in men and women. Design This is a secondary analysis of data collected from US Army recruits (n = 2000) during basic combat training within the United States in 2007. Physical training and fitness, cigarette smoking, and prior injury data were obtained from questionnaires, whereas demographic and injury data were obtained from medical and basic combat training unit records. Chi-squared tests were used to assess differences in injury risk by fitness level and cigarette smoking. Relative risk values were calculated with 95% confidence intervals. Results The primary findings showed that smokers experienced 20%–30% higher risk of injury than nonsmokers. In addition, higher aerobic and muscular fitness was generally not protective against injury between least fit and more fit smokers. However, higher fitness was protective against injury between least and more fit nonsmokers, with least fit nonsmokers being 30%–50% more likely to experience an injury than fit nonsmokers. Conclusion This study revealed that higher aerobic and muscular fitness was not protective against injury among smokers; however, it was protective against injury among nonsmokers. Further implementation of smoking cessation programs may be beneficial for military and civilian personnel who are required to be physically fit in order to carry out their job responsibilities. Implications Male and female smokers experienced significantly higher risk of injury than nonsmokers. Although higher fitness is protective against injury in nonsmokers, the protective effect of fitness is lost among smokers. In an attempt to reduce injury risk among military and emergency personnel, smoking cessation programs should be further implemented among both more fit and less fit smokers.

Brooks, Raina D.↗

Assessing methods in fusion and fitting for time series construction in remote sensing-based earth observations

This study evaluates the comparative performance of spatiotemporal fusion and time-series fitting methods for constructing high-spatiotemporal-resolution remote sensing time-series data. Due to in-class similarity of fusion methods and fitting methods, we employ the Fit-FC (Fitting, spatial Filtering, and residual Compensation) model as a representative fusion method and the linear harmonic fitting model as a representative fitting method. Both Fit-FC and the linear harmonic fitting are widely used for high-spatiotemporal-resolution time-series data construction, and we modify the original Fit-FC model to enable automatic time-series fusion. To ensure data representativeness, we use 3 years (2019–2021) of Harmonized Landsat and Sentinel-2 surface reflectance datasets and Terra MCD43A4 products. Eight experimental regions are selected worldwide to guarantee generalization of the comparative performance between fusion and fitting methods, covering diverse land-use types (cropland, developed land, forest, and grassland) and varying climatological conditions. Time-series of NDVI and surface reflectance are analyzed under both actual observations and simulated data-missing scenarios. The constructed time-series data reveals that (1) the modified Fit-FC and linear harmonic fitting model achieve excellent performance in constructing high-resolution time-series images; (2) the fusion method outperforms the fitting method in constructing time-series of NDVI and surface reflectance images in cropland-, forest-, and grassland-dominated regions; (3) both methods achieve comparable performance in developed-dominated regions; (4) the fusion method is more robust to missing data, and better captures abrupt phenological transitions under conditions of continuous missing data; (5) the fitting method is computationally more efficient, making it suitable for large-scale time-series image reconstruction. This study provides valuable insights for selecting optimal strategies to generate high-resolution time-series images across diverse application scenarios and lays a foundation for extensions to other vegetation indices or land surface variables.

