Search NASA⌕ Search

SEARCH · Search NASA

Results for “flooring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A new dynamic zOnal model with air-diffuser (DOMA) - Application to thermal comfort prediction

A new Dynamic zOnal Model with Air-diffuser (DOMA) was developed. Several case studies were investigated and tested to evaluate and validate this program using measurement data. This new model was integrated into a TRaNsient SYstems Simulation program library and coupled with the multi-zone thermal model. The DOMA/TRNSYS coupled model was then used to predict room temperature distribution over an entire day of a single-zone building. The results show that increasing the heating outputs of the electric floor system, for example, from 75 to 200 W/m 2 , would not effectively improve the indoor thermal comfort, since the thermostat will reach the set point first and then turn off the system before the room gets enough heat and reach a comfortable level. This indicates the importance of selecting an appropriate location and set point for the thermostat when using a floor heating system. This potential thermal comfort issue can only be identified through the two-node model with a dynamic zonal model rather than the conventional PMV model, which thus suggests that for optimizing indoor thermal comfort of a building equipped with a time-sensitive control strategy and/or HVAC system, the TSENS results obtained from the two-node model integrated with DOMA are more appropriate than PMVs.

Construction & Building Technology↗

Terra-Populus v0.1: A Python Library for LandScan High-Definition Population Analysis and Modeling

The terra-populus library is designed for use by the LandScan HD technical team, offering a streamlined set of tools for generating and updating LandScan HD datasets from foundational building-level data, referred to as 'molecules,' provided by the building-level attribution team. This document serves as the primary technical documentation for terra-populus. Version 0.1 of the library includes the core modeling components necessary for LandScan HD production. It enables the generation of the LandScan HD Baseline dataset as well as corresponding confidence measures for the occupancy rates used. Parameters have been included for incorporating damaged building indicators and changes in population, to faciliate the creation of rapid updates for LandScan HD. Future iterations of terra-populus will introduce tools for creating a confidence index, and quantifying and propagating uncertainty, facilitating the creation of probabilistic LandScan HD outputs. This report provides an overview of the tools available in the library and the corresponding code implementations. One of the key advancements implemented in terra-populus is a redefinition of the atomic modeling unit for LandScan HD. Traditionally, the LandScan HD vector analytical framework has generated population estimates at the building sub-component (molecule) level. However, terra-populus adopts a building-level modeling approach. This shift is an operational decision aimed at aligning LandScan HD outputs with confidence measures, which are computed and validated at the building level (confidence measures are not included in this version of terra-populus, aside from those associated with the occupancy rates). Additional advancements to the LandScan HD modeling, as implemented by terra-populus, include a minimum population value parameter and an auto assignment of building floor counts. The population minimum value was implemented to prevent buildings and subsequent LandScan HD pixels that contained small values that may not rasterize in production. An 'auto' value has been included as a method for dealing with buildings lacking floor count information, where it is the average floor count of all other buildings with a residential building use type tag. The logic behind this is to remain consistent with the current logic employed for dealing with building use type null instances, where a null use type is defaulted to residential since it is the most common building type. The auto logic is intended to apply the most common building floor count of the most common type of buildings. The tools provided in terra-populus represent a significant step forward in improving the efficiency, reproducibility, and transparency of the LandScan HD modeling process. As the library evolves, it will continue to serve as a foundational resource for high-resolution population modeling.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Material flows and GHG emissions from housing stock evolution in US counties, 2020–60

The evolution of housing stocks determines demand for construction materials and energy, and associated emissions of greenhouse gasses (GHGs). The contribution of construction to building life-cycle emissions is growing as buildings become more energy efficient and the energy supply decarbonizes. A housing stock model is developed for counties in the United States using dynamic vacancy rates which endogenously influence stock out- and inflows. Stocks of three house types and 10 construction cohorts are projected for all contiguous US counties for the period 2020–60. Inflows and outflows of construction materials are then estimated along with GHG emissions associated with material production and construction activities in scenarios defined by stock turnover rates, population share by house type, and floor area characteristics of new houses. The results provide new insights into the drivers of construction-related emissions at local and national levels, and identify opportunities for their reduction. Demolition material flows grow in relation to construction material flows over the analysis period. Increasing the stock turnover rate increases future floor area per person, material requirements, and emissions from construction. Scenarios with reduced floor area and more multifamily homes in new construction have lower floor area growth, material requirements, and emissions from construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effectiveness of Vapor Corrosion Inhibitors Under Elevated Chloride Conditions for Aboveground Storage Tank Application

