Search NASA⌕ Search

SEARCH · Search NASA

Results for “flight optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Incident beam optics optimization for the single crystal neutron diffractometer Pioneer with a polarized beam option

Pioneer, a next-generation single-crystal neutron diffractometer, is under development for Oak Ridge National Laboratory’s Second Target Station. Designed to address a wide range of scientific questions, Pioneer will deliver homogeneous neutron beams with customizable size and divergence and provide a polarized beam option. This article introduces its incident beam optics, highlighting the optimization methodology and the simulated performance. Pioneer will utilize a modified elliptical-straight guide for neutron transport and deploy slit packages and insertable apertures to control beam size and divergence. The optimized guide geometry matches the optimal-and-full-sample-illumination condition, and the beam control system effectively filters out unwanted neutrons while preserving the desired ones. In addition, we have found that polygon-approximated guides provide satisfactory transport efficiency and beam homogeneity, eliminating the need for truly curved guides. Further, to enhance neutronics performance and reduce cost, the coatings of supermirror elements are individually optimized to the lowest half-integer m-values that are sufficient to deliver the desired neutrons. After evaluating polarizing V-cavities and 3 He spin filters over the default polarized wavelength band of 1.2–5.5 Å, we selected a translatable multichannel polarizing V-cavity as the incident beam polarizer. Strategically placed at a location where the beam divergence is low and a large in-guide gap has negligible impact on transport efficiency, the optimized V-cavity achieves an average P 2 T of ~35%.

47 OTHER INSTRUMENTATION↗

Space Mission Options for Reconnaissance and Mitigation of Asteroid 2024 YR4

Near-Earth asteroid 2024 YR 4 was discovered on 2024-12-27 and its probability of Earth impact in December 2032 peaked at ~3% on 2025-02-18. Additional observations ruled out Earth impact by 2025-02-23. However, the probability of lunar impact in December 2032 then rose, reaching ~4% by the end of the apparition in May 2025. James Webb Space Telescope (JWST) observations on 2025-03-26 estimated the asteroid’s diameter at 60 ± 7 m. Studies of 2024 YR 4 ’s potential lunar impact effects suggest lunar ejecta could increase micrometeoroid debris flux in low Earth orbit up to 1000 times above background levels over just a few days, possibly threatening astronauts and spacecraft. In this work, we present options for space missions to 2024 YR 4 that could be utilized if lunar impact is confirmed. Here, we cover flyby & rendezvous reconnaissance, deflection, and robust disruption of the asteroid. We examine both rapid-response and delayed launch options through 2032. We evaluate chemical and solar electric propulsion, various launch vehicles, optimized deep space maneuvers, and gravity assists. Re-tasking extant spacecraft and using built spacecraft not yet launched are also considered. The best reconnaissance mission options launch in late 2028, leaving only approximately three years for development at the time of this writing in August 2025. Deflection missions were assessed and appear impractical. However, kinetic robust disruption missions are available with launches between April 2030 and April 2032. Nuclear robust disruption missions are also available with launches between late 2029 and late 2031. Finally, even if lunar impact is ruled out there is significant potential utility in deploying a reconnaissance mission to characterize the asteroid.

Asteroid deflection↗

Study of the Design and Characteristics of a Modified Pulsed Plasma Thruster with Graphite and Tungsten Trigger Electrodes

The paper presents experimental results for a modified pulsed plasma thruster (PPT) with solid propellant, using a coaxial anode–cathode design. Graphite from pencil leads served as propellant, and a tungsten trigger electrode was tested to reduce carbonization effects. Experiments were performed in a vacuum chamber at 0.001 Pa, employing diagnostics such as discharge current/voltage recording, power measurement, ballistic pendulum, time-of-flight (TOF) method, and a Faraday cup. Current and voltage waveforms matched an oscillatory RLC circuit with variable plasma channel resistance. Key discharge parameters were measured, including current pulse duration/amplitude and plasma channel formation/decay dynamics. Impulse bit values, obtained with a ballistic pendulum, reached up to 8.5 μN·s. Increasing trigger capacitor capacitance reduced thrust due to unstable “pre-plasma” formation and partial pre-discharge energy loss. Using TOF and Faraday cup diagnostics, plasma front velocity, ion current amplitude, current density, and ion concentration were determined. Tungsten electrodes produced lower charged particle concentrations than graphite but offered better adhesion resistance, minimal carbonization, and stable long-term performance. The findings support optimizing trigger electrode materials and PPT operating modes to extend lifetime and stabilize thrust output.

