At least 55 records · Page 3

Calculation of surface current response to surface flashover of a large sample under grounded and floating conditions

Results for the electromagnetic response to the discharge of an 80 cm diameter dielectric sample mounted on a 120 cm diameter cylinder are presented. It is assumed that the dielectric is charged with a known potential profile dropping sharply near the edge, and the substrate initially grounded. During the early part of the discharge (approximately 10 ns) there is little difference between the grounded and floating cases. Beyond about 10 ns the grounded experiment is in approximate steady state, continuous to blow off charge until the dielectric is substantially discharged. The floating case, however, shows modestly decreasing emission and response. Eventually, a quasi-steady state is reached in which charge is transported from dielectric to substrate rather than blown off.

Mandell, M. J.↗

Surface flashover arc orientation on Mylar film

A study of the arc discharge patterns and resultant damage patterns on thin Mylar films exposed to a 20 keV electron beam is described. In particular, it is established that there is a broad directional correlation among the directions associated with visible linear arcs, damage tracks, the 'slow' optical direction and the longitudinal marks left on the films surface as a result of chemical etching. Transverse etch marks also appear to be associated with secondary groups of damage track directions. The 'fast' optical direction is associated with the absence of visible arcs or arc damage.

Gossland, M.↗

Barriers to flashover discharge arcs on Teflon

The effect of various barriers (empty gap, copper, Mylar, and nickel mesh) on the probability of simultaneous arc discharging of two physically separated pieces of electron-beam-charged Teflon was studied. For the empty gap barrier, it was found that simultaneous discharges rarely occur when the separation between the samples is greater than approximately 0.4 times the length of their common edge when this length is of the order of 1 cm. Evidence suggests that electromagnetic fields play a larger role than electrons in influencing the occurrence of simultaneous arc discharges.

Gossland, M.↗

Abstract for CRADA between NETL and Electric Power Research Institute (EPRI) (AGMT-1113)

The National Energy Technology Laboratory (NETL) and EPRI (Participant) will collaborate in the investigation of flashovers in electric power distribution maintenance operations. Live line and barehand maintenance techniques are used on overhead transmission lines around the world. While flashovers during this type of work are rare, several unexplained flashovers have occurred in North America. In each case, available evidence suggests these occurred at steady state (60 Hz) system voltage and at voltage stress levels well below that which is known to cause flashover. Understanding the cause of these flashovers is essential so they can be avoided in the future and enhance line worker safety. Some utilities are considering adding sheds to their live line tools (e.g. hot sticks) as a possible mitigation measure. The effect of adding sheds to the hot sticks was modelled and published by Chalmers University. A strong case can be made for sheds if the model can be validated through laboratory testing. This research is envisioned to be a multiple-year project. The work proposed under this agreement represents the initial research steps which will involve reproducing, verifying, and extending the modeling research previously published by Chalmers University.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Surface charge kinetics near metal-dielectric interfaces exposed to kilovolt electron flux

Interfaces between dielectric films and grounded metallic boundaries were exposed, in vacuum, to monoenergic electron fluxes having energies up to 22 keV. Two principal concerns were the measuring of the charge distributions on dielectrics and the determining of causes of flashovers, events where dielectric surface charges abruptly transfer to the metallic structures. Surface charges are perturbed within 10 mm of interfaces. Perturbations are relatively small except within about 3 mm of the interface. The probability of flashover was found to be related to microscopic imperfections in the interfaces. As flashovers occur in an exposed metal substrate, points become burned into the dielectric along the slit. As these points develop, the probability of flashover increases greatly. An interface which is highly immune to flashover was formed by covering a dielectric film with a 1.5-mm-thick aperture plate which exposes the film through a machined opening.

Robinson, J. W.↗

An experimental investigation of pulsed multichannel discharge across solid insulators

An experimental study of pulsed surface flashover across a solid insulator in a vacuum is reported, with application of fast impulse voltages of a few tens of ns rise time and a few microsec tail time. Following the flashover voltage experiments, no visible degradation of the surface was found for the BaTiO3 sample, whereas for the TiO2 sample a distinct track mark could be seen where the flashover occurred. Three schemes for obtaining multichannel discharges were studied for plexiglass specimens, and results showed the number of shots to decrease as the number of channels increased.