The sand quality used to construct the tank pad is an important contributing factor to the rate of corrosion that occurs on the soil-side of the aboveground storage tanks (ASTs) floor plates. Clean sand that meets specific criteria provides the first line of defense for mitigation of tank floor corrosion. However, it has been observed that the sand quality used for some existing tanks differ greatly from the specifications provided in the API 651 standard; this could be partially due to initial sand quality not meeting the specification, and partially due to the environmental effects over time. For example, rain-water intrusion could lead to higher than the specified contents of corrosive species such as chloride. Tank operators are increasingly using vapor corrosion inhibitors (VCIs) either as a stand alone or in combination with cathodic protection (CP) for ASTs to mitigate soil-side corrosion. VCIs are delivered either through-thefloor or injected through the ports in the ring wall. Experimental studies were conducted to evaluate VCIs’ performance at elevated chloride concentrations and to study the effectiveness of the delivery methods under extreme chloride conditions. The experimental work found that VCI performance is robust and not compromised due to high chloride levels, such as 300 ppm or more. The work also showed that the through-the-floor VCI delivery method is more beneficial compared to the through-the-sand-pad method when tank pad corrosivity is elevated.

Shukla, Pavan K.↗

Effect of recycled fibers and shredded intermediates variation on the mechanical properties and energy absorption of fiber‐reinforced composite panels

Abstract The global composite industry generates large quantities of waste which mostly ends up in landfills due to a lack of established end‐use applications for multiple waste streams. The scrap from end‐of‐life (EoL) includes manufacturing waste such as dry chopped fiber tows, loose fibers, shredded fibers from fabric textile operations, cured/semi‐cured prepregs, and fully cured composite structure waste from aircraft, automobiles, wind blades, boats, and pressure vessels. In this work, different composite waste streams were reduced to shredded intermediates, followed by simple blending, and subjected to wet compression molding to produce composite panels. The panels/plaques were tested for mechanical properties (flexure and impact), fiber‐matrix wet‐out, and property bounds. It was found that wet‐compression molding was a viable and scale‐able approach to produce recycled panels from EoL composites shredded scrap. Furthermore, full‐scale size panels for use in truck bodies and intermodal shipping container flooring were manufactured and their impact resistance was tested using a drop weight impact test. They were tested both for high‐ and low‐velocity load. In the case of high‐velocity load, the average impact load was 14,673 N; the average absorbed energy was 101.6 J; the average elastic energy was 11.7 J and the impact resistance was 1065 J/m. In the case of the low‐velocity drop weight impact test, it was found that the average impact load was 7877.358 N; the average absorbed energy was 9.718 J; the average elastic energy was 9.14 J, and the impact resistance was 184.1 J/m. The shredded composite was shown to be a candidate material for the manufacture of truck bodies and intermodal containers’ flooring panels. Highlights By using shredded intermediates from different composite waste streams, it is possible to manufacture composite panels. Wet–compression process is an appropriate technique for manufacturing recycled fiber composite panels. Regardless of the source of scrap, the mechanical properties of the produced composite panels were improved. The recycling process technology can be transformed to commercial scale to produce full‐size transportation flooring panels. A product pathway is established in consideration of lower cost and improved recyclability.

Vaidya, Uday↗

Updated Available Drawdowns for Big Hill SPR Caverns - Model Including the Caprock Fault

This report updates the estimated values of the baseline available drawdowns for the caverns at the Big Hill storage facility, and an updated table listing the available drawdowns. An updated finite element numerical analysis model, which included a fault in the caprock layers, was constructed and the daily data of actual wellhead pressures and oil-brine interfaces was used. The number of available drawdowns for each of the Big Hill SPR caverns is estimated using the new model. All caverns are predicted to have five available drawdowns remaining from a geomechanical perspective. BH-101 and 105 have a region of concern at the floor edge and/or sloping floor, where tensile and dilatant stresses are predicted to occur during each workover. The tensile state is predicted to occur because of the geometries of the edge and floor. Therefore, geomechanical examination for two caverns would be recommended after a drawdown leach. The well integrity of each cavern is not investigated in this report. The estimates for the number of baseline available drawdowns are subject to change in the future as the knowledge of physical phenomena at the sites, and the further development of the models of geomechanical behavior at the sites, evolve over time.