54 ENVIRONMENTAL SCIENCES↗

LOCO with Constraints and Improved Fitting Technique

LOCO has been a powerful beam-based diagnostics and optics control method for storage rings and synchrotrons worldwide ever since it was established at NSLS by J. Safranek. This method measures the orbit response matrix and optionally the dispersion function of the machine. The data are then fitted to a lattice model by adjusting parameters such as quadrupole and skew quadrupole strengths in the model, BPM gains and rolls, corrector gains and rolls of the measurement system. Any abnormality of the machine that affects the machine optics can then be identified. The resulting lattice model is equivalent to the real machine lattice as seen by the BPMs. Since there are usually two or more BPMs per betatron period in modern circular accelerators, the model is often a very accurate representation of the real machine. According to the fitting result, one can correct the machine lattice to the design lattice by changing the quadrupole and skew quadrupole strengths. LOCO is so important that it is routinely performed at many electron storage rings to guarantee machine performance, especially after the Matlab-based LOCO code became available. However, for some machines, LOCO is not easy to carry out. In some cases, LOCO fitting converges to an unrealistic solution with large changes to the quadrupole strengths {Delta}K. The quadrupole gradient changes can be so large that the resulting lattice model fails to find a closed orbit and subsequent iterations become impossible. In cases when LOCO converges, the solution can have {Delta}K that is larger than realistic and often along with a spurious zigzag pattern between adjacent quadrupoles. This degeneracy behavior of LOCO is due to the correlation between the fitting parameters - usually between neighboring quadrupoles. The fitting scheme is therefore less restrictive over certain patterns of changes to these quadrupoles with which the correlated quadrupoles fight each other and the net effect is very inefficient {chi}{sup 2} reduction, i.e., small {chi}{sup 2} reduction with large changes of {Delta}K. Under effects of random noise, the fitting solution tends to crawl toward these patterns and ends up with unrealistically large {Delta}K. Such a solution is not very useful in optics correction because after the solution is dialed in, the quadrupoles will not respond as predicted by the lattice model due to magnet hysteresis. We will show that adding constraints to the fitting parameters is an effective way to combat this problem of LOCO. In fact, it improves optics calibration precision even for machines that don't show severe degeneracy behavior. LOCO fitting is essentially to solve a nonlinear least square problem with an iterative approach. The linear least square technique is applied in each iteration to move the solution toward the minimum. This approach is commonly referred to as the Gauss-Newton method. By using singular value decomposition (SVD) to invert the Jacobian matrix, this method has generally been very successful for LOCO. However, this method is based on a linear expansion of the residual vector over the fitting parameters which is valid only when the starting solution is sufficiently close to the real minimum. The fitting algorithm can have difficulties to converge when the initial guess is too far off. For example, it's possible for the {chi}{sup 2} merit function to increase after an iteration instead of decrease. This situation can be improved by using more robust nonlinear least square fitting algorithms, such as the Levenberg-Marquardt method. We will discuss the degeneracy problem in section 2 and then show how the constrained fitting can help in section 3. The application of Levenberg-Marquadt method to LOCO is shown in section 4. A summary is given in section 5.

43 PARTICLE ACCELERATORS↗

Preexisting compensatory amino acids compromise fitness costs of a HIV-1 T cell escape mutation

Background: Fitness costs and slower disease progression are associated with a cytolytic T lymphocyte (CTL) escape mutation T242N in Gag in HIV-1-infected individuals carrying HLA-B*57/5801 alleles. However, the impact of different context in diverse HIV-1 strains on the fitness costs due to the T242N mutation has not been well characterized. To better understand the extent of fitness costs of the T242N mutation and the repair of fitness loss through compensatory amino acids, we investigated its fitness impact in different transmitted/founder (T/F) viruses. Results: The T242N mutation resulted in various levels of fitness loss in four different T/F viruses. However, the fitness costs were significantly compromised by preexisting compensatory amino acids in (Isoleucine at position 247) or outside (glutamine at position 219) the CTL epitope. Moreover, the transmitted T242N escape mutant in subject CH131 was as fit as the revertant N242T mutant and the elimination of the compensatory amino acid I247 in the T/F viral genome resulted in significant fitness cost, suggesting the fitness loss caused by the T242N mutation had been fully repaired in the donor at transmission. Analysis of the global circulating HIV-1 sequences in the Los Alamos HIV Sequence Database showed a high prevalence of compensatory amino acids for the T242N mutation and other T cell escape mutations. Conclusions: Our results show that the preexisting compensatory amino acids in the majority of circulating HIV-1 strains could significantly compromise the fitness loss due to CTL escape mutations and thus increase challenges for T cell based vaccines.

59 BASIC BIOLOGICAL SCIENCES↗

Mouse fat storage‐inducing transmembrane protein 2 ( FIT 2) promotes lipid droplet accumulation in plants

Summary Fat storage‐inducing transmembrane protein 2 ( FIT 2) is an endoplasmic reticulum ( ER )‐localized protein that plays an important role in lipid droplet ( LD ) formation in animal cells. However, no obvious homologue of FIT 2 is found in plants. Here, we tested the function of FIT 2 in plant cells by ectopically expressing mouse ( Mus musculus ) FIT 2 in Nicotiana tabacum suspension‐cultured cells, Nicotiana benthamiana leaves and Arabidopsis thaliana plants. Confocal microscopy indicated that the expression of FIT 2 dramatically increased the number and size of LD s in leaves of N. benthamiana and Arabidopsis, and lipidomics analysis and mass spectrometry imaging confirmed the accumulation of neutral lipids in leaves. FIT 2 also increased seed oil content by ~13% in some stable, overexpressing lines of Arabidopsis . When expressed transiently in leaves of N. benthamiana or suspension cells of N. tabacum , FIT 2 localized specifically to the ER and was often concentrated at certain regions of the ER that resembled ER ‐ LD junction sites. FIT 2 also colocalized at the ER with other proteins known to be involved in triacylglycerol biosynthesis or LD formation in plants, but not with ER resident proteins involved in electron transfer or ER ‐vesicle exit sites. Collectively, these results demonstrate that mouse FIT 2 promotes LD accumulation in plants, a surprising functional conservation in the context of a plant cell given the apparent lack of FIT 2 homologues in higher plants. These results suggest also that FIT 2 expression represents an effective synthetic biology strategy for elaborating neutral lipid compartments in plant tissues for potential biofuel or bioproduct purposes.