Lakdawala, V. K.↗

Townsend coefficients for electron scattering over dielectric surfaces

A method for describing the probability of initiating flashover discharges across dielectric surfaces is presented in which a transport coefficient for electron multiplication similar to the Townsend coefficient used for gas discharges is defined. The coefficient is a function of the scaling parameter (charge released from the cathode)/(cathode-anode separation) and is also a measure of the growth of the sheath on the dielectric surface resulting from electron scattering. Results are discussed as to when the source of seed electrons does not necessarily depend upon field emission at the cathode-vacuum-dielectric triple point. For these conditions, there is a different functional dependence of flashover probability on voltage and geometry than when field emission provides the seed electrons. As a result, criteria previously used to predict flashover discharges may not apply.

Peck, Timothy L.↗

Model fire tests on polyphosphazene rubber and polyvinyl chloride (PVC)/nitrile rubber foams

A video tape record of model room fire tests was shown, comparing polyphosphazene (P-N) rubber and polyvinyl chloride (PVC)/nitrile rubber closed-cell foams as interior finish thermal insulation under conditions directly translatable to an actual fire situation. Flashover did not occur with the P-N foam and only moderate amounts of low density smoke were formed, whereas with the PVC/nitrile foam, flashover occurred quickly and large volumes of high density smoke were emitted. The P-N foam was produced in a pilot plant under carefully controlled conditions. The PVC/nitrile foam was a commercial product. A major phase of the overall program involved fire tests on P-N open-cell foam cushioning.

Widenor, W. M.↗

Model for breakdown process in dielectric discharges

A heuristic model to explain the blowoff of charge during an electron-induced dielectric discharge is presented. It is proposed that blowoff of charge is initiated by a punchthrough or a flashover. The discharge time is assumed to be governed by an LC time constant where L is the inductance of the electrons flowing in the branches of the Lichtenberg figures at an electron range below the irradiated surface and C is the capacitance between the trapped electrons and the substrate for the discharged area. Experiments to verify that blowoff is a consequence of punchthrough or flashover and to measure the punchthrough current and the variation of discharge time with the sample area and thickness were conducted.

Leadon, R.↗

Electrostatic Discharge Test of Multi-Junction Solar Array Coupons After Combined Space Environmental Exposures

A set of multi-junction GaAs/Ge solar array test coupons were subjected to a sequence of 5-year increments of combined environmental exposure tests. The test coupons capture an integrated design intended for use in a geosynchronous (GEO) space environment. A key component of this test campaign is conducting electrostatic discharge (ESD) tests in the inverted gradient mode. The protocol of the ESD tests is based on the ISO/CD 11221, the ISO standard for ESD testing on solar array panels. This standard is currently in its final review with expected approval in 2010. The test schematic in the ISO reference has been modified with Space System/Loral designed circuitry to better simulate the on-orbit operational conditions of its solar array design. Part of the modified circuitry is to simulate a solar array panel coverglass flashover discharge. All solar array coupons used in the test campaign consist of 4 cells. The ESD tests are performed at the beginning of life (BOL) and at each 5-year environment exposure point. The environmental exposure sequence consists of UV radiation, electron/proton particle radiation, thermal cycling, and ion thruster plume. This paper discusses the coverglass flashover simulation, ESD test setup, and the importance of the electrical test design in simulating the on-orbit operational conditions. Results from 5th-year testing are compared to the baseline ESD characteristics determined at the BOL condition.

Wright, Kenneth H.↗

Determining the Minimum Phase‐to‐Phase Gap Distance for Unconventional Transmission Lines Using Numerical Method

With the increasing demand for power transmission, compact, high surge impedance loading (HSIL) high-voltage transmission lines have emerged as a viable solution due to their reduced land acquisition costs and higher power delivery capability. The compactness of a transmission line depends on effective insulation coordination, particularly in determining the phase-to-phase clearance, which is governed by the critical flashover voltage under switching and lightning overvoltage conditions. Traditional methods for phase-to-phase clearance rely on empirical formulas derived from experimental data, which are convenient for conventional high-voltage lines. However, unconventional HSIL lines require a faster and more adaptable evaluation method, as they involve optimized conductor positioning to reduce right-of-way requirements while enhancing natural power loadability. This study presents a simplified numerical approach to determine the minimum phase-to-phase gap, utilizing arc propagation viability curves, and offers an efficient alternative to conventional empirical methods. The proposed method was successfully applied to a 500 kV conventional line as well as 500 and 735 kV unconventional line designs, demonstrating its capability in accurately assessing insulation requirements. Results reveal that the method can support reduced gap clearances while still maintaining reliability, thereby validating its usefulness in optimizing compact transmission line configurations.

Arafat, Easir [The University of Texas at Dallas, ↗