02 PETROLEUM↗

UT-GOM2-2 Drilling Fluid (Technical Note)

It is proposed that a salt-saturated, water-based mud might improve borehole stability for UT-GOM2-2 relative to a fresh-water-based mud. However, the primary objective for UT-GOM2-2 is to safely and successfully acquire uncompromised hydrate-bearing sediment cores. This can only be done if conditions stay within the hydrate stability zone, and well away from the hydrate stability boundary. The addition of salt to the drilling mud, shifts the hydrate stability boundary closer to estimated conditions. This shift, by some estimates of pressure and temperature, where conditions now fall outside of the hydrate stability zone, may result in borehole enlargement and the release of free gas into the borehole. This shift by all estimates, even when coring conditions stay inside the hydrate stability zone, shrinks the window between the estimated conditions and the hydrate stability boundary. This shift is likely to compromise the hydrate-bearing cores while they are being recovered from the bottom-hole to the rig floor. In this report we present two examples: 1) Assuming temperature and pressure from in-situ estimates: Hydrate within the target reservoirs (Orange and Blue) at Walker Ridge Block 313 (WR 313) will be outside the hydrate stability zone in the presence of a drilling mud with 9.5 wt.% salinity (the salinity of the proposed 10.5 ppg salt-based mud) at in situ pressure and temperature. Thus, the hydrate will be unstable. A 10.5 ppg salt-based mud may result in dissociation of the hydrate into its components: water and gas. 10.5 ppg salt-based mud may enlarge the borehole, release free gas into the borehole, and compromise the cores. 2) Assuming temperatures equal to the measured LWD borehole temperatures at this location: Hydrate within the target reservoirs will be stable with a salinity of 9.5 wt.% (the salinity of the proposed 10.5 ppg salt-based mud), but possibly unstable (just at the methane hydrate stability boundary) for a salinity of 17.2 wt.% (the salinity of the proposed 13.5 ppg salt-based kill mud). if the borehole has the same temperature as recorded during previous LWD drilling at this location. A 13.5 ppg salt-based kill mud may destabilize the borehole. More importantly, a 10.5 ppg salt-based mud does not provide a large enough window between the estimated conditions and the hydrate stability boundary. Core temperatures and pressures fluctuate from the bottom-hole conditions as the core is brought up from the bottom-hole to the rig floor. These fluctuations are likely to cause the hydrate in the cores to touch or cross the stability boundary. Therefore, cores captured using a 10.5 ppg salt-based mud are likely to be compromised during core recovery to the rig floor.

03 NATURAL GAS↗

Defining the Prototype Convenience Store Building Characteristics

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 30 prototype building models (20 different building types), which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). This report documents the building and system characteristics of the prototype convenience store building model. Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype convenience store building characteristics, and a one-story, 3,000 ft 2 building was considered as the prototype convenience store to represent an average-sized convenience store in the United States. The Oak Ridge National Laboratory team defined the operational hours of the convenience store as 17 hours per day. The types of exterior walls, roof, and floor were defined as brick wall, metal surfacing roof, and slab-on-grade floor, respectively. Double glazing was selected, and the window-towall ratio was set as 15% on the front side. For the system part, packaged system and centralized water heater were selected for the space heating and cooling system and water heater system, respectively. In terms of the refrigerator system, the number of refrigerators and freezers were determined as eight closed cases and two walk-in units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrity Monitoring, Prediction and Assessment, Corrosion Control, and Repair of the Hanford Storage Tanks – 25213

The Hanford Nuclear Reservation site contains approximately 211 million liters of radioactive and chemically hazardous waste arising from nuclear weapons production, beginning with World War II, and continuing through the Cold War [1]. The waste is stored in 177 carbon-steel underground storage tanks, of which 149 are single-shell tanks (SSTs) and the remaining are double-shell tanks (DSTs). The mission of an ongoing River Protection Project is to retrieve the waste from the underground storage tanks and then treat and immobilize (i.e., vitrify) it for disposal. Waste from the older SSTs is being progressively retrieved into the newer DSTs for storage pending treatment, immobilization, and disposal. Figure 1 depicts a typical DST design [2]. The tank is approximately 23 m in diameter and 9 m high and has a domed structure and has a capacity of 4000 m3. The tank wall and floor vary in thickness between approximately 10 mm and 25 mm depending on location. The thicker wall sections are near the curved transition between the tank wall and the floor, while the thinner sections are located near the top of the tank wall. The tank floor thickness varies from 25 mm at the tank center to 10 mm near the tank wall. The tanks were constructed of either ASTM A516 Grade 65 or ASTM A537 Class 1 carbon steel and were post-weld heat treated to reduce the risk of SCC.