59 BASIC BIOLOGICAL SCIENCES↗

Efficient scatter distribution estimation and correction in CBCT using concurrent Monte Carlo fitting

Purpose: X-ray scatter is a significant impediment to image quality improvements in cone-beam CT (CBCT). The authors present and demonstrate a novel scatter correction algorithm using a scatter estimation method that simultaneously combines multiple Monte Carlo (MC) CBCT simulations through the use of a concurrently evaluated fitting function, referred to as concurrent MC fitting (CMCF). Methods: The CMCF method uses concurrently run MC CBCT scatter projection simulations that are a subset of the projection angles used in the projection set, P, to be corrected. The scattered photons reaching the detector in each MC simulation are simultaneously aggregated by an algorithm which computes the scatter detector response, S{sub MC}. S{sub MC} is fit to a function, S{sub F}, and if the fit of S{sub F} is within a specified goodness of fit (GOF), the simulations are terminated. The fit, S{sub F}, is then used to interpolate the scatter distribution over all pixel locations for every projection angle in the set P. The CMCF algorithm was tested using a frequency limited sum of sines and cosines as the fitting function on both simulated and measured data. The simulated data consisted of an anthropomorphic head and a pelvis phantom created from CT data, simulated with and without the use of a compensator. The measured data were a pelvis scan of a phantom and patient taken on an Elekta Synergy platform. The simulated data were used to evaluate various GOF metrics as well as determine a suitable fitness value. The simulated data were also used to quantitatively evaluate the image quality improvements provided by the CMCF method. A qualitative analysis was performed on the measured data by comparing the CMCF scatter corrected reconstruction to the original uncorrected and corrected by a constant scatter correction reconstruction, as well as a reconstruction created using a set of projections taken with a small cone angle. Results: Pearson’s correlation, r, proved to be a suitable GOF metric with strong correlation with the actual error of the scatter fit, S{sub F}. Fitting the scatter distribution to a limited sum of sine and cosine functions using a low-pass filtered fast Fourier transform provided a computationally efficient and accurate fit. The CMCF algorithm reduces the number of photon histories required by over four orders of magnitude. The simulated experiments showed that using a compensator reduced the computational time by a factor between 1.5 and 1.75. The scatter estimates for the simulated and measured data were computed between 35–93 s and 114–122 s, respectively, using 16 Intel Xeon cores (3.0 GHz). The CMCF scatter correction improved the contrast-to-noise ratio by 10%–50% and reduced the reconstruction error to under 3% for the simulated phantoms. Conclusions: The novel CMCF algorithm significantly reduces the computation time required to estimate the scatter distribution by reducing the statistical noise in the MC scatter estimate and limiting the number of projection angles that must be simulated. Using the scatter estimate provided by the CMCF algorithm to correct both simulated and real projection data showed improved reconstruction image quality.

60 APPLIED LIFE SCIENCES↗

MITR DDE End Fitting Structural Rigidity Analysis

As a part of the design of the MITR Design Demonstration Element (DDE), a new design for the end fittings must be considered to meet specific experiment needs, e.g., compatibility with the geometrical restrictions of the DDE testing location (BR2 test reactor located in Mol, Belgium), and to allow for proper inspection of these test elements during the experiments. The design of the MITR DDE end fittings is substantially different from the design of the end fittings of the MITR LEU fuel elements, with the DDE end fittings considerably smaller in overall size and weight. Consequently, the stiffness of the end fittings as well as of the entire fuel element is affected. The end fittings in the MITR LEU fuel element are designed primarily for proper handling and flow distribution. The stiffness of the end fittings also constitutes a fraction of the total stiffness of the entire fuel element. It is debatable to what extent the end fittings provide the structural rigidity necessary for the fuel element to properly respond to potential loadings. It is presumed that the bulk of the overall stiffness of the element is derived from swaging multiple fuel plates into the side plates. However, the contribution of stiffness from various components of the MITR LEU fuel element and MITR DDE has not been determined so far. The primary objective of the work presented in this report was to assess the extent to which the stiffness of the end fitting in the MITR DDE contributes to the stiffness of the entire fuel element, and how it compares to the equivalent stiffness of the end fitting in the MITR LEU fuel element. Several simplified load cases were analyzed for that purpose using the geometries of the MITR LEU fuel element, MITR DDE, as well as that of the MITR DDE without the top end fitting.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Predictive models of the genetic bases underlying budding yeast fitness in multiple environments