Faraday cup↗

Enhanced Optical Contrast and Switching in Near‐Infrared Electrochromic Devices by Optimizing Conjugated Polymer Oligo(Ethylene Glycol) Sidechain Content and Gel Electrolyte Composition

Abstract A detailed investigation addressing the effects of functionalizing conjugated polymers with oligo(ethylene glycol) (EG n ) sidechains on the performance and polymer‐electrolyte compatibility of electrochromic devices (ECDs) is reported. The electrochemistry for a series of donor‐acceptor copolymers having near‐infrared (NIR)‐optical absorption, where the donor fragment is 3,4‐ethylenedioxythiophene (EDOT) or an EG n functionalized bithiophene (g2T) and the acceptor fragment is diketopyrrolopyrrole (DPP) functionalized with branched alkyl or EG n sidechains, is extensively probed. ECDs are next fabricated and it is found that EG n sidechain incorporation must be finely balanced to promote polymer‐electrolyte compatibility and provide efficient ion exchange. Proper electrolyte‐cation pairing and polymer structural tuning affords a 2x increase in optical contrast (from 12% to 24%) and >60x reduction in switching time (from 20 to 0.3 s). Atomic force microscopy (AFM)/grazing incidence wide‐angle X‐ray scattering (GIWAXS) characterization of the polymer film morphology/microstructure reveals that an over‐abundance of EG n sidechains generates large polymer crystallites, which can suppress ion exchange. Lastly, time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) indicates sidechain/electrolyte identity does not influence the electrolyte penetration depth into the films, and EG n sidechain inclusion increases electrolyte cation uptake. The material structural design insight and guidelines regarding the polymer‐electrolyte ion insertion/expulsion dynamics reported here should be of significant utility for developing next‐generation mixed ionic‐electronic conducting materials.

Chemistry↗

Enhancing the Cherenkov over scintillation ratio using dichroic filters in BGO and TlCl for TOF-PET

Abstract The Cherenkov emission in inorganic crystal scintillators has been shown to dramatically improve time resolution for time-of-flight positron emission tomography (TOF-PET) for in slow scintillators with a high refractive index such as bismuth germanium oxide (BGO). This is due to the faster nature of the Cherenkov emission (tens of picoseconds) with respect to scintillation (nanosecond). However, the presence of slower scintillation light and the inability of existing detectors to distinguish between Cherenkov and scintillation make it difficult for BGO to achieve a good CTR for all the detected coincidence events. In this paper, we exploit the difference between the Cherenkov and scintillation emission spectra and use dichroic filters to enhance the Cherenkov over scintillation ratio. Dichroic filters transmit or reflect photons based on their wavelength, with a photon attenuation lower than 10%. We investigate several shortpass and longpass dichroic filters in a single-photon configuration with BGO and find the optimal filter that maximizes the Cherenkov over scintillation ratio. We demonstrate that we can enhance the ratio of Cherenkov to scintillation photons by a factor of 2.17 ± 0.38 by employing a shortpass dichroic filter with a cut-off wavelength of 450 nm for BGO, and by a factor of 2.87 ± 0.40 using a longpass dichroic filter with a cut-on wavelength of 550 nm for iodine/beryllium-doped thallium chloride.