Shukla, Pavan K. [Savannah River National Laborato↗

Measuring Impact: Evaluating Thermal Zoning Simplification on Energy Efficiency Measures Analysis

Building Energy Modeling (BEM) is a versatile tool for designing, retrofitting, ensuring code compliance, obtaining certifications, qualifying for incentives, and enabling real-time building control. However, capturing all the details of building geometry for thermal zoning can be time-consuming, costly, and sometimes computationally challenging. As a result, modelers have been applying zoning simplification based on factors such as space functions and internal loads, as well as relying on their experience and judgment while adhering to zoning rules outlined in industry standards. Despite the prevalence of this common practice, a notable gap exists in the literature regarding studies quantifying the influence of simplified thermal zoning on the evaluation of Energy Efficiency Measures (EEMs). Recognizing this gap, this paper seeks to contribute to the field by enhancing the understanding of how the simplification of thermal zoning influences the evaluation of EEMs against a baseline design. The study utilized a medium office prototype model with a detailed floor plan featuring over 20 zones per floor covering diverse functional spaces with varying internal loads and occupancy schedules. A standard thermal zoning strategy outlined in ASHRAE Standard 90.1 Appendix G was employed as the simplified zoning method. This strategy condenses the zoning into a core zone and four perimeter zones per floor. It was compared with the detailed zoning approach, which involves one zone per space. Common Energy EEMs, such as enhanced envelope, high-efficiency appliances and equipment, and HVAC controls, were individually implemented and evaluated. The results indicate that the performance comparison between the two zoning methods varies depending on the type of measures considered. Basic measures, such as adding wall insulation, demonstrate similar energy impacts, while advanced HVAC control measures, such as static pressure reset, exhibit a more substantial difference that cannot be overlooked.

Xie, Jiarong↗

Life cycle Management of 324 Project High-Activity, Mixed/Low-Level Radioactive Waste - 20506

U.S. DOE contractor CH2M Hill Plateau Remediation Company (CHPRC) manages the 324 Building and is preparing to remotely excavate and disposition the radioactive soil beneath the building to allow further deactivation of the building. The 324 Building is a non-reactor Category 2 Nuclear Facility located in the 300 Area of the Hanford Site. Records indicate that in October 1986, approximately 516 liters of a concentrated liquid waste stream containing cesium-137 ({sup 137}Cs) and strontium-90 ({sup 90}Sr) spilled onto the floor of a hot cell, B-Cell, in the 324 Building. The spill contained an estimated 1.3 million curies (Ci) of radioactivity. A breach in the sump of B-Cell was discovered in November 2009 during characterization of the soil under the building. Exposure rates in excess of 10,000 R/hr were detected through a system of access pipes installed under the hot cell, and an estimated 1.557 E+05 Ci of {sup 137}Cs and 6.842 E+04 Ci of {sup 90}Sr are in the soil beneath B-Cell. The magnitude of the soil contamination below B-Cell represents one of the most challenging remediation activities in the DOE complex. The objective of CHPRC's 324 Project is to remotely excavate and disposition the highly contaminated soil under the hot cell so building deactivation and stabilization activities can resume. Depending on the volume and radioactivity of contaminated soil under B-Cell, the material will be dispositioned either at the Hanford Site's Environmental Restoration Disposal Facility (ERDF) or in grout monoliths that will be created in the hot cells (A, C and D) next to B-Cell during future building demolition activities. The current project scope includes installing structural supports under the walls of B-Cell and using remotely operated equipment to remove debris from the hot cell, remove debris mixed with grout on the floor, saw through and remove the cell floor and liner, and excavate contaminated soil under B-Cell to a depth of up to 3.66 meters (12 feet). Addition or removal of debris in A-Cell may be required to support B-Cell cleanout and excavation activities. The base approach is to disposition debris and soil bins in the Radiochemical Engineering Cell (REC) monoliths, and subsequently disposition the monoliths during building demolition. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Addressing Failures in Molten Salt Thermal Energy Storage Tank for Central Receiver Concentrating Solar Power Plants