Abstract The ability of organisms to adapt and survive depends on the effects of genes and the environment on fitness. However, the multigenic nature of fitness and genotype-by-environment interactions hinder our understanding of the genetic basis of fitness. Here, we established fitness prediction models for 35 environments using machine learning and existing fitness data and different genetic variant types for a Saccharomyces cerevisiae population. Models revealed that the predictive ability of genetic variants varied across environments, with copy number variants explaining the majority of fitness variation in most cases. Model interpretation showed that different variant types identified distinct gene sets associated with predictive variants. These gene sets were significantly enriched in experimentally validated genes affecting fitness in only a subset of environments, indicating that many genes influencing fitness remain unexplored. Notably, non-experimentally validated genes were more important than validated ones for fitness predictions. Gene contributions to predictions were both isolate- and environment-dependent, pointing to gene-by-gene and gene-by-environment interactions. Furthermore, models uncovered experimentally validated and novel candidate genetic interactions for a well-characterized stress, the fungicide benomyl. These findings highlight the feasibility of identifying the genetic basis of fitness by using different genetic variant types and offer novel targets for future functional analysis.

DNA copy number variations↗

Impact of immune escape mutations on HIV-1 fitness in the context of the cognate transmitted/founder genome

Background: A modest change in HIV-1 fitness can have a significant impact on viral quasispecies evolution and viral pathogenesis, transmission and disease progression. To determine the impact of immune escape mutations selected by cytotoxic T lymphocytes (CTL) on viral fitness in the context of the cognate transmitted/founder (T/F) genome, we developed a new competitive fitness assay using molecular clones of T/F genomes lacking exogenous genetic markers and a highly sensitive and precise parallel allele-specific sequencing (PASS) method. Results: The T/F and mutant viruses were competed in CD4+ T-cell enriched cultures, relative proportions of viruses were assayed after repeated cell-free passage, and fitness costs were estimated by mathematical modeling. Naturally occurring HLA B57-restricted mutations involving the TW10 epitope in Gag and two epitopes in Tat/Rev and Env were assessed independently and together. Compensatory mutations which restored viral replication fitness were also assessed. A principal TW10 escape mutation, T242N, led to a 42% reduction in replication fitness but V247I and G248A mutations in the same epitope restored fitness to wild-type levels. No fitness difference was observed between the T/F and a naturally selected variant carrying the early CTL escape mutation (R355K) in Env and a reversion mutation in the Tat/Rev overlapping region. Conclusions: These findings reveal a broad spectrum of fitness costs to CTL escape mutations in T/F viral genomes, similar to recent findings reported for neutralizing antibody escape mutations, and highlight the extraordinary plasticity and adaptive potential of the HIV-1 genome. Analysis of T/F genomes and their evolved progeny is a powerful approach for assessing the impact of composite mutational events on viral fitness.

Transmitted/founder virus↗

SU-E-J-85: Leave-One-Out Perturbation (LOOP) Fitting Algorithm for Absolute Dose Film Calibration

Purpose: To introduce an outliers-recognition fitting routine for film dosimetry. It cannot only be flexible with any linear and non-linear regression but also can provide information for the minimal number of sampling points, critical sampling distributions and evaluating analytical functions for absolute film-dose calibration. Methods: The technique, leave-one-out (LOO) cross validation, is often used for statistical analyses on model performance. We used LOO analyses with perturbed bootstrap fitting called leave-one-out perturbation (LOOP) for film-dose calibration . Given a threshold, the LOO process detects unfit points (“outliers”) compared to other cohorts, and a bootstrap fitting process follows to seek any possibilities of using perturbations for further improvement. After that outliers were reconfirmed by a traditional t-test statistics and eliminated, then another LOOP feedback resulted in the final. An over-sampled film-dose- calibration dataset was collected as a reference (dose range: 0-800cGy), and various simulated conditions for outliers and sampling distributions were derived from the reference. Comparisons over the various conditions were made, and the performance of fitting functions, polynomial and rational functions, were evaluated. Results: (1) LOOP can prove its sensitive outlier-recognition by its statistical correlation to an exceptional better goodness-of-fit as outliers being left-out. (2) With sufficient statistical information, the LOOP can correct outliers under some low-sampling conditions that other “robust fits”, e.g. Least Absolute Residuals, cannot. (3) Complete cross-validated analyses of LOOP indicate that the function of rational type demonstrates a much superior performance compared to the polynomial. Even with 5 data points including one outlier, using LOOP with rational function can restore more than a 95% value back to its reference values, while the polynomial fitting completely failed under the same conditions. Conclusion: LOOP can cooperate with any fitting routine functioning as a “robust fit”. In addition, it can be set as a benchmark for film-dose calibration fitting performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