Science & Technology - Other Topics↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

Machine learning inversion of interatomic force constants from single-crystal inelastic neutron scattering

Atomic vibrations govern many macroscopic properties of materials, but experiments to comprehensively probe them remain challenging. Inelastic neutron scattering (INS) is a powerful technique to map phonon dispersions in crystals, especially when leveraging modern time-of-flight (ToF) spectrometers with large detectors. However, efficiently and robustly extracting interatomic force constants (FCs) parameterizing phonon dynamics from experimental spectra remains a bottleneck due to the complexity and high dimensionality of ToF INS datasets. Here, we present a machine learning approach for the direct inversion of FCs from single-crystal INS measurements. The framework leverages synthetic training data generated using universal machine-learned force fields and an efficient physics-based forward model. We benchmark two neural architectures–one emphasizing structured latent representation learning and the other direct, supervised spectral regression–across simulated datasets for two materials under idealized and noisy conditions. The latent-representation model is subsequently applied to experimental single-crystal INS data on germanium. The model is shown to reproduce FCs derived from both first-principles simulations and from iterative optimization, and furthermore achieves reliable inference even from sparse, single-orientation measurements representing short data acquisitions. Analysis of the learned latent space reveals semantically continuous and physically interpretable encodings that support strong cross-domain generalization. By bridging theoretical and experimental domains, we establish a path toward rapid inversion of experimental spectra and data-driven interpretation of temperature-dependent lattice dynamics.

42 ENGINEERING↗

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

A Scalable & Non-Destructive Characterization Strategy to Study Semiconductor/Dielectric Interfaces and Predict Wafer-Level Device Performance

The defect density present at the dielectric-semiconductor interface in an MOS structure directly influences the channel carrier characteristics in semiconductor devices, especially in wide bandgap material systems used in power devices. While these trap defects are typically quantified through electrical characterization of MOS-capacitor test structures, this treatment offers very little insight into the physical nature of interface defects. Such shortcomings demand a physical characterization strategy to guide fabrication optimization. X-ray photoelectron spectroscopy (XPS) is suggested as a viable technique to determine chemical data for dielectric interfaces formed using atomic layer deposition (ALD) on GaN substrates. Previously, 1-D XPS characterization has confirmed the presence of a Ga x O y interlayer between ALD dielectrics and the GaN substrate. In this work, XPS data is serially collected to form 2-D images of an ALD-Al 2 O 3 /GaN interface as a proof-of-concept experiment for in-situ XPS quality monitoring during ALD processing. The information provided by this work reveals some of the challenges for incorporating XPS characterization as an in-situ strategy during fabrication of GaN-based devices. Separately, electrical mapping of a 2-D array of ALD-Al 2 O 3 /GaN MOS-capacitor devices provide a means to quantify the spatial variations in interface quality across a single wafer. Physical characterization techniques, such as time-of-flight secondary ion mass spectroscopy, provide additional chemical information about the Al 2 O 3 /Ga x O y /GaN structure that complement the electrical mapping results. This analysis shows that a higher Ga x O y content correlates with higher interface state defects for trap energies deep in the band gap.

42 ENGINEERING↗

Characterizing the Roman Grism Redshift Efficiency of Type Ia Supernova Host Galaxies for the High-latitude Time-domain Survey

The High-latitude Time-domain Survey (HLTDS) for the Nancy Grace Roman Space Telescope (Roman) will discover thousands of high-redshift Type Ia supernovae (SNe Ia) to set generation-defining cosmological constraints on dark energy. To construct the Roman SN Hubble diagram, a strategy to obtain redshifts must be determined. While the nominal HLTDS will use only the Roman prism, in this work, we consider the utility of the Roman grism observations from overlap with the High-latitude Wide-area Survey for SN Ia cosmology. We determine a galaxy grism redshift recovery rate by simulating dispersed grism images and measuring redshifts with the Grizli software, obtaining an H-band 50% redshift recovery at magnitude 20.61 and 90% recovery at magnitude 19.27. To estimate the total number of spectroscopic redshifts expected for Roman SN cosmology, we also consider a Roman prism SN redshift efficiency and a ground-based telescope redshift efficiency for host galaxies. We apply these redshift efficiencies to SN Ia catalog-level simulations and predict that ∼6800 SNe will have an SN or host spectroscopic redshift. Second, we evaluate the size of potential systematics related to modeling the grism redshift efficiency by considering the impact of additional dependences on stellar mass and host-galaxy color. We estimate the largest potential size of this systematic to be 0.0066 ± 0.002 and −0.0266 ± 0.0079, roughly 42.9% and 49.6% of the statistical uncertainty, for w 0 and w a , respectively. Lastly, we consider the effects of assuming different redshift sources on the optimization of the HLTDS survey strategy by measuring relative changes to the dark energy figure of merit.