The thermal energy storage (TES) system is a critical component in concentrated solar power (CSP) plants that increases the plant's capacity factor and economic competitiveness by reducing the levelized cost of energy (LCOE) while simultaneously increasing the value of the delivered energy. Failures including molten-salt leaks and diverse localized cracking after several months to a few years of operation have been reported in hot tanks for CSP plants operating around the world. A model of a molten salt thermal energy storage tank was developed and validated to analyze the impact of different tank design features on the temperature and stress distributions as a function of typical plant operation conditions. Design features included the floor plate thicknesses, friction coefficients between the tank floor and the foundation, and the sparger ring location. Maximum stresses in the tank floor frequently surpassed the yield point of the material during operation, leading to a detriment of the tank's lifetime. Recommendations on design features to improve the reliability of new molten salt tanks for CSP plants are provided.

concentrating solar power↗

Precision-controlled ultrafast electron microscope platforms. A case study: Multiple-order coherent phonon dynamics in 1T-TaSe2 probed at 50 fs–10 fm scales

We report on the first detailed beam tests attesting the fundamental principle behind the development of high-current-efficiency ultrafast electron microscope systems where a radio frequency (RF) cavity is incorporated as a condenser lens in the beam delivery system. To allow for the experiment to be carried out with a sufficient resolution to probe the performance at the emittance floor, a new cascade loop RF controller system is developed to reduce the RF noise floor. Temporal resolution at 50 fs in full-width-at-half-maximum and detection sensitivity better than 1% are demonstrated on exfoliated 1T-TaSe2 system under a moderate repetition rate. To benchmark the performance, multi-terahertz edge-mode coherent phonon excitation is employed as the standard candle. The high temporal resolution and the significant visibility to very low dynamical contrast in diffraction signals via high-precision phase-space manipulation give strong support to the working principle for the new high-brightness femtosecond electron microscope systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling of Stress Distribution in Molten Salt Thermal Energy Storage Tanks for In-Service Central Receiver Power Plants

Failures in molten nitrate salts thermal energy storage tanks (TES) have been occurring in several concentrating solar power (CSP) plants around the world after a few months or years of operation. These failures are mainly related to a combination of high stress, corrosion, large deformation, and thermal cycling. Most of these failures are a consequence of the infancy of this technology; technical standards for design, fabrication, implementation, and operation of molten salt tanks operating at temperatures up to 565 degrees Celsius do not exist and most of current in-service tanks have been designed using the recommendations from the American Petroleum Institute (API) 650 and the American Society of Mechanical Engineers ASME section II standards, which are applicable for TES tanks operating at lower temperatures. We have developed a 3-dimensional model of a representative molten salt hot tank design that uses typical CSP plant operation conditions and allows determining the temperature and stress distribution in the tank. The model also considers the initial floor residual stresses and distortion after its welding fabrication. We have identified critical thermal gradients in the tank floor and shell and locations in the tank where the stresses are high and could become susceptible points for failure.

concentrating solar power↗

Probing eddy size and its effective mixing length in stably stratified roughness sublayer flows

Stably stratified roughness sublayer flows are ubiquitous yet remain difficult to represent in models and to interpret using field experiments. Here, continuous high-frequency potential temperature profiles from the forest floor up to 6.5 times the canopy height observed with distributed temperature sensing (DTS) are used to link eddy topology to roughness sublayer stability correction functions and coupling between air layers within and above the canopy. The experiments are conducted at two forest stands classified as hydrodynamically sparse and dense. Near-continuous profiles of eddy sizes (length scales) and effective mixing lengths for heat are derived from the observed profiles using a novel conditional sampling approach. The approach utilizes potential temperature isoline fluctuations from a statically stable background state. The transport of potential temperature by an observed eddy is assumed to be conserved (adiabatic movement) and we assume that irreversible heat exchange between the eddy and the surrounding background occurs along the (vertical) periphery of the eddy. This assumption is analogous to Prandtl's mixing-length concept, where momentum is transported rapidly vertically and then equilibrated with the local mean velocity gradient. A distinct dependence of the derived length scales on background stratification, height above ground, and canopy characteristics emerges from the observed profiles. Implications of these findings for (1) the failure of Monin–Obukhov similarity in the roughness sublayer and (2) above-canopy flow coupling to the forest floor are examined. The findings have practical applications in terms of analysing similar DTS data sets with the proposed approach, modelling roughness sublayer flows, and interpreting nocturnal eddy covariance measurements above tall forested canopies.