Chen, Rebecca C. [Duke Univ., Durham, NC (United S↗

Large field-of-view event-mode camera for high-precision epithermal neutron resonance imaging

A large-area event-mode camera system coupled with a 6 LiF-ZnS:Ag scintillator is applied for neutron resonance imaging (NRI) on the energy-resolved neutron imaging (ERNI) flight path, also known as Flight Path 5 (FP5), at the Los Alamos Neutron Science Center (LANSCE). This novel neutron imaging system, featuring a 120 x 120 mm 2 field of view, efficiently captures resonance information across the entire image in a single acquisition, significantly reducing beam time requirements compared to conventional energy-resolved neutron imaging systems. High-quality neutron radiographs with enhanced spatial resolution are achieved through the reconstruction of neutron events based on observations of individual photons emitted from the scintillator. The system demonstrates reduced background through neutron/gamma discrimination capabilities while maintaining sharpness across a large fields of view. In the measurements presented here, a spatial resolution of approximately 340 μm was achieved using center-of-gravity photon cluster centroiding. We demonstrate the system’s capability for quantitatively determining isotopic distributions in various thin samples, as well as automatically reconstructing complex scenes with overlapping resonances from diverse samples. These results are obtained using standard data analysis tools, despite the relatively slow 6 LiF-ZnS:Ag scintillator, which may not be optimal for absorption resonance detection. The capabilities demonstrated here offer a valuable, versatile, and cost-effective solution for high spatial and temporal resolution, large field-of-view energy-resolved neutron imaging, with potential applications across various scientific and industrial domains.

36 MATERIALS SCIENCE↗

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing Transmission of Acoustic Signals to Monitor Internal Conditions of Canisters for Dry Storage of Commercial Spent Nuclear Fuel

Safe storage of spent nuclear fuel (SNF) is critical to the nuclear fuel cycle and the future of nuclear energy. In the United States, SNF is stored primarily via two methods regulated by the U.S. Nuclear Regulatory Commission: wet storage in SNF pools and dry storage in dry cask storage systems (DCSSs). After about five years of cooling in spent fuel pools, the fuel assemblies are transferred into DCSSs, and the systems are filled with helium and sealed by welding. Deterioration of conditions inside of a DCSS is reflected in changes in the internal gas properties; this motivates the development of acoustic techniques to monitor internal gas properties, over extended storage periods, using sensors mounted on the exterior of the storage packages. However, a major challenge in collecting acoustic signals is the impedance mismatch between the steel canister shell and the gas. Only a small fraction of the ultrasonic signal can be transmitted through the gas medium. This paper documents experimental studies conducted on a full-scale canister mock-up to capture the gas-borne signals. Damping materials were pasted on the outside, and blocking and unblocking tests were conducted to identify the gas-borne signal. The results show that the excitation frequency plays an important role in maximizing the gas-borne signals. The gas-borne signal was successfully detected at around the theoretical time-of-flight. A high signal-to-noise ratio was achieved in the measurements. Next, the acoustic impedance matching layers were introduced, and the gas signal was drastically improved compared with that using no AIM layers.

Spent nuclear fuel (SNF), Canisters, Internal cond↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

A Generalized Grain-Scale Model for the Non-Plasma and Plasma-Assisted Hydrogen Direct Reduction of Iron Ore