54 ENVIRONMENTAL SCIENCES↗

Using AI Simulations to Dynamically Model Multi-agent Multi-team Energy Systems

The complexity of energy systems is well known as they are complex and intricate systems. As a result, many extant studies have used many simplifications or generalizations that do not accurately reflect the nature of this complex system. In particular, most HVAC systems are modeled as a single unit, or several large units, rather than as a hierarchical composite (e.g., as a floor rather than as a collection of disparate rooms). The net result of this is that the simulations are too generic to perform meaningful analysis, machine learning, or integrated simulation. We propose using a multi-agent multi-team strategic simulations framework called SiMAMT to better define, model, simulate, and learn the HVAC environment. SiMAMT allows us to create distinct models for each type of room, hierarchically aggregate them into units (like floors, or sections), and then into larger sets (like buildings or a campus), and then perform a simulation that interacts with each sub-element individually, the teams of sub-elements collectively, and the entire set in aggregation. Further, and most importantly, we additionally model another ‘team’ within the simulation framework - the users of the systems. Again, each individual is modeled distinctly, aggregated into sub-sets, then collected into large sets. Each user, or agent, is performing on their own but with respect to the larger team goals. This provides a simulation that has a much higher model fidelity and more applicable results that match the real-world.

Franklin, D. Michael↗

Estimating source-sink distributions and fluxes of reactive nitrogen and sulfur within a mixed forest canopy

The vertical source-sink distribution of air pollutants within and above forested canopies is necessary for describing the biological, physical, and chemical processes influencing the soil-vegetation-atmosphere exchange. Here, this study implemented inverse modeling methods to estimate the source-sink and flux profiles of reactive nitrogen (N) and sulfur (S) compounds from measurements of the mean concentration profiles of ammonia (NH 3 ), nitric acid (HNO 3 ), sulfur dioxide (SO 2 ), and particulate ammonium (NH 4 + ), nitrate (NO 3 − ), and sulfate (SO 4 2− ) at a forest site in the southern Appalachian Mountains. Three inverse approaches utilizing different approximations to scalar transport within the canopy were developed and evaluated against sensible heat flux measurements. The Eulerian model (EUL), which incorporates vertical velocity skewness, performed well in reproducing the turbulent heat fluxes and was subsequently used to calculate the chemical source-sink and flux profiles. Above-canopy fluxes of NH 3 were downward, indicating that the forest was a net sink of NH 3 . The soil/litter layer was both a source and a sink for NH 3 but the exchange rate at the forest floor was small. Fluxes of HNO 3 , SO 2 , NO 3 − , NH 4 + , and SO 4 2- were uni-directional (deposition only) between the air and the canopy/ground and increased monotonically from the forest floor to the canopy top. Crown foliage dominated the uptake of reactive N and S during the growing season, accounting for 80–90% of the total canopy-scale flux. Fluxes and canopy-ground partitioning estimated using the resistance-based Surface Tiled Aerosol and Gas Exchange (STAGE) model were generally comparable to EUL. The comparison highlights the need for improved parameterizations of litter exchange and NH 3 compensation points in resistance models for forest ecosystems. The findings here benefit the application of critical loads in forest ecosystems and guide further development of resistance-based exchange models.

54 ENVIRONMENTAL SCIENCES↗

Short-term apartment-level load forecasting using a modified neural network with selected auto-regressive features

Residential electricity load profiles and their diversity have become increasingly important to realize the benefits of Smart or Transactive Energy Networks (TENs). An important element of TENs will be practical, accurate, and implementable residential load forecasting techniques. While there have been many approaches to short-term load forecasting, few have included forecasting for individual households, partly because the high volatility and idiosyncrasies present in individual household load data can pose significant challenges. In this study, we develop a Convolutional Long Short-Term Memory-based neural network with Selected Autoregressive Features (termed a CLSAF model) to improve short-term household electricity load forecasting accuracy by employing three strategies: autoregressive features selection, exogenous features selection, and a “default” state to avoid overfitting at times of high load volatility. We include aggregations of apartments to floor and building level, because utilities may favor transactive approaches that rely on aggregator models, e.g., a cluster of consumers as opposed to an individual. We demonstrate that the CLSAF model, by virtue of its enhanced feature representation and modest computational resources, can accomplish load forecasting in a multi-family residential building across three spatial granularities (individual apartment/household, floor, and building levels), with an accuracy improvement of up to 25% compared to a persistence model. We propose a data screening technique to characterize time-series electricity-load data. This technique is suitable for integration into a TEN ecosystem and allows one to estimate confidence levels of the load forecasts to optimize computational resources and the risks associated with uncertain forecasts.

24 POWER TRANSMISSION AND DISTRIBUTION↗