Direct Reduction of Iron ore using hydrogen (H-DRI) is a promising pathway towards efficient steelmaking and accurate predictive models are a necessity for scale-up and optimization of this technology. However, accurate models of this process remain limited because existing models oversimplify grain-scale phenomena, such as nonlinearity inside grain, self-sufficient porosity, surface reactions, and the role of plasma species. These phenomena are important for flash steelmaking and plasma-assisted H-DRI processes. To address this need, we present a phenomenological model for simulating H-DRI at the scale of a single micron-sized grain of the iron ore. We call this the Transient Reactive Grain Model (TRGM). TRGM incorporates key physical process: gas species transport, a chemical kinetics of material conversion, nanopore structural evolution and, adsorption-desorption surface kinetics at the reactive nanopore surface. The important contribution of this work is that the model provides a dependence on different reductant species, specifically hydrogen atoms versus molecules, so that role of hydrogen plasma reduction can be clarified compared to the use of pure hydrogen gas reduction. TRGM predictions agree well with experimental data for both molecular H2 reduction of Fe2O3 and plasma hydrogen reduction of Fe3O4. Results reveal species concentration gradients with a diffuse reaction zone, and enhanced hydrogen diffusion at the grain outer surface due to evolving porosity. These findings challenge common assumptions in existing models, including sharp reaction fronts, quasi-steady diffusion and kinetics, and the neglect of surface chemistry. As a generalized grain-scale model for H-DRI processes, TRGM has practical applications in flash steelmaking and in-flight reduction using both molecular and plasma hydrogen.

08 HYDROGEN↗

Videos, photos, and AI-derived grain size data associated with “High-throughput AI Video Surveys Enable Reproducible Multiscale Sediment Size Mapping, with Implications for Hydrobiogeochemical Parameterization”

NOTE: The manuscript associated with this data package is currently in review. The data may be revised based on reviewer feedback. Upon manuscript acceptance, this data package will be updated with the final dataset and additional metadata. This data package is associated with the manuscript “High-throughput AI Video Surveys Enable Reproducible Multiscale Sediment Size Mapping, with Implications for Hydrobiogeochemical Parameterization” under review. This data package includes five data types: 1) raw photos and videos from drone survey and walking smartphone surveys; 2) images derived from raw videos; 3) manual labeling of reference scales; 4) metadata for all images and photo resolution derived from artificial intelligence (AI) models or manual labels, 5) grain size data obtained from AI models for all photos, 6) metadata and grain size data after quality control, 7) summaries of sample efficiency for all data, and 8) computational fluid dynamics (CFD) data used to support hydro-biogeochemical (HBGC) parameter estimation. Such data is used to 1) demonstrate significant improvements in accuracy, efficiency, and quality control for grain size data collection with the help of AI models, 2) study the spatial heterogeneity of grain size and observation reproducibility based on tens of thousands of data points generated by the AI models, and 3) evaluate the impacts of grain size heterogeneity on key HBGC parameters across sediment-to-reach and hourly-to-yearly scales. In particular, the data package contains 116 folders and 179696 files. The files include 41 videos in .mov format, 64047 photos in .jpg format, 13541 video-derived photos in .png format, 12747 segmentation mask data in .tif format, 12747 segmentation data in .json format, 24771 .csv files that with metadata and grain size for each individual photo as well as water depth and velocity data from CFD and observation, 51791 .txt files of raw AI predicted labels, and 11 flight record data in .srt format. The summary for all metadata and grain size statistics information is included in “Scales_V3_NG.csv” and “Statistics_V3_NG.csv”. The summary for data that pass data quality control (QC) level 0-2 is included in “QCStatistics_V3_NG.csv”. The QC level 0 represents photos whose photo resolution is positive, excluding photos that miss reference scale. The QC level 1 means reference scale circularity uncertainty is less than 5% for smartphone images while representing photo resolution is larger than 0.44 mm/pixel for drone images. The QC level 2 means excluding photos whose grain number is less than 100, a minimum number of grains recommended by classic literature. The summary for each video’s name, length, frame rates, survey area, grain number, survey efficiency, etc. can be found in “QCSummary_V3_NG.csv”. The summary for site name, GPS coordinates, and number of images at each site can be found in “SitesSummary_V3_*.csv” files. Overall computational efficiency summary is reported in Table 4 of accompanying manuscript. Additionally, the nitrate concentration data used in this work was downloaded from an existing dataset published on ESS-DIVE (Boat-Dragged Sensor Hanford Reach.csv; Conner A. et al., 2020). We thank the United States Forest Service, Washington Department of Fish and Wildlife, Washington Department of Natural Resources, Cowiche Canyon Conservatory, Port of Benton, and the Confederated Tribes and Bands of the Yakama Nation for access to field locations where the data were collected. We also thank the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate data collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